HomeMy WebLinkAboutSES25-000001 Final Permit ReportFILE SUMMARY REPORT February 19, 2025 FILE INFORMATION File #:25-000112 Address:4725 Bayside RD Status: Closed Parcel #:0611723220022 Open Date:01/31/2025 Description:PV solar Close Date:02/19/2025 Owner Name:SUZANNE & MARK STAUDUHAR Type:Permitting Owner Address:4725 BAYSIDE RD MAPLE PLAIN, MN 55359 CONTACTS CONTACT ASSOCIATION CONTACTTYPE ADDRESS PHONE WOLF RIVER ELECTRIC NATHAN TOLLEFSON Applicant Contractor Company Address: 101 Isanti Parkway Northeast Suite G isanti MN 55040 Home Address: 101 Isanti Parkway Northeast Suite G isanti MN 55040 Suzanne Stauduhar Current Property Owner Home Address: 4725 Bayside Rd, Orono MN 55359 PERMITS PERMIT #TYPE DATES APPLICANT DESCRIPTION SES25-000001 Solar Energy Systems Permit Solar Energy Systems Permit Status: Closed Application Date: 01/31/2025 Issue Date: 02/05/2025 Expiration Date: 08/19/2025 Close Date: 02/19/2025 WOLF RIVER ELECTRIC PV solar INSPECTIONS PERMIT #TYPE INSPECTION DATE INSPECTOR STATUS SES25-000001 Building Final 02/19/2025 Gary Nelson Permit Finaled REVIEWS PERMIT #TYPE REVIEW DATE REVIEWER STATUS SES25-000001 Completeness Check 02/04/2025 Katie Fitzsimmons Review Approved SES25-000001 Building Code Review 02/04/2025 Nicole Post Review Approved SES25-000001 Zoning Review 02/05/2025 Matthew Karney Review Approved SES25-000001 Final Review 02/05/2025 Matthew Karney Review Approved ACTIVITIES PERMIT #TYPE ACTIVITY DATE ASSIGNED TO STATUS SES25-000001 Online Payment Received 01/31/2025 Tano Mejia Complete SES25-000001 Required Inspections 02/04/2025 Nicole Post Review Approved SES25-000001 Online Payment Received 02/05/2025 Tano Mejia Complete SES25-000001 Review Complete 02/05/2025 Tano Mejia Review Approved DOCUMENTS SOURCE DOCUMENT NAME DATE CREATED BY Documentation Suzanne Stauduhar_Rev_Full Set SS.pdf 01/31/2025 System User Documentation Suzanne Stauduhar Letter SS.pdf 01/31/2025 System User Construction Drawings Suzanne Stauduhar_Rev_Full Set SS.pdf 01/31/2025 System User Elevation Drawing Suzanne Stauduhar_Rev_Full Set SS.pdf 01/31/2025 System User Site Plan Suzanne Stauduhar_Rev_Full Set SS.pdf 01/31/2025 System User System Email Notification Your permit application has been received.htm 01/31/2025 System User System Email Online Payment Received.htm 01/31/2025 System User System Email Your citizenserve payment has been received.htm 01/31/2025 System User Approved for Permit 4725 Bayside Rd - Solar.pdf 02/04/2025 Nicole Post Approved for Permit Suzanne Stauduhar_Rev_Full Set SS with markups.pdf 02/05/2025 Matthew Karney System Email Your citizenserve application status has changed.htm 02/05/2025 System User System Email Online Payment Received.htm 02/05/2025 System User System Email Your citizenserve payment has been received.htm 02/05/2025 System User System Email Your citizenserve application status has changed.htm 02/05/2025 System User Merge document Permit Approved.htm 02/05/2025 Tano Mejia Merge document Inspection Card.htm 02/05/2025 Tano Mejia Email Inspection Report Individual.htm 02/19/2025 Gary Nelson 1 Jason (Tano) Mejia From:gnelson@oronomn.gov Sent:Wednesday, February 19, 2025 1:45 PM To:nathan@wolfriverelectric.com Cc:Gary Nelson; Katie Fitzsimmons; Jason (Tano) Mejia Subject:Inspection Report Individual CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952) 249-4616 Inspection Report 4725 Bayside RD Permit Number: SES25-000001 Site Address: 4725 Bayside RD, Orono, MN 55359 Property Owner: SUZANNE & MARK STAUDUHAR Description: PV solar Inspection Date: 02/19/2025 Inspection Type: Building Final Inspection Results: Permit Finaled Sincerely, Gary Nelson 952-242-4442 To schedule your inspections please call: (952) 249-4600 2 CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY! /-oning Hpprovai SES25-000001 Matthew Karney 02/05/2025 SUZANNE STAUDUHAR 4725 Bayside Rd, Orono, MN 55359 7 PHOTOVOLTAIC SYSTEM SPECIFICATIONS SYSTEM SIZE: 18 Modules -Roof Mounted 7.470 kW DC 6.912 kW AC MODULE TYPE &AMOUNT: 18 SUNPOWER SPR-M415-H-AC (415W) � MODULE DIMENSIONS: (L/W/H) 73.7/40.6"/1.57" INVERTER: 18 ENPHASE IQ7HS-66-M-US (SPWR-A5) [1 PHASE, 240V] • INTERCONNECTION METHOD: SUPPLY SIDE TAP GENERAL STRUCTURAL NOTES: GOVERNING CODES SHEET INDEX a. THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING ALL WORK SHALL CONFORM TO THE PV-0.0 COVER SHEET THE SPECIFIED RAIL SYSTEM. THE MOUNTING FEET ARE TO FOLLOWING CODES PV-1.0 PLOT & SITE PLAN BE SPACED AS SHOWN IN THE DETAILS, AND MUST BE STAGGERED TO a. 2023 NATIONAL ELECTRICAL CODE PV_ 1.1 STRING ATTACHMENT ADJACENT FRAMING MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD. b. 2020 MINNESOTA RESIDENTIAL CODE b. UNLESS NOTED OTHERWISE, MOUNTING ANCHORS SHALL BE 516" LAG c. 2020 MINNESOTA BUILDING CODE Pi1.2 EQUIPMENT ELEVATION SCREWS WITH A MINIMUM OF 2 12" PENETRATION INTO ROOF FRAMING. d. 2024 MINNESOTA ENERGY CODE D-2.0 ATTAHCMENT DETAIL c. THE PROPOSED PV SYSTEM ADDS 3.0 psf TO THE ROOF FRAMING SYSTEM. e. 2020 MINNESOTA ACCESSIBILITY CODE D-2.1 3-LINE SHEET 1. ROOF LIVE LOAD = 35 psf TYPICAL, 0 psf UNDER NEW PV SYSTEM. f. 2020 MINNESOTA MECHANICAL 2. GROUND SNOW LOAD = 50 psf & FUEL GAS CODE D-2.2 PLACARD SHEET 3. WIND SPEED = 115 mph g. 2020 MINNESOTA PLUMBING CODE D-2.3 WARNING SHEET 4. EXPOSURE CATEGORY = C h. 2020 MINNESOTA STATE FIRE CODE i ANY OTHER LOCAL AMENDMENTS AUTHORITIES HAVING JURISDICTION BUILDING: HENNEPIN COUNTY ZONING: HENNEPIN COUNTY UTILITY: WRIGHT HENNEPIN UTILITY METER #342674200 Satellite View I A' I Vicinity Map U y __r I `i Is %A i GENERAL ELECTRIC NOTES 1. ALL COMPONENTS ARE UL LISTED AND CEC CERTIFIED, WHERE WARRANTED. 2. THE SOLAR PV SYSTEM WILL BE INSTALLED IN ACCORDANCE WITH ARTICLE 690 OF THE NEC 2023 3. THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEM INSPECTED PRIOR TO PARALLEL OPERATION. --4. ALL CONDUCTORS OF A CIRCUIT, INCLUDING THE EGC, MUST BE INSTALLED IN THE SAME ` RACEWAY, OR CABLE, OR OTHERWISE RUN WITH THE PV ARRAY CIRCUIT CONDUCTORS WHEN THEY LEAVE THE VICINITY OF THE PV ARRAY. = 5. WHERE METALLIC CONDUIT CONTAINING DC CONDUCTORS IS USED INSIDE THE BUILDING, IT SHALL BE IDENTIFIED AS "CAUTION: SOLAR CIRCUIT" EVERY 10FT. 6. HEIGHT OF THE AC DISCONNECT SHALL NOT EXCEED 6-7" PER NEC CODE 240.24. 7. A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH CEC 690.47 AND 250.50 THROUGH 60 AND 250-166 SHALL BE PROVIDED. PER NEC GROUNDING ELECTRODE SYSTEM OF EXISTING �~ BUILDING MAY BE USED AND BONDED TO THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE OR INADEQUATE A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT. GROUND ROD WITH ACORN CLAMP. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN #8 AWG AND NO LARGER THAN #6 AWG COPPER AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM. 8. PHOTOVOLTAIC MODULES ARE TO BE CONSIDERED NON-COMBUSTIBLE. 9. PHOTOVOLTAIC INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING. MECHANICAL, OR BUILDING ROOF VENTS. 10. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH USE. WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF THE ROOF SURFACE. 11. ALL STNAGE TO BE PLACED IN ACCORDANCE WITH THE LOCAL BUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT. ALL PLAQUES AND SINAGE WILL BE INSTALLED AS REQUIRED BY THE NEC AND AHJ. 12. AS SPECIFIED BY THE AHJ, EQUIPMENT USED IN UNGROUNDED SYSTEMS LABELED ACCORDING TO NEC 690.35(F). 13. INVERTER(S) USED IN UNGROUNDED SYSTEM SHALL BE LISTED FOR THIS USE [NEC 690.35(G)]. 14. THE INSTALLATION OF EQUIPMENT AND ALL ASSOCIATED WIRING AND INTERCONNECTION SHALL BE PERFORMED ONLY BY QUALIFIED PERSONS [NEC 690.4(C)] 15. ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED (OR BETTER), INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND SWITCHES. 16. ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH NEC ARTICLE 250. 17. SYSTEM GROUNDING SHALL BE IN ACCORDANCE WITH NEC 690,41. 18. PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION IN ACCORDANCE WITH NEC 690.12 19. DISCONNECTING MEANS SHALL BE LOCATED IN A VISIBLE, READILY ACCESSIBLE LOCATION WITHIN THE PV SYSTEM EQUIPMENT OR A MAXIMUM OF 10 FEET AWAY FROM THE SYSTEM [NEC 690.13(A)] 20. ALL WIRING METHODS SHALL BE IN ACCORDANCE WITH NEC 690.31 r 21. WORK CLEARANCES AROUND ELECTRICAL EQUIPMENT WILL BE MAINTAINED PER NEC 110.26(A)(1), 110.26(A)(2) AND 110.26(A)(3). 22. ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED & IDENTIFIED IN ACCORDANCE WITH UL1703 23. ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND ANCHOR CONDUIT RUNS AS REQUIRED PER NEC. { n 1 X y ECTOR n a l n E E R a 657 W. GALENA PARK BLVD. STE. 707 PHONE lH177I 990-117-9 k 'PAPER, LXTA E1402Q wWW. VECTORSE.CQM vl LlcENSED ROFESSIONAL BEN 25: 01 /31 /2025 VSE Project Number: U3594.0103.251 I hereby certify that this plan, specification or report Vector structura€ engineering has reviewed the existing was prepared by me or under my direct supervision structure With loading from the solar array and screw and that I am a duly Licensed Professional Engineer connections to the existing framing. The design of the racking system, racking connections, and all other under the laws of the State of Minnesota, structural is by others. Mechanical. architectural, and all Kelly G. Springer, License NO. st}925, other nonstructural aspects of the design are by others. Electrical is by others, unless stamped by Dean Levorsen. Expiration Date: 30-June-2026 WOLF RIVER _JWELECTRIC WOLF RIVER ELECTRIC 101 ISANTI PARKWAY NE, SUITE G ISANTI, MN 55040 ELECTRICAL LICENSE: EA777669 Building License BC773271 Contact: (763) 229-6662 contact@wolf rive relectric. com DESIGNED BY: WOLF RIVER ELECTRIC Awo to 7 6J je- Designer Signature r I: = z o w � �LLii �z� cM O wLn N Q U = -0 •- Ln U#) CL z � w w o w z N w o Q 0= N Z) V) Revisions Table Description I Date I Rev. Sheet Name & Creation Date COVER SHEET 01/24/2025 Sheet Number PV-0.0 1 1 1 1 ROOF ACCESS POINT RAVCTn1= Qn❑ n 200'-011 I\ 83'-011 I coca Coto DRIVEWAY (PAVEMENT) CONCRETE U KI V CVVA Y - - I (PAVEMENT) ROOF OBSTRUCTION SYSTEM LEGEND OEXISTING UTILITY METER #342674200 j� EXISTING MAIN SERVICE PANEL PM NEW UTILITY EXPORT METER TB NEW TAP BOX AC NEW UTILITY AC DISCONNECT WOLF RIVER ELECTRIC WOLF RIVER ELECTRIC 101 ISANTI PARKWAY NE, SUITE G ISANTI, MN 55040 ELECTRICAL LICENSE: EA777669 Building License BC773271 Contact: (763) 229-6662 contact@wolfriverelectric.com DESIGNED BY: NEW ENPHASE COMBINER WOLF RIVER I ELECTRIC PANELS & INVERTERS y ■ 18 SUNPOWER SPR-M415-H-AC (415W) (L/W/H) 73.7"/40.6"/1.57" 18 ENPHASE IQ7HS-66-M-US (SPWR-A5) [1 PHASE, 240VI I I I 40'-0'r Designer Signature + ® = FIRE PATHWAY I � Ij ! = ROOF OBSTRUCTIONS 9� ROOF ACCESS �� = ATTIC RUN CONDUIT W POINT r � g I ATTIC RUN CONDUIT JUNCTION BOX v 75'-011 NOTE � 1, THIS DRAWING IS FOR ILLUSTRATIVE PURPOSES ONLY! 1`�(f� 2. ALL TESTING SHALL BE PERFORMED BY QUALIFIED NEW UTILITY EXPORT PERSONNEL, WITH PROPER PERSONAL PROTECTIVE S METER EQUIPMENT. Q 3. 24/ 7 UNESCORTED KEYLESS ACCESS IS TO BE Z CD PROVIDED FOR ALL UTILITY EQUIPMENT. '—' CD 4. AC DISCONNECT SHOULD BE LOCATED TOGETHER IN A 0 d1 Z Z NEW ENPHASE READILY ACCESSIBLE LOCATION WITHIN 10' OF THE MAIN ce M 0 z N \ LU COMBINER ( SERVICE METER Ln Z = M 1 NEW UTILITY AC (f) z ( w i DISCONNECT • ROOF ACCESS POINT oo - z w ROOF ACCESS POINTS SHALL BE LOCATED IN AREAS THAT DO NOT w L.f) O LU REQUIRE N CO = / NEW TAP BOX THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS � L rn WINDOWS O = J J OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING Q j EXISTING UTILITY CONSTRUCTION N D D METER #200016038 IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT D WITH (AI OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES AND OR - EXISTING MAIN SERVICE <_ 411'-0" SIGNS PANEL 670 Revisions Table ROOF SECTIONS Description Date Rev. ROOF #01 MODULE - 14 SLOPE - 10.00/12 AZIMUTH - 181.100 MATERIAL - ASPHALT SHINGLE TRUSS SIZE & SPACING - 2"X4" @ 24" O.C. PROPERTY LINE 1, 382 -011ROOF #02 MODULE - 4 SLOPE - 10.00/12 AZIMUTH - 245.150 MATERIAL - ASPHALT SHINGLE 11T TRUSS SIZE & SPACING - 2"X4" @ 24" O.C. 1 SITE PLAN & PLOT PLAN PV 1.O SCALE: NTS (NOT TO SCALE) •' 1 SYSTEM LEGEND LOT:2.55 ACRES PARCEL: 0611723220022 PROPERTY LINE FENCE LINE DRIVEWAY Sheet Name & Creation Date PLOT &SITE PLAN 01/24/2025 Sheet Number PV-1.0 SYSTEM LEGEND CIRCUIT #01 • = ATTACHMENT POINTS(43 Nos) # MODULE - 9 = TRUSS CIRCUIT #02 # MODULE - 9 = RAIL SYSTEM CIRCUIT(S) ARRAY AREA MODULE AREA MODULE DIM (75.74 X 40.87) 21.5 SQ. FT. AREA OF ARRAY 367.22 SQ. FT. ROOF AREA 3482.70 SQ. FT. ROOF COVERAGE % ROOF AREA/ARRAY AREA 10.54% 1 \ATTACHMENT AND STRING LAYOUT PV 1.1 / SCALE: NTS (NOT TO SCALE) NOTE: THE MAXIMUM CANTILEVER OF THE RAIL SHALL BE 1/3 OF THE ATTACHMENT SPACING. 0 i i I I I I I I I I I I I I I IF I I I I I I I I I I I I I I I I I I I I I I I I I I I I I ! I I ! + I I wIH ' I I I I I I I I I I I 11 AC 1 C �YECTOR 551 W. GALENA PARK SLVC. STE. 101 PH,ONJ 180 1) 990- 1 775 b PAPER, L1TAH 04920 WWW.VECTORSE.CDM a ` LICENSED 1' ROFESSIONAL I dO 25 01 /31 /2025 VSE Project Number: U3594.0103.251 I hereby certify that this plan, specification or report Vector structural engineering has reviewed the existing was prepared by me or under my direct supervision structure With loading from the solar array and screw and that I am a duly Licensed Professional Engineer connections to the existing framing. The design of the racking system, racking connections, and all other under the laws of the State of Minnesota, structural is by others. Mechanical, architectural, and all Kelly G. Springer, License No. 6D925, other nonstructural aspects of the design are by others. Electrical is by others, unless stamped by Dean Levorsen. Expiration Date: 30-.tune-2026 B.O.M. BILL OF MATERIALS CATEGORY QTY. SURGE PROTECTORS 1 SPR-M415-H-AC 18 IQ7HS MICROINVERTER 18 INVISIMOUNT 16 SPLICES 6 MIDS 26 ENDS 20 J - Box 2 GROUNDING RODS 1 TRUNK CABLES 20 FEET 48 TERM CAPS 4 SEALING CAPS 4 CABLE SPLICES 4 IT350 3 ENPHASE COMBINER 1 60A AC DISCONNECT N EMA3 1 P, 3W 120/240V 1 EATON BR 20A 2-POLE BREAKER 3 40A FUSE 250V 2 200A (METER SOCKET) (MN) (U4801XL5T9) 1 CONSUMPTION 1 WOLF I RVER .AIPELECTRIC WOLF RIVER ELECTRIC 101 ISANTI PARKWAY NE, SUITE G ISANTI, MN 55040 ELECTRICAL LICENSE: EA777669 Building License BC773271 Contact: (763) 229-6662 contact@wolfriverelectric.com DESIGNED BY: WOLF RIVER ELECTRIC Ayte9140d 79� 7 - Designer Signature , �AN11FACfUR 'k 4 2 c� C WCOMPLETE w z z Q N Z_ a o I'V �LLrn Z)z� LU oC rn 0 w Ln U = -0 c Ira z (D w CO z LU °C W lr) C = 2: o �0=�J �D Revisions Table Description I Date I Rev. COMPONENT WEIGHT QTY TOTAL WEIGHT Sheet Name & Creation Date STRING ATTACHMENT 01/24/2025 MODULES (PER PIECE) 48.50 Ibs 18 873.00 Ibs INVERTERS PER PIECE 2.40 Ibs 18 43.20 Ibs SOLAR FOOT (PER PIECE) 1.00 Ibs 43 43.00 Ibs INVISIMOUNT (PER LINEAL FOOT) 6.00 Ibis 16 96.00 Ibs MIDS (PER PIECE) 0.14 Ibis 26 3.64 Ibs Sheet Number PV- 1, 1 ENDS (PER PIECE) 0.24 Ibis 20 4.80 Ibs SPLICES (PER PIECE) 0.60 Ibis 6 3.60 Ibs COMPONENTS TOTAL WEIGHT 1067.24 lbs INTERIOR WALL 1 \, EQUIPMENT ELEVATION EXTERIOR WALL EXTERIOR WALL WOLF RIVER ELECTRIC WOLF RIVER ELECTRIC 101 ISANTI PARKWAY NE, SUITE G ISANTI, MN 55040 ELECTRICAL LICENSE: EA777669 Building License BC773271 Contact: (763) 229-6662 contact@wolfriverelectric.com DESIGNED BY: WOLF RIVER ELECTRIC Designer Signature %pR4fACTU#..*�o� f x c, W C S � a COMPLETE Z w z z Q N z �:a w z � Lr) = ��o= -0 Lr) Z az w = m�z(D Lr) O w 3: N C = o=� Q_j Revisions Table Description I Date I Rev. Sheet Name & Creation Date EQUIPMENT ELEVATION 01/24/2025 Sheet Number SCALE: NTS PV 1.2 PV-1.2 GENERAL STRUCTURAL NOTES THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING . (THE PEGASUS COMP MOUNT & SUNPOWER INVISIMOUNT RAIL SYSTEM), AND MUST BE STAGGERED TO ADJACENT FRAMING MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD. B. UNLESS NOTED OTHERWISE, MOUNTING ANCHORS SHALL BE 16" LAG SCREWS WITH A MINIMUM OF 2 V2" PENETRATION INTO ROOF FRAMING C. THE PROPOSED PV SYSTEM ADDS 3.0 psf TO THE ROOF FRAMING SYSTEM 1. ROOF LIVE LOAD = 35 psf TYPICAL, 0 psf UNDER NEW PV SYSTEM. 