HomeMy WebLinkAboutRPS24-000130 Final Permit ReportFILE SUMMARY REPORT
February 24, 2025
FILE INFORMATION
File #:
24-001463
Address:
1710 Shadywood RD
Status:
Closed
Parcel #:
1711723210018
Open Date:
10/24/2024
Description:
Installation of supplemental beam and intellijack floor supports.
Close Date:
02/24/2025
Owner Name:
JOHN & JOAN FITZPATRICK
2001 SE SAILFISH POINT BLVD#103
Type:
Permitting
Owner Address:
STUART, FL 34996
CONTACTS
CONTACT
ASSOCIATION CONTACTTYPE ADDRESS PHONE
Kelly Saldivar
Applicant
Contractor
Company Address: Home: (612) 424-5165
6265 Carmen Ave. E
Inver Grove Heights MN 55076
Home Address:
6265 Carmen Ave. E
Inver Grove Heights MN 23454
PERMITS
PERMIT # TYPE
DATES
APPLICANT DESCRIPTION
RPS24- Residential Principal Structure Status: Closed
Kelly
Installation of supplemental beam and
000130 Building Permit
Application Date: 10
Saldivar
intellijack floor supports.
Interior Remodel / Basement
/24/2024
Finish
Issue Date: 10/28
/2024
Expiration Date: 08
/20/2025
Close Date: 02/24
/2025
INSPECTIONS
PERMIT # TYPE
INSPECTION DATE
INSPECTOR
STATUS
RPS24-000130 Footing
01/14/2025
Gary Nelson
Inspection Passed: Proceed
RPS24-000130 Building Final
01/16/2025
Gary Nelson
Not ready: Reinspect
RPS24-000130 Building Final
01/31/2025
Gary Nelson
No Show
RPS24-000130 Building Final
02/20/2025
Gary Nelson
Permit Finaled
REVIEWS
PERMIT #
TYPE
REVIEW DATE
REVIEWER
STATUS
RPS24-000130
Completeness Check
10/24/2024
Katie Fitzsimmons
Review Approved
RPS24-000130
Building Code Review
10/28/2024
Nicole Post
Review Approved
RPS24-000130
Septic Review
10/28/2024
Nicole Post
Review Approved
ACTIVITIES
PERMIT # TYPE ACTIVITY DATE ASSIGNED TO
STATUS
RPS24-000130 Online Permit Application 10/24/2024
Katie Fitzsimmons
Complete
RPS24-000130 Online Payment Received 10/24/2024
Joe Ruthenberg
Complete
RPS24-000130 Required Inspections 10/28/2024
Nicole Post
Review Approved
RPS24-000130 Online Payment Received 10/28/2024
Joe Ruthenberg
Complete
RPS24-000130 Review Complete 10/28/2024
Joe Ruthenberg
Review Approved
DOCUMENTS
SOURCE
DOCUMENT NAME
DATE
CREATED
BY
Construction documents (Footing/ foundation, floor, elevation, wall
Fitzpatrick Engineering Drawings. 10/24
System
bracing, etc.)
pdf
/2024
User
Construction documents (Footing/ foundation, floor, elevation, wall
Fitzpatrick Engineering
10/24
System
bracing, etc.)
