Loading...
HomeMy WebLinkAbout1997-04-15 On Site Sewage Treatment Inspection ReportOwner: CITY of ORONO Munkipd Oftes Street Arlrau: Mal1ing AMnss: 2750 Kelley Parkway P.O. Boot 66 Orono, MN 55356 Crystal Bay, MN 55323-M _1 Address: 1000 Cox !Farm Rd. Permit 8's: 8394 Dates: 9/18/96 �� Contractors: Hayes Exc. (This is ( ] an existing system f Xl new construction). STEM COMPLIANCE (1-3): 1 Code System: Meets or exceeds current City standards in all respects rel -ting to design, construction, and location. Appears to be operating properly. 2 Compliant System: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous codes and is functioning properly. 3 Non -Compliant System: System may or ma;• no: meet current City standards for design, construction, or location, but is failing to properly treat and dispose of the current input; and any systeir, with less than three- feet of vertical separation between the bottom of the drainfield and the saturated soil level. (The saturated soil level I X has or ( ) has not been identified at this time. It the saturated soil level has not been identified, this classification is subject to revision.) K CONDITION (5-4): 5 Pumpout not needed at this time. 6 Solids accumulation in tanks indicates they should be pumped out this year. 7 System is dis=harging to the surface. Tanks must be pumped out within 48 hours. 8 Inspection risers missing -tanks could not he inspected. If tanks have not been pumped out within three fears, they should be pumped •:,ut and risers installed now. 9 Inspection pipe is located over tank baffi=-can not measure solids accumulation. If tanks have not been pumped out within three yearn, they should be pumped out now. (Daring the last septic tank Ifaintenanee Pumpout the tanks [ were or [ ] were not aonlirs�ed to be watertight by the licensed pumping contractor. If the tanks were not confirmed to be watertight, this classification is subject to revision.) D INFIELD CONDITION (11-14): it 1 Drainfield is dry, nz) surfacing evident. 2 Some evidence of surfacing, not critical yet. Repair is not required at this time. 13 Drainfield is saturated and %•igibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. 14 Drainfield extent and condition urkn3wn. POTENTIAL FOR SYSTEX FAILURE: (system agf: and c:a3ition, soils, etc.): low COMMENTS: Date of Inspection S /tic System Inspector Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation cf the system under current conditions. Td@Om (41M 47}7357 a FAX 473014