2. GROUND SNOW LOAD = 50 psf 3. WIND SPEED = 115 mph EXPOSURE CATEGORY = C 1 D-2.0 ATTACHMENT DETAIL SCALE: NTS OF THE ROOF TO TOP OF PANEL GROUNDING & END/MID CLAMP (E) COMP SHINGLE ROOF MI / A Af %Ml 11 =0 M., ALE SUNPOWER INVISIMOUNT RAIL INSTAFLASH-FOOT " SS LAG BOLT WITH MIN 2 2" ,D EMBEDMENT, SEALED WOLF RIVER ELECTRIC WOLF RIVER ELECTRIC 101 ISANTI PARKWAY NE, SUITE G ISANTI, MN 55040 ELECTRICAL LICENSE: EA777669 Building License BC773271 Contact: (763) 229-6662 contact@wolf rive relectric.com DESIGNED BY: WOLF RIVER ELECTRIC � � r Designer Signature A r4rdlw`P-1�1*1`1 1 y COMPLETE z o a o N � � LU z � � U z � a� _ Ln a z w =_ �c r z m `zQw o �o=�J Revisions Table Description I Date I Rev. ■ Sheet Name & 2"X4" TRUSS 24" OC PENETRATION INTO TRUSS. Creation Date VECTOR E r1 O I Il E E R 9 P LACA R D 851 W, GALENA PARK SLVD, 5TE, ICI PHONE 18Q71 99Q� i775 c RAPER, UTAH B4020 www. vECTnrzSE.cnM SHEET LICENSED �'�•P 2 ATTACHMENT DETAIL(ENLARGED VIEW Vector a with Structural Engineering has reviewed the existing ROFESSION& structure with loading from the solar array and screw BEN I connections to the existing framing. The design of the O ^'� A +"� O+"1 racking system, racking connections, and all other — LG.f L L structural is by others_ Mechanical, architectural, and all SCALE: NTS other nonstructural aspects of the design are by others q D-2.0 Electrical is by others, unless stamped by Dean Levorsen. d 25 Of� Sheet Number I hereby certify that this plan, specification or report � /�� ll� t�� \ �`,, was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota, 01/31/2025 D-2.0 Kelly G. Springer, License No. 60925, VSE Project Number: U3594.0103.251 Expiration Date: 30-June-2026 NOTES 1. THIS DRAWING IS FOR ILLUSTRATIVE PURPOSES ONLY! 2. ALL TESTING SHALL BE PERFORMED BY QUALIFIED PERSONNEL, WITH PROPER PERSONAL PROTECTIVE EQUIPMENT. 3. 24/ 7 UNESCORTED KEYLESS ACCESS IS TO BE PROVIDED FORALL UTILITY EQUIPMENT. 4. THE PRODUCTION METER & AC DISCONNECT SHOULD BE LOCATED TOGETHER VISIBLE -OPEN LOCKABLE READILY ACCESSIBLE LOCATION WITHIN 10' OF THE MAIN SERVICE METER. 5. THE METER SOCKET FOR THE PV PRODUCTION METER SHALL BE MARKED WITH A STAMPED BRASS, ALUMINUM, OR STAINLESS STEEL TAG, INDICATING THE ADDRESS INCLUDING THE UNIT, TYPICALLY "PV PROD" IN ACCORDANCE WITH THE REQUIREMENTS FOR "METER IDENTIFICATION" IN SECTION 4.14.4 OF THE XCEL ENERGY STANDARD, OR AS MAY BE AMENDED. 6. THE PV PRODUCTION METER SHALL BE LOCATED WITHIN TEN (10) FEET OF THE EXISTING UTILITY METER. IF THERE IS ANY REASON THIS CANNOT BE ACCOMPLISHED, THE APPROVAL OF THE PROPOSED PV PRODUCTION METERING WILL NEED TO BE OBTAINED BY THE LOCAL ELECTRIC METER SHOP. 1 %% 1 11 A r% r% 1 11 r M A TT R Er" /'-'% IQ7HS Photovoltaic System DC SYSTEM SIZE 7.470 kW AC SYSTEM SIZE 6.912 kW TOTAL MODULE COUNT 18 NOTE: AC DISCONNECT TO BE INSTALLED WITHIN 10FT FROM UTILITY METER. AHJ: HENNEPIN COUNTY UTILITY: WRIGHT HENNEPIN CONDUCTOR SCHEDULE SPECIFIED CONDUCTORS SHALL BE COPPER UNLESS OTHERWISE SPECIFIED TAG # DESCRIPTION 1 INVERTER OUTPUT (TRUNK CABLE) EGC(BARE COPPER GROUND 2 INVERTER OUTPUT (THWN-2) EGC(THWN-2) 3 INVERTER OUTPUT(THWN) EGC(THWN) 4 INVERTER OUTPUT(THWN) 5 1 INVERTER OUTPUT(THWN) WIRE GAUGE # OF CONDUCTORS/COLOR 12 AWG 6(31-1, 31-2) 6 AWG 1 BARE 12 AWG 6(3L1, 3L2) 12 AWG 1(GRN) 6 AWG 3(L1,L2,N) B/R/W 10 AWG 1(GRN) 6 AWG 3(L1,L2,N) B/R/W 4/0 AWG AL I 3(L1,L2,N) B/R/W CONDUIT TYPE I CONDUIT SIZE FREE AIR FMC SCH 80 PVC SCH 80 PVC 041F."Iffl li N/A 3/4" WOL"F�RIVER ELECTRIC 1`f WOLF RIVER ELECTRIC 101 ISANTI PARKWAY NE, 1�� SUITE G ISANTI, MN 55040 2" ELECTRICAL LICENSE: EA777669 Building License BC773271 Contact: (763) 229-6662 contact@wolf rive relectric.com ;ISITING UTILITY METER -PHASE, 3W 120V/240V NEW UTILITY EXPORT METER MILBANK U4801 -XL-TG-KK 1-PHASE 3-WIRE 120/240V EXISTING 240V/200A BUSBAR RATING, SERVICE PANEL SINGLE PHASE WITH 100A DISCONNECT DESIGNED BY: WOLF RIVER ELECTRIC -AW96-7 6ni- Designer Signature Q*�iy , �p1�11FACTl/� f * �D�fi H L IW � C tl COMPLETE _ KY w z z Q N z CD a o [V � z oC z �o LMn U _ Ln Z m > CL w (D w Im z oC w Ln � _ ° �0 :D :D Revisions Table Description I Date I Rev. ■ Sheet Name & Creation Date 3-LINE SHEET VISIBLE OPEN LOCKABLE #6 AWG COPPER 01/24/2025 Sheet Number READILY ACCESSIBLE GROUND REFERENCE POINT NEW GROUNDING D-2.1 OF APPLICABILITY ELECTRODE SYSTEM ti- CAUTION ! MULTIPLE SOURCES OF POWER POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN AIN SERVICE PANEL UTILITY EXPORT ETER UTILI UTILI DISCONNE ETER w F R IVER ELECTRIC WOLF RIVER ELECTRIC 101 ISANTI PARKWAY NE, SUITE G ISANTI, MN 55040 ELECTRICAL LICENSE: EA777669 Building License BC773271 Contact: (763) 229-6662 contact@wolf rive relectric.com DESIGNED BY: WOLF RIVER ELECTRIC Awo 7 6n/ J�r Designer Signature A r4rdlw`P-1�1*1`1 1 y COMPLETE z CD o N � 5 z n °CMowN = M 70 U) � i LU z w m O z Lu w Ln = � N o L - o = J J aF- F- Z)D Revisions Table Description I Date I Rev. ■ Sheet Name & Creation Date PLACARD SHEET Serviced by Wolf River Electric 01Sheet Number Num�r Contact: (763) 229m6662 I D-2.2 AWARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: COMBINER PANEL, AC DISCONNECT, POINT OF INTERCONNECTION PER CODE: NEC 706.15(C)(4), NEC 690.13(B) AWARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT IOR TO WORKING INSIDE PANEL LABEL LOCATION: COMBINER PANEL(S), MAIN SERVICE DISCONNECT PER CODE: NEC 110.27(C), OSHA 1910.145(f)(7) LABEL LOCATION: DC CONDUITIRACEWAYS PER CODE: NEC 690.31(D)(2) LABEL LOCATION: AC DISCONNECT/POINT OF INTERCONNECTION PER CODE: NEC 690.54 LABEL LOCATION: AC DISCONNECT PER CODE: NEC 690.13(B) WARNINGDUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM LABEL LOCATION: MAIN SERVICE DISCONNECT, PRODUCTIONINET METER PER CODE: NEC 690.59, 705.12(C) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE SOLAR ELECTRIC "OFF" POSITION TO PV PANELS SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY LABEL LOCATION: MAIN SERVICE DISCONNECT PER CODE: NEC 690.56(C) LABEL LOCATION: MAIN SERVICE DISCONNECT, UTILITY METER PER CODE: NEC 690.13(B) LABEL LOCATION: RSD INITIATION DEVICE, AC DISCONNECT PER CODE: NEC 690.56(C)(2) LABEL LOCATION: MAIN SERVICE DISCONNECT PER CODE: NEC 690.15(B) &NEC 690.33(D)(2) F A - WOLF �,R N ELECTRIC WOLF RIVER ELECTRIC 101 ISANTI PARKWAY NE, SUITE G ISANTI, MN 55040 ELECTRICAL LICENSE; EA777669 Building License BC773271 Contact: (763) 229-6662 contact@wolfriverelectric.com DESIGNED BY: WOLF RIVER ELECTRIC Designer Signature %AwuFac TURD. % y ix G7 C S � COMPLETE a w z z Q N �: a w �u') M Dz O a)Ln U= 11J -0 Ln z >1 _ m � w z � �0 �O=� Q� Revisions Table Description I Date I Rev. Sheet Name & Creation Date WARNING SHEET 01/24/2025 Sheet Number D-2.3 Surge Protection You Can Count on! MidNite Solar Surge Protection Devices are type 1 devices, designed for indoor and outdoor applications. Engineered for both AC and PV DC electrical systems, they provide protection to service panels, load centers or electronic devices that are directly connected to a MidNite Surge Protection Device (SPD). MidNite's SPD's are offered in four models to protect a variety of different voltage ranges. They achieve this protection by clamping surge voltage to a level that your system can sustain without damaging the components of the system. Compare our SPD's against other surge protec- tion devices. You will see there is no compari- son in both our price and features. All our SPD's have a 5 year warranty. With lightning you only get one chance, so get the best! www.midnitesolar.com/spd 19115 - 62nd Ave. NE., Arlington, WA. 360-403-7207 FAX: 360-691-6862 Nik. MNSPD300ACFM (Cut -in box) (MNSPD-300-AC included) Four Models: MNSPD-115 MNSPD-300-AC MNSPD-300-DC MNSPD-600 MIfflTC- E1� 11 I KAN V inc ) �r3Ya � - Liu j PART NUMBER MNSPD-115 MNSPD-300-AC MNSPD-300-DC MNSPD-600 Nominal Voltage 0 to 90 VAC 0 to 250 VAC 0 to 300 VDC 0 to 480 VAC 0 to 115 VDC 0 to 600 VDC MCOV F_ 180V 470V 470V 780V VPR Line to Ground 600V 1200V 1200V 1800V Suggested Placement Up to 90VAC circuits, 120/240 VAC circuits Off -grid PV combiners 316V/480 VAC circuits 12V, 24V, 48VDC battery Charge controller inputs Grid -tie PV combiners circuits up to 30OVDC Grid -tie inverter input Non -Isolated Inverters Type UL14494th Ed. Type 1 UL14494th Ed. Type 1 UL14494th Ed. Type 1 UL14494th Ed. Type 1 Diagnostic Blue LED MNSPD-300-AC LED indicates when voltage is present between L1 + ground and L2 + ground MNSPD-115, MNSPD-300-DC and MNSPD-600: LED indicates when voltage is present between L1 + L2 (PV+ PV-) Thermal Disconnector Internal Fuse Response Time <1 micro sec. r301AP, inc 3.82„ 24" Wiry 03.527- 5" Performance Surge Current Rating per Phase 80kA Short Circuit Current Rating 1 OkA Fusing Thermal Fusing Over current Fusing Operating Frequency Mechanical Description Enclosure Environmental Rating Connection Method Weight Mounting Method Operating Altitude Storage Temp Operating Temp Diagnostics Blue status LED, one per leg Individually fused MOVs Yes Yes 0 to 500 Hz Polycarbonate UL94V-0 Type 4X #12 AWG 1 lb. 1/2"Conduit Knockout Sea Level - 12,000' (3,658 Meters) -40° F to +185° F (-40° C to +850 C) -400 F to +1850 F (-40° C to +850 C) Listings and Performance LIL Standard for Safety, UL 1449 Surge Protective Devices -Fourth Edition CSA C22.2 No. 8-M1986 Electromangetic Interference (EMI) Filters, Fourth Edition Model No. Max Operating Surge Current 1 Configuration MCOV SCCR I VPR 60OV13kA Voltage per Phase I� I I I L G MNSPD-115 100 VAC/150VDC , � 80kA I 3-wire (2 Legs) 180V L-N 1 OkA I 600V MNSPD-300-AC 1300VAC 80kA 1103-wire (2 Legs) 470V L-N 10kA I 1200V MNSPD-300-DC i 385VDC , 80kA I 1 fr7 3-wire (2 Legs) , 470V L N 110kA I 1200V MNSPD-600 480VAC/600VDC 80kA 10, 3-wire (2 Legs) 780V L-N 1 OkA 1800V www.midnitesolar.com/spd 19115 - 62nd Ave NE, Arlington, WA 98223 PH. 360403-7207 FAX 360-691-6862 ©SERIES SUNPOWER"` Part of the SunPower Equinox" Solar System • Seamless aesthetics • Compatible with mySunPower monitoring Facto ry-integ rated Microinverter • Highest -power integrated AC module in solar • Engineered and calibrated by SunPower for SunPower AC modules 425-410 W Residential Black AC Module SunPower' Maxeon' Technology Built specifically for use with the SunPower Equinox® system, the only fully integrated solution designed, engineered, and warranted by one company. Highest Power Density Available i[ The patented, solid -copper foundation Maxeor Gen 6 cell is over 5% larger than prior generations, delivering the highest -efficiency all -black AC solar module available.1 suHPowe� ■ SunPower 1 ■ Complete f Confidence OSERIES �E Highest Lifetime Energy and Savings ©SERIES Designed to deliver 60% more energy over 25 years in real -world conditions like partial shade and high temperatures.2 15n°/ 14095 � 13095 � 1Zp9n � 11 n44 } � 9ovs c w 60'd6 a 7o% N 607n ] 5 10 15 20 25 Years of operation Best Reliability, Best Warranty Up to 60% More Lifetime Energy With more than 42.6 million and 15 GW of modules deployed around the world, SunPower technology is proven to last. That's why we stand behind our module and microinverter with the industry's best 25-year Combined Power and Product Warranty, including the highest Power Warranty in solar. M425-BLK I M415-BLK I M410-BLK SunPower Residential Black AC Module Inverter Model: Type H (Enphase IQ7HS) Max. Continuous Output Power (VA) Nom. (L-L) Voltage/Range' (V) Max. Continuous Output Current (A) Max. Units per 20 A (L-L) Branch Circuit' AC Electrical Data @240 VAC 384 240 / 211-264 1,60 10 @208 VAC 369 208 / 183-229 1.77 9 CEC Weighted Efficiency 97.0% 96.596 Nom. Frequency 60 Hz 60 Hz Extended Frequency Range 47-68 Hz 47-68 Hz AC Short Circuit Fault Current Over 3 Cycles 4.82 A 4.82 A Overvoltage Class AC Port III III AC Port Backfeed Current 18 mA 18 mA Power Factor Setting 1.0 1.0 Power Factor (adjustable) 0.85 {Inductive) / 0.85 (capacitive) 0.85 (inductive) / 0.85 (capacitive) DC Power SPR-M425-Ell Data SPR-M415-Ell SPIR-M410-BLiC-H-AC Nom. Powera (Pnom) W 425 415 410 Power Tolerance +5/-0% +5/-0% +5/-0% Module Efficiency 22.0% 21.5% 21.2% Temp. Coef. (Power) -0.29% / °C -0.29% / °C -0.29% / °C Shade Tolerance Integrated module -level max. power pointtracking Tested Operating Conditions Operating Temp. -40' F to +185' F (-40° C to +85' C) Max. Ambient Temp. 122° F (50- Q Max. Test Load' Wind: 125 psf, 6000 Pa, 611 1 back Snow: 187 psf, 9000 Pa, 917 kg/mz front Max. Design Load Wind: 75 psf, 3600 Pa, 367 1 back Snow: 125 psf, 5400 Pa, 550 kg/ml front Impact Resistance 1 inch (25 mm) diameter hail at 52 mph (23 rr/s) Solar Cells Mechanical Data 66 MdXeOn Gen 6 Front Glass High -transmission tempered glass with anti -reflective coating Environmental Rating Outdoor rated Frame Class 1 black anodized (highest AAMA rating) Weight 48 Ibs (21.8 kg) Recommended Max. Module Spacing 1.3 in. (33 mm) 1 Based on datasheet review of websites of tap 20 manufacturers per IHS, as ofjuly 2021, 2 Maxeon 435 w, 22.5%efficient, compared to a Conventional Panel on same -sized arrays (300 W, 19% efficient, approx. 1,b mi 7.9% more energy per watt (based on PVSyst pan f les for avg, US climate), 0.5%lyr slower degradation rate Qordan, et. ai, 'Robust PV Degradation Methodology and Application "i 2018). 3 Based on search of datasheet values from websites of top 10 manufacturers peril as of June 2021. 4 Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area 5 Factory set to IEEE 1547a-2014 defauit settings. CA Rule 21 default settings profile set during commissioning, 6 Standard Test Conditions (1000 W/mz irradiance, AM 1.5, 25°C). All DC voltage is fully contained within the module. 7 UL Listed as PVRSE and conforms with NEC 2014 and NEC 2017 690.12; and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors; when installed according to manufacturers instructions, 8 Please read the safety and installation instructions for more information regarding load ratings and mounting configurations, See wvvw,5uripower.com/company for more reference information. For more details, see extended datasheet: www.sunpcwer.com/solar-resources. Specifications included in this datasheet are suhject to change without notice. 