Calculations. pdf
/2024
User
New Construction Minnesota State Energy Code Calculations CLICK
Fitzpatrick 1.docx
10/24
System
HERE
/2024
User
New Construction Ventilation, Make up and Combustion Air
Fitzpatrick 2.docx
10/24
System
Calculations Submittal Form CLICK HERE
/2024
User
Certified Site Plan: CLICK HEREbsp
Fitzpatrick 3.docx
10/24
System
/2024
User
Minnehaha Creek Watershed District (MCWD) Permit; OR
Fitzpatrick 4.docx
10/24
System
Documentation from MCWD stating no permit is required
/2024
User
Hardcover Calculations CLICK HERE
Fitzpatrick 5.docx
10/24
System
/2024
User
Hardscape Plan
Fitzpatrick 6.docx
10/24
System
/2024
User
Applicant Signature
signature.png
10/24
System
/2024
User
System Email
Your permit application has been 10/24
System
received.htm
/2024
User
System Email
Online Payment Received.htm
10/24
System
/2024
User
System Email
Your citizenserve payment has
10/24
System
been received.htm
/2024
User
Approved for Permit
1710 Shadywood Rd - Intellijack.
10/28
Nicole Post
pdf
/2024
System Email
Your citizenserve application
10/28
System
status has changed.htm
/2024
User
System Email
Online Payment Received.htm
10/28
System
/2024
User
System Email
Your citizenserve payment has
10/28
System
been received.htm
/2024
User
System Email
Your citizenserve application
10/28
System
status has changed.htm
/2024
User
Merge document
Permit Approved.htm
10/28
Joe
/2024 Ruthenberg
Merge document
Inspection Card.htm
10/28
Joe
/2024
Ruthenberg
Email
Inspection Report Individual.htm
01/14
Gary
/2025
Nelson
Additional Information
2025.01.20 Fitzpatrick Residence
01/28
Gary
Calculations Rev 1.pdf
/2025
Nelson
Additional Information
2025.01.20 Fitzpatrick Residence
01/28
Gary
Calculations Rev 1.pdf
/2025
Nelson
Email
Inspection Report Individual.htm
01/31
Gary
/2025
Nelson
Email
Inspection Report Individual.htm
02/20
Gary
/2025
Nelson
GENERAL REQUIREMENTS
Refer to subsequent plan and detail notes for variations and requirements specific to referenced project
NOTE PRIORITIES: Notes on the individual drawings govern over notes on this sheet.
SPECIFICATIONS: Refer to the specifications for information in addition to that contained in these notes
and the structural drawings.
STRUCTURAL DETAILS: The structural drawings are intended to show the general character and extent of
the project. They are not intended to show all details of the work. Details noted "typical" apply to
similar work throughout the project unless noted separately.
STRUCTURAL RESPONSIBILITIES: The structural engineer is responsible for the strength and stability of the
primary structure in its completed form.
CONTRACTOR RESPONSIBILITIES: The contractor is responsible for the means and methods of construction
and all job related safety standards (i.e. OSHA or Federally approved State plan). The contractor is
responsible for the strength and stability of the structure during construction. The contractor shall
provide temporary shoring, bracing and other elements required to maintain stability until the structure is
complete. It is the contractor's responsibility to be familiar with the work required in the construction
documents and the requirements for executing it properly. The contractor shall at his discretion employ
an Minnesota State registered structural engineer for design of temporary bracing and shoring. It is the
contractor's responsibility to contact the Engineer —of —Record to schedule applicable Structural
Observations.
DISCREPANCIES: In case of discrepancies between the specifications, reference standards and the
governing code, the Engineer will determine which shall govern. Discrepancies shall be brought to the
attention of the Engineer before proceeding with the work.
SITE VERIFICATION: The contractor shall verify all dimensions and conditions at the site. Conflicts between
the drawings and actual site conditions shall be brought to the attention of the Engineer before
proceeding with the work.
CONSTRUCTION LOADS: Loads on the structure during construction shall not exceed the design loads as
noted in DESIGN REQUIREMENTS below or the capacity of partially completed construction.
ALTERNATES: Alternates for specified items may be submitted to the Engineer for review
DESIGN CRITERIA
Building Code Conformance (meets or exceeds requirements)
2018 International Building Code (IBC)
2018 International Residential Code (IRC)
2020 Minnesota Building Code
2020 Minnesota Residential Code
DEAD LOADS:
Floor Dead Load 15 PSF
LIVE LOADS:
Floor Live Load (residential) 40 PSF
DEFLECTIONS: Total Load Deflection Limit L/240
Live Load Deflection Limit L/360
PROFESSIONAL ENGINEER
1
hereby certify that this plan, specification, or
report was by me or under my direct
�S J11111fO
�� E �i
!p•
prepared
supervision and that I am a duly Licensed
; y
7• •'/.!a
Professional Engineer dthe laws the
g� under aws o
LICENSED
:PROFESSIONAL'
State of Min peso a
— ENGINEER
Print Name: Jesse D
%N� seBxa Q�
GS
Signature:
y11F l't``""��
Date 10.18.4Q24 License #
Reviewed for Code Compliance
W
Nicole Post
V
RPS24-000130
Z
10-28-24
W (1j
0 Z
LU Z
Approved plans must be on site
CC Z
for the duration of the project.
