Loading...
HomeMy WebLinkAboutResolution 7579 Pre CIC Plat and Conditional Use Permit 430 Old Crystal Bay Rd LAND TYPE Torrens(T) DOC NUM 6136746 Certified, filed and/or recorded on May 21, 2025 10:50 AM Office of the Registrar of Titles Hennepin County, Minnesota Amber Bougie, Registrar of Titles Daniel Rogan, County Auditor and Treasurer Deputy 98 Pkg ID 2787454E Document Recording Fee $46.00 Document Total $46.00 Existing Certs 1589241 This cover sheet is now a permanent part of the recorded document. �00 CITY OF ORONO RESOLUTION OF THE CITY COUNCIL NO. 7579 iktsRoo' A RESOLUTION GRANTING PRELIMINARY APPROVAL FOR A CIC PLAT, CONDITIONAL USE PERMIT AND SITE PLAN APPROVAL FOR THE GARAGE CONDO DEVELOPMENT FILE NO. LA24-000068 WHEREAS, Orono Garage Condos LLC, (hereinafter the "Developer") on behalf of the owners Old Crystal Bay LLC, (hereinafter the"Owners") of the following property: 430 Old Crystal Bay Rd, (PID 33-118-23-13-0016) legally described within Exhibit A (hereinafter collectively the "Property"); WHEREAS on January 9, 2025, the Developer made a complete application for Preliminary Plat, Conditional Use Permit and Site Plan approval to create a garage condo development; and WHEREAS, on February 18, 2025, after published and mailed notice in accordance with Minnesota Statutes and the City Code, the Planning Commission held public hearings, at which time all persons desiring to be heard concerning this application were allowed to speak thereon; and WHEREAS, on February 18, 2024, the Planning Commission tabled the application provided guidance to the developer and regarding access, parking and landscaping changes; and WHEREAS, on March 17, 2025, the Planning Commission reviewed the revised application. Although the Developer provided the requested information, the site plan did not provide off-street parking on the site. The Commission was unsatisfied with the revised plans which did not identify off-street parking, with a vote of 4-1, recommended denial of the application as revised; and WHEREAS, on March 27, 2025, the Developer submitted revised plans addressing proof of parking identified with the site. WHEREAS, on April 14, 2025, the City Council reviewed the revised application, the recommendations of the Planning Commission and City staff, and made the following findings: FINDINGS OF FACT: Al. This application was reviewed as Zoning File#LA24-000068. The analysis contained within staff memos and the exhibits attached to the aforesaid memos, all minutes from the above- 1 icL0. - CITY OF ORONO RESOLUTION OF THE CITY COUNCIL 71, ��� NO. 7579 ��kssxo�� mentioned meetings, and all other materials distributed at these meetings are hereby incorporated by reference. A2. The Property is guided in the 2020-2040 Community Management Plan for industrial use. A3. The Property is located in the I- industrial Zoning District, which allows a garage condo business as a conditional use. A4. The Property contains 4.88 gross acres in area. A5. The proposal would create 85 condo units within 5 buildings. A6. The Property is located within the MUSA and will be served by city sewer and water. A7. The Property is within the Stormwater Quality Overlay District which restricts overall hardcover. The property is located in Tier 5 with a maximum allowed hardcover of 85%. The proposal results in 126,869 sq.ft of hardcover or 75% of the site. A8. The Developer has prepared grading plans to manage stormwater on-site. A9. A Site Plan Analysis was completed and the development of the vacant lot will meet all zoning standards according to the revised plans. A10. The existing public roadway, Orono Industrial Blvd, provides access to the Property. Orono Industrial Blvd will be constructed to complete the Crystal Bay Business Center development improvements. The existing right of way is unimproved and is scheduled to be built to meet city standards. A11. The proposal requires a preliminary and final plat due to the condo plat proposed. The land is not being subdivided. The proposed development is not a subdivision therefore, park dedication fees or Conservation Design Plans are not required. CONDITIONAL USE PERMIT ANALYSIS: The City Council may approve a conditional use permit for garage condo use as long as the following criteria are met: B1.No exterior parking or storage is permitted for a period longer than twenty-four(24) hours. A parking plan must be provided to demonstrate accessibility to the site. The applicant has submitted a proof of parking plan noting parking for each unit and 7 additional possible additional guest parking stalls. The applicant notes that the site does not support outdoor storage or overnight parking. Additionally, the applicant notes in their covenants that no 2 gOt�rO CITY OF ORONO RESOLUTION OF THE CITY COUNCIL NO. 7579 t'kESHO outdoor storage will be permitted. This standard it met. B2.The premises shall not be used or customized for residential living purposes or community gatherings or events. The development is within the industrial district which does not support living and dwelling units. The developer's covenant includes prohibition of living/dwelling within units on site as well a prohibition on holding "events". The covenant also defines events. The definition of"events"is included as a listed condition to clarify the use on the site. This condition is met. B3.The premises shall not be used for the operation of a business for retail purposes, including but not limited to automobile repair. This does not prohibit minor maintenance, care, or upkeep of motor vehicles, boats, trailers, or recreational vehicles stored in individual units. Storage and warehousing may be permitted. This condition is met for the proposed development. If any new or more intense uses are contemplated in the future, a review by City staff and approval by the City Council is required. This condition is met. B4.The management, use, and customization of the garage condos, including common areas, and individual units, shall be governed by an association, which association rules shall place adequate controls to ensure compliance with applicable city code. A draft declaration of covenants for management of the development has been provided by the Developer. This condition will be met. This condition is met. B5.The premises shall maintain adequate access to individual units and any common areas or office space for emergency response and snow removal/storage. The developers propose easements for access, drainage, and utilities throughout the common spaces including the drive aisles. A knox box will be placed at the entrance gate for emergency personnel and vehicle access. This condition is met. This condition is met. B6.The premises shall contain sufficient lighting and/or security measures to deter or mitigate criminal activity and ensure adequate access for emergency response.A lighting plan has been provided. The property is also proposed to be fenced and gated. This condition is met. B7.Any individual unit that is connected to the city sewer and water system shall have individual meters. The applicant is proposing individual water and sewer connections to serve building; and each unit will have their own meter. This condition is met. Based on the application and the evidence submitted, the Council finds that the proposed use at the proposed location is or will be: 3 0A4 CITY OF ORONO RESOLUTION OF THE CITY COUNCIL NO. 7579 -ikESHO B8.Consistent with the community management plan; The proposed use is consistent with the community management plan. The garage condo use is consistent with the intended Industrial use of the site. B9.Compliant with the zoning code, including any conditions imposed on specific uses as required by article V, division 3 of the City Code; The proposed use meets the requirements of the Code within the Industrial District as a Conditional Use. B10. Adequately served by police, fire, roads, and stormwater management; The site is adequately served by police, fire, roads, and storm water management. The proposed site has been reviewed by the police, fire and engineering departments and the site meets the development standards to support this application. B11. Provided with an adequate water supply and sewage disposal system; The site is provided with adequate water supply and sewage disposal system for the proposed use. The utilities within the development be privately installed and maintained. The City will have access for utility shut off and emergency services. The developer will be responsible for installation and maintenance of the utility infrastructure. Each unit will be individually metered to follow the CUP standards. B12. Not expected to generate excessive demand for public services at public cost; A storm pond is proposed. The proposed use is not expected to generate an excessive demand for public services at public cost based on other similar developments'historic operating records. B13. Compatible with the surrounding area as the area is used both presently and as it is planned to be used in the future; The proposed use is compatible with the surrounding area and with the other Industrial uses. There are residentially-zoned properties across Old Crystal Bay Road North. This low-intensity Industrial use is preferable to the adjacent residential properties as compared other Industrial uses such as manufacturing or uses which may create more noise, pollution or other externalities. B14. Consistent with the character of the surrounding area, unless a change of character is called for in the community management plan; The design of the buildings is consistent with the architectural design standards outlined for the industrial district and the industrial uses. B15. Compatible with the character of buildings and site improvements in the surrounding area, unless a change of character is called for in the community management plan; The design of the buildings and site are consistent with the surrounding area. B16. Not expected to substantially impair the use and enjoyment of the property in the area or have a materially adverse impact on the property values in the area when compared to the impairment or impact of generally permitted uses; This is a conditional use within the Industrial district. It will not impair the use and enjoyment of the properties in the area. The development is proposed to meet the conditions of the district. 