02022 SunPower Corporation, All rights reserved. SUNPOWER, the SUNPOWER logo and EQUINOX are registered trademarks of SunPower Corporation in the U.S. MAXEON is a registered trademark of Maxeon Solar Technologies, Ltd. For more information visit wvvw.Maxe0n.com/legal. Warranties 25-year limited power warranty 25-year limited product warranty UL 1741 / IEEE-1547 UL 1741 AC Module UL 61730 Cfype 2 fire rated) UL 62109-1 / IEC 62109-2 FCC Part 15 Class B ICFS-0003 Class B CAN/CSA-C22.2 NO. 107.1-01 CA Rule 21 (UL 1741 SA)s Certifications (includes Volt/Var and Reactive Power Priority) and UL Listed PV Rapid Shutdown Equipment' Compliance Enables installation in accordance with: NEC 690.6 (AC module) NEC 690.12 Rapid Shutdown (inside and outside the a rray) NEC 690.15 AC Connectors, 690.33(A)-(E)(1) When used with AC module Q Cables and accessories (UL 6703 and UL 2238)' • Rated for load break disconnect PID Test 1000 V: IFC 62804 Packaging Modules per pallet Configuration 25 Packaging box dimensions 75A x 42.2 x 48.0 in. (1915 x 1072 x 1220 mm) Pallet gross weight 130.0 lb (590 kg) Pallets per container 32 Net weight per container 18,880 kg 73.7 in j173. mm7 �I FRAME PROFILE Grounding Holler, ❑ A m a (A) Long Side: 1.3 in (32 mm) Short Side: 0.9 in (24 mm) Please read the safety and installation Instructions for details. UL w�wcSVF �n 544400 RevA usrElo83 rwdd.F„�Perb---- 7TYm2 January 2022 ENPHASE DATA SHEET IQ7HS Microinverter The high-powered, smart grid -ready IQ7HS Microinverter with integrated MC4 connectors dramatically simplifies installation while achieving the highest system efficiency. rt Part of the Enphase Energy System, the I07HS Microinverters integrate with the IQ Gateway, IQ Battery, and the Enphase Installer App monitoring and analysis software. Connect PV modules quickly and easily to the IQ7HS Microinverters that have integrated MC4 connectors. IQ7HS Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power - on testing, enabling Enphase to provide an industry -leading warranty of up to 25 years. I07HS Microinverters are UL Listed as PV rapid shutdown equipment and conform with various regulations when installed according to the manufacturer's instructions. Easy to install Lightweight and simple Faster installation with improved, lighter two -wire cabling Built-in rapid shutdown compliant (NEC 2014, 2017, 2020, and 2023) Productive and reliable Optimized for high powered 60-cell/120-half-cut-cell, 66-cell/ 132-half-cut-cell, and 72-cell/ 144-half-cut-cell PV modules More than a million hours of testing Class II double -insulated enclosure UL Listed Smart grid -ready Complies with advanced grid support, voltage, and frequency ride -through requirements Remotely updates to respond to changing grid requirements Configurable for varying grid profiles Meets CA Rule 21(UL 1741-SA) and IEEE 1547:2018 (UL 1741-SB, 3rd Ed.) for single-phase systems © 2024 Enphase Energy. All rights reserved. Enphase, the a and CC logos, IQ and certain other marks listed at enphase.com/trademark-usage-quidelines are trademarks of Enphase Energy, Inc. in the U.S. and other countries. Data subject to change. DSH-00562-1.0- EN-US-2024-08-02 1Q7HS Microinverter Commonly used module pairings' Module compatibility Maximum input DC voltage Peak power tracking voltage Operating range Minimum/Maximum start voltage Maximum input DC short-circuit current Maximum module s� Overvoltage class DC port DC port back -feed current PV array configuration Peak output power Maximum continuous output power Nominal (L-L) voltage/Range2 Maximum continuous output current Nominal frequency Extended frequency range AC short-circuit fault current over three cycles Maximum units per 20 A (L-L) branch circuit' Overvoltage class AC port AC port back -feed current Power factor setting Power factor (adjustable) CEC weighted efficiency Ambient temperature range Relative humidity range DC connector type Dimensions (H x W x D) Weight Cooling Approved for wet locations Pollution degree W 320-460 — 60-cell/120-half -cut-cell, 66-cell/132-half-cut-cell, and 72-cell/144-half -cut-cell PV modules V 59 V 38-43 V 20-59 V 30/59 A 25 A 20 A 0 1 x 1 ungrounded array; no additional DC side protection required; AC side protection requires max. 20 A per branch circuit VA 384 @ 240 VAC, 369 @ 208 VAC VA 384 @ 240 VAC, 369 @ 208 VAC V 240/211-264, 208/183-229 1.60 A (240 V),1.77 A (208 V) Hz 60 Hz 47-68 Arms 4.82 10 (240 VAC), 9 (208 VAC) — III mA 18 1.0 0.85 leading... 0.85 lagging 97.0 @ 240 V, 96.5 @ 208 V °C VF) -40 to 60 (-40 to 140) 4 to 100 (condensing) — Staubli MC4 mm (in) 212 (8.3) x 175 (6.9) x 30.2 (1.2) without bracket kg (lb) 1.1 (2.4) — Natural convection —no fans — Yes — PD3 Pairing PV modules with wattage above the limit may result in additional clipping losses. See the compatibility calculator at enphase.com/installers/microinverters/calculator. z Nominal voltage range can be extended beyond nominal if required by the utility. a Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. DSH-00562-1.0-EN-US-2024-08-02 Enclosure — Class II double -insulated, corrosion -resistant polymeric enclosure Environmental category/UV exposure — NEMA type 6/Outdoor rating Communication Power line communication (PLC) Monitoring Enphase Installer App and monitoring options Compatible with IQ Gateway Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load -break disconnect means required by NEC 690 and C22.1-2018 Rule 64-220. CA Rule 21(UL 1741-SA), IEEE 1547:2018 (UL 1741-SB 30 Ed.) for single-phase systems HEI Rule 14H SRD 2.0 UL 62109-1, FCC Part 15 Class B, ICES-0003 Class B Compliance CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014. NEC 2017, and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 rapid shutdown of PV systems for AC and DC conductors, when installed according to manufacturer's instructions. DSH-00562-1.0-EN-US-2024-08-02 Revision history DSH-00562-1.0 August 2024 Initial release. © 2024 Enphase Energy. All rights reserved. Enphase, the a and CC logos, IQ, and certain other marks listed at enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the U.S. and other countries. Data subject to change. DSH-00562-1.0-EN-US-2024-08-02 ENPHASE. DATA SHEET IQ Combiner 4/4C The Enphase IQ Combiner 4/4C with IQ Gateway and integrated LTE-Ml cell modem (included only with IQ Combiner 4C) consolidates interconnection equipment into a single enclosure and streamlines IQ Microinverters and storage installations by providing a consistent, pre -wired solution for residential applications. It offers up to four 2-pole input circuits and an Eaton BR series busbar assembly. It L IQ Series Microinverters IQ System Controller 2 The high-powered smart grid -ready IQ Series Provides microgrid interconnection device Microinverters (I06, IQ7, and I08 Series) (MID) functionality by automatically detecting dramatically simplify the installation process. grid failures and seamlessly transitioning the home energy system from grid power to backup power. IQ Battery All -in -one AC coupled storage system that is reliable, smart, simple, and safe. It provides backup capability, and installers can quickly design the right system size to meet the needs of both new and retrofit solar customers. NOM, 5-year limited warranty IQ Load Controller Helps prioritize essential appliances during a grid outage to optimize energy consumption and prolong battery life. 'Refer to the https://enphase.com/installers/resources/warranty page for country -specific warranty information. X-I0-AM1-240-4 X2-IQ-AM1-240-4 (IEEE 1547:2O18) X-IQ-AM1-240-4C X2-IQ-AM1-240-4C • (IEEE 1547:2O18) $mart Includes IQ Gateway for communication and control Includes Enphase Mobile Connect cellular modem (CELLMODEM-Ml-O6-SP-05), included only with IQ Combiner 4C Includes solar shield to match IQ Battery aesthetics and deflect heat Flexible networking supports Wi-Fi, Ethernet, or cellular Optional AC receptacle available for PLC bridge Provides production metering and consumption monitoring $imple Centered mounting brackets support single stud mounting Supports bottom, back and side conduit entry Up to four2-polebranch circuits for 240 VAC plug-in breakers (not included) 80 A total PV or storage branch circuits Reliable Durable NRTL-certified NEMA type 3R enclosure Five-year limited warranty Two -years labor reimbursement program coverage included for both the IQ Combiner SKU's UL Listed X2-IQ-AM1-240-4 and X2-IQ-AMt-240-4C comply with IEEE 1547:2018 (UL 1741-SB, 3rd Ed.) © 2024 Enphase Energy. All rights reserved. Enphase, the a and CC logos, la and certain other marks listed at https:/Ienphase.com/trademark-usage-guidelines are trademarks of Enphase Energy. Inc. in the U.S. and other countries. Data subject to change. IRC-4-40-DSH-00217-3.0-EN-US-2024-08-16 IQ Combiner 4/4C IQ Combiner 4 (X-IQ-AM1-240-4, X2-IQ-AM1-240-4) IQ Combiner 4C (X-I0-AMl-240-4C, X2-I0-AMl-240-4C) IQ Gateway printed circuit board Busbar IQ Gateway breaker Production CT Consumption CT Emphase Mobile Connect (only with IQ Combiner 4C) Supported microinverters Enphase Communications Kit COMMS-CELLMODEM-M1-06 CELLMODEM-M1-06-SP-05 CELLMODEM-M1-06-AT-05 Circuit breakers (off -the -shelf) Circuit breakers (provided by Enphase) XA-SOLARSHIELD-ES XA-ENV2-PCBA-4 XA-PLUG-120-3 X-IQ-NA-HD-125A Rating System voltage and frequency Busbar rating Fault current rating Maximum continuous current rating (input from PV/storage) Maximum fuse/Circuit rating (output) Branch circuits (solar and storage) IQ Combiner 4 with an IQ Gateway printed circuit board for integrated revenue -grade PV production metering (ANSI C12.20 ±0.5%) and consumption monitoring (±2.5%). Includes a silver solar shield to match the IQ Battery and IQ System Controller 2 and to deflect heat. IQ Combiner 4C with an IQ Gateway printed circuit board for integrated revenue -grade PV production metering (ANSI C12.20±0.5%) and consumption monitoring (±2.5%),Includes Enphase Mobile Connect cellular modem (CELLMQDEM-M1-06-SP-05), a plug -and -play — industrial -grade cell modem for systems up to 60 microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, where there is adequate cellular service in the installation area). Includes a silver solar shield to match the IQ Battery and IQ System Controller 2 and to deflect heat. _ IQ Gateway is the platform for total energy management for comprehensive, remote maintenance, and management of the Enphase Energy System. 80 A busbar with support for one IQ Gateway breaker and four 20 A breakers for installing IQ Series Microinverters and IQ Battery A Circuit breaker, 2-pole, 10/15 Pre -wired revenue -grade solid -core CT, accurate up to ±0.5% Two consumption metering split core or clamp -type CTs, shipped with the box, accurate up to ±2.5% 40-based LTE-Ml cellular modem (CELLMQDEM-MI-06-SP-05) with a five-year T-Mobile data plan — IQ6, IQ7, and IQ8. Do not mix IQ6/IQ7 Microinverters with IQ8 - Includes COMMS-KIT-01 and CELLMQDEM-M1-06-SP-05 with a 5-year T-Mobile data — plan for Enphase sites - 4G-based LTE-Ml cellular modem with a five-year T-Mobile data plan - 4G-based LTE-M1 cellular modem with a five-year AT&T data plan Supports Eaton BR2xx, Siemens 02xx and GE/ABB THQL21xx Series breakers (xx may — be 10,15, 20, 30, 40, 50, or 60). Supports Eaton BR220B, BR230B, and BR240B circuit breakers compatible with hold-down kit. _ BRK-l0A-2-240V, BRK-15A-2-240V, BRK-20A-2P-240V, BRK-15A-2P-240V-8, and BRK-20A-2P-240V-6 — Replacement solar shield for IQ Combiner 4/4C — IQ Gateway replacement printed circuit board (PCB) for IQ Combiner 4/4C — Accessory receptacle for power line carrier in IQ Combiner 4/4C (required for EPLC-01) — Hold-down kit for Eaton circuit breaker with screws A 80 — 120/240 VAC,120/208 VAC, 60 Hz A 125 WC 10 A A Maximum total branch circuit breaker rating A (input) To learn more about Enphase offerings, visit enphase.com. 64 90 Up to four 2-pole Eaton BR, Siemens Q, or GE/ABB THQL Series distributed generation (DO) breakers only (not included) 80 A of distributed generation/95 A with IQ Gateway breaker included IRG-4-40-DSH-00217-3.0-EN-US-2024-08-16 10 Gateway breaker A 10 A or 15 A rating GE/Siemens/Eaton included Production metering CT A 200 A solid core pre -installed and wired to IQ Gateway Consumption monitoring CT (CT-200-SPLIT/CT- A A pair of 200 A split core or clamp -type current transformers 200-CLAMP) Dimensions (W . H x D) cm [in] 37.5.49.5 x 16.8 (14.75 -19.5 - 6.63). Height is 53.5 (21.06) with mounting brackets Weight kg (Ib) 7.5 06.5) Ambient temperature range °C ["FI -40 to 46 (-40 to 115) Cooling — Natural convection plus a heat shield Enclosure environmental rating — Outdoor, NRTL-certified, NEMA type 3R, polycarbonate construction 20 A to 50 A breaker inputs:14 to 4 AWG copper conductors 60 A breaker branch input:4 to 1/0 AWG copper conductors Wire sizes — Main lug combined output: 10 to 2/0 AWG copper conductors Neutral and ground:14 to 1/0 copper conductors Always follow local code requirements for conductor sizing Altitude m IN Up to 2,600 (8,530) INTERFACES DESCRIPTIONCOMMUNICATION UNITS Integrated Wi-Fi _ B02.11b/g/n (dual band 2.4 GH7/5 GHz) for connecting the Enphase Cloud through the internet Wi-Fi range (recommended) m Ift] 10 (32.B) Ethernet _ Optional 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included) for connecting to the Enphase Cloud through the internet Digital 1/0 — Digital input/output for grid operator control USB 2.0 _ For Mobile Connect, Communications Kit 1 for IQ Battery 3/3T/10/10T, Communication Kit 2 for IQ Battery 5P Access point (AP) mode For connection between the IQ Gateway and a mobile device running the Enphase Installer — App Metering ports — Up to two Consumption CTs, one IQ Battery CT, and one Production CT Power line communication kHz 90-110 Web API — See https://developer-v4.enphase.com Local API — See Guide for local API CELLMODEM-M1-06-SP-05, CELLMODEM-MI-06-AT-05 (4G-based LTE-M1 cellular Cellular/Mobile Connect — modem). Note that an Enphase Mobile Connect cellular modem is required for all installations with Enphase IQ Batteries and/or IQ System Controllers CA Rule 21(UL 1741-SA) IEEE 1547:2018 - UL 1741-SB, 3rd Ed. (X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C) IQ Combiner with IQ Gateway CAN/CSA C22.2 No. 107.1, 47 CFR, Part 15, Class B, ICES 003, NOM-208-SCFI-2016 Production metering: ANSI C12.20 accuracy class 0.5 (PV production), UL 61010-1, CAN/CSA 22.2 No. 61010-1, IEEE 2030.5/CSIP Compliant COMPATIBILITY PV Microinverters I06. IQ7, and IQ8 Series Microinverters IQ System Controller EP200G101-M240US00 COMMS-KIT-01 IQ System Controller 2 EP200G101-M240US01 IQ Battery ENCHARGE-3-11P-NA, ENCHARGE-10-113-NA, ENCHARGE-3T-1P-NA, ENCHARGE-10T-1P-NA IQ System Controller 3 SC200D111C240US01, SC20OG111C24OUS01 COMMS-KIT-02' IQ Battery IQBATTERY-5P-IP-NA 'For information about 10 Combiner 4/4C compatibility with the 3rd-generation batteries, refer to the compatibility matrix. IQC-4-40-DSH-00217-3.0-EN-US-2024-08-16 Revision history DSH-00217-3.0 DSH-00217-2.0 DSH-00217-1.0 August 2024 April 2024 February 2024 Previous releases. Updated the system voltage value. Updated Sprint plan to T-Mobile data plan. Updated the UL smart mark. Initial release. © 2024 Enphase Energy. All rights reserved. Enphase, the a and CC logos, IQ, and certain other marks listed at https://enphase.com/trademark-usage-guidelines are trademarks of Erphase Energy, Inc. in the U.S, and other countries. Data subject to change. IRC-4-40-DSH-00217-3.0-EN-US-2024-08-16 Simple and Fast Installation Integrated module -to -rail grounding Pre -assembled mid and end clamps • Levitating mid clamp for easy placement Mid clamp width facilitates even module spacing Simple, pre -drilled rail splice UL 2703 Listed integrated grounding Flexible Design Addresses nearly all sloped residential roofs Design in landscape and portrait Rails enable easy obstacle management Customer -Preferred Aesthetics • #1 module and #1 mounting aesthetics Best -in -class system aesthetics Premium, low -profile design Black anodized components Hidden mid clamps and end clamps hardware, and capped, flush rails Part of Superior System Built for use with SunPower DC and AC modules Best -in -class system reliability and aesthetics Combine with SunPower modules and monitoring app Elegant Simplicity SunPower" InvisiMount"I is a SunPower-designed rail -based mounting system. The InvisiMount system addresses residential sloped roofs and combines faster installation time, design flexibility, and superior aesthetics. The InvisiMount product was specifically envisioned and engineered to pair with SunPower modules. The resulting system -level approach will amplify the aesthetic and installation benefits for both homeowners and installers. sunpower.com V� Module*! Mid Clamp and Rail Mid Clamp End Clamp Rail & Rail Splice Component InvisiMount ComponentDe Material Weight Mid Clamp Black oxide stainless steel AISI 304 63 g (2.2 oz) End Clamp Black anodized aluminum alloy 6063-T6 110 g (3.88 oz) Rail Black anodized aluminum alloy 6005-T6 830 g/m (9 oz/ft) Rail Splice Aluminum alloy 6.005-TS 830 g/m (9 oz/ft) Ground Lug Assembly 304 stainless (A2-70 bolt; tin-plated copper lug) 106.5 g/m {3.75 oz} End Cap Black acetal (POM) copolymer 10.4 g (037 oz) Composition Shingle Rafter Attachment Application Composition Shingle Roof Decking Attachment Curved and Flat Tile Roof Attachment Universal Interface for Other Roof Attachments *Mud ule frame that is compatible with the Invisi Mount system required for hardware interoperability. Module* / End Clamp and Rail F-.0mgPopw Ground Lug Assembly 10 End Cap 1: Mount Warranties 25-year product