Y d
Plans must be available to
Cc
inspector.
W
z
Z
Q
Please call 952-249-6000 to schedule
N
all inspections. Have permit number
1--
and address when calling.
LL
SOILS AND FOUNDATIONS
m
Cl)
LO
z
O
Z
O
cr
C
0
0
O
2
0
n
REFERENCE STANDARDS: Conform to IBC Chapter 18 "Soils & Foundations." GENERALNOTES
DESIGN SOIL VALUES:
REVISIONS
Allowable Foundation Pressure (Assumed) 1500 PST
TESTING & INSPECTION
Special Inspection & Testing per reviewing jurisdiction.
PROJECT NO:
ISA"'T
DESIGNED BY:
SI
DRAWN BY..
SI
CHECKED BY.
AD
DATE:
10.18.2024
SHEET NO:
S1.1
PROFESSIONAL ENGINEER
hereby certify that this plan, specification, or
report was by me or under my direct
�� E ��i�
`� �S J1111,f01
!p•
prepared
supervision and that am a duly Licensed
; y
7• •'-
Professional Engineer under the laws of the
g�
LICENSED
:PROFESSIONAL'
State of Minneso o
— ENGINEER E
Print Name: Jesse D
,�
Signature:
Date 10.18.V24 License #
IMG INTELLIJACK SYSTEM INFO
PART
DESCRIPTION
COMMENTS
MIN YIELD
STRESS, Fy
MIN TENSILE
STRESS, F„
ASTM A500, GRADE C 31/2"0x0.165x'L' MECHANICAL TUBING (L=36", 60", 84", & 120" —
IJ-350
FIELD CUT TO LENGTH). GALV TO ASTM A1057
46 KSI
62 KSI
ASTM A36 HRP&O R1/2x5xO'-6" W/ (4) 0.313"0 HOLES AT CORNERS & (1) 13/40x1/gx11/4" RETAINING
IJ—TP
RING CENTERED ON R W/ 1/4" EXTERNAL FILLET WELD ALL AROUND. CLEAR ZINC ELECTROPLATED TO
WOOD BEAM
CONDITION
36 KSI
58 KSI
ASTM B633 TYPE III
ASTM A36 HRP&O R1/2x31/2xO'-31/2" W/ (1) 0.563"0 HOLE CENTERED ON R &
36 KSI
58 KSI
IJ—BP
ASTM A513 3.13"0x0.188"x1" RING W/ 1/4" INTERNAL FILLET WELD ALL AROUND.
ENDUROCRETE
FOOTING CONDITION
72 KSI
87 KSI
14"0Z' FIBER PONE PRECAST CONC FTG (ENDURACRFTE) W/ 3/4"0 HOLE AT CENTER & 3/4' CHAMFER
ENDUROCRETE
IJ—IC
AT UPPER CIRCUMFERENCE (5,000 PSI MIN)
FOOTING CONDITION
IJ—SA
g x q
AVAILABLE)
FOOTING CONDITION
ASTM F1554—CR55 S1 11/4'0x10" THREADED ROD W/ HEAVY HEX NUT (TACK WELD)
IJ—LR
CLEAR ZINC ELECTROPLATED TO ASTM B633 TYPE III
55 KSI
75 KSI
IJ—TC
ASTM A108-13 (1018) 31/2"0x1" W/ 11/4"-7 THREADS & RECESSED SHOULDER TO FIT INSIDE THE
50 KSI
68 KSI
IJ350. CLEAR ZINC ELECTROPLATED TO ASTM B633 TYPE III
NOTE:
INSTALL PER MFR RECOMMENDATIONS
0
m
w �
U z
z
LU C� o
z z
LLJ z O
� z
Y E °
U Ir
w o
Ir 0 O
z
N =
ILL O
GENERAL NOTES
PROJECT NO:
IBA245a9
DESIGNED BV:
SI
DRAVJIJ BV:
SI
CHECKED BV:
JLO
DATE:
10.18.2824
SHEET NO:
S1.2
PROFESSIONAL ENGINEER `StlDtt� '
E FOUNDATION/(N) INTELLIJACK LAYOUT PLAN NOTES: '� 4
O hereby certify that this plan, specification, or `ps E �G�
report was prepared by me or under my direct ; !p,•''��'•,y�
1. REFERENCE 51.1 & 51.2 FOR GENERAL REQUIREMENTS supervision and that I am a duly Licensed 7, •'/.!�
Professional En under the laws of the LICENSED
Engineer 2. CONTRACTOR TO NOTIFY ENGINEER OF RECORD OF DISCREPANCIES 9� _ :PROFESSIONAL.
