Loading...
HomeMy WebLinkAbout1993-05-27 House Heating Test RecordSUMMARY REPORT -------------- Prepared For: Prepared By: NOT KNOWN AL HEBING NOT KNOWN ALPINE HTG & A/C MPLS MN 0 Job Name: DESIGN CONDITIONS for MPLS OUTDOOR SUMMER WINTER Dry Bulb 95 -20 Wet Bulb 75 Daily Range 21 Latitude 44 INDOOR SUMMER WINTER 75 70 62 Daily Swing 3.0 Elevation 822 Safety Factor (%) 5 Latent Factor (06) 27 05-27-93 60601903.15 NOTE: **1 Calculated Airflow is based upon load requirements. Verify that airflow calculated is compatible with selected equipment requirements. *"'IN Sensible Room Heating Heating Cooling Cooling Name BTUH CFM BTUH CFM ------- ---- BASEMENT ------- 21,031 ------- 294 ------- 5,570 281 FIRST FLOOR 29,296 410 20,720 1,046 SECOND FLOOR 42,304 592 25,047 1,265 ------- ------- 92,630 ------- 1,296 ------- 51,337 2,593 HEATING DELTA T 65.0 COOLING DELTA T 18.0 NOTE: **1 Calculated Airflow is based upon load requirements. Verify that airflow calculated is compatible with selected equipment requirements. *"'IN