4 SON, CITY OF ORONO RESOLUTION OF THE CITY COUNCIL NO. 7579 t9kasxo�� B17. Provided with screening and buffering adequate to mitigate undesirable views and activities likely to disturb surrounding uses; The proposed landscape plan includes a variety of plantings on the edge of the property creating screening for the site. The site is surrounded on two sides by industrial parcels, a state highway to the south, and a residential development to the west separated by a 66-foot-wide right-of-way(Old Crystal Bay Road N). The proposed vegetative screening and distance from the adjacent residential developments should provide adequate mitigation from any negative impacts of the site. B18. Not create a nuisance which generates smoke, noise, glare, vibration, odors, fumes, dust, electrical interference, general unsightliness, or other means; Access to the site is off of an interior road within the industrial district. The site is designed with fencing and landscaping around the perimeter to buffer any adverse impacts. The applicant states the activity resulting from the Garage Condos will not cause a nuisance, smoke, noise, glare, vibration, odors, fumes, dust, electrical interference, or general unsightliness. B19. Not cause excessive non-residential traffic on residential streets, parking needs that cause a demonstrable inconvenience to adjoining properties, traffic congestion, or unsafe access; The adjoining properties should not experience parking issues or traffic congestion. The proposed use is expected to have significantly less traffic than the generally allowed uses in the Industrial zoning district. The site will support the parking needs generated by the use. B20. Designed to take into account the natural, scenic, and historic features of the area and to minimize environmental impact; The site is designed to enhance the natural environment with the storm water management and planting plans. The site was originally graded when the Crystal Bay Business Center developed was platted in 2007 and has been vacant with no native plantings or natural areas. B21. All exterior lighting shall be so directed so as not to cast glare toward or onto the public right-of-way or neighboring residential uses or districts; and The lighting for the site is designed to aim downwards and will not cast glare toward public right-of-way or neighboring residential uses or districts. B22. Not detrimental to the public health, public safety, or general welfare. The proposed use is not detrimental to the public health, public safety, or general welfare and is expected to less impact as a garage condo development than the generally allowed uses within the Industrial zoning district. B23. Economic return. The use will provide an economic return to the community and be commensurate with other industrial uses for which the property could feasibly be used. In considering the economic return to the city, the planning commission and city council may give weight to the sociological impact of proposed use, both positive and negative. The use is consistent with the industrial district and other surrounding uses. The site is screened 5 �O�rO CITY OF ORONO RESOLUTION OF THE CITY COUNCIL NO. 7579 t,4SHO and buffered from abutting residential districts. The use of the property will be interior to the buildings with little exterior activity thus limiting negative impacts to the surrounding area. CONCLUSIONS, ORDER AND CONDITIONS: NOW, THEREFORE, BE IT RESOLVED, based upon one or more of the above findings, the Orono City Council hereby grants Preliminary CIC Plat, Conditional Use Permit and Site Plan Approvals allowing the Developer to proceed with a final plat of the Property to allow a garage condo development with a stormwater pond. The preliminary plat (attached as Exhibit B) together with the stormwater grading, site plan, and landscape plan will establish the elevations, drainage swales, and stormwater basins, common element spaces, landscaping and building footprints for the site. Preliminary Plat approval is subject to the following conditions: C1. Approval is subject to Minnehaha Creek Watershed District(hereinafter the "MCWD") approval and permits as required. Final Plat approval shall not be granted until the Developer has provided evidence that all required MCWD permits have been obtained. C2. Approval is subject to drainage, utility and access easement dedications. C3. The Developer shall address all outstanding engineering comments and/or conditions provided by the City Engineer with the Final Plat development plan submittal. C4. The erosion control plan shall adhere to "Best Management Practices for Protecting Water Quality in Urban Areas" and to the approved SWPPP. All erosion controls as required by the City and the MCWD shall be in place before commencing grading and excavation on the site. All such erosion control measures shall be maintained in working order until the site is vegetated and stabilized. C5. Upon evidence of resettlement history, the Developer shall cease all activity and contact the City and the Minnesota State Historic Preservation Office (SHPO) before proceeding. C6. Violation of or non-compliance with any of the terms and conditions of this resolution may result in the termination of any authority granted herein. C7. Easements Required. 1. Drainage and Utility Easements shall be dedicated to the public on the Final Plat 10' along all exterior property lines, except such easements shall be increased to accommodate drainage where required, subject to City staff approval. 2. A Drainage and Utility easement shall be dedicated to the public on the plat over stormwater pond areas, drainageways, and stormwater facilities. 6 i OHO CITY OF ORONO RESOLUTION OF THE CITY COUNCIL c> NO. 7579 4kESHO4t 3. A Utility and Access Easement shall be granted to the City over the common element space which align with the drive aisles on the Property. C8. Development Fees: a. Stormwater and Drainage Trunk Fee: The property will be subject to the 2025 Stormwater and Drainage Trunk Fee of$9,690.00 per acre. The 4.89 acres property is proposed to be developed, therefore $9,690.00 x 4.89 = $47,384.10. b. Water and Sewer Connection Permits: Connection permits will be required for each individual unit (85 units proposed) and will follow the applicable fee schedule. The individual permits and fees will be due when the connection is being installed to each unit with the building permit. c. Met Council Sewer Availability Charge: Due to the size of the buildings and the number/type of proposed connections it is estimated that the development will require 14 SAC units in total according to the Met Council determination letter. Below is the break down for SAC units for each building. The SAC fee will be collected with each building permit. i) Building 1:1 SAC Unit ii) Building 2: 3 SAC Units iii) Building 3: 4 SAC Units iv) Building 4: 4 SAC Units v) Building 5: 2 SAC Units The current fee is $2,485.00 per SAC unit which would result in a total of(14 x $2,485) $34,790.00 required to connect in 2025. d. Water and Sewer Area Connections: The city determined that the units identified by the Met Council should be used to apply the water and sewer area connection charges. The City of Orono does not have a unit breakdown for industrial uses and the regional authority made a determination of use as it compares to single family homes. Following their logic, it is appropriate to apply the same SAC unit determination when applying the water and sewer area connection fees. These fees will be collected with each building permit. The following fees are proposed to be required using the 2025 fee schedule for $4,370.00 water unit and $6,000.00 per sewer unit. (Total $10,370.00 per unit) i) Building 1:1 SAC Unit = $10,370.00 ii) Building 2: 3 SAC Units = $ 31,110.00 iii) Building 3: 4 SAC Units = $41,480.00 iv) Building 4: 4 SAC Units = $41,480.00 v) Building 5: 2 SAC Units = $20,740.00 In total all 5 buildings will result in 14 SAC units and would require (14 x $10,370.00) $145,180.00 in fees for water and sewer area connection fees. 7 O CITY OF ORONO RESOLUTION OF THE CITY COUNCIL C. NO. 7579 {'kESHO%L‘C' C9. Plans and Specifications. The following plans and specifications shall be submitted for review and approval by the City and other appropriate jurisdictions before Final Plat approval, to ensure that the proposed plat will accomplish the intended purposes: 1. Final grading, drainage, and erosion control plan showing existing and proposed contours, anticipated building locations, elevations, stormwater facilities and calculations, utilities and erosion control measures to be used during construction. 2. Final Landscape Plan which shall include planting plans with tree calculations. 3. Final Stormwater Management Plan. 4. Final stormwater pollution prevention plan (SWPPP). 