BETWEEN FIELD CONDITIONS &THOSE SHOWN IN THESE DOCUMENTS State of Minneso a o ENGINEER e
PRIOR TO WORK TYR %N� seB�a QS
Print Name: Jesse D
3. IENGCNEER OFATES ) RECORD IFCMU WFIELD CONEDITALL ON OONSC DIFFERFOOTING
N(THOEIFY AREA Signature: IM �tT`
OF WORK)
Date 10.18. 24 License # 58974
4. SECTION CUT — DETAIL NUMBER/SHEEP NUMBER p /�
5. Q INDICATES LOCATION OF INTELLIJACK SYSTEM ((20) TOTAL)
W uD
cD
• DESIGN LOAD = 2310 LBS 15'-0" _ _ 10'-8" _ _ 10'-4" _ 3'-4' _ 10'-8" _ _ 11'-0" _ UZ
6, INTELLIJACK SPACING SHALL BE AS INDICATED ON PLAN r Z
7, CONTRACTOR IS RESPONSIBLE FOR ALL TEMPORARY SHORING O
S. REPLACE "IN —KIND" ALL (E) WOOD MEMBERS (JOISTS, PURLINS, 1 _ _ _ _ _�_ _�_ _ r----------------- z ZO
SUBPURLINS, SHEATHING, STUDS, WALL PLATES) WHICH SHOW SIGNS OF , r — — — — — -1 Z C
DRY ROT OR STRUCTURAL DAMAGE rr r 1 � Z O
9. ALL CONSTRUCTION MATERIALS IN THESE DOCUMENTS ARE (N) UNO L�J L� p
(E) CONO SLAB 2'-Da
ON GRADE (E) CRAWL (� p
F, r�¢I SPACE 0 0
rD,I z
2 F----T— —� r----- r— -- — o �I 1 1 O_
-0" 1- 1 ' 2 S4.1 TYPI I N x
(E) CRAWL 1
_ r I SPACE J 1L J L J 2' 0" I ILL r
11 S4.1 TYP J 1 4'-0" 5'— " 4'-0 l �Ld
1
r� 1 rr� r I r — — — — —- 1
LOJ RE
54.1 n
-
- � _ �> REVISIONS
w �OJ
I II
3 Q E) CRAWL 1 (E) CRAWL (E) CRAWL
SPACE SPACE SPACE
I IIIL
II r,
w g
a
5 L-- L -� L-------J I L------ L-----J LLOJ PiBAzasos o:
_ — -
-
L--- -----------------------------------� DESIGNED BV:
SI
2'—D"SQx6"DP 3/a" MINUSIFTG (E) CONC SLAB DRAwN eY:
ON GRADE CHECKED BV:
_ JLD
DATE:
FNQIIEAGRFTF
FTG PER GENERAL NOTES TYP +o.lazoza
(E) FDN / (N) INTELLIJACK LAYOUT PLAN SHEETNO:
SCALE: I/g"=1'-0" Z SL.1
Exposed earth in unvented crawl space foundations
shall be covered with Class I vapor retarder. Vapor
retarder shall lap 6" and be sealed or taped.
