HomeMy WebLinkAbout1985-03-20 On Site Sewage Treatment Inspection ReportON -SITE SEWAGE TREATMENT INSPECTION REPORT On the North Shore of Lake Alin netonka POST OFFICE BOX 66 CITY 1335 S. Brown Rd. Crystal Bay, MN 55323 O_ ONO 473-7357 111k —A A in - OWNER �g `fy EL- ADDRESS 6�7 C `�L-�NL-'�PL,C-F�r- PHONE PERMIT NO'S. 2-7 7 DATES City Ordinance No. 210 requires that each on -site sewage treatment system in Orono be inspected on a regular basis. The on -site sewage treatment system at the above address has been inspected and appears I , fall into the category checked below: Meets or exceeds current city standards in all respects relating to design, construction, and location. Appears to be operating properly. Does not meet current city standards in some respects relating to design,, construction, or location. Appears ,92 to be operating properly. Does not meet current city standards in many respects relatirg to design, construction, or location. Appears to be operating adequately. Does not meet current city standards of design, construction or location, is being overused, or is failing to 04 properly treat and dispose of the current input and is therefore endangerirg a water supply, is a source of pollution to surface or groundwaters, is creating a safety hazard, or is otherwise creating a public nuisance. Please contact the inspector to discuss requirements for repairs to your system. Soil testing may be re- quired. In all cases a design and site plan must be submitted for review. Your contractor must obtain a permit before work is started. WORK REQUIRED: Septic tanks must be pumped within 48 hours. Drainfield must be repaired or replaced within 90 days. Inspection riser (4" diam. pipe) must be installed in each tank. (� ❑ Tank inspection indicates umpout is needed as soon as possible. tanks be pumped o every three years. SITE CHARACTERISTICS: Limiting Site Factors ❑ Slope ❑Soil (]High water table ❑ Lot size Lake, wetland, or stream Drainage Potential for System Failure (deoends on soil types, water table, and system condition) ❑ Low Medium ❑ High ❑ System is causing visible surface discharge. City ordinance requires that Site Capabilities for Future Expansion ❑ Adequate Fair ❑ Poor ❑ Inadequate COMMENTS: 2 — 51x60' drainfield beds located, also note tanks are cone. blk. W/o solid bottoms; noted no evidence current or past discharge to surface, but liquid level in tanks is above tank cover, system is overfull which may be due to saturated ground at the present. Last documented pumpout was 1979 - suggest tha anks b_e_puMped out this year, perhaps tank level will return to normal as ground RKDc4(f?4M4 XWK dries out. Septic System Inspector This report must be kept on the premises with system location and pumping records. WHITE COPY / Inspector's File GOLD COPY / Homeowner