warranty 5-year finish warranty UL 2703 Listed Certifications Class Afire rating when distance between roof surface and bottom of SunPower module frame is s 3.5" Roof Attachment Hardware Warral Refer to roof attachment hardware manufacturer's documentation 0 2015 Sun Power Corporation. All Rights Reserved. SUN POWER, the SUN POWER logo, and INVISIMOUNT are trademarks or registered trademarks of SunPower Corporation. All other trademarks are the property of their respective owners, Specifications included in this datasheet are subject to change without notice. sunpower.com Document #509506 Rev B A 25-Year Warranty Manufactured with advanced materials and coatings to outlast the roof itself INSTAFLASH'" Code Compliant Fully IBC/CBC Code Compliant Exceeds ASCE 7-16 Standards FL Cert of Approval FL41396 UL2703 Certified 00 ■ 100 Self -Healing The proprietary non -hardening sealant will flex and reseal over years of thermal expansion and contraction ono Larger Spans The extra -large L-foot and proprietary lag screw result in larger spans between mounts Pegasus Solar Inc 1 506 West Ohio Avenue, Richmond, CA 94804 1 www.pegasussolar.com 1 Drill pilot hole in the center of the rafter using a 7/32" bit. 3 Insert the lag screw through the center hole into the pilot hole. r' Place the InstaFlash over the pilot hole. Note: the direction of the InstaFlash Down arrows should point down the roof. 4 Drive the lag until the InstaFlash is fully seated to the roof - PIF-RBO PIF-RBDT PIF-RBSH PIF-RMO PEF-RMDT Finish Black Mill ❑� ''❑� � Black InstaFlash, Black InstaFlash, Black InstaFlash, Mill Insta- Mill InstaFlash, Kit Contents 5/16" x 4.0" SS 5/16" x0" SS Lag, 5/16" x 4.0" SS Lag, Flesh, S Lag a I 5/l M10 Hex Bolt w/ Nut Lag, Dovetail tail ❑� Nut SS Lag T-bolt w/ Nut Attachment Type Rafter Attached SCAN FOR Roof Type � Sloped Roof: Composition Shingle, Rolled Asphalt I Flat roof: Modified Bitumen Roof, Built -Up Roof INSTALLATION Sealant Application Factory Installed Installation 0°F to 170' F Temperature JA Cure Time Instantly Waterproof; Non -hardening Service Temperature -40°F to 1951 F Certifications IBC, ASCF/SFI 7-16, FL Cert of Approval F141396, TAS 100{A), 1112703 Install Application Most Railed Systems, Pegasus Tilt Leg Kit Kit Quantity 24 Boxes per Pallet irw 36 US Patents Pending. All rights reserved.02023 Pegasus Solar Inc. SCAN FOR FREE TRIAL MIL BANK® " ENE RGYAT WORK U4801-XL-5T9 Catalog Number U4801-XL-5T9 Marketing Product Description 5 Terminal Ringless Small Closing Plate Lever Bypass 5th Terminal 9 Oclock Position UPC 784572288218 Length (IN) 4.844 Width (IN) 13 Height (IN) 19 Brand Name Milbank Type Ringless Meter Socket Application Meter Socket Standard UL Listed;Type 3R Voltage Rating 600 Volts Alternating Current ' Amperage Rating 200 Continuous Ampere Phase 1 Phase Frequency Rating 60 Hertz Size 4.844L x 13W x 19H Number Of Cutouts 0 Cutout Size No Main Breaker Cable Entry Overhead or Underground Terminal Lay in Insulation Glass Polyester Mounting Surface Mount Enclosure Jaw Quantity Bypass Type Number of Meter Positions Equipment Ground Hub Opening Line Side Wire Range Load Side Wire Range Number Of Receptacles G90 Galvanized Steel with Powder Coat Finish 5 Terminal Lever Bypass 1 Position Bonded Ground Strap Small Closing Plate 6 AWG - 350 kcmil 6 AWG - 350 kcmil 0 Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation. ceus LISTED PART # FIG. # Y" "" RAN E HEX SIZE L W H IT4 1 4- 14 SLOTTED 1.12 1.18 1.38 IT04 4 4 - 14 SLOTTED 1.12 1.25 1.38 IT] /0 1 1 /0 - 14 3/16 1.62 1.62 1.75 ITO 1 /0 4 1 /0 - 14 3/ 16 1.62 1.75 11.75 IT3/0 1 3/0-6 1 /4 1.84 1.75 11.87 IT03/0 4 3/0-6 1 /4 1.84 1.87 1.87 IT250 2 250 - 6 5/ 16 2.12 2.25 2.25 IT350 2 350 - 6 5/ 16 2.47 2.50 2.44 IT500 2 500 - 4 5/ 16 2.81 2.87 2.94 IT750* 2 750 - 250 3/8 3.48 3.50 3.50 IT600tt 2 600 - 6 5/ 16 2.34 2.94 3.05 ITH750 3 750 - 250 5/16 3.48 4.50 3.50 tt 600 SERIES ARE AL7CU AND 750C *NOT UL LISTED FIGURE 2 DUAL ENTRY FIGURE 4 ITO CONTACT NSi FOR SALES @ 800.321.5847 NOTES: PROPRIETARY AND CONFIDENTIAL 1. CONNECTOR MANUFACTURED FROM 6061-T6 ALUMINUM ALLOY. THE INFORMATION CONTAINED IN THIS 2. ULLLLISTED PER UL486A/B SPECIFICATIONS FOR 600V, DRAWINGPOLARIS TLESCO.INCOLE PANYOF PDLARIS SALES CO. INC. ANY OR AS A 3. DUAL RATED FOR 900C COPPER AND/OR ALUMINUM CONDUCTOR REPRODUCTION WTHOUTTHE WRITTENTPERMISSION OFE 4. COLD TEMPERATURE RATED TO -45°C. POLARIS SALES CO. INC. IS PROHIBITED. 5. HIGH DIELECTRIC STRENGTH INSULATION IS ABRASION, CHEMICAL I NAME DATE AND UV RESISTANT. CRAWNRY I S.PARRY 6/13/201 MATERIAL: N/A POLARIS SALES. CO. INC 11625 PROSPEROUS DRIVE ODESSA, FL 33556 TLE: IT SERIES INSULATED CONNECTORS IT SERIES HEET: 1 OF 1 ® VSE Project Number: U3594.0103.251 January 31, 2025 Wolf River Electric ATTENTION: Vladimir Marchenko 101 Isanti Parkway NE Isanti, MN 55040 REFERENCE: Suzanne Stauduhar Residence: 4725 Bayside Road, Maple Plain, MN 55359 Solar Array Installation To Whom It May Concern: We have reviewed the existing structure at the above referenced site.The purpose of our review was to determine the adequacy of the existing structure to support the proposed installation of solar panels on the roof as shown on the panel layout plan. Based upon our review, we conclude the existing structure is adequate to support the proposed solar panel installation. Design Parameters Code: 2020 Minnesota Residential Code (2018 IRC) Risk Category: II Design wind speed, Vult: 115 mph (3-sec gust) Wind exposure category: C Ground snow load, Pg: 50 psf Existing Roof Structure Roof structure: 2x4 manufactured trusses @ 24" o.c. Roofing material: asphalt (composite) shingles Roof 1: roof pitch of 3.8:12 Roof 2: roof pitch of 6:12 Connection to Roof Mounting connection: (1) 5/16" lag screw w/ min. 2.5" threaded embedment into framing at max. 48" o.c. along rails • Install (2) rails per row of panels, evenly spaced from panel center • Panel length perpendicular to the rails shall not exceed 74 in • Rail cantilever shall not exceed the lesser of 50% of the connection spacing or max cantilever allowed by manufacturer • At flat hip framing, if occurs, reduce connection spacing listed above by 50% or see attached detail for blocking option. • Connections shall be staggered so as not to overload any existing structural member 651 W. Galena Park Blvd., Ste. 101 / Draper, UT 84020 / T (801) 990-1775 / F (801) 990-1776 / www.vectorse.com Reviewed for Code Compliance Nicole Post SES25-000001 2-4-25 Approved plans must be on site for the duration of the project. Plans must be available to inspector. Please call 952-249-6000 to schedule all inspections. Have permit number and address when calling. Separate Permits Required Electrical ® VSE Project Number: U3594.0103.251 Suzanne Stauduhar Residence 1/31/2025 Conclusions Based upon our review,we conclude the existing structure is adequate to support the proposed solar panel installation.The glass surface of the solar panels allows for a lower slope factor per ASCE 7,resulting in reduced design snow load on the panels.The gravity loads,and thus the stresses of the structural elements,in the area of the solar array are either decreased or increased by no more than 5%.Stress decreases or increases of no more than 5%are considered acceptable.Therefore,the structure is permitted to remain unaltered. The solar array will be flush-mounted (no more than 10"above the roof surface)and parallel to the roof surface.Thus,we conclude that any additional wind loading on the structure related to the addition of the proposed solar array is negligible. The attached calculations verify the capacity of the connections of the solar array to the existing roof against wind (uplift), the governing load case.Increases in lateral forces less than 10%are considered acceptable.Thus the existing lateral force resisting system is permitted to remain unaltered. Limitations Installation of the solar panels must be performed in accordance with manufacturer recommendations.All work performed must be in accordance with accepted industry-wide methods and applicable safety standards.The contractor must notify Vector Structural Engineering,LLC should any damage,deterioration or discrepancies between the as-built condition of the structure and the condition described in this letter be found.The use of solar panel support span tables provided by others is allowed only where the building type,site conditions,site-specific design parameters,and solar panel configuration match the description of the span tables.The design of the solar panels,solar racking (mounts,rails,etc.)and electrical engineering is the responsibility of others.Waterproofing around the roof penetrations is the responsibility of others.Vector Structural Engineering assumes no responsibility for improper installation of the solar array.Vector Structural Engineering shall be notified of any changes from the approved layout prior to installation. VECTOR STRUCTURAL ENGINEERING, LLC 01/31/2025 _______________________________________________________ Kelly Springer, P.E. Project Engineer Enclosures KGS/acs I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. Kelly Springer, License No. 60925, Expiration Date: 30-June-2026 01/31/2025 651 W. Galena Park Blvd., Ste. 101 / Draper, UT 84020 / T (801) 990-1775 / F (801) 990-1776 / www.vectorse.com ®I hereby certify that this plan, specificationor report was prepared by me or under mydirect supervision and that I am a dulyLicensed Professional Engineer under thelaws of the State of Minnesota,Kelly G. Springer, License No. 60925,Expiration Date: 30-June-202601/31/2025VSE Project Number: U3594.0103.251 JOB NO.:U3594.0103.251 SUBJECT:WIND PRESSURE ® Roof 1 PROJECT:Suzanne Stauduhar Residence Label:Note: Calculations per ASCE 7-10 SITE-SPECIFIC WIND PARAMETERS: Basic Wind Speed [mph]:115 Notes: Exposure Category:C Risk Category:II Importance Factor, I: ADDITIONAL INPUT & CALCULATIONS: Height of Roof, h [ft]:25 (Approximate)Hip? Comp/Cladding Location:Yes Enclosure Classification: Zone 1 GCp:0.9 Figure 30.4-2B (enter negative pressure coefficients) Zone 2 GCp:1.7 Zone 3 GCp:1.7 α:9.5 Table 26.9-1 zg [ft]:900 Table 26.9-1 Kh:0.95 Table 30.3-1 Kzt:1 Equation 26.8-1 Kd:0.85 Table 26.6-1 Velocity Pressure, qh [psf]:27.2 Equation 30.3-1 GCpi:0 Table 26.11-1 PRESSURES:Equation 30.9-1 Zone 1, p [psf]:24.3 psf (1.0 W, Interior Zones, beyond 'a' from roof edge) Zone 2, p [psf]:45.0 psf (1.0 W, End Zones, within 'a' from roof edge) Zone 3, p [psf]:45.0 psf (1.0 W, Corner Zones, within 'a' from roof corner) (a= 3 ft) Solar Panel Array Gable/Hip Roofs 7° < θ ≤ 27° Enclosed Buildings Components and Cladding Wind Calculations ()()piphGCGCqp−= JOB NO.:U3594.0103.251 SUBJECT:CONNECTION ® Roof 1 PROJECT:Suzanne Stauduhar Residence Calculate Uplift Forces on Connection Pressure (0.6 Dead -0.6 Wind) (psf) Max Trib. Width1 (ft) Max Trib. Area2 (ft2) Max Uplift Force (lbs) Zone 1 12.8 4.0 12.3 157 Zone 2 25.2 4.0 12.3 310 Zone 3 25.2 4.0 12.3 310 Calculate Connection Capacity Lag Screw Size [in]:5/16 Cd:1.6 NDS Table 2.3.2 Embedment3 [in]:2.5 Grade: Nominal Capacity [lbs/in]:205 NDS Table 12.2A Number of Screws:1 Prying Coefficient:1.4 Total Capacity [lbs]:586 Determine Result Maximum Demand [lbs]:310 Lag Screw Capacity [lbs]:586 Result:Capacity > Demand, Connection is adequate. Notes 1. 'Max Trib. Width' is the width along the rails tributary to the connection. 2. 'Max Trib Area' is the product of the 'Max. Trib Width' and 1/2 the panel width/height perpendicular to the rails. (2) rails per row of panels. Length of panels perpendicular to the rails shall not exceed 74". 3. Embedment is measured from the top of the framing member to the beginning of the tapered tip of the lag screw. Embedment in sheathing or other material is not effective. The length of the tapered tip is not part of the embedment length. SPF (G = 0.42) VECTOR STRUCTURAL ENGINEERS JOB NO.:U3594.0103.251 SUBJECT:GRAVITY LOADS ® Roof 1 PROJECT:Suzanne Stauduhar Residence GRAVITY LOADS Roof Pitch: 3.8 :12 ROOF DEAD LOAD (D) Increase due to pitch Material weight [psf] Asphalt (Composite) Shingles 1.05 2.0 1/2" Plywood 1.05 1.0 Framing 1.00 3.0 Insulation 1.00 0.5 1/2" Gypsum Clg.1.05 2.0 M, E & Misc 1.00 6.5 Total Existing Roof DL PV Array DL 1.05 3 DL:1.05 ROOF LIVE LOAD (Lr) Existing Design Roof Live Load [psf]20 ASCE 7-16 Table 4.3-1 Roof Live Load With PV Array [psf]0 SNOW LOAD (S):w/ Solar Array Roof Slope [x:12]:3.8 Roof Slope [°]:18 Ground Snow Load, pg [psf]:50 ASCE 7-16, Section 7.2 Terrain Category:C ASCE 7-16, Table 7.3-1 Exposure of Roof:Fully Exposed ASCE 7-16, Table 7.3-1 Exposure Factor, Ce:0.9 ASCE 7-16, Table 7.3-1 Thermal Factor, Ct:1.1 ASCE 7-16, Table 7.3-2 Risk Category:II ASCE 7-16, Table 1.5-1 Importance Factor, Is:1.0 ASCE 7-16, Table 1.5-2 Flat Roof Snow Load, pf [psf]:35 ASCE 7-16, Equation 7.3-1 Minimum Roof Snow Load, pm [psf]:0 ASCE 7-16, Section 7.3.4 Unobstructed Slippery Surface?Yes ASCE 7-16, Section 7.4 Slope Factor Figure:Figure 7-2b ASCE 7-16, Section 7.4 Roof Slope Factor, Cs:0.87 ASCE 7-16, Figure 7.4-1 Sloped Roof Snow Load, ps [psf]:30 ASCE 7-16, Equation 7.4-1 Design Snow Load, S [psf]:30 1.00 35 Design material weight [psf] 2.1 1.0 3.0 0.5 2.1 6.5 15.2 3.1 #VALUE! 2020 MRC, Section R324.4.1.1 Existing 35 3.8 18 50 C Fully Exposed 0.9 1.1 II 1.0 35 0 No Figure 7-2b JOB NO.:U3594.0103.251 SUBJECT:LOAD COMPARISON ® Roof 1 PROJECT:Suzanne Stauduhar Residence Summary of Loads Existing With PV Array D [psf]15 18 Lr [psf]20 0 S [psf]35 30 Maximum Gravity Loads: Existing With PV Array (D + Lr) / Cd [psf]28 20 ASCE 7-16, Section 2.4.1 (D + S) / Cd [psf]43 42 ASCE 7-16, Section 2.4.1 Maximum Gravity Load [psf]:43 42 Ratio Proposed Loading to Current Loading:98%OK The gravity loads, and thus the stresses of the structural elements, in the area of the solar array are either decreased or increased by no more than 5%. Stress decreases or increases of no more than 5% are considered acceptable. Therefore, the structure is permitted to remain unaltered. (Cd = Load Duration Factor = 0.9 for D, 1.15 for S, and 1.25 for Lr) JOB NO.:U3594.0103.251 SUBJECT:WIND PRESSURE ® Roof 2 PROJECT:Suzanne Stauduhar Residence Label:Note: Calculations per ASCE 7-10 SITE-SPECIFIC WIND PARAMETERS: Basic Wind Speed [mph]:115 Notes: Exposure Category:C Risk Category:II Importance Factor, I: ADDITIONAL INPUT & CALCULATIONS: Height of Roof, h [ft]:25 (Approximate)Hip? Comp/Cladding Location:Yes Enclosure Classification: Zone 1 GCp:0.9 Figure 30.4-2B (enter negative pressure coefficients) Zone 2 GCp:1.7 Zone 3 GCp:2.5 α:9.5 Table 26.9-1 zg [ft]:900 Table 26.9-1 Kh:0.95 Table 30.3-1 Kzt:1 Equation 26.8-1 Kd:0.85 Table 26.6-1 Velocity Pressure, qh [psf]:27.2 Equation 30.3-1 GCpi:0 Table 26.11-1 PRESSURES:Equation 30.9-1 Zone 1, p [psf]:24.3 psf (1.0 W, Interior Zones, beyond 'a' from roof edge) Zone 2, p [psf]:45.0 psf (1.0 W, End Zones, within 'a' from roof edge) Zone 3, p [psf]:69.2 psf (1.0 W, Corner Zones, within 'a' from roof corner) (a= 3 ft) Solar Panel Array Gable/Hip Roofs 7° < θ ≤ 27° Enclosed Buildings Components and Cladding Wind Calculations ()()piphGCGCqp−= JOB NO.:U3594.0103.251 SUBJECT:CONNECTION ® Roof 2 PROJECT:Suzanne Stauduhar Residence Calculate Uplift Forces on Connection Pressure (0.6 Dead -0.6 Wind) (psf) Max Trib. Width1 (ft) Max Trib. Area2 (ft2) Max Uplift Force (lbs) Zone 1 12.8 4.0 12.3 157 Zone 2 25.2 4.0 12.3 310 Zone 3 39.7 4.0 12.3 488 Calculate Connection Capacity Lag Screw Size [in]:5/16 Cd:1.6 NDS Table 2.3.2 Embedment3 [in]:2.5 Grade: Nominal Capacity [lbs/in]:205 NDS Table 12.2A Number of Screws:1 Prying Coefficient:1.4 Total Capacity [lbs]:586 Determine Result Maximum Demand [lbs]:488 Lag Screw Capacity [lbs]:586 Result:Capacity > Demand, Connection is adequate. Notes 1. 'Max Trib. Width' is the width along the rails tributary to the connection. 2. 'Max Trib Area' is the product of the 'Max. Trib Width' and 1/2 the panel width/height perpendicular to the rails. (2) rails per row of panels. Length of panels perpendicular to the rails shall not exceed 74". 