(E) FLOOR SHEATHING
(E) FLOOR FRAMING
(E) BEAM
(4'/2'W MIN)
IJ—LR PER GENERAL NOTES
(3" MAX UNBRACED
THREADED ROD LENGTH)—
—IMG IJ—TC PER
GENERAL NOTES
IMG IJ-350 PER
GENERAL NOTES (CUT
2500 PSI CONC INFILL TO REQ'D LENGTH)
(UNDERP
REMOVE AIR POCKETS)
(E) GONG SLAB ON
GRADE (SAWCUT AS 4„ IMG IJ—BP W/ IJ—SA PER
REQ'D) MIN
GENERAL NOTES
TYP
PROFESSIONAL ENGINEER
1
hereby certify that this plan, specification, or
report was by me or under my direct
`� �S J11111fO
�N E ��i�
!p•
prepared
supervision and that I am a duly Licensed
; y
7• •'/.!a
Engineer under e laws of
Professional En gdthe lf the
LICENSED
:PROFESSIONAL.
State of Minneso a
— ENGINEER E
Print Name: Jesse D
5BB�a Qz
Signature:
Date 10.18.V24 License #
IJ—LR PER GENERAL
NOTES (3" MAX
UNBRACED THREADED
ROD LENGTH)—
IJ—TC PER
'_RAL NOTES
(E) FLOOR SHEATHING
E) BEAM
(4t/,"W MIN)
WOOD SCREWS
IMG IJ-350 PER
GENERAL NOTES (CUT
TO REQ'D LENGTH)
IMG IJ—IC R IMG IJ—BP W/ IJ—SA
GENERAL NO S PER GENERAL NOTES
(E) INTERIEOR
GRAD
W
U
z
W
0 z_
W z
[r z
Y FL
U Ir
— w
� p
Q z
N
LL
INTEWJACK
DETAILS
r
V�y_�
IMG IJ—IC PER
COMPACTED CRUSHED
a =
_
�III 11 I I hI—
STONE BASE PER PLAN
PROJECTNO:
PER
PLAN
IBAza.sos
_
COMPACTED CRUSHED
DESIGNED BV:
sl
PER
STONE BASE PER PLAN
DRAwN er:
PLAN
NOTES:
NOTES:
sl
c� pKED ar:
1. REF PLAN FOR LAYOUT & INSTALLATION REG'S
1. REF PLAN FOR LAYOUT & INSTALLATION REG'S
DAo s.zoza
2. INSTALL PER MFR RECOMMENDATIONS
2. INSTALL PER MFR RECOMMENDATIONS
INTELLIJACK AT (E SLAB ON GRADE
IMG INTELLIJACK IN
CRAWLSPACE
r
SHEE N0:
1 S4.1
SCALE: 1"=1'-0" �
SCALE: 1"=1-0" �
From: gnelson@oronomn.gov
Sent: 02/20/2025 - 11:35 AM
To: ibaminneapolispermits@teaminnovative.com
CC: jmejia@oronomn.gov,gnelson@oronomn.gov,kfitzsimmons@oronomn.gov
Subject: Inspection Report Individual
CITY OF ORONO
ti 2750 KELLEY PARKWAY, ORONO, MINNESOTA 55356
(I�FSH00� www.cronomn.gov
Inspection Report
1710 Shadywood RD
Permit Number: RPS24-000130
Site Address: 1710 Shadywood RD, Orono, MN 55391
Property Owner: JOHN & JOAN FITZPATRICK
Description: Installation of supplemental beam and intellijack floor supports.
Inspection Date: 02/20/2025
Inspection Type: Building Final
Inspection Results: Permit Finaled
Sincerely,
ti
Gary Nelson
952-242-4442
To schedule your inspections please call: (952) 249-4600
CITY OF ORONO
2750 KELLEY PARKWAY
ORONO, MN 55356
PH: (952) 249-4600
FAX: (952) 249-4616
CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY!