HomeMy WebLinkAbout1986-11-24 On Site Sewage Treatment Inspection ReportOn the Vortb Shorty of
lake Ullnn Tonka
ON SITE SEWAGE TREATMENT CITY
INSPECTION REPORT OF POST OFFICE BOX 66
_ 1335 S. Brown Rd.
Crystal Bay, MN 55323
473-7357
OWNER i�2� �: p�— ��'tS\L.. ADDRESS
PERMIT NO.'S. --Q �r�� DATES— r—�----I'D—`—�'--- CONTRACTORS -`-
City Ordinance No. 210 requires that each onsite sewage treatment system in Orono he inspected on a regular basis. The on<ite sewage
treatment system at the above address has been inspected and appears to fall into the category checked below.
(This is U an existing system 0 new construction)
01 Meets or exceeds current City standards in all respects relating to design. construction, and location. Appears to be operating
properly.
F1 2 Does not meet all current City standards for new construction 11978 Code) but in most respects appears to be designed,
located, and constructed generally ut accordance with previous cozies. System appears to be functioning properly: no major
upgrading of the system is required at this time.
❑ 3 Does not meet carrent City standards in many respect% relating to design, construction, or location. Appears to be- operating
adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at
this time.
4 System may ar may not meet current CRs standards for design, construction or location, but is Jailing to properly treat and
dispose of the current input, and is endangering a water supply, or is a source of pollution to surface er gr,bundwaters, or is
creating a safety hazard. ur is otherwise zteaung a public nuisance. Please contact the City Inspector to discuss system repair/
replacement procedures, if drainfield replacement is necessary, soil testing will usually be re(Is ued. and a design and site plan
must be submitted for review. Your contractor must obtain a permit before work is started.
SYSTEM CONDIT ION 10 Checked items may require your action)
Tank inspection indicates
jf] Pum -.,,,tit not needed at this time.
❑ Solids accumulation in tanks indicates they should be pump-
ed out this year to help prevent future problems.
Cl Solids accumulation in tanks is at a critical level, Tanks
should be pumped out as soon as possible.
❑ System is discharging to surface. Tanks must tie pumped
within 48 hours to elim nay,- .irface discharge.
❑ Inspection risers missing- :irks could not be inspected.
Inspection risers (4'• dia paw must be mstailed in each tank
at next purnpout. If tanks h --.e not been oumped out within
the last three years, they should to pumped out now.
17 Inspection pipe is located directly over tank baffle. (floes not
give accurate measurement of solids accumulation ) If tanks
have not (seen pumped out within the last three years, they
should be pumped out now.
Drainfield inspection indicates
U Drautfield is dry, no surfacing evident.
Ll Some evidence of surfacing, not critical yet.
F] Oranbfield is saturated and visibly discharging untreated
effluent to the surface. This condition may require replace-
ment or additions to drainfield. Contact the C-ty Inspector
immediately. Repairs mast be completed within 90 days.
(_) Dwinheld extent and condition unknown.
SITE CHARACTERISTICS
Limiting Site Factors
Potential for System Failure
Site Capabilities lot
❑ Slope
Idepends on soil types, water
Future Expansion
❑ Soil
table, and system condition)
19 Adequate
CJ High water table
C -)J Low
❑ Fair
❑ Lot site
❑ Medium
❑ Poor
❑ Lake, wettand, or stream
❑ H:qh
❑ Inadequate
❑ Drainage
U System is causing visible
surface discharge.
CON.--
-------- --- -- -- n -
Date of Inspection Septic System Inspector
Note In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that
this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of tie adequacy
of the system under current conditions based on the available intormatrun.
This report must be kept on the premises with system location and pumping records
WHITE COPY ' Inspector's File (TOLD COPY / Homeowner