5. Sufficient detail to meet the recommendations of the City Engineer. C10. Council approval is based on the entire record and the above Findings. Any amendments to the plans that are not in conformity with City codes may require further Planning Commission and City Council review. This approval does not limit the City from revising or amending these conditions as the review process continues. C11. Authorities granted by this resolution run with the Property not with the Owners, but are permissive only and must be exercised by filing a Final Plat application within one year of the date of Council approval, or the preliminary plat approvals will expire on that date. C12. Conditional Use Permit Conditions: a. Approval of the CUP will be conditioned upon preliminary and final plat approval. b. All permitting from MCWD and other agencies must be obtained prior to issuance of building permits. c. Any changes to or intensification of the use may trigger additional council review and approval. d. All City Staff comments must be addressed prior to placement on the City Council's agenda for final plat review. e. The hours of operation for the site are set as 6am - 10pm 7-days a week. f. The premises shall not be used or customized for residential living purposes or community gatherings or events. Events in this context means: outdoor activities on the property, such as promotional events, gatherings, demonstrations, displays or other activities which affect any easement or use right, obstruct driveways, access roads, or Common Elements. FINAL SUBMITTALS: The Developer shall complete all requirements for Final Plat Approval and all final submittals must be submitted to the Planning Department at least four(4) weeks before the regularly 8 gO�rO CITY OF ORONO RESOLUTION OF THE CITY COUNCIL c, NO. 7579 'QsHoo' scheduled Council meeting on the second and fourth Mondays of the month. These submittals are as follows: Cl.Record Plat Drawings. Record plat drawings in the form of two draft (2) copies (one copy for the City's records and one for filing with Hennepin County) and one (1) copy reduced to 1" = 200'. A digital copy is also required. Drawing to include: a. Lot lines platted per preliminary plat survey/drawing by Civil Methods Inc., dated 12-28-2024 attached hereto as Exhibit B, except as modified herein. b. Dedication of"Drainage and Utility Easements" 10' along exterior property lines, and over the stormwater pond, ditches, and facilities. c. Dedication of"Ingress, Egress, Drainage and Utility Easement" over the Common Element space. d. Name of the plat. Record mylar drawing will be due at the time of recording for the CIC. Once the building are substantially completed the mylars will need to be signed and recorded before building final and occupancy of the building approved. C2.Financial Guarantee. The Development Agreement shall include a financial guarantee by the Developer to ensure the completion of site improvements. The Developer shall provide Itemized construction estimates for all development improvements. The City Engineer shall review the estimate of improvement costs, including but not limited to storm sewers, landscaping, grading, erosion control, utilities, roads, and stormwater management facility construction, and the Developer shall provide a financial guarantee in an amount equal to 125% of the improvement costs to the City. C3.Legal documents required: a. Title commitment addressed to the City less than 90 days old. All owners, mortgage holders, or others with property interest indicated therein shall sign the plat and all other documents affected by such interest. b. The Developer must provide certified copies of all recorded easements currently affecting the Property. c. The City Engineer shall establish the amount to be provided in the Letter of Credit. 9 �O�rO CITY OF ORONO RESOLUTION OF THE CITY COUNCIL ti� Lti4 NO. 7579 t'kESH04� d. Signed Developers Agreement and Letter of Credit (in the city's format) for construction of improvements. C4.Plat approval fees to be paid: Total due: $47,384.10 a. Stormwater and Drainage Trunk Fee: $47,384.10. C5.Staging: Final platting will go to the City Council with a draft of the final plat mylars. The draft final plat must be approved by the City Council. Before building permits are issued, approval of the draft final plat, recording of the development agreement, and easement much be completed. Final mylars can be record once the building is substantially completed. Building final and Certificate of Occupancy will be held until the Final Plat for the applicable buildings are recorded with Hennepin County. The developers are proposing a constructing Buildings 1 and 2 in 2025. Separate Final Plat approval will be required when Building 3,4, and 5 are proposed to be constructed. C6.Violation of or non-compliance with any of the terms and conditions of this resolution may result in the termination of any authority granted herein. C7.According to City Code Section 82-116, this Preliminary Plat approval shall be effective for one year, until April 28, 2026. Failure to file a complete final plat application within this period shall be construed as a formal withdrawal of the proposed plat and the terms and conditions of this resolution shall be null and void. The applicant should anticipate the timing of the construction of their project and request any necessary extensions that may be needed. ADOPTED by the Orono City Council on this 28th day of April, 2025. ATTEST: CITY OF ORONO: /t Ch 'sti e Lusi _City Clerk Alisa Benson, Acting Mayor 10 Exhibit A 430 Old Crystal Bay Road LEGAL DESCRIPTION That part of Lot 1, Block 1, Crystal Bay Business Center, embraced within Lot 4, Block 1, Van Dale Addition, Hennepin County, Minnesota Per Torrens Certificate No. 15 73287 Lot 1, Block 1, Crystal Bay Business Center, EXCEPT that part embraced within Lot 4, Block 1, Van Dale Addition, Hennepin County, Minnesota. Abstract Property Resolution 7579 I HEREBY CERTIFY THAT THIS PLAN WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION, AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA. SIGNATURE: __________________________________________TYPED OR PRINTED NAME: MATTHEW R. HAGSTROM DATE: 03/03/2025 LICENSE NUMBER: 50731 Designed By:Date: Job No.: FOR AND ON BEHALF OF HAGSTROM ENGINEERING PLLC Checked By:811 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL GOPHER STATE ONE CALL BENCHMARK:ByDateDescription of RevisionsNo.Sheet of D C B A 54321 219 6TH AVENUE EAST ALEXANDRIA, MN 56308 P.320.759.0764 WWW.HAGSTROMENG.COM HAGSTROM ENGINEERING CIVIL ENGINEERS | LAND CONSULTANTS CAUTION: IF THIS SHEET IS NOT 24"X36" IT IS A REDUCED PRINT C5.0C1.0 C1.0ORONO GARAGE CONDOSSITE PLANCOVER SHEET03/03/2025 24015 LEHMRHSITE PLAN LOT 1, BLOCK 1, CRYSTAL BAY BUSINESS CENTER HENNEPIN COUNTY, STATE OF MINNESOTA SHEET INDEX C1.0 COVER SHEET C2.0 EXISTING SITE AND DEMO PLAN C3.0 PROPOSED SITE PLAN C3.1 PROPOSED UTILITY PLAN C3.2 SANITARY SEWER PLAN AND PROFILE C3.3 STORM SEWER PLAN AND PROFILE C4.0 PROPOSED GRADING & EROSION C4.1-C4.4 DETAILED GRADING PLAN C4.5 DETAILED POND PLAN C5.0 - C5.2 CONSTRUCTION DETAILS CONTACT LIST OWNER ORONO GARAGE CONDOS 5840 CLUB VALLEY ROAD SHOREWOOD, MN 55331 (952) 200-6384 CONTACT: DAVE RAMSEY, ROB PAGE CIVIL ENGINEER HAGSTROM ENGINEERING 219 6TH AVENUE E ALEXANDRIA, MN 56308 320-759-0764 CONTACT: MATT HAGSTROM SITE OLD CRYSTAL BAY RD NWAYZATA BLVD WILLOW DRIVE NSTATE HWY 12 EXISTING FIRE HYDRANT LOCATED AT THE MID POINT OF NORTH PROPERTY LINE, TOP NUT OF HYDRANT =1026.02 OLD CRYSTAL BAY ROADMNDOT RIGHT OF WAY PLAT NO 27-129 TEMPUS ORONO LLC PID: 3311823130020 METRO STORAGE ORONO LLC PID: 3311823130019 WJM PROPERTIES LLC PID: 3311823130015 ORONO PRESERVE RESIDENTIAL DEVELOPMENT ORONO INDUSTRIAL BOULEVARD ST ST ST PROPOSED IMPROVEMENTS SHOWN AS EXISTING EX. 10.0' DRAINAGE & UTILITY EASEMENT EX. 10.0' DRAINAGE & UTILITY EASEMENT EX. 10.0' DRAINAGE & UTILITY EASEMENT EX. 22.0' DRAINAGE & UTILITY EASEMENT S89°43'30"E 1,898.43'N00°16'00"E 1,898.43'N 5 5 ° 2 3 ' 0 7 " W 1 , 8 9 8 . 4 3 ' N89°11'02"W 1,898.43'S00°14'12"W 1,898.43'EX. 8" WATER MAIN, T.R. (TYP) EX. 8" WATER STUB, T.R. EX. 8" WATER STUB, T.R. EX. SAN. MH WITH 8" MAIN, T.R. EX. 8" SAN., T.R. (TYP) EX. BOUNDARY (TYP) EX. 60.0' ROW EX. 66.0' ROW EX. STORM SEWER, T.R. (TYP) EX. CULVERT, 41.4 LF T.B.R. EX. BOUNDARY (TYP) EX. FENCE, T.B.R. EX. STORM SEWER STRUCTURES, T.R. (TYP) EX. WALL, T.R. (TYP) EX. FENCE, T.B.R. EX. WALK, T.R. (TYP) EX. CURB & GUTTER, T.R. (TYP) EX. FIRE HYD., T.R. (TYP) EX. FENCE, T.R. (TYP) EX. CURB & GUTTER, 48 LF T.B.R. I HEREBY CERTIFY THAT THIS PLAN WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION, AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA. SIGNATURE: __________________________________________TYPED OR PRINTED NAME: MATTHEW R. HAGSTROM DATE: 03/03/2025 LICENSE NUMBER: 50731 Designed By:Date: Job No.: FOR AND ON BEHALF OF HAGSTROM ENGINEERING PLLC Checked By:811 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL GOPHER STATE ONE CALL BENCHMARK:ByDateDescription of RevisionsNo.Sheet of D C B A 54321 219 6TH AVENUE EAST ALEXANDRIA, MN 56308 P.320.759.0764 WWW.HAGSTROMENG.COM HAGSTROM ENGINEERING CIVIL ENGINEERS | LAND CONSULTANTS CAUTION: IF THIS SHEET IS NOT 24"X36" IT IS A REDUCED PRINT C5.0C2.0 C2.0ORONO GARAGE CONDOSSITE PLANEXISTING SITE AND DEMO PLAN03/03/2025 24015 LEHMRH0 SCALE: 1" = ORIGINAL GRAPHIC SCALE 15 30 60 30' EXISTING PROPERTY BOUNDARY EXISTING RIGHT OF WAY EXISTING LOT EXISTING EASEMENT EXISTING STORM SEWER W/ MANHOLE EXISTING SANITARY SEWER W/ MANHOLE EXISTING WATER MAIN W/ VALVE & HYDRANT EXISTING ELECTRIC EXISTING ELECTRICAL PEDESTAL EXISTING GAS EXISTING TELEPHONE EXISTING CONCRETE EXISTING ASPHALT EXISTING FENCE EXISTING CURB & GUTTER DEMO CULVERT DEMO FENCE DEMO CURB & GUTTER EXISTING TYPICAL TO REMAIN TO BE REMOVED EX. (TYP) T.R. T.B.R. S E NOTES: 1.CONTRACTOR SHALL FIELD VERIFY SIZE AND LOCATION OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION AND NOTIFY THE ENGINEER WITH ANY DISCREPANCIES. 2.CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL NECESSARY CONSTRUCTION STAKING. 3.INSTALL PERIMETER BMP'S PRIOR TO ANY CONSTRUCTION, SEE SHEET C4.0. 4.ALL TREES AND TREE ROOT ZONES OUTSIDE OF THE LIMITS OF CONSTRUCTION SHALL NOT BE DISTURBED. 5.SEE SHEET C5.0 - C5.2 FOR CONSTRUCTION DETAILS. ST LEGEND EXISTING FIRE HYDRANT LOCATED AT THE MID POINT OF NORTH PROPERTY LINE, TOP NUT OF HYDRANT =1026.02 OLD CRYSTAL BAY ROADMNDOT RIGHT OF WAY PLAT NO 27-129 TEMPUS ORONO LLC PID: 3311823130020 METRO STORAGE ORONO LLC PID: 3311823130019 WJM PROPERTIES LLC PID: 3311823130015 ORONO PRESERVE RESIDENTIAL DEVELOPMENT ORONO INDUSTRIAL BOULEVARD PROPOSED IMPROVEMENTS SHOWN AS EXISTING EX. 10.0' EASEMENT EX. 10.0' EASEMENT EX. 10.0' EASEMENT EX. 22.0' EASEMENT S89°43'30"E 1,898.43'N00°16'00"E 1,898.43'N 5 5 ° 2 3 ' 0 7 " W 1 , 8 9 8 . 4 3 ' N89°11'02"W 1,898.43'S00°14'12"W 1,898.43'20.0' SETBACK 35.0' SETBACK 35.0' SETBACK 10.0' SETBACK EX. BOUNDARY EX. BOUNDARY EX. 60.0' ROW EX. 66.0' ROW 40.0' 50.0' 50.0'50.0' 20.0'20.0' 4.0' CONCRETE APRON (TYP) 40.0' 240.0' 20.0'20.0' 46.0' 275.0'275.0' 92.0' 92.0' 275.0' 275.0'260.0' 3.0' CONCRETE PAN (TYP) 32.0' R25.0' R20.0' 14.5' ASPHALT 20.0' 20.0' 31.0' 31.0'31.0' 24.0'24.0' 31.0' 24.0' 31.0' 24.0' 20.0' 20.0' PROPOSED IFC TURNAROUND AT ENTRANCE 40.0' 46.0' 11.5' ASPHALT 8.5' ASPHALT 8.5' ASPHALT BUILDING 1 BUILDING 2 BUILDING 3 BUILDING 4 BUILDING 5 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 PROPOSED FENCE PER CITY OF ORONO STANDARDS (TYP) SLIDING GATE W/ ELECTRONIC ACCESS, DESIGNED BY OTHERS PROPOSED FENCE PER CITY OF ORONO STANDARDS (TYP) PROPOSED FENCE PER CITY OF ORONO STANDARDS (TYP)PROPOSED RETAINING WALL 27.5' ASPHALT 11.5' ASPHALT 27.5' ASPHALT 11.5' ASPHALT 27.5' ASPHALT MAIN DRIVE SECTION N.T.S ℄ 10.0'10.0' ASPHALT SECTION PER SHEET C5.0 CONCRETE V-PAN PER SHEET C5.0 2.0% - 4.0%2.0% - 4.0% TIE-IN TO ADJACENT, VARYING SLOPE (TYP) I HEREBY CERTIFY THAT THIS PLAN WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION, AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA. SIGNATURE: __________________________________________TYPED OR PRINTED NAME: MATTHEW R. HAGSTROM DATE: 03/03/2025 LICENSE NUMBER: 50731 Designed By:Date: Job No.: FOR AND ON BEHALF OF HAGSTROM ENGINEERING PLLC Checked By:811 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL GOPHER STATE ONE CALL BENCHMARK:ByDateDescription of RevisionsNo.Sheet of D C B A 54321 219 6TH AVENUE EAST ALEXANDRIA, MN 56308 P.320.759.0764 WWW.HAGSTROMENG.COM HAGSTROM ENGINEERING CIVIL ENGINEERS | LAND CONSULTANTS CAUTION: IF THIS SHEET IS NOT 24"X36" IT IS A REDUCED PRINT C5.0C3.0 C3.0ORONO GARAGE CONDOSSITE PLANPROPOSED SITE PLAN03/03/2025 24015 LEHMRH0 SCALE: 1" = ORIGINAL GRAPHIC SCALE 15 30 60 30' NOTES: 1.CONTRACTOR SHALL FIELD VERIFY SIZE AND LOCATION OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION AND NOTIFY THE ENGINEER WITH ANY DISCREPANCIES. 2.CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL NECESSARY CONSTRUCTION STAKING. 3.INSTALL PERIMETER BMP'S PRIOR TO ANY CONSTRUCTION, SEE SHEET C4.0. 4.ALL TREES AND TREE ROOT ZONES OUTSIDE OF THE LIMITS OF CONSTRUCTION SHALL NOT BE DISTURBED. 5.SEE SHEETS L1.0 - L1.1 FOR DETAILED LANDSCAPE PLANS. 6.SEE SHEETS C5.0 - C5.2 FOR CONSTRUCTION DETAILS. LEGEND EXISTING PROPERTY BOUNDARY EXISTING RIGHT OF WAY EXISTING EASEMENT PROPOSED CONCRETE EXISTING ASPHALT PROPOSED ASPHALT PROPOSED FENCE EXISTING FENCE EXISTING CURB & GUTTER EXISTING TYPICAL EX. (TYP) EXISTING FIRE HYDRANT LOCATED AT THE MID POINT OF NORTH PROPERTY LINE, TOP NUT OF HYDRANT =1026.02 OLD CRYSTAL BAY ROADMNDOT RIGHT OF WAY PLAT NO 27-129SFORONO INDUSTRIAL BOULEVARD ST ST STWFWFWFWFWFWSSSSSSSFWFW EX. BOUNDARY (TYP) EX. STORM SEWER (TYP) 8" GATE VALVE N: 171,394.94 E: 445,856.86 8" TEE W/ TB N: 171,395.01 E: 445,842.14 8" TEE W/ TB N: 171,395.69 E: 445,700.14 8" GATE VALVE N: 171,395.87 E: 445,663.988" 90° BEND W/ TB & 6" REDUCER N: 171,396.65 E: 445,499.95 CONNECT TO EX. WATER N: 171,400.01 E: 445,842.17 CONNECT TO EX. WATER N: 171,400.69 E: 445,700.16 5.0 LF~8" C900 WATER MAIN 14.7 LF~8" WATER MAIN 137.2 LF~8" WATER MAIN 125.4 LF~8" WATER MAIN 5.0 LF~8" C900 WATER MAIN BUILDING 1 BUILDING 2 BUILDING 3 BUILDING 4 BUILDING 5 8" X 6" TEE W/ TB N: 171,396.05 E: 445,625.39 8" X 6" TEE W/ TB N: 171,396.01 E: 445,633.39 8" X 6" TEE W/ TB N: 171,395.42 E: 445,757.14 8" X 6" TEE W/ TB N: 171,395.38 E: 445,765.14 8" X 6" TEE W/ TB N: 171,394.74 E: 445,899.14 8" X 6" TEE W/ TB N: 171,394.70 E: 445,907.14 8" 90° BEND W/ TB & 6" REDUCER N: 171,394.04 E: 446,044.34 8.0 LF~8" WATER MAIN 36.2 LF~8" WATER MAIN 8.0 LF~8" WATER MAIN 30.6 LF~8" WATER MAIN 57.0 LF~8" WATER MAIN 8.0 LF~8" WATER MAIN 77.0 LF~8" WATER MAIN 42.3 LF~8" WATER MAIN METER PIT N: 171,390.24 E: 445,503.95 METER PIT N: 171,389.58 E: 445,620.36 METER PIT N: 171,389.49 E: 445,638.36 METER PIT N: 171,388.94 E: 445,752.11 METER PIT N: 171,388.85 E: 445,770.11 METER PIT N: 171,388.26 E: 445,894.11 METER PIT N: 171,388.18 E: 445,912.11 METER PIT N: 171,387.56 E: 446,040.31 TYPICAL FIRE SERVICE TYPICAL WATER SERVICE SANITARY MAIN (TYP) SANITARY SERVICE (TYP) WET TAP (TYP)WET TAP (TYP) I HEREBY CERTIFY THAT THIS PLAN WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION, AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA. SIGNATURE: __________________________________________TYPED OR PRINTED NAME: MATTHEW R. HAGSTROM DATE: 03/03/2025 LICENSE NUMBER: 50731 Designed By:Date: Job No.: FOR AND ON BEHALF OF HAGSTROM ENGINEERING PLLC Checked By:811 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL GOPHER STATE ONE CALL BENCHMARK:ByDateDescription of RevisionsNo.Sheet of D C B A 54321 219 6TH AVENUE EAST ALEXANDRIA, MN 56308 P.320.759.0764 WWW.HAGSTROMENG.COM HAGSTROM ENGINEERING CIVIL ENGINEERS | LAND CONSULTANTS CAUTION: IF THIS SHEET IS NOT 24"X36" IT IS A REDUCED PRINT C5.0C3.1 C3.1ORONO GARAGE CONDOSSITE PLANPROPOSED UTILITY PLAN03/03/2025 24015 LEHMRH0 SCALE: 1" = ORIGINAL GRAPHIC SCALE 15 30 60 30' LEGEND EXISTING STORM SEWER, MANHOLE, F.E.S. AND INLET PROPOSED STORM SEWER, MANHOLE, F.E.S. AND INLET EXISTING ROW PROPOSED ROW EXISTING LOT LINE PROPOSED LOT LINE PROPERTY BOUNDARY PROPERTY SETBACK EXISTING EASEMENT PROPOSED EASEMENT PROPOSED SANITARY SEWER W/ MH EXISTING SANITARY SEWER W/ MH PROPOSED UNDERDRAIN AND CLEANOUT PROPOSED WATER LINE, VALVE AND FIRE HYDRANT EXISTING WATER LINE AND VALVE PROPOSED WATER SERVICE W/ METER PROPOSED SANITARY SERVICE EXISTING GAS LINE EXISTING OVERHEAD ELECTRIC EXISTING ELECTRIC EXISTING CABLE TV EXISTING FIBER OPTIC EXISTING TELEPHONE TYPICAL CAUTION! UTILITY CROSSING LOWERING MAY BE REQUIRED EXISTING LIGHT POLE PROPOSED LIGHT POLEWSS NOTES: 1.CONTRACTOR SHALL FIELD VERIFY SIZE AND LOCATION OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION AND NOTIFY THE ENGINEER WITH ANY DISCREPANCIES. 2.CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL NECESSARY CONSTRUCTION STAKING. 3.INSTALL PERIMETER BMP'S PRIOR TO ANY CONSTRUCTION, SEE SHEET C4.0. 4.ALL TREES AND TREE ROOT ZONES OUTSIDE OF THE LIMITS OF CONSTRUCTION SHALL NOT BE DISTURBED. 5.ALL UTILITIES WITHIN PROPERTY BOUNDARIES ARE PRIVATE. 6.ALL WATER SERVICES ARE 10 LF, XX" DIAMETER UNLESS OTHERWISE NOTED. 7.ALL FIRE SERVICES ARE 10 LF, 6" DIAMETER W/ GATE VALVE UNLESS OTHERWISE NOTED. 8.ALL WATER MAINS ARE 8" DIAMETER, MAINTAIN POSITIVE GRADE, 8' MIN. COVER. 9.ALL WATER MAINS AND SERVICES SHALL MEET AWWA C900 QUALITY STANDARD. 10.AN ACCESSIBLE BLUE 14 AWG MINIMUM TRACER WIRE SUITABLE FOR DIRECT BURY MUST BE USED 11.SEE SHEET C5.0 - C5.2 FOR CONSTRUCTION DETAILS. TYP EXISTING FIRE HYDRANT LOCATED AT THE MID POINT OF NORTH PROPERTY LINE, TOP NUT OF HYDRANT =1026.02 SFST ST STWFWFWFWFWFWSSSSSSSFWFW EX. BOUNDARY (TYP) 15+249+70 10+00 11+00 12+00 13+00 14+00 15+00PI: 12+55.59S SSMH-1 4' SSMH N: 171,406.55 E: 445,522.19 CONNECT TO EX. SSMH-1 4' SSMH N: 171,410.28 E: 445,777.76 SSMH-2 4' SSMH N: 171,404.18 E: 446,016.19 ORONO INDUSTRIAL BOULEVARD OLD CRYSTALBAY ROADMNDOT RIGHT OF WAY PLAT NO 27-129 8" SDR 35 8" SDR 35 EX. 60.0' ROW EX. 66.0' ROW PROP. 6" SANITARY SERVICE W/CO (TYP) BUILDING 1 BUILDING 2 BUILDING 3 BUILDING 4 BUILDING 5 8"X6" WYE (TYP) ALIGNMENT NAME: Sanitary 1 PROFILE HORIZONTAL SCALE: 50.00 VERTICAL SCALE: 5.00 GRAPH VERTICAL EXAGGERATION: 10.00 STATION RANGE: 9+00 - 16+00 PROFILE VIEW ELEVATION RANGE: 1005.00 - 1035.00 1005 1010 1015 1020 1025 1030 1035 1005 1010 1015 1020 1025 1030 1035 9+00 10+00 11+00 12+00 13+00 14+00 15+00 16+00 SSMH-1 4' SSMH RIM:1026.07± INV OUT:1014.18 (8" PVC) (E) CUT=11.9± EX. SSMH-1 4' SSMH RIM:1024.56± INV IN:1012.90 (8" PVC) (E) INV IN:1012.90 (8" PVC) (W) INV OUT:1012.70 (8" PVC) (N) CUT=11.9± SSMH-2 4' SSMH RIM:1022.00± INV OUT:1014.09 (8" PVC) (W) CUT=7.9± 255.6 LF~ 8" SDR 35 @ 0.50%238.5 LF~ 8" SDR 35 @ 0.50% PROPOSED GRADE @ SANITARY ℄ EXISTING GROUND @ SANITARY ℄ 2.8' 1.6' EX. 8" WATER APPROX. DEPTH EX. 8" WATER APPROX. DEPTH I HEREBY CERTIFY THAT THIS PLAN WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION, AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA. SIGNATURE: __________________________________________TYPED OR PRINTED NAME: MATTHEW R. HAGSTROM DATE: 03/03/2025 LICENSE NUMBER: 50731 Designed By:Date: Job No.: FOR AND ON BEHALF OF HAGSTROM ENGINEERING PLLC Checked By:811 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL GOPHER STATE ONE CALL BENCHMARK:ByDateDescription of RevisionsNo.Sheet of D C B A 54321 219 6TH AVENUE EAST ALEXANDRIA, MN 56308 P.320.759.0764 WWW.HAGSTROMENG.COM HAGSTROM ENGINEERING CIVIL ENGINEERS | LAND CONSULTANTS CAUTION: IF THIS SHEET IS NOT 24"X36" IT IS A REDUCED PRINT C5.2C3.2 C3.2ORONO GARAGE CONDOSSITE PLANSANITARY SEWER PLAN AND PROFILE03/03/2025 24015 LEHMRH0 SCALE: 1" = ORIGINAL GRAPHIC SCALE 25 50 100 50' LEGEND EXISTING STORM SEWER, MANHOLE, F.E.S. AND INLET PROPOSED STORM SEWER, MANHOLE, F.E.S. AND INLET EXISTING ROW PROPOSED ROW EXISTING LOT LINE PROPOSED LOT LINE PROPERTY BOUNDARY PROPERTY SETBACK EXISTING EASEMENT PROPOSED EASEMENT PROPOSED SANITARY SEWER W/ MH EXISTING SANITARY SEWER W/ MH PROPOSED UNDERDRAIN AND CLEANOUT PROPOSED WATER LINE, VALVE AND FIRE HYDRANT EXISTING WATER LINE AND VALVE PROPOSED WATER SERVICE W/ METER PROPOSED SANITARY SERVICE EXISTING GAS LINE EXISTING OVERHEAD ELECTRIC EXISTING ELECTRIC EXISTING CABLE TV EXISTING FIBER OPTIC EXISTING TELEPHONE EXISTING IRRIGATION CAUTION! UTILITY CROSSING LOWERING MAY BE REQUIRED EXISTING LIGHT POLE PROPOSED LIGHT POLEWSS NOTES: 1.CONTRACTOR SHALL FIELD VERIFY SIZE AND LOCATION OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION AND NOTIFY THE ENGINEER WITH ANY DISCREPANCIES. 2.CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL NECESSARY CONSTRUCTION STAKING. 3.INSTALL PERIMETER BMP'S PRIOR TO ANY CONSTRUCTION, SEE SHEET C4.0. 4.ALL TREES AND TREE ROOT ZONES OUTSIDE OF THE LIMITS OF CONSTRUCTION SHALL NOT BE DISTURBED. 5.ALL SANITARY SEWER SERVICES ARE 4" DIAMETER WITH 2% SLOPE AND A STANDARD 1.2' WYE CONNECTION TO THE 8" PRIVATE MAIN UNLESS OTHERWISE NOTED. 6.ALL SANITARY MAIN LINES SHALL MEET ASTM D1785 QUALITY STANDARD. 7.SOLVENT WELDED JOINTS MUST USE ASTM F656 PURPLE PRIMER AND ASTM D2564 CEMENT. 8.SEWER MUST BE INSTALLED BY OPEN-TRENCH ON A CONTINUOUS GRANULAR BED. 9.SEE SHEET C5.0 - C5.2 FOR CONSTRUCTION DETAILS. EXISTING FIRE HYDRANT LOCATED AT THE MID POINT OF NORTH PROPERTY LINE, TOP NUT OF HYDRANT =1026.02 SFST ST STWFWFWFWFWFWSSSSSSSFWFW EX. BOUNDARY (TYP) S ORONO INDUSTRIAL BOULEVARD OLD CRYSTALBAY ROADMNDOT RIGHT OF WAY PLAT NO 27-129 EX. 10.0' DRAINAGE & UTILITY EASEMENT EX. 10.0' DRAINAGE & UTILITY EASEMENT EX. 10.0' DRAINAGE & UTILITY EASEMENT EX. 22.0' DRAINAGE & UTILITY EASEMENT 20.0' SETBACK EX. 60.0' ROW EX. 66.0' ROW BUILDING 1 BUILDING 2 BUILDING 3 BUILDING 4 BUILDING 5 9+70 10+00 11+00 12+00 13+00 14+00 14+83BP: 9+70.00PI: 13+98.26EP: 14+82.58CB-1 4' SD STMH W/ R-3362-L GRATE N: 171,096.83 E: 445,696.75 CB-2 4' SD STMH W/ R-3362-L GRATE N: 171,094.80 E: 445,838.74 CB-3 4' SD STMH W/ R-3362-L GRATE N: 171,092.78 E: 445,980.74 24" DWPP 24" DWPP 36" DWPP PROPOSED 8" SANITARY (TYP) PROPOSED SANITARY MH (TYP) PROPOSED POND. SEE SHEET C4.5. EX. STORM SEWER (TYP) PROPOSED 8" WATER (TYP) EX. 10.00' DRAINAGE & UTILITY EASEMENT PROPOSED FOREBAY. SEE SHEET C4.5. PROPOSED GRADE @ STORM ℄ EXISTING GROUND @ STORM ℄ ALIGNMENT NAME: Storm 1 PROFILE HORIZONTAL SCALE: 50.00 VERTICAL SCALE: 5.00 GRAPH VERTICAL EXAGGERATION: 10.00 STATION RANGE: 9+50 - 15+50 PROFILE VIEW ELEVATION RANGE: 1010.00 - 1035.00 1010 1015 1020 1025 1030 1035 1010 1015 1020 1025 1030 1035 9+50 10+00 11+00 12+00 13+00 14+00 15+00 15+50 142.0 LF~24" DWPP @ 0.50% 142.0 LF~24" DWPP @ 0.50% 22.0 LF~36" DWPP @ 0.50% CB-1 4' SD STMH W/ R-3362-L GRATE RIM:1023.14± INV OUT:1019.64 (24" PVC) (E) CUT=3.5± CB-2 4' SD STMH W/ R-3362-L GRATE RIM:1022.42± INV IN:1018.93 (24" PVC) (W) INV OUT:1018.73 (24" PVC) (E) CUT=3.7± CB-3 4' SD STMH W/ R-3362-L GRATE RIM:1021.71± INV IN:1018.02 (24" PVC) (W) INV OUT:1017.21 (36" PVC) (E) CUT=4.5± I HEREBY CERTIFY THAT THIS PLAN WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION, AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA. SIGNATURE: __________________________________________TYPED OR PRINTED NAME: MATTHEW R. HAGSTROM DATE: 03/03/2025 LICENSE NUMBER: 50731 Designed By:Date: Job No.: FOR AND ON BEHALF OF HAGSTROM ENGINEERING PLLC Checked By:811 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL GOPHER STATE ONE CALL BENCHMARK:ByDateDescription of RevisionsNo.Sheet of D C B A 54321 219 6TH AVENUE EAST ALEXANDRIA, MN 56308 P.320.759.0764 WWW.HAGSTROMENG.COM HAGSTROM ENGINEERING CIVIL ENGINEERS | LAND CONSULTANTS CAUTION: IF THIS SHEET IS NOT 24"X36" IT IS A REDUCED PRINT C5.2C3.3 C3.3ORONO GARAGE CONDOSSITE PLANSTORM SEWER PLAN AND PROFILE03/03/2025 24015 LEHMRH0 SCALE: 1" = ORIGINAL GRAPHIC SCALE 25 50 100 50' LEGEND EXISTING STORM SEWER, MANHOLE, F.E.S. AND INLET PROPOSED STORM SEWER, MANHOLE, F.E.S. AND INLET EXISTING ROW PROPOSED ROW EXISTING LOT LINE PROPOSED LOT LINE PROPERTY BOUNDARY PROPERTY SETBACK EXISTING EASEMENT PROPOSED EASEMENT PROPOSED SANITARY SEWER W/ MH EXISTING SANITARY SEWER W/ MH PROPOSED UNDERDRAIN AND CLEANOUT PROPOSED WATER LINE, VALVE AND FIRE HYDRANT EXISTING WATER LINE AND VALVE PROPOSED WATER SERVICE W/ METER PROPOSED SANITARY SERVICE EXISTING GAS LINE EXISTING OVERHEAD ELECTRIC EXISTING ELECTRIC EXISTING CABLE TV EXISTING FIBER OPTIC EXISTING TELEPHONE TYPICAL CAUTION! UTILITY CROSSING LOWERING MAY BE REQUIRED EXISTING LIGHT POLE PROPOSED LIGHT POLEWSS NOTES: 1.CONTRACTOR SHALL FIELD VERIFY SIZE AND LOCATION OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION AND NOTIFY THE ENGINEER WITH ANY DISCREPANCIES. 2.CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL NECESSARY CONSTRUCTION STAKING. 3.INSTALL PERIMETER BMP'S PRIOR TO ANY CONSTRUCTION, SEE SHEET C4.0. 4.ALL TREES AND TREE ROOT ZONES OUTSIDE OF THE LIMITS OF CONSTRUCTION SHALL NOT BE DISTURBED. 5.ALL STORM SEWER SHALL BE PRIVATE ADS DUAL WALL HIGH PERFORMANCE POLYPROPYLENE PIPE. 6.ALL CATCH BASINS SHALL BE PRIVATE 48" SHALLOW DEPTH W/ R-3362 VALLEY GRATE. 7.STORM SEWER MUST BE INSTALLED BY OPEN-TRENCH ON A CONTINUOUS GRANULAR BED. 8.SEE SHEET C5.0 - C5.2 FOR CONSTRUCTION DETAILS. TYP EXISTING FIRE HYDRANT LOCATED AT THE MID POINT OF NORTH PROPERTY LINE, TOP NUT OF HYDRANT =1026.02 OLD CRYSTAL BAY ROADMNDOT RIGHT OF WAY PLAT NO 27-129 WJM PROPERTIES LLC PID: 3311823130015 ORONO PRESERVE DEVELOPMENT ORONO INDUSTRIAL BOULEVARD ST ST ST PROPOSED IMPROVEMENTS SHOWN AS EXISTING EX. BOUNDARY EX. BOUNDARY 1021 1017102310231021 1025 1020 1020 1027 10261028 1028102810261019 1018 10241026 1023. 9 7 1023. 7 7 1023.14 1022.42 1021.71 1021. 6 2 1025. 2 5 1025. 2 5 1024.59 1023. 8 7 1023. 1 7 1023. 1 5 PROPOSED BUILDING 1 FFE = 1025.79 PROPOSED BUILDING 2 FFE = 1026.00 PROPOSED BUILDING 3 FFE = 1025.06 PROPOSED BUILDING 4 FFE = 1024.35 PROPOSED BUILDING 5 FFE = 1023.68 1025.87 ME 1025.34 ME 1025.12 TOC 1025.04 TOC 1020.46 TOW 4.1% 7.3% 5.8% 5.6% 7.3% 5.0% 3.1% 4.7% 7.6% 4.4% 5.6% 4.5% 7.6% 5.2% 4.7%0.5%0.5%0.6%0.5%0.5%0.5%0.5%0.5%0.5%0.5%0.5%0.5%0.5%0.5%0.5%0.5% 2.0%12.2%10.0% 10.5% 10.5%10.0%33.3%33.3% 33.3%3.8%10216.1%11.2%3.6%3.4%2.1%3.3%2.1%2.1%2.1%2.1%33.3%1.8%2.1%8.3%7.5%6.9%3.4%2.0%0.1%SF SF SF SF SF IP IP VTC CWA 1 0 2 2 1021 33.3%33.0%2.0%4.0%2.1%4.3%3.6%3.1%3.9%2.3% PROPOSED BUILDING 1 FFE = 1025.12 PROPOSED BUILDING 2 FFE = 1025.33 PROPOSED BUILDING 2 FFE = 1025.33 PROPOSED BUILDING 2 FFE = 1024.66 PROPOSED BUILDING 3 FFE = 1023.72 PROPOSED BUILDING 3 FFE = 1024.39 PROPOSED BUILDING 4 FFE = 1023.67 PROPOSED BUILDING 4 FFE = 1023.01 PROPOSED BUILDING 5 FFE = 1023.01 PROPOSED BUILDING 5 FFE = 1022.34 8" STEP 8" STEP 8" STEP 8" STEP 8" STEP 8" STEP 8" STEP 8" STEP 8" STEP 2.1%2.3% IP IP IP 4.5% 2.7% 3.3% 7.6%10241024 1021 IP HP 1025.33 1019.21 BOW 1020.69 TOW 1018.55 BOW 1021.05 TOW 1018.75 BOW 1021.37 TOW 1018.92 BOW 1021.00 TOW 1019.02 BOW ??? TOW ??? BOW ECB ECB 1026.11 1025.76 1025.30 I HEREBY CERTIFY THAT THIS PLAN WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION, AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA. SIGNATURE: __________________________________________TYPED OR PRINTED NAME: MATTHEW R. HAGSTROM DATE: 03/03/2025 LICENSE NUMBER: 50731 Designed By:Date: Job No.: FOR AND ON BEHALF OF HAGSTROM ENGINEERING PLLC Checked By:811 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL GOPHER STATE ONE CALL BENCHMARK:ByDateDescription of RevisionsNo.Sheet of D C B A 54321 219 6TH AVENUE EAST ALEXANDRIA, MN 56308 P.320.759.0764 WWW.HAGSTROMENG.COM HAGSTROM ENGINEERING CIVIL ENGINEERS | LAND CONSULTANTS CAUTION: IF THIS SHEET IS NOT 24"X36" IT IS A REDUCED PRINT C5.0C4.0 C4.0ORONO GARAGE CONDOSSITE PLANPROPOSED GRADING & EROSIONCONTROL PLAN03/03/2025 24015 LEHMRH0 SCALE: 1" = ORIGINAL GRAPHIC SCALE 15 30 60 30' GRADING NOTES: 1.CONTRACTOR SHALL FIELD VERIFY SIZE AND LOCATION OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION AND NOTIFY THE ENGINEER WITH ANY DISCREPANCIES. 2.CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL NECESSARY CONSTRUCTION STAKING. 3.ALL ELEVATIONS ARE FLOWLINE UNLESS OTHERWISE NOTED 4.INSTALL PERIMETER BMP'S PRIOR TO ANY CONSTRUCTION. 5.ALL TREES AND TREE ROOT ZONES OUTSIDE OF THE LIMITS OF CONSTRUCTION SHALL NOT BE DISTURBED. 6.SEE SHEET C5.0 FOR CONSTRUCTION DETAILS. LEGEND EXISTING 1' AND 5' CONTOURS PROPOSED 1' AND 5' CONTOURS PROPOSED SPOT ELEVATION FLOW DIRECTION & GRADE FINISHED FLOOR ELEVATION MATCH EXISTING TOP OF CONCRETE HIGH POINT TOP OF WALL BOTTOM OF WALL LIMITS OF DISTURBANCE SILT FENCE 1,000 LF INLET PROTECTION 5 EA VEHICLE TRACKING CONTROL 1 EA EROSION CONTROL BLANKET 550 SY CONCRETE WASHOUT AREA 1 EA FFE ME TOC HP TOW BOW 1432. 3 1431 1430 1431 1430 2.00% EROSION CONTROL NOTES: 1.INSTALL PERIMETER BMP'S PRIOR TO ANY CONSTRUCTION. 2.SEE SHEET C5.0 FOR BMP DETAILS AND BMP MAINTENANCE NOTES. 3.THE CONTRACTOR SHALL PERFORM STREET SWEEPING AT THE END OF EACH WORK DAY TO MITIGATE ANY SOIL ON PERIMETER STREETS. 4.THE CONTRACTOR SHALL INSPECT THE BMP'S WEEKLY OR AFTER ANY SIGNIFICANT RAIN EVENT AND REPAIR BMP'S AS REQUIRED. 5.STOCKPILE AND STAGING LOCATION TO BE APPROVED BY ENGINEER. 6.ALL DISTURBED AREAS THAT ARE NOT HARDSCAPED SHALL RECEIVE PERMANENT STABILIZATION PER LANDSCAPE PLAN. 7.SEE SWPPP DOCUMENT BY HAGSTROM ENGINEERING FOR SEEDING, INSPECTION, AND MAINTENANCE REQUIREMENTS. . SF IP VTC CWA ECB EXISTING FIRE HYDRANT LOCATED AT THE MID POINT OF NORTH PROPERTY LINE, TOP NUT OF HYDRANT =1026.02 10251028 1026 PROPOSED BUILDING 1 FFE = 1025.79 PROPOSED BUILDING 2 FFE = 1026.00 1025.79 TOC 1025.71 TOC 1025.92 TOC 1026.00 TOC 1025.12 TOC 1025.04 TOC 1025.25 TOC 1025.33 TOC 1024.66 TOC 1024.58 TOC 1025.25 TOC 1025.33 TOC1.3%2.0%2.0%2.0%12.2%10.0%23.4%10.5%10.0% 4.0% 6.1% 11.2% 5.4%10221025.12 TOC 1025.79 TOC PROPOSED BUILDING 1 FFE = 1025.12 PROPOSED BUILDING 2 FFE = 1025.33 PROPOSED BUILDING 2 FFE = 1025.33 PROPOSED BUILDING 2 FFE = 1024.66 1025.71 TOC1025.09 TOC 1025.92 TOC 1026.00 TOC 1025.25 TOC 1025.33 TOC 1025.33 TOC 1025.25 TOC 1024.64 TOC 1024.66 TOC 8" STEP 8" STEP 8" STEP2.0%10241025.12 TOC 1025.06 TOC 1025.12 TOC 1025.07 TOC 1025.12 TOC 1025.08 TOC 1025.12 TOC 1025.08 TOC 1025.21 TOA 1025.21 TOA 6" STEP 1025.71 TOC 1025.79 TOC 0.7%2.0%1025.79 TOC 1025.71 TOC 1025.79 TOC 1025.71 TOC2.0%2.0%1025.79 TOC 1025.71 TOC 1024.70 1025.20 1025.20 1024.70 1025.201024.50 1024.00 10.5%2.1%2.6%1024.50 1024.00 1025.25 TOC 1025.33 TOC 2.0%2.0%2.0%2.0%2.0%1025.42 TOA 6" STEP 1025.25 TOC 1025.33 TOC 1025.25 TOC 1025.33 TOC 1025.92 TOC 1026.00 TOC 1025.92 TOC 1026.00 TOC 1025.92 TOC 1026.00 TOC 1024.66 TOC 1024.59 TOC 1024.66 TOC 1024.61 TOC 1024.66 TOC 1024.63 TOC 1025.33 TOC 1025.25 TOC 1025.33 TOC 1025.25 TOC1.2%1.2%2.0%0.5%2.0%1024.75 TOA 1024.83 TOA 1025.50 TOA 2.0%6" STEP I HEREBY CERTIFY THAT THIS PLAN WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION, AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA. SIGNATURE: __________________________________________TYPED OR PRINTED NAME: MATTHEW R. HAGSTROM DATE: 03/03/2025 LICENSE NUMBER: 50731 Designed By:Date: Job No.: FOR AND ON BEHALF OF HAGSTROM ENGINEERING PLLC Checked By:811 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL GOPHER STATE ONE CALL BENCHMARK:ByDateDescription of RevisionsNo.Sheet of D C B A 54321 219 6TH AVENUE EAST ALEXANDRIA, MN 56308 P.320.759.0764 WWW.HAGSTROMENG.COM HAGSTROM ENGINEERING CIVIL ENGINEERS | LAND CONSULTANTS CAUTION: IF THIS SHEET IS NOT 24"X36" IT IS A REDUCED PRINT C5.0C4.1 C4.1ORONO GARAGE CONDOSSITE PLANDETAILED GRADING PLANBUILDING 1 & 203/03/2025 24015 LEHMRH0 SCALE: 1" = ORIGINAL GRAPHIC SCALE 5 10 20 10' GRADING NOTES: 1.CONTRACTOR SHALL FIELD VERIFY SIZE AND LOCATION OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION AND NOTIFY THE ENGINEER WITH ANY DISCREPANCIES. 2.CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL NECESSARY CONSTRUCTION STAKING. 3.ALL ELEVATIONS ARE FLOWLINE UNLESS OTHERWISE NOTED 4.INSTALL PERIMETER BMP'S PRIOR TO ANY CONSTRUCTION. 5.ALL TREES AND TREE ROOT ZONES OUTSIDE OF THE LIMITS OF CONSTRUCTION SHALL NOT BE DISTURBED. 6.SEE SHEET C5.0 FOR CONSTRUCTION DETAILS. LEGEND EXISTING 1' AND 5' CONTOURS PROPOSED 1' AND 5' CONTOURS PROPOSED SPOT ELEVATION FLOW DIRECTION & GRADE 1432. 3 1431 1430 1431 1430 2.00% FINISHED FLOOR ELEVATION MATCH EXISTING TOP OF CONCRETE TOP OF ASPHALT HIGH POINT TOP OF WALL BOTTOM OF WALL FFE ME TOC TOA HP TOW BOW EXISTING FIRE HYDRANT LOCATED AT THE MID POINT OF NORTH PROPERTY LINE, TOP NUT OF HYDRANT =1026.02 PROPOSED BUILDING 3 FFE = 1025.06 1025.06 TOC 1024.98 TOC 1023.64 TOC 1023.72 TOC 1023.72 TOC 1023.64 TOC 1025.06 TOC 1024.98 TOC2.0%2.0%2.0%12.7% 3.6% PROPOSED BUILDING 3 FFE = 1023.72 1024.39 TOC PROPOSED BUILDING 3 FFE = 1024.39 1024.31 TOC 1024.98 TOC 1025.06 TOC 1024.31 TOC 1024.39 TOC 1024.39 TOC 1024.31 TOC 1025.06 TOC 1024.98 TOC 1024.31 TOC 1024.39 TOC 1023.64 TOC 1023.72 TOC 1023.68 TOC 1023.72 TOC 8" STEP 8" STEP2.0%1024.31 TOC 1024.39 TOC 1024.31 TOC 1024.39 TOC 1024.98 TOC 1025.06 TOC 1024.98 TOC 1025.06 TOC2.0%2.0%2.0%2.0%1024.48 TOA 1024.57 TOA 6" STEP6" STEP 1023.81 TOA 1023.89 TOA 1024.39 TOC 1024.31 TOC 1024.39 TOC 1024.31 TOC 1025.06 TOC 1024.98 TOC 1025.06 TOC 1024.98 TOC 2.0%2.0%2.0%2.0%2.0%1024.48 TOA 1024.56 TOA 1023.81 TOA 1023.89 TOA 6" STEP6" STEP 2.0%8" STEP 8" STEP I HEREBY CERTIFY THAT THIS PLAN WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION, AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA. SIGNATURE: __________________________________________TYPED OR PRINTED NAME: MATTHEW R. HAGSTROM DATE: 03/03/2025 LICENSE NUMBER: 50731 Designed By:Date: Job No.: FOR AND ON BEHALF OF HAGSTROM ENGINEERING PLLC Checked By:811 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL GOPHER STATE ONE CALL BENCHMARK:ByDateDescription of RevisionsNo.Sheet of D C B A 54321 219 6TH AVENUE EAST ALEXANDRIA, MN 56308 P.320.759.0764 WWW.HAGSTROMENG.COM HAGSTROM ENGINEERING CIVIL ENGINEERS | LAND CONSULTANTS CAUTION: IF THIS SHEET IS NOT 24"X36" IT IS A REDUCED PRINT C5.0C4.2 C4.2ORONO GARAGE CONDOSSITE PLANDETAILED GRADING PLANBUILDING 303/03/2025 24015 LEHMRH0 SCALE: 1" = ORIGINAL GRAPHIC SCALE 5 10 20 10' GRADING NOTES: 1.CONTRACTOR SHALL FIELD VERIFY SIZE AND LOCATION OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION AND NOTIFY THE ENGINEER WITH ANY DISCREPANCIES. 2.CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL NECESSARY CONSTRUCTION STAKING. 3.ALL ELEVATIONS ARE FLOWLINE UNLESS OTHERWISE NOTED 4.INSTALL PERIMETER BMP'S PRIOR TO ANY CONSTRUCTION. 5.ALL TREES AND TREE ROOT ZONES OUTSIDE OF THE LIMITS OF CONSTRUCTION SHALL NOT BE DISTURBED. 6.SEE SHEET C5.0 FOR CONSTRUCTION DETAILS. LEGEND EXISTING 1' AND 5' CONTOURS PROPOSED 1' AND 5' CONTOURS PROPOSED SPOT ELEVATION FLOW DIRECTION & GRADE 1432. 3 1431 1430 1431 1430 2.00% FINISHED FLOOR ELEVATION MATCH EXISTING TOP OF CONCRETE TOP OF ASPHALT HIGH POINT TOP OF WALL BOTTOM OF WALL FFE ME TOC TOA HP TOW BOW EXISTING FIRE HYDRANT LOCATED AT THE MID POINT OF NORTH PROPERTY LINE, TOP NUT OF HYDRANT =1026.02 PROPOSED BUILDING 4 FFE = 1024.35 2.0%12.7% 3.4% PROPOSED BUILDING 4 FFE = 1023.67 PROPOSED BUILDING 4 FFE = 1023.01 8" STEP 8" STEP 2.0%1024.35 TOC 1024.27 TOC 1022.93 TOC 1023.01 TOC 2.0%1023.68 TOC 1023.60 TOC 1024.27 TOC 1024.35 TOC 1023.60 TOC 1023.68 TOC 1022.99 TOC 0.6% 1023.60 TOC 1023.68 TOC 1023.60 TOC 1023.68 TOC 1024.27 TOC 1024.35 TOC 1024.27 TOC 1024.35 TOC2.0%2.0%2.0%2.0%1023.77 TOA 1023.85 TOA 6" STEP6" STEP 1023.10 TOA 1023.18 TOA 2.0%1023.01 TOC 1022.93 TOC 1024.35 TOC 1024.27 TOC2.0%2.0%1023.68 TOC 1023.60 TOC 1024.35 TOC 1024.27 TOC 1023.60 TOC 1023.68 TOC 1022.93 TOC 1023.01 TOC 1023.68 TOC 1023.60 TOC 1023.68 TOC 1023.60 TOC 1024.35 TOC 1024.27 TOC 1024.35 TOC 1024.27 TOC 2.0%2.0%2.0%2.0%1023.77 TOA 1023.85 TOA 1023.10 TOA 1023.18 TOA 6" STEP6" STEP 2.0%8" STEP 8" STEP I HEREBY CERTIFY THAT THIS PLAN WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION, AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA. SIGNATURE: __________________________________________TYPED OR PRINTED NAME: MATTHEW R. HAGSTROM DATE: 03/03/2025 LICENSE NUMBER: 50731 Designed By:Date: Job No.: FOR AND ON BEHALF OF HAGSTROM ENGINEERING PLLC Checked By:811 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL GOPHER STATE ONE CALL BENCHMARK:ByDateDescription of RevisionsNo.Sheet of D C B A 54321 219 6TH AVENUE EAST ALEXANDRIA, MN 56308 P.320.759.0764 WWW.HAGSTROMENG.COM HAGSTROM ENGINEERING CIVIL ENGINEERS | LAND CONSULTANTS CAUTION: IF THIS SHEET IS NOT 24"X36" IT IS A REDUCED PRINT C5.0C4.3 C4.3ORONO GARAGE CONDOSSITE PLANDETAILED GRADING PLANBUILDING 403/03/2025 24015 LEHMRH0 SCALE: 1" = ORIGINAL GRAPHIC SCALE 5 10 20 10' GRADING NOTES: 1.CONTRACTOR SHALL FIELD VERIFY SIZE AND LOCATION OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION AND NOTIFY THE ENGINEER WITH ANY DISCREPANCIES. 2.CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL NECESSARY CONSTRUCTION STAKING. 3.ALL ELEVATIONS ARE FLOWLINE UNLESS OTHERWISE NOTED 4.INSTALL PERIMETER BMP'S PRIOR TO ANY CONSTRUCTION. 5.ALL TREES AND TREE ROOT ZONES OUTSIDE OF THE LIMITS OF CONSTRUCTION SHALL NOT BE DISTURBED. 6.SEE SHEET C5.0 FOR CONSTRUCTION DETAILS. LEGEND EXISTING 1' AND 5' CONTOURS PROPOSED 1' AND 5' CONTOURS PROPOSED SPOT ELEVATION FLOW DIRECTION & GRADE 1432. 3 1431 1430 1431 1430 2.00% FINISHED FLOOR ELEVATION MATCH EXISTING TOP OF CONCRETE TOP OF ASPHALT HIGH POINT TOP OF WALL BOTTOM OF WALL FFE ME TOC TOA HP TOW BOW EXISTING FIRE HYDRANT LOCATED AT THE MID POINT OF NORTH PROPERTY LINE, TOP NUT OF HYDRANT =1026.02 ST1017 10231023 1020PROPOSED BUILDING 5 FFE = 1023.68 1023.68 TOC 1022.34 TOC 2.0%2.0%33.3%33.3%33.3%1021 PROPOSED BUILDING 5 FFE = 1023.01 PROPOSED BUILDING 5 FFE = 1022.34 8" STEP 8" STEP 1023.60 TOC 1022.26 TOC 2.0%1023.01 TOC 1022.93 TOC 1023.60 TOC 1023.68 TOC 1022.93 TOC 1023.01 TOC 1022.26 TOC 2.0%1022.93 TOC 1023.01 TOC 1022.93 TOC 1023.01 TOC 1023.60 TOC 1023.68 TOC 1023.60 TOC 1023.68 TOC2.0%2.0%2.0%2.0%1023.10 TOA 1023.18 TOA 6" STEP6" STEP 1022.43 TOA 1022.51 TOA 2.0%1021.50 1021.501021.501021.501021.50 EXPOSE FOUNDATIONEXPOSE FOUNDATION 1023.60 TOC 1023.68 TOC BOW=1022.00 1022.99 I HEREBY CERTIFY THAT THIS PLAN WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION, AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA. SIGNATURE: __________________________________________TYPED OR PRINTED NAME: MATTHEW R. HAGSTROM DATE: 03/03/2025 LICENSE NUMBER: 50731 Designed By:Date: Job No.: FOR AND ON BEHALF OF HAGSTROM ENGINEERING PLLC Checked By:811 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL GOPHER STATE ONE CALL BENCHMARK:ByDateDescription of RevisionsNo.Sheet of D C B A 54321 219 6TH AVENUE EAST ALEXANDRIA, MN 56308 P.320.759.0764 WWW.HAGSTROMENG.COM HAGSTROM ENGINEERING CIVIL ENGINEERS | LAND CONSULTANTS CAUTION: IF THIS SHEET IS NOT 24"X36" IT IS A REDUCED PRINT C5.0C4.4 C4.4ORONO GARAGE CONDOSSITE PLANDETAILED GRADING PLANBUILDING 503/03/2025 24015 LEHMRH0 SCALE: 1" = ORIGINAL GRAPHIC SCALE 5 10 20 10' GRADING NOTES: 1.CONTRACTOR SHALL FIELD VERIFY SIZE AND LOCATION OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION AND NOTIFY THE ENGINEER WITH ANY DISCREPANCIES. 2.CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL NECESSARY CONSTRUCTION STAKING. 3.ALL ELEVATIONS ARE FLOWLINE UNLESS OTHERWISE NOTED 4.INSTALL PERIMETER BMP'S PRIOR TO ANY CONSTRUCTION. 5.ALL TREES AND TREE ROOT ZONES OUTSIDE OF THE LIMITS OF CONSTRUCTION SHALL NOT BE DISTURBED. 6.SEE SHEET C5.0 FOR CONSTRUCTION DETAILS. LEGEND EXISTING 1' AND 5' CONTOURS PROPOSED 1' AND 5' CONTOURS PROPOSED SPOT ELEVATION FLOW DIRECTION & GRADE 1432. 3 1431 1430 1431 1430 2.00% FINISHED FLOOR ELEVATION MATCH EXISTING TOP OF CONCRETE TOP OF ASPHALT HIGH POINT TOP OF WALL BOTTOM OF WALL FFE ME TOC TOA HP TOW BOW EXISTING FIRE HYDRANT LOCATED AT THE MID POINT OF NORTH PROPERTY LINE, TOP NUT OF HYDRANT =1026.02 STSTST10191018PROPOSED BUILDING 5 FFE = 1023.68 PROPOSED BUILDING 5 FFE = 1023.01 PROPOSED BUILDING 5 FFE = 1022.34 WJM PROPERTIES LLC PID: 3311823130015 MNDOT RIGHT OF WAY PLAT NO 27-129 1023 1 0 2 2 1 0 2 1 1020 101 9 1 0 1 8 10161015101610181023 EX. 22.00' DRAINAGE & UTILITY EASEMENT AA4" SCH 40 PVC CLEANOUT W/ WATERTIGHT CAP RIM=1016.81 INV=1015.35 N: 171,093.28 E: 446,059.81 4" SCH 40 PVC CLEANOUT W/ WATERTIGHT CAP RIM=1016.81 INV=1014.71 N: 171,222.63 E: 446,062.03 4" SCH 40 PVC CLEANOUT W/ WATERTIGHT CAP RIM=1016.81 INV=1015.56 N: 171,093.98 E: 446,018.76 1016EX. 48" RCP FOREBAY. SEE DETAIL THIS SHEET 1 CY CLASS II RIPRAP 129.4 LF ~ 4" SDR35 PERF. PVC @ 0.5% 10.9 LF ~ 4" SDR35 PVC @ 0.5% STORM SEWER. SEE SHEET C3.3. 1023.15 1018.73 1017.47 1017.00 1023.68 1021.50 1021.50 1022.34 1022.090.5%0.5%0.5%0.5%33.3%33.3%33.3%3.8 %10211017 102310231022 102010211021 102010 2 1 101810221020 1022 1018 10211023 1021 33.3%33.3%33.4%28.5%30.5% 33.3%33.3%21.8%8.2%1019 1019 EX. FES INV.= 1014.3 POND BERM (TYP) EMERGENCY SPILLWAY. SEE DETAIL THIS SHEET. 41.1 LF ~ 4" SDR35 PERF. PVC @ 0.5% OUTLET STRUCTURE SEE DETAIL THIS SHEET EXISTING PIPE TO BE REMOVED WITHIN STRUCTURE 62 LF LANDSCAPE WALL 1020.14 TOW 1017.20 BOW 1020.21 TOW 1018.00 BOW 1017.70 TOW 1017.20 BOW EX. 48" RCP EX. STMH WQCV WSEL=1020.87EX. STMH SOUTH SWALE SEE SECTION THIS SHEET NORTH SWALE SEE SECTION THIS SHEET 1021.62 EMERGENCY SPILLWAY N.T.S 2.0'10.0'2.0' EL=1022.0 EL=1021.5 EL=1022.0 WQCV WSEL = 1020.87 MNDOT CATEGORY 90 ROLLED EROSION PREVENTION PRODUCT CONCRETE FOREBAY N.T.S SECTION A-A FILTRATION POND N.T.S. 9.1' POND BOTTOM 1.0' BERM EL=1022.0 MATCH EXISTINGEXISTING GROUND PROPOSED GRADE BOTTOM OF POND EL=1017.0 WQCV WSEL = 1020.87 4.0' SAND AND FILTER MATERIAL 4" PERF. PVC 3:1 MAX UNDERDRAIN DETAIL N.T.S 4"Ø PERFORATED PVC UNDERDRAIN @ 0.5% UNDERDRAIN FLOW DIRECTION 6" MIN. DEPTH MEDIA MIX D 60% COARSE SAND 25% TOPSOIL 15% COMPOST (MnDOT GRADE 2) 4"Ø PVC @ 0.5% 4"Ø STORM CLEANOUT W/ WATERTIGHT CAP 4"Ø STORM CLEANOUT W/ WATERTIGHT CAP 3" #57 STONE, WASHED 2" #8 STONE OUTLET STRUCTURE SOUTH FACE N.T.S 6' X 6' PRECAST BOX W/ REINFORCEMENT BOTTOM OF BOX = 1013.55 7.32' 0.5' 0.5' 7.82' TOP OF BOX = 1020.87 6.0' INLET GRATE (CLOSE MESH) RACK SWIVEL REBAR HINGE IN BACK BOLT DOWN OR LOCK DOWN IN FRONT EX. 48" RCP INV IN & OUT = 1014.47 4" PVC INV IN = 1014.65 OUTLET STRUCTURE 12.0' CLASS II RIPRAP PIPE FLOW CONCRETE HEADWALL TOP EL = 1021.0 BOTTOM EL = 1015.0 0.5' PIPE INV = 1017.0 0.5' INV = 1016.9 MNDOT CATEGORY 70 ROLLED EROSION PREVENTION PRODUCT 4.0' SWALE 10% SLOPE 2-YR DEPTH=0.19' 0.20' SWALE DEPTH MNDOT CL II RIPRAP 4.0' SWALE4% SLOPE 2-YR DEPTH=0.05' 0.08' SWALE DEPTH NORTH SWALE N.T.S SOUTH SWALE N.T.S I HEREBY CERTIFY THAT THIS PLAN WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION, AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA. SIGNATURE: __________________________________________TYPED OR PRINTED NAME: MATTHEW R. HAGSTROM DATE: 03/03/2025 LICENSE NUMBER: 50731 Designed By:Date: Job No.: FOR AND ON BEHALF OF HAGSTROM ENGINEERING PLLC Checked By:811 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL GOPHER STATE ONE CALL BENCHMARK:ByDateDescription of RevisionsNo.Sheet of D C B A 54321 219 6TH AVENUE EAST ALEXANDRIA, MN 56308 P.320.759.0764 WWW.HAGSTROMENG.COM HAGSTROM ENGINEERING CIVIL ENGINEERS | LAND CONSULTANTS CAUTION: IF THIS SHEET IS NOT 24"X36" IT IS A REDUCED PRINT C5.0C4.5 C4.5ORONO GARAGE CONDOSSITE PLANDETAILED POND PLAN03/03/2025 24015 LEHMRH0 SCALE: 1" = ORIGINAL GRAPHIC SCALE 10 20 40 20' LEGEND EXISTING STORM SEWER PROPOSED STORM SEWER PROPERTY BOUNDARY LOT LINE EXISTING EASEMENT LINE EXISTING 1' AND 5' CONTOURS PROPOSED 1' AND 5' CONTOURS FLOW DIRECTION & GRADE WATER SURFACE ELEVATION TOP OF WALL BOTTOM OF WALL PROPOSED DRAINAGE SWALE WSEL TOW BOW 1411 1410 1411 1410 2.00% NOTES: 1.CONTRACTOR SHALL FIELD VERIFY SIZE AND LOCATION OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION AND NOTIFY THE ENGINEER WITH ANY DISCREPANCIES. 2.INSTALL PERIMETER BMPs PRIOR TO ANY CONSTRUCTION. 3.ALL ELEVATIONS PROVIDED ARE FINISHED GRADE UNLESS OTHERWISE NOTED. 4.SEE SHEETS C5.0 - C5.2 FOR CONSTRUCTION DETAILS. POND NOTES: 1.TO AVOID OVER-COMPACTION OF THE POND, AFTER GRADING THE POND, DO NOT DRIVE HEAVY EQUIPMENT OVER THE POND AREA. 2.THE POND MAY BE UTILIZED AS TEMPORARY SEDIMENTATION BASINS DURING CONSTRUCTION. ALL CONSTRUCTION DEBRIS AND SEDIMENTATION SHALL BE REMOVED FROM POND PRIOR TO FINAL STABILIZATION. 3.REFER TO THE STORMWATER POLLUTION PREVENTION PLAN (SWPPP) FOR ORONO GARAGE CONDOS BY HAGSTROM ENGINEERING FOR CONSTRUCTION RELATED BEST MANAGEMENT PRACTICES TO REDUCE SEDIMENT AND EROSION CONTROL. 4.OPERATION AND MAINTENANCE OF THE POND IS REQUIRED FOR LONG-TERM FUNCTIONALITY OF THE POND. PLEASE SEE THE POND OPERATION AND MAINTENANCE PLAN AND CHECKLIST THAT IS INCLUDED IN THE FINAL DRAINAGE REPORT FOR ORONO GARAGE CONDOS BY HAGSTROM ENGINEERING. EXISTING FIRE HYDRANT LOCATED AT THE MID POINT OF NORTH PROPERTY LINE, TOP NUT OF HYDRANT =1026.02 Designed By:Date: Job No.: FOR AND ON BEHALF OF HAGSTROM ENGINEERING PLLC Checked By:811 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL GOPHER STATE ONE CALL BENCHMARK:ByDateDescription of RevisionsNo.Sheet of D C B A 54321 219 6TH AVENUE EAST ALEXANDRIA, MN 56308 P.320.759.0764 WWW.HAGSTROMENG.COM HAGSTROM ENGINEERING CIVIL ENGINEERS | LAND CONSULTANTS CAUTION: IF THIS SHEET IS NOT 24"X36" IT IS A REDUCED PRINT C5.0C5.0 C5.0ORONO GARAGE CONDOSSITE PLANCONSTRUCTION DETAILS03/03/2025 24015 LEHMRHHEAVY DUTY BITUMINOUS PAVEMENT SECTION* N.T.S. 2" WEAR COURSE MIXTURE SPWEA340C 2" NON-WEARING COURSE MIXTURE SPNWA340C 10" AGGREGATE BASE CLASS 5 TACK COAT PER MNDOT 2357 COMPACTED SUBGRADE 3.00' 6" 1" CONCRETE V-PAN DETAIL N.T.S. * PAVEMENT SECTION BASED ON RECOMMENDATION OF GEOTECHNICAL ENGINEER. FINAL APPROVAL OF PAVEMENT SECTION PER OWNER. DEFINITION A DESIGNATED, SHALLOW EXCAVATION WITH A PERIMETER BERM, SILT FENCE, AND VTC, DESIGNED FOR CONCRETE WASHOUT OPERATIONS. PURPOSE TO CONTAIN WASTE FROM CONCRETE TRUCKS, SMALL BATCH CONCRETE MIXERS, PUMP TRUCKS, AND OTHER WASHOUT OPERATIONS. 8'x8' MIN. 3:13:1 9' MIN. 1' MIN. 8'x8' MIN.9' MIN. 3:1 3:1 1' MIN. 2% VEHICLE TRACKING CONTROL. SEE DETAIL VTC. VEHICLE TRACKING CONTROL. SEE DETAIL VTC SILT FENCE AROUND EARTH BERM. SEE DETAIL SF. SILT FENCE AROUND EARTH BERM. SEE DETAIL SF. 3' MIN. EXISTING GRADE COMPACTED EMBANKMENT MATERIAL CONSTRUCTION SIGN (MANDATORY) CONCRETE WASHOUT AREA N.T.S. CWA INSTALL POLY LINER DEFINITION A TEMPORARY SEDIMENT BARRIER PLACED ON-GRADE. PURPOSE TO INCREASE SEDIMENTATION FROM SEDIMENT LADEN RUNOFF AND SLOW THE VELOCITY OF STORM RUNOFF. NOTES 1.SEE DETAIL CS FOR ROCK SOCKS USED IN CURB FLOW LINE. 2.SEE DETAIL IP FOR ROCK SOCKS (CURB SOCK) USED AS ON-GRADE CURB INLET PROTECTION. 3.SEE DETAIL IP-A FOR ROCK SOCKS USED AS SUMP CURB INLET PROTECTION. 4.SEE DETAIL RCS FOR ROCK SOCKS USED AS ROUGH CUT STREET CONTROL. 5.SEE DETAIL CP FOR ROCK SOCKS USED AS CULVERT PROTECTION JOINT DETAIL VARIABLE LENGTH 10" OR 4" WIRE TIE ENDS 3/4" GRAVEL IN 1/4" WIRE MESH 12"12" ANY GAP AT JOINTS SHALL BE FILLED WITH AN ADEQUATE AMOUNT OF 3/4" GRAVEL WRAPPED WITH 1/4" WIRE MESH SECURED TO ENDS OF ROCK SOCK. ROCK SOCK N.T.S. RS EXISTING FIRE HYDRANT LOCATED AT THE MID POINT OF NORTH PROPERTY LINE, TOP NUT OF HYDRANT =1026.02 Designed By:Date: Job No.: FOR AND ON BEHALF OF HAGSTROM ENGINEERING PLLC Checked By:811 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL GOPHER STATE ONE CALL BENCHMARK:ByDateDescription of RevisionsNo.Sheet of D C B A 54321 219 6TH AVENUE EAST ALEXANDRIA, MN 56308 P.320.759.0764 WWW.HAGSTROMENG.COM HAGSTROM ENGINEERING CIVIL ENGINEERS | LAND CONSULTANTS CAUTION: IF THIS SHEET IS NOT 24"X36" IT IS A REDUCED PRINT C5.0C5.1 C5.1ORONO GARAGE CONDOSSITE PLANCONSTRUCTION DETAILS03/03/2025 24015 LEHMRH Designed By:Date: Job No.: FOR AND ON BEHALF OF HAGSTROM ENGINEERING PLLC Checked By:811 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL GOPHER STATE ONE CALL BENCHMARK:ByDateDescription of RevisionsNo.Sheet of D C B A 54321 219 6TH AVENUE EAST ALEXANDRIA, MN 56308 P.320.759.0764 WWW.HAGSTROMENG.COM HAGSTROM ENGINEERING CIVIL ENGINEERS | LAND CONSULTANTS CAUTION: IF THIS SHEET IS NOT 24"X36" IT IS A REDUCED PRINT C5.0C5.2 C5.2ORONO GARAGE CONDOSSITE PLANCONSTRUCTION DETAILS03/03/2025 24015 LEHMRH OLD CRYSTAL BAY ROADMNDOT RIGHT OF WAY PLAT NO 27-129 TEMPUS ORONO LLC PID: 3311823130020 METRO STORAGE ORONO LLC PID: 3311823130019 WJM PROPERTIES LLC PID: 3311823130015 ORONO PRESERVE RESIDENTIAL DEVELOPMENT ORONO INDUSTRIAL BOULEVARD EX. BOUNDARY EX. BOUNDARY 10211017102310231020 1020 PROPOSED BUILDING 1 PROPOSED BUILDING 2 PROPOSED BUILDING 3 PROPOSED BUILDING 4 PROPOSED BUILDING 5 102110.0' GRASS BUFFER PROPOSED TREES (TYP)PROPOSED CONIFERS (TYP) PROPOSED SHRUBS (TYP)PROPOSED PONDNATIVE GRASS (TYP) 10.0' GRASS BUFFER 10.0' GRASS BUFFER NATIVE GRASS (TYP) NATIVE GRASS (TYP) NATIVE GRASS (TYP) PROPOSED CONIFERS (TYP) ROCK (TYP) ROCK (TYP) 8.0' (TYP) 8.0' (TYP) 6.5' (TYP) 8.0' (TYP) 16.0' (TYP) 16.0' (TYP) STAGGER CONIFERS & TREES AS SHOWN (TYP) 16.0' (TYP) 16.0' (TYP) 16.0' (TYP) 16.0' (TYP) RETAINING WALL I HEREBY CERTIFY THAT THIS PLAN WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION, AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA. SIGNATURE: __________________________________________TYPED OR PRINTED NAME: MATTHEW R. HAGSTROM DATE: 03/03/2025 LICENSE NUMBER: 50731 Designed By:Date: Job No.: FOR AND ON BEHALF OF HAGSTROM ENGINEERING PLLC Checked By:811 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL GOPHER STATE ONE CALL BENCHMARK:ByDateDescription of RevisionsNo.Sheet of D C B A 54321 219 6TH AVENUE EAST ALEXANDRIA, MN 56308 P.320.759.0764 WWW.HAGSTROMENG.COM HAGSTROM ENGINEERING CIVIL ENGINEERS | LAND CONSULTANTS CAUTION: IF THIS SHEET IS NOT 24"X36" IT IS A REDUCED PRINT L1.1L1.0 L1.0ORONO GARAGE CONDOSSITE PLANPROPOSED LANDSCAPE PLAN03/03/2025 24015 LEHMRH0 SCALE: 1" = ORIGINAL GRAPHIC SCALE 15 30 60 30' NOTES: 1.CONTRACTOR SHALL FIELD VERIFY SIZE AND LOCATION OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION AND NOTIFY THE ENGINEER WITH ANY DISCREPANCIES. 2.CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL NECESSARY CONSTRUCTION STAKING. 3.INSTALL PERIMETER BMP'S PRIOR TO ANY CONSTRUCTION. 4.ALL TREES AND TREE ROOT ZONES OUTSIDE OF THE LIMITS OF CONSTRUCTION SHALL NOT BE DISTURBED. 5.SEE SHEET C5.0 - C5.2 FOR CONSTRUCTION DETAILS. LEGEND PROPOSED 1' AND 5' CONTOURS PROPOSED TREE PROPOSED SHRUB PROPOSED CONIFER 1431 1430 TREES TYPE CONT QTY Shade Trees 1.5" to 2.0"18 Ornamental 1.0"17 SHRUBS CONT QTY Small Coniferous Shrubs 18" - 24"27 Small Deciduous Shrubs 27 CONIFERS CONT QTY Coniferous Tree 4' - 6'85 GROUND COVERS CODE BOTANICAL / COMMON NAME CONT SPACING QTY NATIVE GRASSES / Filter Strip Mix Shooting Star Native Seed or approved equal Seed 35,550 S.F. ROCK 3/4" River Rock / 3/4" River Rock ---3,100 S.F. GRASS BUFFER Poa pratensis / Kentucky Bluegrass ---5,760 S.F. PLANT_SCHEDULE Large Deciduous Tree 2' - 4'18 18" - 24" TYPE TYPE SUM OF TREES QTY 192 EXISTING FIRE HYDRANT LOCATED AT THE MID POINT OF NORTH PROPERTY LINE, TOP NUT OF HYDRANT =1026.02 I HEREBY CERTIFY THAT THIS PLAN WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION, AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA. SIGNATURE: __________________________________________TYPED OR PRINTED NAME: MATTHEW R. HAGSTROM DATE: 03/03/2025 LICENSE NUMBER: 50731 Designed By:Date: Job No.: FOR AND ON BEHALF OF HAGSTROM ENGINEERING PLLC Checked By:811 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL GOPHER STATE ONE CALL BENCHMARK:ByDateDescription of RevisionsNo.Sheet of D C B A 54321 219 6TH AVENUE EAST ALEXANDRIA, MN 56308 P.320.759.0764 WWW.HAGSTROMENG.COM HAGSTROM ENGINEERING CIVIL ENGINEERS | LAND CONSULTANTS CAUTION: IF THIS SHEET IS NOT 24"X36" IT IS A REDUCED PRINT L1.1L1.1 L1.1ORONO GARAGE CONDOSSITE PLANLANDSCAPE DETAILS03/03/2025 24015 LEHMRHPLANTING NOTES: 1.THE LANDSCAPE CONTRACTOR SHALL LOCATE ALL EXISTING UTILITIES WITHIN THE LIMIT OF WORK AND IS RESPONSIBLE FOR ANY DAMAGE AS A RESULT OF THE LANDSCAPE CONSTRUCTION. 2.ALL TREE AND SHRUB LOCATIONS ARE TO BE STAKED ON SITE FOR APPROVAL BY THE CONSULTANT PRIOR TO INSTALLATION. 3.SUBSTITUTIONS: THE CONSULTANT SHALL APPROVE ANY SUBSTITUTION. 4.DO NOT PRUNE PLANTS UNLESS DIRECTED TO DO SO BY THE CONSULTANT. 5.CONTAINER STOCK IS PREFERRED FOR ALL PLANTS. IF CONTAINER STOCK IS NOT AVAILABLE FOR TREES, THEN ALL B&B PLANT MATERIAL SHALL HAVE ALL WIRE, TWINE, OR OTHER CONTAINMENT MATERIAL, EXCEPT FOR 100% HEMP BURLAP, REMOVED FROM THE TRUNK AND ROOT BALL OF THE PLANT PRIOR TO PLANTING. REMOVE THE TOP 2/3 OF THE HEMP BURLAP AFTER PLACING PLANT IN THE PIT. 6.PLANTING SOIL FOR ALL PLANTING AREAS: a.DO NOT STORE BULK MATERIALS NEAR STRUCTURES, OVER EXISTING PLANTING, OVER UTILITIES, WALKWAYS AND PAVEMENTS. a.PROVIDE EROSION CONTROL MEASURES TO PREVENT DISPLACEMENT OF BULK MATERIALS, DISCHARGE INTO WATERWAYS OR SEWERS, AND AIRBORNE DUST. b.PREPARING PLANTING AND SEEDING AREAS; SPREADING SOIL SHALL BE COMPLETED BY THE LANDSCAPE CONTRACTOR AND SUPERVISED BY THE GENERAL CONTRACTOR SO THAT GRADES ARE MET AS NOTED ON THE GRADING PLANS. c.PLANTING SOIL DEPTH SHALL BE A MINIMUM OF SIX (6) INCHES IN ALL LANDSCAPE BEDS. d.ALL PLANTING AREA SOIL SHALL BE 2-WAY (60% SAND, 40% COMPOST) TOPSOIL FROM AN APPROVED SOURCE. PROVIDE A 1-QUART SAMPLE FOR APPROVAL PRIOR TO IMPORTING ANY SOIL. TOPSOIL NOT MEETING INDUSTRY STANDARDS FOR COMPOSITION AND NUTRIENTS SHALL BE REJECTED. e.APPLY 2 INCHES OF APPROVED PLANTING SOIL OVER PREPARED SUBGRADE AND TILL INTO TOP 4 INCHES OF SUBSOIL. INSTALL REMAINING PLANTING SOIL TO A MINIMUM OF 4 INCHES SO THE TOTAL MINIMUM DEPTH OF NEW PLANTING SOIL IN NO LESS THAN 8 INCHES. ROLL AND RAKE SMOOTH. ENSURE NO ROCKS OR OTHER DEBRIS EXCEEDING 3 INCHES IN DIAMETER REMAIN. f.IF PREPARED SOIL OR PREPARED SUBGRADE IS RE-COMPACTED, RESTORE AS DIRECTED BY THE CONSULTANT. 9.INSTALL ROCKS IN ALL PLANTING BEDS TO A DEPTH OF 3 INCHES. 10.ROCKS SHALL NOT BE ABOVE OR MORE THAN 1/2 INCH BELOW ADJOINING SURFACE. MULCH SHALL BE HELD BACK 2-3 INCHES FROM THE STEMS AND TRUNKS OF PLANTS. 11.DURING PLANTING OPERATIONS, KEEP ADJACENT PAVING AREAS CLEAN AND PROTECTED FROM DAMAGE. WORK AREA SHALL BE KEPT CLEAN AND ORDERLY. 12.REMOVE NURSERY TAGS AND STAKES. 13.WARRANTY: INSTALLER AGREES TO WARRANTY PLANTING THAT FAILS IN MATERIALS, WORKMANSHIP OR GROWTH WITHIN A WARRANTY PERIOD OF 12 MONTHS FROM THE DATE OF PLANTING COMPLETION. 14.PLANT SYMBOLS SHALL DICTATE PLANT COUNT. 15.ALL LANDSCAPING SHALL BE PLANTED AND MAINTAINED IN A LIVING CONDITION BY THE CONTRACTOR UNTIL FINAL OWNER ACCEPTANCE. 16.IRRIGATION TO BE DESIGN BUILD BY IRRIGATION CONTRACTOR IF DESIRED BY OWNER. NOT PART OF THIS CONTRACT. 1" = 1'-0" TREE SINGLE STAKE PLANTING SHRUB AREAS. PLANTING AT STAKING DETAILPLANT PIT DETAIL TURF AREAS. PLANTING AT FX-PL-FX-TREE-022 TREE ON SLOPE - UNMODIFIED SOIL 1/2" = 1'-0" Native soil. Round-topped soil berm 4" high x 8" wide above root ball surface shall be centered on the downhill side of the root ball for 240°. Berm shall begin at root ball periphery. Finished grade. Bottom of root ball rests on existing or recompacted soil. SECTION VIEW Original slope should pass through the point where the trunk base meets substrate/soil. Prior to mulching, lightly tamp soil around the root ball in 6" lifts to brace tree. Do not over compact. When the planting hole has been backfilled, pour water around the root ball to settle the soil. Loosened soil. Dig and turn the soil to reduce the compaction to the area and depth shown. 4" layer of mulch. No more than 1" of mulch on top of root ball. Slope sides of loosened soil. 3x widest dimension of root ball SLOPE 5% (20:1) TO 50% (2:1) 3 EXISTING FIRE HYDRANT LOCATED AT THE MID POINT OF NORTH PROPERTY LINE, TOP NUT OF HYDRANT =1026.02 ORONO INDUSTRIAL BOULEVARD OLD CRYSTAL BAYROADBLOCK 1 LOT 1 MNDOT RIGHT OF WAY PLAT NO 27-129 TEMPUS ORONO LLC PID: 3311823130020 METRO STORAGE ORONO LLC PID: 3311823130019 WJM PROPERTIES LLC PID: 3311823130015 ORONO PRESERVE RESIDENTIAL DEVELOPMENT EX. BOUNDARY EX. BOUNDARY 10261025 1024 1022 102110201024102510241 0 2 3 1021 1024 10251026 102610261026 1026102610251025 1023 1020 PROPOSED BUILDING 1 PROPOSED BUILDING 2 PROPOSED BUILDING 3 PROPOSED BUILDING 4 PROPOSED BUILDING 5 102410.0' GRASS BUFFER PROPOSED TREES (TYP)PROPOSED CONIFERS (TYP) PROPOSED SHRUBS (TYP)PROPOSED PONDNATIVE GRASS (TYP) 10.0' GRASS BUFFER 10.0' GRASS BUFFER NATIVE GRASS (TYP) NATIVE GRASS (TYP) NATIVE GRASS (TYP) PROPOSED CONIFERS (TYP) ROCK (TYP) ROCK (TYP) 8.0' (TYP) 8.0' (TYP) 8.0' (TYP) 8.0' (TYP) 16.0' (TYP) 16.0' (TYP) STAGGER CONIFERS & TREES AS SHOWN (TYP) 16.0' (TYP) 16.0' (TYP) 16.0' (TYP) 16.0' (TYP) I HEREBY CERTIFY THAT THIS PLAN WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION, AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA. SIGNATURE: __________________________________________TYPED OR PRINTED NAME: MATTHEW R. HAGSTROM DATE: 09/18/2024 LICENSE NUMBER: 50731 Designed By:Date: Job No.: FOR AND ON BEHALF OF HAGSTROM ENGINEERING PLLC Checked By:811 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL GOPHER STATE ONE CALL BENCHMARK:ByDateDescription of RevisionsNo.Sheet of D C B A 54321 219 6TH AVENUE EAST ALEXANDRIA, MN 56308 P.320.759.0764 WWW.HAGSTROMENG.COM HAGSTROM ENGINEERING CIVIL ENGINEERS | LAND CONSULTANTS CAUTION: IF THIS SHEET IS NOT 24"X36" IT IS A REDUCED PRINT L1.1L1.0 NOT FOR CONSTRUCTIONL1.0ORONO GARAGE CONDOSSITE PLANPROPOSED LANDSCAPE PLAN09/18/2024 24015 LEHMRH0 SCALE: 1" = ORIGINAL GRAPHIC SCALE 15 30 60 30' NOTES: 1.CONTRACTOR SHALL FIELD VERIFY SIZE AND LOCATION OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION AND NOTIFY THE ENGINEER WITH ANY DISCREPANCIES. 2.CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL NECESSARY CONSTRUCTION STAKING. 3.INSTALL PERIMETER BMP'S PRIOR TO ANY CONSTRUCTION. 4.ALL TREES AND TREE ROOT ZONES OUTSIDE OF THE LIMITS OF CONSTRUCTION SHALL NOT BE DISTURBED. 5.SEE SHEET C5.0 FOR CONSTRUCTION DETAILS. LEGEND PROPOSED 1' AND 5' CONTOURS PROPOSED TREE PROPOSED SHRUB PROPOSED CONIFER 1431 1430 TREES TYPE CONT QTY Shade Trees 1.5" to 2.0"18 Ornamental 1.0"17 SHRUBS CONT QTY Small Coniferous Shrubs 18" - 24"27 Small Deciduous Shrubs 27 CONIFERS CONT QTY Coniferous Tree 4' - 6'85 GROUND COVERS CODE BOTANICAL / COMMON NAME CONT SPACING QTY NATIVE GRASSES / Filter Strip Mix Shooting Star Native Seed or approved equal Seed 35,550 S.F. ROCK 3/4" River Rock / 3/4" River Rock ---3,100 S.F. GRASS BUFFER Poa pratensis / Kentucky Bluegrass ---5,760 S.F. Large Deciduous Tree 2' - 4'18 18" - 24" TYPE TYPE SUM OF TREES QTY 192 P:\24015_Orono Car Condo's\CAD\CD's\24015_L1.0-Proposed Landscape Plan.dwg, 9/30/2024 10:35:28 AM, 1:1, LEH I HEREBY CERTIFY THAT THIS PLAN WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION, AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA. SIGNATURE: __________________________________________TYPED OR PRINTED NAME: MATTHEW R. HAGSTROM DATE: 09/18/2024 LICENSE NUMBER: 50731 Designed By:Date: Job No.: FOR AND ON BEHALF OF HAGSTROM ENGINEERING PLLC Checked By:811 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL GOPHER STATE ONE CALL BENCHMARK:ByDateDescription of RevisionsNo.Sheet of D C B A 54321 219 6TH AVENUE EAST ALEXANDRIA, MN 56308 P.320.759.0764 WWW.HAGSTROMENG.COM HAGSTROM ENGINEERING CIVIL ENGINEERS | LAND CONSULTANTS CAUTION: IF THIS SHEET IS NOT 24"X36" IT IS A REDUCED PRINT L1.1L1.1 NOT FOR CONSTRUCTIONL1.1ORONO GARAGE CONDOSSITE PLANLANDSCAPE DETAILS09/18/2024 24015 LEHMRHPLANTING NOTES: 1.THE LANDSCAPE CONTRACTOR SHALL LOCATE ALL EXISTING UTILITIES WITHIN THE LIMIT OF WORK AND IS RESPONSIBLE FOR ANY DAMAGE AS A RESULT OF THE LANDSCAPE CONSTRUCTION. 2.ALL TREE AND SHRUB LOCATIONS ARE TO BE STAKED ON SITE FOR APPROVAL BY THE CONSULTANT PRIOR TO INSTALLATION. 3.SUBSTITUTIONS: THE CONSULTANT SHALL APPROVE ANY SUBSTITUTION. 4.DO NOT PRUNE PLANTS UNLESS DIRECTED TO DO SO BY THE CONSULTANT. 5.CONTAINER STOCK IS PREFERRED FOR ALL PLANTS. IF CONTAINER STOCK IS NOT AVAILABLE FOR TREES, THEN ALL B&B PLANT MATERIAL SHALL HAVE ALL WIRE, TWINE, OR OTHER CONTAINMENT MATERIAL, EXCEPT FOR 100% HEMP BURLAP, REMOVED FROM THE TRUNK AND ROOT BALL OF THE PLANT PRIOR TO PLANTING. REMOVE THE TOP 2/3 OF THE HEMP BURLAP AFTER PLACING PLANT IN THE PIT. 6.PLANTING SOIL FOR ALL PLANTING AREAS: a.DO NOT STORE BULK MATERIALS NEAR STRUCTURES, OVER EXISTING PLANTING, OVER UTILITIES, WALKWAYS AND PAVEMENTS. a.PROVIDE EROSION CONTROL MEASURES TO PREVENT DISPLACEMENT OF BULK MATERIALS, DISCHARGE INTO WATERWAYS OR SEWERS, AND AIRBORNE DUST. b.PREPARING PLANTING AND SEEDING AREAS; SPREADING SOIL SHALL BE COMPLETED BY THE LANDSCAPE CONTRACTOR AND SUPERVISED BY THE GENERAL CONTRACTOR SO THAT GRADES ARE MET AS NOTED ON THE GRADING PLANS. c.PLANTING SOIL DEPTH SHALL BE A MINIMUM OF SIX (6) INCHES IN ALL LANDSCAPE BEDS. d.ALL PLANTING AREA SOIL SHALL BE 2-WAY (60% SAND, 40% COMPOST) TOPSOIL FROM AN APPROVED SOURCE. PROVIDE A 1-QUART SAMPLE FOR APPROVAL PRIOR TO IMPORTING ANY SOIL. TOPSOIL NOT MEETING INDUSTRY STANDARDS FOR COMPOSITION AND NUTRIENTS SHALL BE REJECTED. e.APPLY 2 INCHES OF APPROVED PLANTING SOIL OVER PREPARED SUBGRADE AND TILL INTO TOP 4 INCHES OF SUBSOIL. INSTALL REMAINING PLANTING SOIL TO A MINIMUM OF 4 INCHES SO THE TOTAL MINIMUM DEPTH OF NEW PLANTING SOIL IN NO LESS THAN 8 INCHES. ROLL AND RAKE SMOOTH. ENSURE NO ROCKS OR OTHER DEBRIS EXCEEDING 3 INCHES IN DIAMETER REMAIN. f.IF PREPARED SOIL OR PREPARED SUBGRADE IS RE-COMPACTED, RESTORE AS DIRECTED BY THE CONSULTANT. 9.INSTALL ROCKS IN ALL PLANTING BEDS TO A DEPTH OF 3 INCHES. 10.ROCKS SHALL NOT BE ABOVE OR MORE THAN 1/2 INCH BELOW ADJOINING SURFACE. MULCH SHALL BE HELD BACK 2-3 INCHES FROM THE STEMS AND TRUNKS OF PLANTS. 11.DURING PLANTING OPERATIONS, KEEP ADJACENT PAVING AREAS CLEAN AND PROTECTED FROM DAMAGE. WORK AREA SHALL BE KEPT CLEAN AND ORDERLY. 12.REMOVE NURSERY TAGS AND STAKES. 13.WARRANTY: INSTALLER AGREES TO WARRANTY PLANTING THAT FAILS IN MATERIALS, WORKMANSHIP OR GROWTH WITHIN A WARRANTY PERIOD OF 12 MONTHS FROM THE DATE OF PLANTING COMPLETION. 14.PLANT SYMBOLS SHALL DICTATE PLANT COUNT. 15.ALL LANDSCAPING SHALL BE PLANTED AND MAINTAINED IN A LIVING CONDITION BY THE CONTRACTOR UNTIL FINAL OWNER ACCEPTANCE. 16.IRRIGATION TO BE DESIGN BUILD BY IRRIGATION CONTRACTOR IF DESIRED BY OWNER. NOT PART OF THIS CONTRACT. 1" = 1'-0" TREE SINGLE STAKE PLANTING SHRUB AREAS. PLANTING AT STAKING DETAILPLANT PIT DETAIL TURF AREAS. PLANTING AT FX-PL-FX-TREE-022 TREE ON SLOPE - UNMODIFIED SOIL 1/2" = 1'-0" Native soil. Round-topped soil berm 4" high x 8" wide above root ball surface shall be centered on the downhill side of the root ball for 240°. Berm shall begin at root ball periphery. Finished grade. Bottom of root ball rests on existing or recompacted soil. SECTION VIEW Original slope should pass through the point where the trunk base meets substrate/soil. Prior to mulching, lightly tamp soil around the root ball in 6" lifts to brace tree. Do not over compact. When the planting hole has been backfilled, pour water around the root ball to settle the soil. Loosened soil. Dig and turn the soil to reduce the compaction to the area and depth shown. 4" layer of mulch. No more than 1" of mulch on top of root ball. Slope sides of loosened soil. 3x widest dimension of root ball SLOPE 5% (20:1) TO 50% (2:1) 3 P:\24015_Orono Car Condo's\CAD\CD's\24015_L1.0-Proposed Landscape Plan.dwg, 9/30/2024 10:35:15 AM, 1:1, LEH