3. Embedment is measured from the top of the framing member to the beginning of the tapered tip of the lag screw. Embedment in sheathing or other material is not effective. The length of the tapered tip is not part of the embedment length. SPF (G = 0.42) VECTOR STRUCTURAL ENGINEERS JOB NO.:U3594.0103.251 SUBJECT:GRAVITY LOADS ® Roof 2 PROJECT:Suzanne Stauduhar Residence GRAVITY LOADS Roof Pitch: 6.0 :12 ROOF DEAD LOAD (D) Increase due to pitch Material weight [psf] Asphalt (Composite) Shingles 1.12 2.0 1/2" Plywood 1.12 1.0 Framing 1.00 3.0 Insulation 1.00 0.5 1/2" Gypsum Clg.1.12 2.0 M, E & Misc 1.00 6.5 Total Existing Roof DL PV Array DL 1.12 3 DL:1.12 ROOF LIVE LOAD (Lr) Existing Design Roof Live Load [psf]20 ASCE 7-16 Table 4.3-1 Roof Live Load With PV Array [psf]0 SNOW LOAD (S):w/ Solar Array Roof Slope [x:12]:6.0 Roof Slope [°]:27 Ground Snow Load, pg [psf]:50 ASCE 7-16, Section 7.2 Terrain Category:C ASCE 7-16, Table 7.3-1 Exposure of Roof:Fully Exposed ASCE 7-16, Table 7.3-1 Exposure Factor, Ce:0.9 ASCE 7-16, Table 7.3-1 Thermal Factor, Ct:1.1 ASCE 7-16, Table 7.3-2 Risk Category:II ASCE 7-16, Table 1.5-1 Importance Factor, Is:1.0 ASCE 7-16, Table 1.5-2 Flat Roof Snow Load, pf [psf]:35 ASCE 7-16, Equation 7.3-1 Minimum Roof Snow Load, pm [psf]:0 ASCE 7-16, Section 7.3.4 Unobstructed Slippery Surface?No ASCE 7-16, Section 7.4 Slope Factor Figure:Figure 7-2b ASCE 7-16, Section 7.4 Roof Slope Factor, Cs:1.00 ASCE 7-16, Figure 7.4-1 Sloped Roof Snow Load, ps [psf]:35 ASCE 7-16, Equation 7.4-1 Design Snow Load, S [psf]:35 1.00 35 Design material weight [psf] 2.2 1.1 3.0 0.5 2.2 6.5 15.6 3.4 #VALUE! 2020 MRC, Section R324.4.1.1 Existing 35 6.0 27 50 C Fully Exposed 0.9 1.1 II 1.0 35 0 No Figure 7-2b JOB NO.:U3594.0103.251 SUBJECT:LOAD COMPARISON ® Roof 2 PROJECT:Suzanne Stauduhar Residence Summary of Loads Existing With PV Array D [psf]16 19 Lr [psf]20 0 S [psf]35 35 Maximum Gravity Loads: Existing With PV Array (D + Lr) / Cd [psf]28 21 ASCE 7-16, Section 2.4.1 (D + S) / Cd [psf]44 47 ASCE 7-16, Section 2.4.1 Maximum Gravity Load [psf]:44 47 Maximum Member Forces: GEOMETRY Span(ft)27.0 (Approximate) Solar Panel Array Start, a (ft)6.0 (Approximate) Solar Panel Array Length, b (ft)5.5 (Approximate) Framing Spacing (ft)2.0 MEMBER FORCES Existing With PV Array Vertical Reaction, V1 (lbs)1180 1201 OK Vertical Reaction, V2 (lbs)1180 1190 OK Existing With PV Array Moment @ Center, M (lbs-ft)7962 8102 OK Ratio The gravity loads, and thus the stresses of the structural elements, in the area of the solar array are either decreased or increased by no more than 5%. Stress decreases or increases of no more than 5% are considered acceptable. Therefore, the structure is permitted to remain unaltered. (Cd = Load Duration Factor = 0.9 for D, 1.15 for S, and 1.25 for Lr) Ratio 102% 102% 101% a. THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING THE SPECIFIED RAIL SYSTEM. THE MOUNTING FEET ARE TO BE SPACED AS SHOWN IN THE DETAILS, AND MUST BE STAGGERED TO ADJACENT FRAMING MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD. b. UNLESS NOTED OTHERWISE, MOUNTING ANCHORS SHALL BE 516" LAG SCREWS WITH A MINIMUM OF 2 12" PENETRATION INTO ROOF FRAMING. c. THE PROPOSED PV SYSTEM ADDS 3.0 psf TO THE ROOF FRAMING SYSTEM. 1. ROOF LIVE LOAD = 35 psf TYPICAL, 0 psf UNDER NEW PV SYSTEM. 2. GROUND SNOW LOAD = 50 psf 3. WIND SPEED = 115 mph 4. EXPOSURE CATEGORY = CGENERAL STRUCTURAL NOTES:PHOTOVOLTAIC SYSTEM SPECIFICATIONS BUILDING: HENNEPIN COUNTY ZONING: HENNEPIN COUNTY UTILITY: WRIGHT HENNEPIN UTILITY METER #342674200AUTHORITIES HAVING JURISDICTIONSatellite ViewVicinity MapSheet NumberWOLF RIVER ELECTRIC101 ISANTI PARKWAY NE,SUITE G ISANTI, MN 55040ELECTRICAL LICENSE:EA777669Contact: (763) 229-6662contact@wolfriverelectric.comSheet NumberDESIGNED BY:WOLF RIVERELECTRICRevisions TableDescriptionDateRev.Sheet Name &Creation DateEngineer Signature & StampBuilding License :BC7732711.ALL COMPONENTS ARE UL LISTED AND CEC CERTIFIED, WHERE WARRANTED.2.THE SOLAR PV SYSTEM WILL BE INSTALLED IN ACCORDANCE WITH ARTICLE 690 OF THE NEC 20233.THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEM INSPECTED PRIOR TO PARALLEL OPERATION.4.ALL CONDUCTORS OF A CIRCUIT, INCLUDING THE EGC, MUST BE INSTALLED IN THE SAME RACEWAY, OR CABLE, OR OTHERWISE RUN WITH THE PV ARRAY CIRCUIT CONDUCTORS WHEN THEY LEAVE THE VICINITY OF THE PV ARRAY.5.WHERE METALLIC CONDUIT CONTAINING DC CONDUCTORS IS USED INSIDE THE BUILDING, IT SHALL BE IDENTIFIED AS "CAUTION: SOLAR CIRCUIT" EVERY 10FT.6.HEIGHT OF THE AC DISCONNECT SHALL NOT EXCEED 6'-7" PER NEC CODE 240.24.7.A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH CEC 690.47 AND 250.50 THROUGH 60 AND 250-166 SHALL BE PROVIDED. PER NEC GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED AND BONDED TO THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE OR INADEQUATE A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT. GROUND ROD WITH ACORN CLAMP. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN #8 AWG AND NO LARGER THAN #6 AWG COPPER AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM.8.PHOTOVOLTAIC MODULES ARE TO BE CONSIDERED NON-COMBUSTIBLE.9.PHOTOVOLTAIC INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING. MECHANICAL, OR BUILDING ROOF VENTS.10.ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH USE. WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF THE ROOF SURFACE.11.ALL SINAGE TO BE PLACED IN ACCORDANCE WITH THE LOCAL BUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT. ALL PLAQUES AND SINAGE WILL BE INSTALLED AS REQUIRED BY THE NEC AND AHJ.12.AS SPECIFIED BY THE AHJ, EQUIPMENT USED IN UNGROUNDED SYSTEMS LABELED ACCORDING TO NEC 690.35(F).13.INVERTER(S) USED IN UNGROUNDED SYSTEM SHALL BE LISTED FOR THIS USE [NEC 690.35(G)].14.THE INSTALLATION OF EQUIPMENT AND ALL ASSOCIATED WIRING AND INTERCONNECTION SHALL BE PERFORMED ONLY BY QUALIFIED PERSONS [NEC 690.4(C)]15.ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED (OR BETTER), INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND SWITCHES.16.ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH NEC ARTICLE 250.17.SYSTEM GROUNDING SHALL BE IN ACCORDANCE WITH NEC 690.41.18.PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION IN ACCORDANCE WITH NEC 690.1219.DISCONNECTING MEANS SHALL BE LOCATED IN A VISIBLE, READILY ACCESSIBLE LOCATION WITHIN THE PV SYSTEM EQUIPMENT OR A MAXIMUM OF 10 FEET AWAY FROM THE SYSTEM [NEC 690.13(A)]20.ALL WIRING METHODS SHALL BE IN ACCORDANCE WITH NEC 690.3121.WORK CLEARANCES AROUND ELECTRICAL EQUIPMENT WILL BE MAINTAINED PER NEC 110.26(A)(1), 110.26(A)(2) AND 110.26(A)(3).22.ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED & IDENTIFIED IN ACCORDANCE WITH UL170323.ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND ANCHOR CONDUIT RUNS AS REQUIRED PER NEC.GENERAL ELECTRIC NOTESDesigner SignatureSUZANNE STAUDUHAR4725 Bayside Rd,Orono, MN 55359SHEET INDEX SYSTEM SIZE: MODULE TYPE & AMOUNT: MODULE DIMENSIONS: INVERTER: INTERCONNECTION METHOD:COVERSHEET01/24/2025PV-0.0 ALL WORK SHALL CONFORM TO THEFOLLOWING CODESa. 2023 NATIONAL ELECTRICAL CODEb. 2020 MINNESOTA RESIDENTIAL CODEc. 2020 MINNESOTA BUILDING CODEd. 2024 MINNESOTA ENERGY CODEe. 2020 MINNESOTA ACCESSIBILITY CODEf. 2020 MINNESOTA MECHANICAL & FUEL GAS CODEg. 2020 MINNESOTA PLUMBING CODEh. 2020 MINNESOTA STATE FIRE CODEi ANY OTHER LOCAL AMENDMENTSGOVERNING CODESSUZANNE STAUDUHAR 4725 Bayside Rd Orono, MN 55359 AHJ: HENNEPIN COUNTY UTILITY: WRIGHT HENNEPIN UTILITY METER #342674200 18 SUNPOWER SPR-M415-H-AC (415W)(L/W/H) 73.7"/40.6"/1.57"18 ENPHASE IQ7HS-66-M-US (SPWR-A5)[1 PHASE, 240V]SUPPLY SIDE TAP18 Modules - Roof Mounted7.470 kW DC6.912 kW ACPV-0.0COVER SHEETPV-1.0PLOT & SITE PLANPV-1.1STRING ATTACHMENTPV-1.2EQUIPMENT ELEVATIOND-2.0ATTAHCMENT DETAILD-2.13-LINE SHEETD-2.2PLACARD SHEETD-2.3WARNING SHEETI hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota,Kelly G. Springer, License No. 60925,Expiration Date: 30-June-202601/31/2025VSE Project Number: U3594.0103.251Vector Structural Engineering has reviewed the existingstructure with loading from the solar array and screwconnections to the existing framing. The design of theracking system, racking connections, and all otherstructural is by others. Mechanical, architectural, and allother nonstructural aspects of the design are by others.Electrical is by others, unless stamped by Dean Levorsen. M EM TB ACCM EM TB ACCPARCEL: 0611723220022PROPERTY LINEDRIVEWAYSYSTEM LEGENDLOT:2.55 ACRESFENCE LINEROOF SECTIONSMODULE - 14SLOPE - 10.0°/12AZIMUTH - 181.10°MATERIAL - ASPHALT SHINGLETRUSS SIZE & SPACING - 2"X4" @ 24" O.C.SYSTEM LEGENDPANELS & INVERTERS= ROOF OBSTRUCTIONSAC= ATTIC RUN CONDUIT= ATTIC RUN CONDUIT JUNCTION BOXEXISTING UTILITYMETER #342674200MEXISTING MAIN SERVICE PANELCNEW ENPHASE COMBINER= FIRE PATHWAYNEW UTILITY AC DISCONNECTTBNEW TAP BOXPMNEW UTILITY EXPORT METERMODULE - 4SLOPE - 10.0°/12AZIMUTH - 245.15°MATERIAL - ASPHALT SHINGLETRUSS SIZE & SPACING - 2"X4" @ 24" O.C.Sheet NumberSheet NumberWOLF RIVER ELECTRIC101 ISANTI PARKWAY NE,SUITE G ISANTI, MN 55040ELECTRICAL LICENSE:EA777669Contact: (763) 229-6662contact@wolfriverelectric.comSheet NumberDESIGNED BY:WOLF RIVERELECTRICRevisions TableDescriptionDateRev.Sheet Name &Creation DateEngineer Signature & StampBuilding License :BC773271Designer SignaturePV-1.0NOTE :1. THIS DRAWING IS FOR ILLUSTRATIVE PURPOSES ONLY!2. ALL TESTING SHALL BE PERFORMED BY QUALIFIEDPERSONNEL, WITH PROPER PERSONAL PROTECTIVEEQUIPMENT.3. 24/ 7 UNESCORTED KEYLESS ACCESS IS TO BEPROVIDED FOR ALL UTILITY EQUIPMENT.4. AC DISCONNECT SHOULD BE LOCATED TOGETHER IN AREADILY ACCESSIBLE LOCATION WITHIN 10' OF THE MAINSERVICE METER ROOF ACCESS POINTROOF ACCESS POINTS SHALL BE LOCATED IN AREAS THAT DO NOTREQUIRETHE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH ASWINDOWSOR DOORS, AND LOCATED AT STRONG POINTS OF BUILDINGCONSTRUCTIONIN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICTWITHOVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES AND ORSIGNSNOTE:ATTIC RUN CONDUIT SHALL BE MINIMUM 18INCHES FROM ROOF SHEATING1SITE PLAN & PLOT PLANPV 1.0ROOF #01ROOF #02PLOT & SITEPLAN01/24/2025NSUZANNE STAUDUHAR 4725 Bayside Rd Orono, MN 55359 AHJ: HENNEPIN COUNTY UTILITY: WRIGHT HENNEPIN UTILITY METER #342674200198'-0"411'-0"670'-0"40'-0"200'-0"75'-0"PROPERTY LINEDECKCONCRETEDRIVEWAY(PAVEMENT)NEW ENPHASECOMBINERNEW UTILITY ACDISCONNECTNEW TAP BOXNEW UTILITY EXPORTMETEREXISTING UTILITYMETER #200016038EXISTING MAIN SERVICEPANELROOF ACCESSPOINT18 SUNPOWER SPR-M415-H-AC (415W)(L/W/H) 73.7"/40.6"/1.57"18 ENPHASE IQ7HS-66-M-US (SPWR-A5)[1 PHASE, 240V]83'-0"42'-0"382'-0"SCALE: NTS (NOT TO SCALE)36" FIRE PATHWAY36" FIRE PATHWAY3 6 " F I R E P A T HW A Y 3 6 " F I R E P A T HW A Y 36" FIRE PATHWAY36" FIRE PATHWAY36" FIRE PATHWAY36" FIRE PATHWAYROOF OBSTRUCTIONROOF #01ROOF #02BAYSIDE ROADROOF ACCESSPOINTDRIVEWAY(PAVEMENT) M EM TB ACCSheet NumberSheet NumberWOLF RIVER ELECTRIC101 ISANTI PARKWAY NE,SUITE G ISANTI, MN 55040ELECTRICAL LICENSE:EA777669Contact: (763) 229-6662contact@wolfriverelectric.comSheet NumberDESIGNED BY:WOLF RIVERELECTRICRevisions TableDescriptionDateRev.Sheet Name &Creation DateEngineer Signature & StampBuilding License :BC773271Designer SignaturePV-1.1SCALE: NTS (NOT TO SCALE)ATTACHMENT AND STRING LAYOUTPV 1.1NOTE: THE MAXIMUM CANTILEVER OF THE RAILSHALL BE 1/3 OF THE ATTACHMENT SPACING.1ARRAY AREAMODULE AREAMODULE DIM (75.74 X 40.87)21.5 SQ. FT.AREA OF ARRAY367.22 SQ. FT.ROOF AREA3482.70 SQ. FT.ROOF COVERAGE %ROOF AREA/ARRAY AREA10.54%NSYSTEM LEGEND= ATTACHMENT POINTS(43 Nos)= TRUSS# MODULE - 9CIRCUIT #01# MODULE - 9CIRCUIT #02CIRCUIT(S)= RAIL SYSTEMSTRINGATTACHMENT01/24/2025B.O.M. BILL OF MATERIALSCATEGORYQTY.1181816626202120FEET48TERM CAPS4SEALING CAPS4CABLE SPLICES4311321140A FUSE 250VSURGE PROTECTORS60A AC DISCONNECT NEMA3 1P, 3W 120/240VGROUNDING RODS J-BOXSPR-M415-H-ACIQ7HS MICROINVERTER TRUNK CABLESEATON BR 20A 2-POLE BREAKERCONSUMPTIONMIDSENDSINVISIMOUNTENPHASE COMBINER200A (METER SOCKET) (MN) (U4801XL5T9)IT350 SPLICESCOMPONENTWEIGHTQTYTOTALWEIGHTMODULES (PER PIECE)48.50 lbs18873.00 lbsINVERTERS (PER PIECE)2.40 lbs1843.20 lbsSOLAR FOOT (PER PIECE)1.00 lbs4343.00 lbsINVISIMOUNT (PER LINEAL FOOT)6.00 lbs1696.00 lbsMIDS (PER PIECE)0.14 lbs263.64 lbsENDS (PER PIECE)0.24 lbs204.80 lbsSPLICES (PER PIECE)0.60 lbs63.60 lbsCOMPONENTS TOTAL WEIGHT 1067.24 lbsSUZANNE STAUDUHAR 4725 Bayside Rd Orono, MN 55359 AHJ: HENNEPIN COUNTY UTILITY: WRIGHT HENNEPIN UTILITY METER #342674200I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota,Kelly G. Springer, License No. 60925,Expiration Date: 30-June-202601/31/2025VSE Project Number: U3594.0103.251Vector Structural Engineering has reviewed the existingstructure with loading from the solar array and screwconnections to the existing framing. The design of theracking system, racking connections, and all otherstructural is by others. Mechanical, architectural, and allother nonstructural aspects of the design are by others.Electrical is by others, unless stamped by Dean Levorsen. SCALE: NTS1EQUIPMENT ELEVATIONPV 1.2INTERIOR WALLEXTERIOR WALLSheet NumberSheet NumberWOLF RIVER ELECTRIC101 ISANTI PARKWAY NE,SUITE G ISANTI, MN 55040ELECTRICAL LICENSE:EA777669Contact: (763) 229-6662contact@wolfriverelectric.comSheet NumberDESIGNED BY:WOLF RIVERELECTRICRevisions TableDescriptionDateRev.Sheet Name &Creation DateEngineer Signature & StampBuilding License :BC773271Designer SignaturePV-1.2EQUIPMENTELEVATION01/24/2025SUZANNE STAUDUHAR 4725 Bayside Rd Orono, MN 55359 AHJ: HENNEPIN COUNTY UTILITY: WRIGHT HENNEPIN UTILITY METER #342674200 EXISTING MAINSERVICE PANELEXTERIOR WALLNEW ENPHASECOMBINERENPHASENEW UTILITYEXPORT METERNEW PVCTAP BOXEXISTING UTILITYMETER#342674200NEW UTILITYAC DISCONNECTEND OF WALL4'<10'3'MAINTAIN 3' WORKINGCLEARANCEWINDOW Sheet NumberWOLF RIVER ELECTRIC101 ISANTI PARKWAY NE,SUITE G ISANTI, MN 55040ELECTRICAL LICENSE:EA777669Contact: (763) 229-6662contact@wolfriverelectric.comSheet NumberDESIGNED BY:WOLF RIVERELECTRICRevisions TableDescriptionDateRev.Sheet Name &Creation DateEngineer Signature & StampBuilding License :BC773271Designer SignatureD-2.0PLACARDSHEET01/24/20251ATTACHMENT DETAILD-2.0SCALE: NTSPV MODULES2"X4" TRUSS @ 24" OCMAXIMUM HEIGHT 6" FROM TOPOF THE ROOF TO TOP OF PANELSEE (2/S1.0) FORENLARGED VIEWPV MODULETOP BOLTGROUNDING & END/MID CLAMP2"X4" TRUSS @ 24" OC(E) COMP SHINGLE ROOF(E) COMP SHINGLE ROOF(1) 5/16" SS LAG BOLT WITH MIN 2 12"THREAD EMBEDMENT, SEALEDPENETRATION INTO TRUSS.SUNPOWER INVISIMOUNT RAILINSTAFLASH-FOOTSCALE: NTS2ATTACHMENT DETAIL (ENLARGED VIEWD-2.0THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING .(THE PEGASUS COMP MOUNT & SUNPOWER INVISIMOUNT RAIL SYSTEM), ANDMUST BE STAGGERED TO ADJACENT FRAMING MEMBERS TO SPREAD OUT THEADDITIONAL LOAD.B. UNLESS NOTED OTHERWISE, MOUNTING ANCHORS SHALL BE 516" LAGSCREWS WITH A MINIMUM OF 2 12" PENETRATION INTO ROOF FRAMINGC. THE PROPOSED PV SYSTEM ADDS 3.0 psf TO THE ROOF FRAMING SYSTEM1. ROOF LIVE LOAD = 35 psf TYPICAL, 0 psf UNDER NEW PV SYSTEM.2. GROUND SNOW LOAD = 50 psf3. WIND SPEED = 115 mphEXPOSURE CATEGORY = CGENERAL STRUCTURAL NOTESSUZANNE STAUDUHAR 4725 Bayside Rd Orono, MN 55359 AHJ: HENNEPIN COUNTY UTILITY: WRIGHT HENNEPIN UTILITY METER #342674200I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota,Kelly G. Springer, License No. 60925,Expiration Date: 30-June-202601/31/2025VSE Project Number: U3594.0103.251Vector Structural Engineering has reviewed the existingstructure with loading from the solar array and screwconnections to the existing framing. The design of theracking system, racking connections, and all otherstructural is by others. Mechanical, architectural, and allother nonstructural aspects of the design are by others.Electrical is by others, unless stamped by Dean Levorsen. Sheet NumberWOLF RIVER ELECTRIC101 ISANTI PARKWAY NE,SUITE G ISANTI, MN 55040ELECTRICAL LICENSE:EA777669Contact: (763) 229-6662contact@wolfriverelectric.comSheet NumberDESIGNED BY:WOLF RIVERELECTRICRevisions TableDescriptionDateRev.Sheet Name &Creation DateEngineer Signature & StampBuilding License :BC773271Designer SignatureD-2.13-LINESHEET01/24/2025AHJ: HENNEPIN COUNTYUTILITY: WRIGHT HENNEPINNOTE: AC DISCONNECT TO BE INSTALLEDWITHIN 10FT FROM UTILITY METER.Photovoltaic SystemDC SYSTEM SIZE7.470 kWAC SYSTEM SIZE6.912 kWTOTAL MODULE COUNT18NOTES :1. THIS DRAWING IS FOR ILLUSTRATIVE PURPOSES ONLY!2. ALL TESTING SHALL BE PERFORMED BY QUALIFIED PERSONNEL, WITH PROPER PERSONAL PROTECTIVE EQUIPMENT.3. 24/ 7 UNESCORTED KEYLESS ACCESS IS TO BE PROVIDED FORALL UTILITY EQUIPMENT.4. THE PRODUCTION METER & AC DISCONNECT SHOULD BE LOCATED TOGETHER VISIBLE-OPEN LOCKABLE READILY ACCESSIBLE LOCATIONWITHIN 10’ OF THE MAIN SERVICE METER.5. THE METER SOCKET FOR THE PV PRODUCTION METER SHALL BE MARKED WITH A STAMPED BRASS, ALUMINUM, OR STAINLESS STEEL TAG,INDICATING THE ADDRESS INCLUDING THE UNIT, TYPICALLY “PV PROD” IN ACCORDANCE WITH THE REQUIREMENTS FOR “METERIDENTIFICATION” IN SECTION 4.14.4 OF THE XCEL ENERGY STANDARD, OR AS MAY BE AMENDED.6. THE PV PRODUCTION METER SHALL BE LOCATED WITHIN TEN (10) FEET OF THE EXISTING UTILITY METER. IF THERE IS ANY REASON THISCANNOT BE ACCOMPLISHED, THE APPROVAL OF THE PROPOSED PV PRODUCTION METERING WILL NEED TO BE OBTAINED BY THE LOCALELECTRIC METER SHOP.INVERTER SPECIFICATIONS 1- PHASEMANUFACTURERENPHASE IQ7HS-66-M-USMAX DC VOLT RATING59 VOLTSMAX POWER AT 40 C384 WATTSNOMINAL AC VOLTAGE240 VOLTSMAX AC CURRENT1.60AMPSMAX OCPD RATING20 AMPSMAX. PANEL/CIRCUIT10SHORT CIRCUIT CURRENT15 AMPSPV MODULE RATING @ STCMANUFACTURERSUNPOWERSPR-M425-H-AC-415OUTPUT POWER415WPOWER TOLERANCE+5/-0%MODULE EFFICIENCY22.00%TEMP. COEF. (POWER)-0.29% / °CSUZANNE STAUDUHAR 4725 Bayside Rd Orono, MN 55359 AHJ: HENNEPIN COUNTY UTILITY: WRIGHT HENNEPIN UTILITY METER #342674200 L1L2NGL2L2L1L1L2L2L1L1GNSURGE PROTECTIONDEVICE MNSPD-300-AC20A20A20ANEW ENPHASE COMBINER 4MONITORING DEVICE 240V, NEMA 3R 1PHASEEXISITING UTILITY METER1-PHASE, 3W 120V/240V234NEW UTILITY ACDISCONNECT SWITCHSQUARE D 240V/60AFUSED NEMA3R D222NRBREFERENCE POINTOF APPLICABILITYVISIBLE-OPEN LOCKABLEREADILY ACCESSIBLEEXISTING 240V/200ABUSBAR RATING, SERVICEPANEL SINGLE PHASEWITH 100A DISCONNECTEXISTING GROUNDINGELECTRODE SYSTEMNEW JUNCTION BOX600V,NEMA 4 UL LISTED1POINT OF INTERCONNECTIONSUPPLY SIDE TAP(IT350 POLARIS LUGS)NEW GROUNDINGELECTRODE SYSTEM200AMMNEW PVCTAP BOXNEW UTILITY EXPORTMETER MILBANK U4801-XL-TG-KK 1-PHASE3-WIRE 120/240V#6 AWG COPPERGROUND<10'5IQ GATEWAYCONSUMPTION CTPORDUCTION CT40AFUSES18 SUNPOWER SPR-M415-H-AC (415W)(L/W/H) 73.7"/40.6"/1.57"18 ENPHASE IQ7HS-66-M-US. INVERTERS TO BE MOUNTED ON THERAIL BENEATH EACH OF THE PANELSCONDUCTOR SCHEDULESPECIFIED CONDUCTORS SHALL BE COPPER UNLESS OTHERWISE SPECIFIEDTAG #DESCRIPTIONWIRE GAUGE# OF CONDUCTORS/COLORCONDUIT TYPECONDUIT SIZE1INVERTER OUTPUT (TRUNK CABLE)12 AWG6(3L1, 3L2)FREE AIRN/AEGC(BARE COPPER GROUND6 AWG1 BARE2INVERTER OUTPUT (THWN-2)12 AWG6(3L1, 3L2)FMC3/4"EGC(THWN-2)12 AWG1(GRN)3INVERTER OUTPUT(THWN)6 AWG3(L1,L2,N) B/R/WSCH 80 PVC1"EGC(THWN)10 AWG1(GRN)4INVERTER OUTPUT(THWN)6 AWG3(L1,L2,N) B/R/WSCH 80 PVC1"5INVERTER OUTPUT(THWN)4/0 AWG AL3(L1,L2,N) B/R/WSCH 80 PVC2"INVERTER ENPHASEIQ7HS9 MICRO-INVERTERS IN BRANCH CIRCUIT #19 MICRO-INVERTERS IN BRANCH CIRCUIT #2TERMINATOR CAP ON THELAST CABLE CONNERTOR (TYP)GN Sheet NumberWOLF RIVER ELECTRIC101 ISANTI PARKWAY NE,SUITE G ISANTI, MN 55040ELECTRICAL LICENSE:EA777669Contact: (763) 229-6662contact@wolfriverelectric.comSheet NumberDESIGNED BY:WOLF RIVERELECTRICRevisions TableDescriptionDateRev.Sheet Name &Creation DateEngineer Signature & StampBuilding License :BC773271Designer SignatureD-2.2Serviced by Wolf River ElectricContact: (763) 229-6662NPLACARDSHEET01/24/2025CAUTION ! MULTIPLE SOURCES OF POWERPOWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITHDISCONNECTS LOCATED AS SHOWNFOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN MAINSERVICE PANEL UTILITY METERUTILITY ACDISCONNECTUTILITY EXPORTMETERBAYSIDE ROADSUZANNE STAUDUHAR 4725 Bayside Rd Orono, MN 55359 AHJ: HENNEPIN COUNTY UTILITY: WRIGHT HENNEPIN UTILITY METER #342674200 LABEL LOCATION: RSD INITIATION DEVICE, AC DISCONNECTPER CODE: NEC 690.56(C)(2)ELECTRICAL SHOCK HAZARDWARNINGLABEL LOCATION: COMBINER PANEL, ACDISCONNECT, POINT OF INTERCONNECTIONPER CODE: NEC 706.15(C)(4), NEC 690.13(B)LABEL LOCATION: MAIN SERVICE DISCONNECT, UTILITY METERPER CODE: NEC 690.13(B)LABEL LOCATION: COMBINER PANEL(S), MAIN SERVICE DISCONNECTPER CODE: NEC 110.27(C), OSHA 1910.145(f)(7)LABEL LOCATION: AC DISCONNECTPER CODE: NEC 690.13(B)LABEL LOCATION: MAIN SERVICE DISCONNECTPER CODE: NEC 690.56(C)!LABEL LOCATION: DC CONDUIT/RACEWAYSPER CODE: NEC 690.31(D)(2)LABEL LOCATION: AC DISCONNECT/POINT OF INTERCONNECTIONPER CODE: NEC 690.54DO NOT DISCONNECTUNDER LOADLABEL LOCATION: MAIN SERVICE DISCONNECTPER CODE: NEC 690.15(B) & NEC 690.33(D)(2)DUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEMWARNINGLABEL LOCATION: MAIN SERVICE DISCONNECT, PRODUCTION/NET METERPER CODE: NEC 690.59, 705.12(C)!PHOTOVOLTAICAC DISCONNECTPHOTOVOLTAIC SYSTEM AC DISCONNECTRATED AC OUPUT CURRENT: 28.8 ANOMINAL OPERATING AC VOLTAGE: 240 VSOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNSOLAR ELECTRICPV PANELSTURN RAPID SHUTDOWNSWITCH TO THE"OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCESHOCK HAZARDIN THE ARRAYMAIN PHOTOVOLTAICSYSTEM DISCONNECTRAPID SHUTDOWN FORSOLAR PV SYSTEMTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONTURN OFF PHOTOVOLTAIC ACDISCONNECT IOR TOWORKING INSIDE PANELWARNING!PHOTOVOLTAIC POWER SOURCEWARNINGSHEETUTILITYSheet NumberWOLF RIVER ELECTRIC101 ISANTI PARKWAY NE,SUITE G ISANTI, MN 55040ELECTRICAL LICENSE:EA777669Contact: (763) 229-6662contact@wolfriverelectric.comSheet NumberDESIGNED BY:WOLF RIVERELECTRICRevisions TableDescriptionDateRev.Sheet Name &Creation DateEngineer Signature & StampBuilding License :BC773271Designer SignatureD-2.3D-2.3D-2.301/24/2025SUZANNE STAUDUHAR 4725 Bayside Rd Orono, MN 55359 AHJ: HENNEPIN COUNTY UTILITY: WRIGHT HENNEPIN UTILITY METER #342674200 Model No. MNSPD-115 MNSPD-300-AC MNSPD-300-DC MNSPD-600 Max Operating Voltage 100 VAC/150VDC 300VAC 385VDC 480VAC/600VDC Surge Current per Phase 80kA 80kA 80kA 80kA Configuration 1 O, 3-wire (2 Legs) 1 O, 3-wire (2 Legs) 1 O, 3-wire (2 Legs) 1 O, 3-wire (2 Legs) MCOV 180V L-N 470V L-N 470V L-N 780V L-N SCCR 10kA 10kA 10kA 10kA VPR 600V/3kA L_G 600V 1200V 1200V 1800V O3.527” 4.425”3.82” 24” Wires O 2” ires Performance Surge Current Rating per Phase 80kA Short Circuit Current Rating 10kA Fusing Individually fused MOVs Thermal Fusing Yes Over current Fusing Yes Operating Frequency 0 to 500 Hz Mechanical Description Enclosure Polycarbonate UL94V-0 Environmental Rating Type 4X Connection Method #12 AWG Weight 1 lb. Mounting Method 1/2” Conduit Knockout Operating Altitude Sea Level – 12,000’ (3,658 Meters) Storage Temp -40o F to +185o F (-40o C to +85o C) Operating Temp -40o F to +185o F (-40o C to +85o C) Diagnostics Blue status LED, one per leg Listings and Performance UL Standard for Safety, UL 1449 Surge Protective Devices-Fourth Edition CSA C22.2 No. 8-M1986 Electromangetic Interference (EMI) Filters, Fourth Edition Diagnostic Blue LED Thermal Disconnector Internal Fuse Response Time <1 micro sec. MNSPD-115 0 to 90 VAC 0 to 115 VDC 180V 600V Up to 90VAC circuits, 12V, 24V, 48VDC battery circuits UL1449 4th Ed. Type 1 MNSPD-300-AC 0 to 250 VAC 470V 1200V 120/240 VAC circuits UL1449 4th Ed. Type 1 MNSPD-300-DC 0 to 300 VDC 470V 1200V Off-grid PV combiners Charge controller inputs up to 300VDC UL1449 4th Ed. Type 1 MNSPD-600 0 to 480 VAC 0 to 600 VDC 780V 1800V 316V/480 VAC circuits Grid-tie PV combiners Grid-tie inverter input Non-Isolated Inverters UL1449 4th Ed. Type 1 PART NUMBER Nominal Voltage MCOV VPR Line to Ground Suggested Placement Type MNSPD-300-AC LED indicates when voltage is present between L1 + ground and L2 + ground MNSPD-115, MNSPD-300-DC and MNSPD-600: LED indicates when voltage is present between L1 + L2 (PV+ PV-) www.midnitesolar.com/spd 19115 - 62nd Ave NE, Arlington, WA 98223 PH. 360-403-7207 FAX 360-691-6862 MidNite Surge Protection DevicesMidNite Surge Protec tion Devices 425-410 W Residential Black AC Module SunPower® Maxeon® Technology Built specifically for use with the SunPower Equinox® system, the only fully integrated solution designed, engineered, and warranted by one company. Highest Power Density Available The patented, solid-copper foundation Maxeon Gen 6 cell is over 5% larger than prior generations, delivering the highest-efficiency all-black AC solar module available.1 Highest Lifetime Energy and Savings Designed to deliver 60% more energy over 25 years in real-world conditions like partial shade and high temperatures.2 Best Reliability, Best Warranty With more than 42.6 million and 15 GW of modules deployed around the world, SunPower technology is proven to last. That’s why we stand behind our module and microinverter with the industry’s best 25-year Combined Power and Product Warranty, including the highest Power Warranty in solar. Datasheet 0510 15 20 25 150% 140% 130% 120% 110% 100% 90% 80% 70% 60%25-year Energy Yield per WattYears of Operation Up to 60% More Lifetime Energy Conventional Panel M-Series Part of the SunPower Equinox® Solar System • Seamless aesthetics • Compatible with mySunPower monitoring Factory-integrated Microinverter • Highest-power integrated AC module in solar • Engineered and calibrated by SunPower for SunPower AC modules 6.37 in[161.7 mm]6.54 in[166 mm]5% larger need blk image 1 Based on datasheet review of websites of top 20 manufacturers per IHS, as of July 2021. 2 Maxeon 435 W, 22.5% efficient, compared to a Conventional Panel on same-sized arrays (300 W, 19% efficient, approx. 1.6 m²), 7.9% more energy per watt (based on PVSyst pan files for avg. US climate), 0.5%/yr slower degradation rate (Jordan, et. al. “Robust PV Degradation Methodology and Application.”PVSC 2018). 3 Based on search of datasheet values from websites of top 10 manufacturers per IHS, as of June 2021. 4 Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. 5 Factory set to IEEE 1547a-2014 default settings. CA Rule 21 default settings profile set during commissioning. 6 Standard Test Conditions (1000 W/m² irradiance, AM 1.5, 25°C). All DC voltage is fully contained within the module. 7 UL Listed as PVRSE and conforms with NEC 2014 and NEC 2017 690.12; and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors; when installed according to manufacturer’s instructions. 8 Please read the safety and installation instructions for more information regarding load ratings and mounting configurations. See www.sunpower.com/company for more reference information. For more details, see extended datasheet: www.sunpower.com/solar-resources. Specifications included in this datasheet are subject to change without notice. ©2022 SunPower Corporation. All rights reserved. SUNPOWER, the SUNPOWER logo and EQUINOX are registered trademarks of SunPower Corporation in the U.S. MAXEON is a registered trademark of Maxeon Solar Technologies, Ltd. For more information visit www.maxeon.com/legal. AC Electrical Data Inverter Model: Type H (Enphase IQ7HS)@240 VAC @208 VAC Max. Continuous Output Power (VA)384 369 Nom. (L–L) Voltage/Range3 (V)240 / 211–264 208 / 183–229 Max. Continuous Output Current (A)1.60 1.77 Max. Units per 20 A (L–L) Branch Circuit4 10 9 CEC Weighted Efficiency 97.0%96.5% Nom. Frequency 60 Hz 60 Hz Extended Frequency Range 47–68 Hz 47–68 Hz AC Short Circuit Fault Current Over 3 Cycles 4.82 A 4.82 A Overvoltage Class AC Port III III AC Port Backfeed Current 18 mA 18 mA Power Factor Setting 1.0 1.0 Power Factor (adjustable)0.85 (inductive) / 0.85 (capacitive)0.85 (inductive) / 0.85 (capacitive) DC Power Data SPR-M425-BLK-H-AC SPR-M415-BLK-H-AC SPR-M410-BLK-H-AC Nom. Power⁶ (Pnom) W 425 415 410 Power Tolerance +5/−0%+5/−0%+5/−0% Module Efficiency 22.0%21.5%21.2% Temp. Coef. (Power)−0.29% / °C −0.29% / °C −0.29% / °C Shade Tolerance Integrated module-level max. power point tracking Tested Operating Conditions Operating Temp.−40° F to +185° F (−40° C to +85° C) Max. Ambient Temp.122° F (50° C) Max. Test Load⁸Wind: 125 psf, 6000 Pa, 611 kg/m² back Snow: 187 psf, 9000 Pa, 917 kg/m² front Max. Design Load Wind: 75 psf, 3600 Pa, 367 kg/m² back Snow: 125 psf, 5400 Pa, 550 kg/m² front Impact Resistance 1 inch (25 mm) diameter hail at 52 mph (23 m/s) Mechanical Data Solar Cells 66 Maxeon Gen 6 Front Glass High-transmission tempered glass with anti-reflective coating Environmental Rating Outdoor rated Frame Class 1 black anodized (highest AAMA rating) Weight 48 lbs (21.8 kg) Recommended Max. Module Spacing 1.3 in. (33 mm) Warranties, Certifications, and Compliance Warranties • 25-year limited power warranty • 25-year limited product warranty Certifications and Compliance • UL 1741 / IEEE-1547 • UL 1741 AC Module • UL 61730 (Type 2 fire rated) • UL 62109-1 / IEC 62109-2 • FCC Part 15 Class B • ICES-0003 Class B • CAN/CSA-C22.2 NO. 107.1-01 • CA Rule 21 (UL 1741 SA)⁵ (includes Volt/Var and Reactive Power Priority) • UL Listed PV Rapid Shutdown Equipment⁷ Enables installation in accordance with: • NEC 690.6 (AC module) • NEC 690.12 Rapid Shutdown (inside and outside the array) • NEC 690.15 AC Connectors, 690.33(A)–(E)(1) When used with AC module Q Cables and accessories (UL 6703 and UL 2238)⁷ • Rated for load break disconnect PID Test 1000 V: IEC 62804 Packaging Configuration Modules per pallet 25 Packaging box dimensions 75.4 × 42.2 × 48.0 in. (1915 × 1072 × 1220 mm) Pallet gross weight 1300 lb (590 kg) Pallets per container 32 Net weight per container 18,880 kg M425-BLK | M415-BLK | M410-BLK SunPower Residential Black AC Module 1-800-SUNPOWER | sunpower.com 544400 RevA January 2022 Please read the safety and installation instructions for details. © 2024 Enphase Energy. All rights reserved. Enphase, the e and CC logos, IQ, and certain other marks listed at enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the U.S. and other countries. Data subject to change.DSH-00562-1.0-EN-US-2024-08-02 IQ7HS Microinverter The high-powered, smart grid-ready IQ7HS Microinverter with integrated MC4 connectors dramatically simplifies installation while achieving the highest system efficiency. Easy to install • Lightweight and simple • Faster installation with improved, lighter two-wire cabling • Built-in rapid shutdown compliant (NEC 2014 , 2017, 2020, and 2023) Productive and reliable • Optimized for high powered 60-cell/120-half-cut-cell, 66-cell/ 132-half-cut-cell, and 72-cell/ 144-half-cut-cell PV modules • More than a million hours of testing • Class II double-insulated enclosure • UL Listed Smart grid-ready • Complies with advanced grid support, voltage, and frequency ride-through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) and IEEE 1547:2018 (UL 1741-SB, 3rd Ed.) for single-phase systems Part of the Enphase Energy System, the IQ7HS Microinverters integrate with the IQ Gateway, IQ Battery, and the Enphase Installer App monitoring and analysis software. IQ7HS Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power- on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Connect PV modules quickly and easily to the IQ7HS Microinverters that have integrated MC4 connectors. IQ7HS Microinverters are UL Listed as PV rapid shutdown equipment and conform with various regulations when installed according to the manufacturer’s instructions. DATA SHEET DSH-00562-1.0-EN-US-2024-08-02 1 Pairing PV modules with wattage above the limit may result in additional clipping losses. See the compatibility calculator at enphase.com/installers/microinverters/calculator. 2 Nominal voltage range can be extended beyond nominal if required by the utility. 3 Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. IQ7HS Microinverter INPUT DATA (DC)UNITS IQ7HS-66-M-US Commonly used module pairings1 W 320–460 Module compatibility —60-cell/120-half-cut-cell, 66-cell/132-half-cut-cell, and 72-cell/144-half-cut-cell PV modules Maximum input DC voltage V 59 Peak power tracking voltage V 38–43 Operating range V 20–59 Minimum/Maximum start voltage V 30/59 Maximum input DC short-circuit current A 25 Maximum module Isc A 20 Overvoltage class DC port —II DC port back-feed current A 0 PV array configuration —1 × 1 ungrounded array; no additional DC side protection required; AC side protection requires max. 20 A per branch circuit OUTPUT DATA (AC) Peak output power VA 384 @ 240 VAC, 369 @ 208 VAC Maximum continuous output power VA 384 @ 240 VAC, 369 @ 208 VAC Nominal (L-L) voltage/Range2 V 240/211–264, 208/183–229 Maximum continuous output current —1.60 A (240 V), 1.77 A (208 V) Nominal frequency Hz 60 Extended frequency range Hz 47–68 AC short-circuit fault current over three cycles Arms 4.82 Maximum units per 20 A (L-L) branch circuit3 —10 (240 VAC), 9 (208 VAC) Overvoltage class AC port —III AC port back-feed current mA 18 Power factor setting —1.0 Power factor (adjustable)—0.85 leading ... 0.85 lagging EFFICIENCY CEC weighted efficiency %97.0 @ 240 V, 96.5 @ 208 V MECHANICAL DATA Ambient temperature range °C (°F)–40 to 60 (–40 to 140) Relative humidity range %4 to 100 (condensing) DC connector type —Stäubli MC4 Dimensions (H × W × D)mm (in)212 (8.3) × 175 (6.9) × 30.2 (1.2) without bracket Weight kg (lb)1.1 (2.4) Cooling —Natural convection—no fans Approved for wet locations —Yes Pollution degree —PD3 DSH-00562-1.0-EN-US-2024-08-02 FEATURES Communication Power line communication (PLC) Monitoring Enphase Installer App and monitoring options Compatible with IQ Gateway Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect means required by NEC 690 and C22.1-2018 Rule 64-220. Compliance CA Rule 21 (UL 1741-SA), IEEE 1547:2018 (UL 1741-SB 3rd Ed.) for single-phase systems HEI Rule 14H SRD 2.0 UL 62109-1, FCC Part 15 Class B, ICES-0003 Class B CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 rapid shutdown of PV systems for AC and DC conductors, when installed according to manufacturer’s instructions. MECHANICAL DATA Enclosure —Class II double-insulated, corrosion-resistant polymeric enclosure Environmental category/UV exposure rating —NEMA type 6/Outdoor DSH-00562-1.0-EN-US-2024-08-02 Revision history REVISION DATE DESCRIPTION DSH-00562-1.0 August 2024 Initial release. © 2024 Enphase Energy. All rights reserved. Enphase, the e and CC logos, IQ, and certain other marks listed at enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the U.S. and other countries. Data subject to change. IQC-4-4C-DSH-00217-3.0-EN-US-2024-08-16 DATA SHEET IQ Combiner 4/4C The Enphase IQ Combiner 4/4C with IQ Gateway and integrated LTE-M1 cell modem (included only with IQ Combiner 4C) consolidates interconnection equipment into a single enclosure and streamlines IQ Microinverters and storage installations by providing a consistent, pre-wired solution for residential applications. It offers up to four 2-pole input circuits and an Eaton BR series busbar assembly. Smart • Includes IQ Gateway for communication and control • Includes Enphase Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05), included only with IQ Combiner 4C • Includes solar shield to match IQ Battery aesthetics and deflect heat • Flexible networking supports Wi-Fi, Ethernet, or cellular • Optional AC receptacle available for PLC bridge • Provides production metering and consumption monitoring Simple • Centered mounting brackets support single stud mounting • Supports bottom, back and side conduit entry • Up to four 2-pole branch circuits for 240 VAC plug-in breakers (not included) • 80 A total PV or storage branch circuits Reliable • Durable NRTL-certified NEMA type 3R enclosure • Five-year limited warranty • Two-years labor reimbursement program coverage included for both the IQ Combiner SKU’s • UL Listed • X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C comply with IEEE 1547:2018 (UL 1741-SB, 3rd Ed.) © 2024 Enphase Energy. All rights reserved. Enphase, the e and CC logos, IQ, and certain other marks listed at https://enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the U.S. and other countries. Data subject to change. X-IQ-AM1-240-4 X2-IQ-AM1-240-4 (IEEE 1547:2018) X-IQ-AM1-240-4C X2-IQ-AM1-240-4C (IEEE 1547:2018) *Refer to the https://enphase.com/installers/resources/warranty page for country-specific warranty information. IQ Series Microinverters The high-powered smart grid-ready IQ Series Microinverters (IQ6, IQ7, and IQ8 Series) dramatically simplify the installation process. IQ System Controller 2 Provides microgrid interconnection device (MID) functionality by automatically detecting grid failures and seamlessly transitioning the home energy system from grid power to backup power. IQ Load Controller Helps prioritize essential appliances during a grid outage to optimize energy consumption and prolong battery life. IQ Battery All-in-one AC coupled storage system that is reliable, smart, simple, and safe. It provides backup capability, and installers can quickly design the right system size to meet the needs of both new and retrofit solar customers. 5-year limited warranty IQC-4-4C-DSH-00217-3.0-EN-US-2024-08-16 IQ Combiner 4/4C MODEL NUMBER UNITS DESCRIPTION IQ Combiner 4 (X-IQ-AM1-240-4, X2-IQ-AM1-240-4) — IQ Combiner 4 with an IQ Gateway printed circuit board for integrated revenue-grade PV production metering (ANSI C12.20 ±0.5%) and consumption monitoring (±2.5%). Includes a silver solar shield to match the IQ Battery and IQ System Controller 2 and to deflect heat. IQ Combiner 4C (X-IQ-AM1-240-4C, X2-IQ-AM1-240-4C)— IQ Combiner 4C with an IQ Gateway printed circuit board for integrated revenue-grade PV production metering (ANSI C12.20 ±0.5%) and consumption monitoring (±2.5%). Includes Enphase Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05), a plug-and-play industrial-grade cell modem for systems up to 60 microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, where there is adequate cellular service in the installation area). Includes a silver solar shield to match the IQ Battery and IQ System Controller 2 and to deflect heat. WHAT’S IN THE BOX UNITS IQ Gateway printed circuit board —IQ Gateway is the platform for total energy management for comprehensive, remote maintenance, and management of the Enphase Energy System. Busbar —80 A busbar with support for one IQ Gateway breaker and four 20 A breakers for installing IQ Series Microinverters and IQ Battery IQ Gateway breaker A Circuit breaker, 2-pole, 10/15 Production CT —Pre-wired revenue-grade solid-core CT, accurate up to ±0.5% Consumption CT —Two consumption metering split core or clamp-type CTs, shipped with the box, accurate up to ±2.5% Emphase Mobile Connect (only with IQ Combiner 4C)—4G-based LTE-M1 cellular modem (CELLMODEM-M1-06-SP-05) with a five-year T-Mobile data plan MICROINVERTERS, ACCESSORIES AND REPLACEMENT PARTS (not included; order separately) UNITS Supported microinverters —IQ6, IQ7, and IQ8. Do not mix IQ6/IQ7 Microinverters with IQ8 Enphase Communications Kit COMMS-CELLMODEM-M1-06 CELLMODEM-M1-06-SP-05 CELLMODEM-M1-06-AT-05 — - Includes COMMS-KIT-01 and CELLMODEM-M1-06-SP-05 with a 5-year T-Mobile data plan for Enphase sites - 4G-based LTE-M1 cellular modem with a five-year T-Mobile data plan - 4G-based LTE-M1 cellular modem with a five-year AT&T data plan Circuit breakers (off-the-shelf) — Supports Eaton BR2xx, Siemens Q2xx and GE/ABB THQL21xx Series breakers (xx may be 10, 15, 20, 30, 40, 50, or 60). Supports Eaton BR220B, BR230B, and BR240B circuit breakers compatible with hold-down kit. Circuit breakers (provided by Enphase)—BRK-10A-2-240V, BRK-15A-2-240V, BRK-20A-2P-240V, BRK-15A-2P-240V-B, and BRK-20A-2P-240V-B XA-SOLARSHIELD-ES —Replacement solar shield for IQ Combiner 4/4C XA-ENV2-PCBA-4 —IQ Gateway replacement printed circuit board (PCB) for IQ Combiner 4/4C XA-PLUG-120-3 —Accessory receptacle for power line carrier in IQ Combiner 4/4C (required for EPLC-01) X-IQ-NA-HD-125A —Hold-down kit for Eaton circuit breaker with screws ELECTRICAL SPECIFICATIONS UNITS Rating A 80 System voltage and frequency —120/240 VAC, 120/208 VAC, 60 Hz Busbar rating A 125 Fault current rating kAIC 10 Maximum continuous current rating (input from PV/storage)A 64 Maximum fuse/Circuit rating (output)A 90 Branch circuits (solar and storage)—Up to four 2-pole Eaton BR, Siemens Q, or GE/ABB THQL Series distributed generation (DG) breakers only (not included) Maximum total branch circuit breaker rating (input)A 80 A of distributed generation/95 A with IQ Gateway breaker included To learn more about Enphase offerings, visit enphase.com. IQC-4-4C-DSH-00217-3.0-EN-US-2024-08-16 COMMUNICATION INTERFACES UNITS DESCRIPTION Integrated Wi-Fi —802.11b/g/n (dual band 2.4 GHz/5 GHz) for connecting the Enphase Cloud through the internet Wi-Fi range (recommended)m (ft)10 (32.8) Ethernet —Optional 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included) for connecting to the Enphase Cloud through the internet Digital I/O —Digital input/output for grid operator control USB 2.0 —For Mobile Connect, Communications Kit 1 for IQ Battery 3/3T/10/10T, Communication Kit 2 for IQ Battery 5P Access point (AP) mode —For connection between the IQ Gateway and a mobile device running the Enphase Installer App Metering ports —Up to two Consumption CTs, one IQ Battery CT, and one Production CT Power line communication kHz 90–110 Web API — See https://developer-v4.enphase.com Local API —See Guide for local API Cellular/Mobile Connect — CELLMODEM-M1-06-SP-05, CELLMODEM-M1-06-AT-05 (4G-based LTE-M1 cellular modem). Note that an Enphase Mobile Connect cellular modem is required for all installations with Enphase IQ Batteries and/or IQ System Controllers COMPLIANCE IQ Combiner with IQ Gateway CA Rule 21 (UL 1741-SA) IEEE 1547:2018 - UL 1741-SB, 3rd Ed. (X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C) CAN/CSA C22.2 No. 107.1, 47 CFR, Part 15, Class B, ICES 003, NOM-208-SCFI-2016 Production metering: ANSI C12.20 accuracy class 0.5 (PV production), UL 61010-1, CAN/CSA 22.2 No. 61010-1, IEEE 2030.5/CSIP Compliant COMPATIBILITY PV Microinverters IQ6, IQ7, and IQ8 Series Microinverters COMMS-KIT-01 IQ System Controller EP200G101-M240US00 IQ System Controller 2 EP200G101-M240US01 IQ Battery ENCHARGE-3-1P-NA, ENCHARGE-10-1P-NA, ENCHARGE-3T-1P-NA, ENCHARGE-10T-1P-NA COMMS-KIT-021 IQ System Controller 3 SC200D111C240US01, SC200G111C240US01 IQ Battery IQBATTERY-5P-1P-NA MECHANICAL DATA UNITS DESCRIPTION Dimensions (W × H × D)cm (in)37.5 × 49.5 × 16.8 (14.75 × 19.5 × 6.63). Height is 53.5 (21.06) with mounting brackets Weight kg (lb)7.5 (16.5) Ambient temperature range °C (°F)-40 to 46 (-40 to 115) Cooling —Natural convection plus a heat shield Enclosure environmental rating —Outdoor, NRTL-certified, NEMA type 3R, polycarbonate construction Wire sizes — • 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors • 60 A breaker branch input: 4 to 1/0 AWG copper conductors • Main lug combined output: 10 to 2/0 AWG copper conductors • Neutral and ground: 14 to 1/0 copper conductors Always follow local code requirements for conductor sizing Altitude m (ft)Up to 2,600 (8,530) 1 For information about IQ Combiner 4/4C compatibility with the 3rd-generation batteries, refer to the compatibility matrix. ELECTRICAL SPECIFICATIONS UNITS IQ Gateway breaker A 10 A or 15 A rating GE/Siemens/Eaton included Production metering CT A 200 A solid core pre-installed and wired to IQ Gateway Consumption monitoring CT (CT-200-SPLIT/CT- 200-CLAMP)A A pair of 200 A split core or clamp-type current transformers IQC-4-4C-DSH-00217-3.0-EN-US-2024-08-16 Revision history REVISION DATE DESCRIPTION DSH-00217-3.0 August 2024 Updated the system voltage value. Updated Sprint plan to T-Mobile data plan. DSH-00217-2.0 April 2024 Updated the UL smart mark. DSH-00217-1.0 February 2024 Initial release. Previous releases. © 2024 Enphase Energy. All rights reserved. Enphase, the e and CC logos, IQ, and certain other marks listed at https://enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the U.S. and other countries. Data subject to change. SunPower® InvisiMount™ | Residential Mounting System Simple and Fast Installation • Integrated module-to-rail grounding • Pre-assembled mid and end clamps • Levitating mid clamp for easy placement • Mid clamp width facilitates even module spacing • Simple, pre-drilled rail splice • UL 2703 Listed integrated grounding Flexible Design • Addresses nearly all sloped residential roofs • Design in landscape and portrait • Rails enable easy obstacle management Customer-Preferred Aesthetics • #1 module and #1 mounting aesthetics • Best-in-class system aesthetics • Premium, low-profile design • Black anodized components • Hidden mid clamps and end clamps hardware, and capped, flush rails Part of Superior System • Built for use with SunPower DC and AC modules • Best-in-class system reliability and aesthetics • Combine with SunPower modules and monitoring app sunpower.com Elegant Simplicity SunPower® InvisiMount™ is a SunPower-designed rail-based mounting system. The InvisiMount system addresses residential sloped roofs and combines faster installation time, design flexibility, and superior aesthetics. The InvisiMount product was specifically envisioned and engineered to pair with SunPower modules. The resulting system-level approach will amplify the aesthetic and installation benefits for both homeowners and installers. SunPower® InvisiMount™ | Residential Mounting System InvisiMount Component Details Component Material Weight Mid Clamp Black oxide stainless steel AISI 304 63 g (2.2 oz) End Clamp Black anodized aluminum alloy 6063-T6 110 g (3.88 oz) Rail Black anodized aluminum alloy 6005-T6 830 g/m (9 oz/ft) Rail Splice Aluminum alloy 6005-T5 830 g/m (9 oz/ft) Ground Lug Assembly 304 stainless (A2-70 bolt; tin-plated copper lug)106.5 g/m (3.75 oz) End Cap Black acetal (POM) copolymer 10.4 g (0.37 oz) Roof Attachment Hardware Supported by InvisiMount System Design Tool Application • Composition Shingle Rafter Attachment • Composition Shingle Roof Decking Attachment • Curved and Flat Tile Roof Attachment • Universal Interface for Other Roof Attachments InvisiMount Operating Conditions Temperature −40° C to 90° C (−40° F to 194° F) Max. Load 2400 Pa uplift 5400 Pa downforce Roof Attachment Hardware Warranties Refer to roof attachment hardware manufacturer’s documentation InvisiMount Warranties And Certifications Warranties 25-year product warranty 5-year finish warranty Certifications UL 2703 Listed Class A fire rating when distance between roof surface and bottom of SunPower module frame is ≤ 3.5” *Module frame that is compatible with the InvisiMount system required for hardware interoperability. © 2015 SunPower Corporation. All Rights Reserved. SUNPOWER, the SUNPOWER logo, and INVISIMOUNT are trademarks or registered trademarks of SunPower Corporation. All other trademarks are the property of their respective owners. Specifications included in this datasheet are subject to change without notice. InvisiMount Component Images Module* / Mid Clamp and Rail Mid Clamp End Clamp Rail & Rail Splice Ground Lug Assembly End Cap Module* / End Clamp and Rail sunpower.com Document #509506 Rev B The extra-large L-foot and proprietary lag screw result in larger spans between mounts Larger Spans Manufactured with advanced materials and coatings to outlast the roof itself 25-Year Warranty Fully IBC/CBC Code Compliant Exceeds ASCE 7-16 Standards FL Cert of Approval FL41396 UL2703 Certified Code Compliant The proprietary non-hardening sealant will flex and reseal over years of thermal expansion and contraction Self-Healing Pegasus Solar Inc | 506 West Ohio Avenue, Richmond, CA 94804 | www.pegasussolar.com Effortless Lifetime Roof Protection The non-hardening sealant completely fills any missed pilot holes, shingle rips, voids, or other potential water ingress points under the entire footprint of the 4.6” wide base. Before InstaFlash Installed:Sealant is contained above roof surface by a protective cage. After InstaFlash Installed:Sealant is compressed to fill all holes and voids. Factory-installed, non-hardening sealant Prevents sealant from getting on hands or roof. Collapses upon lag installation. Protective Cage Never Deal With Caulking Again! 1 Drill pilot hole in the center of the rafterusing a 7/32” bit. 2 Place the InstaFlash over the pilot hole. Note: the direction of the InstaFlash Down arrows should point down the roof. 4Drive the lag until the InstaFlash is fully seated to the roof. 3 Insert the lag screw through the center hole into the pilot hole. Pegasus Solar Inc | 506 West Ohio Avenue, Richmond, CA 94804 | www.pegasussolar.com PIF-RB0 PIF-RBDT PIF-RBSH PIF-RM0 PIF-RMDT Finish Kit Contents Black InstaFlash, 5/16” x 4.0” SS Lag Black InstaFlash, 5/16” x 4.0” SS Lag, Dovetail T-bolt w/ Nut Black InstaFlash, 5/16” x 4.0” SS Lag, M10 Hex Bolt w/ Nut Mill Insta-Flash, 5/16” x 4.0” SS Lag Mill InstaFlash, 5/16” x 4.0” SS Lag, Dovetail T-bolt w/ Nut Attachment Type Rafter Attached Roof Type Sealant Application Factory Installed Installation Temperature Cure Time Service Temperature Certifications Install Application Kit Quantity 24 Boxes per Pallet 36 SPECIFICATIONS INSTAFLASH KITS Black Mill US Patents Pending. All rights reserved. ©2023 Pegasus Solar Inc. IBC, ASCE/SEI 7-16, FL Cert of Approval FL41396, TAS 100(A), UL2703 Instantly Waterproof; Non-hardening 0°F to 170° F -40°F to 195° F Most Railed Systems, Pegasus Tilt Leg Kit Sloped Roof: Composition Shingle, Rolled Asphalt | Flat roof: Modified Bitumen Roof, Built-Up Roof SCAN FOR INSTALLATION VIDEO SCAN FOR FREE TRIAL Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation. Catalog Number U4801-XL-5T9 Marketing Product Description 5 Terminal Ringless Small Closing Plate Lever Bypass 5th Terminal 9 Oclock Position UPC 784572288218 Length (IN)4.844 Width (IN)13 Height (IN)19 Brand Name Milbank Type Ringless Meter Socket Application Meter Socket Standard UL Listed;Type 3R Voltage Rating 600 Volts Alternating Current Amperage Rating 200 Continuous Ampere Phase 1 Phase Frequency Rating 60 Hertz Size 4.844L x 13W x 19H Number Of Cutouts 0 Cutout Size No Main Breaker Cable Entry Overhead or Underground Terminal Lay in Insulation Glass Polyester Mounting Surface Mount Enclosure G90 Galvanized Steel with Powder Coat Finish Jaw Quantity 5 Terminal Bypass Type Lever Bypass Number of Meter Positions 1 Position Equipment Ground Bonded Ground Strap Hub Opening Small Closing Plate Line Side Wire Range 6 AWG - 350 kcmil Load Side Wire Range 6 AWG - 350 kcmil Number Of Receptacles 0 U4801-XL-5T9 1092206 11625 PROSPEROUS DRIVE ODESSA, FL 33556 FIGURE 1IT FIGURE 4ITO FIGURE 2DUAL ENTRY CONTACT NSi FOR SALES @ 800.321.5847 FIGURE 3ITH NOTES:1. CONNECTOR MANUFACTURED FROM 6061-T6 ALUMINUM ALLOY.2. UL LISTED PER UL486A/B SPECIFICATIONS FOR 600V.3. DUAL RATED FOR 90 C COPPER AND/OR ALUMINUM CONDUCTOR.4. COLD TEMPERATURE RATED TO -45 C.5. HIGH DIELECTRIC STRENGTH INSULATION IS ABRASION, CHEMICAL AND UV RESISTANT. *NOT UL LISTED tt 600 SERIES ARE AL7CU AND 75 C PART #FIG. #WIRE RANGE HEX SIZE L W H IT4 1 4 - 14 SLOTTED 1.12 1.18 1.38 ITO4 4 4 - 14 SLOTTED 1.12 1.25 1.38 IT1/0 1 1/0 - 14 3/16 1.62 1.62 1.75 ITO1/0 4 1/0 - 14 3/16 1.62 1.75 1.75 IT3/0 1 3/0 - 6 1/4 1.84 1.75 1.87 ITO3/0 4 3/0 - 6 1/4 1.84 1.87 1.87 IT250 2 250 - 6 5/16 2.12 2.25 2.25 IT350 2 350 - 6 5/16 2.47 2.50 2.44 IT500 2 500 - 4 5/16 2.81 2.87 2.94 IT750*2 750 - 250 3/8 3.48 3.50 3.50 IT600tt 2 600 - 6 5/16 2.34 2.94 3.05 ITH750 3 750 - 250 5/16 3.48 4.50 3.50 DWG. NO. TITLE: PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF POLARIS SALES CO. INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF POLARIS SALES CO. INC. IS PROHIBITED. IT SERIESINSULATEDCONNECTORS SALES A CO A INCPOLARIS IT SERIES SHEET: 1 OF 1NOT TO SCALE DATE DRAWN BY N/AMATERIAL: S.PARRY 6/13/2012 NAME ® VSE Project Number: U3594.0103.251 January 31, 2025 Wolf River Electric ATTENTION: Vladimir Marchenko 101 Isanti Parkway NE Isanti, MN 55040 REFERENCE: Suzanne Stauduhar Residence: 4725 Bayside Road, Maple Plain, MN 55359 Solar Array Installation To Whom It May Concern: We have reviewed the existing structure at the above referenced site.The purpose of our review was to determine the adequacy of the existing structure to support the proposed installation of solar panels on the roof as shown on the panel layout plan. Based upon our review, we conclude the existing structure is adequate to support the proposed solar panel installation. Design Parameters Code: 2020 Minnesota Residential Code (2018 IRC) Risk Category: II Design wind speed, Vult: 115 mph (3-sec gust) Wind exposure category: C Ground snow load, Pg: 50 psf Existing Roof Structure Roof structure: 2x4 manufactured trusses @ 24" o.c. Roofing material: asphalt (composite) shingles Roof 1: roof pitch of 3.8:12 Roof 2: roof pitch of 6:12 Connection to Roof Mounting connection: (1) 5/16" lag screw w/ min. 2.5" threaded embedment into framing at max. 48" o.c. along rails • Install (2) rails per row of panels, evenly spaced from panel center • Panel length perpendicular to the rails shall not exceed 74 in • Rail cantilever shall not exceed the lesser of 50% of the connection spacing or max cantilever allowed by manufacturer • At flat hip framing, if occurs, reduce connection spacing listed above by 50% or see attached detail for blocking option. • Connections shall be staggered so as not to overload any existing structural member 651 W. Galena Park Blvd., Ste. 101 / Draper, UT 84020 / T (801) 990-1775 / F (801) 990-1776 / www.vectorse.com Reviewed for Code Compliance Nicole Post SES25-000001 2-4-25 Approved plans must be on site for the duration of the project. Plans must be available to inspector. Please call 952-249-6000 to schedule all inspections. Have permit number and address when calling. Separate Permits Required Electrical ® VSE Project Number: U3594.0103.251 Suzanne Stauduhar Residence 1/31/2025 Conclusions Based upon our review,we conclude the existing structure is adequate to support the proposed solar panel installation.The glass surface of the solar panels allows for a lower slope factor per ASCE 7,resulting in reduced design snow load on the panels.The gravity loads,and thus the stresses of the structural elements,in the area of the solar array are either decreased or increased by no more than 5%.Stress decreases or increases of no more than 5%are considered acceptable.Therefore,the structure is permitted to remain unaltered. The solar array will be flush-mounted (no more than 10"above the roof surface)and parallel to the roof surface.Thus,we conclude that any additional wind loading on the structure related to the addition of the proposed solar array is negligible. The attached calculations verify the capacity of the connections of the solar array to the existing roof against wind (uplift), the governing load case.Increases in lateral forces less than 10%are considered acceptable.Thus the existing lateral force resisting system is permitted to remain unaltered. Limitations Installation of the solar panels must be performed in accordance with manufacturer recommendations.All work performed must be in accordance with accepted industry-wide methods and applicable safety standards.The contractor must notify Vector Structural Engineering,LLC should any damage,deterioration or discrepancies between the as-built condition of the structure and the condition described in this letter be found.The use of solar panel support span tables provided by others is allowed only where the building type,site conditions,site-specific design parameters,and solar panel configuration match the description of the span tables.The design of the solar panels,solar racking (mounts,rails,etc.)and electrical engineering is the responsibility of others.Waterproofing around the roof penetrations is the responsibility of others.Vector Structural Engineering assumes no responsibility for improper installation of the solar array.Vector Structural Engineering shall be notified of any changes from the approved layout prior to installation. VECTOR STRUCTURAL ENGINEERING, LLC 01/31/2025 _______________________________________________________ Kelly Springer, P.E. Project Engineer Enclosures KGS/acs I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the State of Minnesota. Kelly Springer, License No. 60925, Expiration Date: 30-June-2026 01/31/2025 651 W. Galena Park Blvd., Ste. 101 / Draper, UT 84020 / T (801) 990-1775 / F (801) 990-1776 / www.vectorse.com ®I hereby certify that this plan, specificationor report was prepared by me or under mydirect supervision and that I am a dulyLicensed Professional Engineer under thelaws of the State of Minnesota,Kelly G. Springer, License No. 60925,Expiration Date: 30-June-202601/31/2025VSE Project Number: U3594.0103.251 JOB NO.:U3594.0103.251 SUBJECT:WIND PRESSURE ® Roof 1 PROJECT:Suzanne Stauduhar Residence Label:Note: Calculations per ASCE 7-10 SITE-SPECIFIC WIND PARAMETERS: Basic Wind Speed [mph]:115 Notes: Exposure Category:C Risk Category:II Importance Factor, I: ADDITIONAL INPUT & CALCULATIONS: Height of Roof, h [ft]:25 (Approximate)Hip? Comp/Cladding Location:Yes Enclosure Classification: Zone 1 GCp:0.9 Figure 30.4-2B (enter negative pressure coefficients) Zone 2 GCp:1.7 Zone 3 GCp:1.7 α:9.5 Table 26.9-1 zg [ft]:900 Table 26.9-1 Kh:0.95 Table 30.3-1 Kzt:1 Equation 26.8-1 Kd:0.85 Table 26.6-1 Velocity Pressure, qh [psf]:27.2 Equation 30.3-1 GCpi:0 Table 26.11-1 PRESSURES:Equation 30.9-1 Zone 1, p [psf]:24.3 psf (1.0 W, Interior Zones, beyond 'a' from roof edge) Zone 2, p [psf]:45.0 psf (1.0 W, End Zones, within 'a' from roof edge) Zone 3, p [psf]:45.0 psf (1.0 W, Corner Zones, within 'a' from roof corner) (a= 3 ft) Solar Panel Array Gable/Hip Roofs 7° < θ ≤ 27° Enclosed Buildings Components and Cladding Wind Calculations ()()piphGCGCqp−= JOB NO.:U3594.0103.251 SUBJECT:CONNECTION ® Roof 1 PROJECT:Suzanne Stauduhar Residence Calculate Uplift Forces on Connection Pressure (0.6 Dead -0.6 Wind) (psf) Max Trib. Width1 (ft) Max Trib. Area2 (ft2) Max Uplift Force (lbs) Zone 1 12.8 4.0 12.3 157 Zone 2 25.2 4.0 12.3 310 Zone 3 25.2 4.0 12.3 310 Calculate Connection Capacity Lag Screw Size [in]:5/16 Cd:1.6 NDS Table 2.3.2 Embedment3 [in]:2.5 Grade: Nominal Capacity [lbs/in]:205 NDS Table 12.2A Number of Screws:1 Prying Coefficient:1.4 Total Capacity [lbs]:586 Determine Result Maximum Demand [lbs]:310 Lag Screw Capacity [lbs]:586 Result:Capacity > Demand, Connection is adequate. Notes 1. 'Max Trib. Width' is the width along the rails tributary to the connection. 2. 'Max Trib Area' is the product of the 'Max. Trib Width' and 1/2 the panel width/height perpendicular to the rails. (2) rails per row of panels. Length of panels perpendicular to the rails shall not exceed 74". 3. Embedment is measured from the top of the framing member to the beginning of the tapered tip of the lag screw. Embedment in sheathing or other material is not effective. The length of the tapered tip is not part of the embedment length. SPF (G = 0.42) VECTOR STRUCTURAL ENGINEERS JOB NO.:U3594.0103.251 SUBJECT:GRAVITY LOADS ® Roof 1 PROJECT:Suzanne Stauduhar Residence GRAVITY LOADS Roof Pitch: 3.8 :12 ROOF DEAD LOAD (D) Increase due to pitch Material weight [psf] Asphalt (Composite) Shingles 1.05 2.0 1/2" Plywood 1.05 1.0 Framing 1.00 3.0 Insulation 1.00 0.5 1/2" Gypsum Clg.1.05 2.0 M, E & Misc 1.00 6.5 Total Existing Roof DL PV Array DL 1.05 3 DL:1.05 ROOF LIVE LOAD (Lr) Existing Design Roof Live Load [psf]20 ASCE 7-16 Table 4.3-1 Roof Live Load With PV Array [psf]0 SNOW LOAD (S):w/ Solar Array Roof Slope [x:12]:3.8 Roof Slope [°]:18 Ground Snow Load, pg [psf]:50 ASCE 7-16, Section 7.2 Terrain Category:C ASCE 7-16, Table 7.3-1 Exposure of Roof:Fully Exposed ASCE 7-16, Table 7.3-1 Exposure Factor, Ce:0.9 ASCE 7-16, Table 7.3-1 Thermal Factor, Ct:1.1 ASCE 7-16, Table 7.3-2 Risk Category:II ASCE 7-16, Table 1.5-1 Importance Factor, Is:1.0 ASCE 7-16, Table 1.5-2 Flat Roof Snow Load, pf [psf]:35 ASCE 7-16, Equation 7.3-1 Minimum Roof Snow Load, pm [psf]:0 ASCE 7-16, Section 7.3.4 Unobstructed Slippery Surface?Yes ASCE 7-16, Section 7.4 Slope Factor Figure:Figure 7-2b ASCE 7-16, Section 7.4 Roof Slope Factor, Cs:0.87 ASCE 7-16, Figure 7.4-1 Sloped Roof Snow Load, ps [psf]:30 ASCE 7-16, Equation 7.4-1 Design Snow Load, S [psf]:30 1.00 35 Design material weight [psf] 2.1 1.0 3.0 0.5 2.1 6.5 15.2 3.1 #VALUE! 2020 MRC, Section R324.4.1.1 Existing 35 3.8 18 50 C Fully Exposed 0.9 1.1 II 1.0 35 0 No Figure 7-2b JOB NO.:U3594.0103.251 SUBJECT:LOAD COMPARISON ® Roof 1 PROJECT:Suzanne Stauduhar Residence Summary of Loads Existing With PV Array D [psf]15 18 Lr [psf]20 0 S [psf]35 30 Maximum Gravity Loads: Existing With PV Array (D + Lr) / Cd [psf]28 20 ASCE 7-16, Section 2.4.1 (D + S) / Cd [psf]43 42 ASCE 7-16, Section 2.4.1 Maximum Gravity Load [psf]:43 42 Ratio Proposed Loading to Current Loading:98%OK The gravity loads, and thus the stresses of the structural elements, in the area of the solar array are either decreased or increased by no more than 5%. Stress decreases or increases of no more than 5% are considered acceptable. Therefore, the structure is permitted to remain unaltered. (Cd = Load Duration Factor = 0.9 for D, 1.15 for S, and 1.25 for Lr) JOB NO.:U3594.0103.251 SUBJECT:WIND PRESSURE ® Roof 2 PROJECT:Suzanne Stauduhar Residence Label:Note: Calculations per ASCE 7-10 SITE-SPECIFIC WIND PARAMETERS: Basic Wind Speed [mph]:115 Notes: Exposure Category:C Risk Category:II Importance Factor, I: ADDITIONAL INPUT & CALCULATIONS: Height of Roof, h [ft]:25 (Approximate)Hip? Comp/Cladding Location:Yes Enclosure Classification: Zone 1 GCp:0.9 Figure 30.4-2B (enter negative pressure coefficients) Zone 2 GCp:1.7 Zone 3 GCp:2.5 α:9.5 Table 26.9-1 zg [ft]:900 Table 26.9-1 Kh:0.95 Table 30.3-1 Kzt:1 Equation 26.8-1 Kd:0.85 Table 26.6-1 Velocity Pressure, qh [psf]:27.2 Equation 30.3-1 GCpi:0 Table 26.11-1 PRESSURES:Equation 30.9-1 Zone 1, p [psf]:24.3 psf (1.0 W, Interior Zones, beyond 'a' from roof edge) Zone 2, p [psf]:45.0 psf (1.0 W, End Zones, within 'a' from roof edge) Zone 3, p [psf]:69.2 psf (1.0 W, Corner Zones, within 'a' from roof corner) (a= 3 ft) Solar Panel Array Gable/Hip Roofs 7° < θ ≤ 27° Enclosed Buildings Components and Cladding Wind Calculations ()()piphGCGCqp−= JOB NO.:U3594.0103.251 SUBJECT:CONNECTION ® Roof 2 PROJECT:Suzanne Stauduhar Residence Calculate Uplift Forces on Connection Pressure (0.6 Dead -0.6 Wind) (psf) Max Trib. Width1 (ft) Max Trib. Area2 (ft2) Max Uplift Force (lbs) Zone 1 12.8 4.0 12.3 157 Zone 2 25.2 4.0 12.3 310 Zone 3 39.7 4.0 12.3 488 Calculate Connection Capacity Lag Screw Size [in]:5/16 Cd:1.6 NDS Table 2.3.2 Embedment3 [in]:2.5 Grade: Nominal Capacity [lbs/in]:205 NDS Table 12.2A Number of Screws:1 Prying Coefficient:1.4 Total Capacity [lbs]:586 Determine Result Maximum Demand [lbs]:488 Lag Screw Capacity [lbs]:586 Result:Capacity > Demand, Connection is adequate. Notes 1. 'Max Trib. Width' is the width along the rails tributary to the connection. 2. 'Max Trib Area' is the product of the 'Max. Trib Width' and 1/2 the panel width/height perpendicular to the rails. (2) rails per row of panels. Length of panels perpendicular to the rails shall not exceed 74". 3. Embedment is measured from the top of the framing member to the beginning of the tapered tip of the lag screw. Embedment in sheathing or other material is not effective. The length of the tapered tip is not part of the embedment length. SPF (G = 0.42) VECTOR STRUCTURAL ENGINEERS JOB NO.:U3594.0103.251 SUBJECT:GRAVITY LOADS ® Roof 2 PROJECT:Suzanne Stauduhar Residence GRAVITY LOADS Roof Pitch: 6.0 :12 ROOF DEAD LOAD (D) Increase due to pitch Material weight [psf] Asphalt (Composite) Shingles 1.12 2.0 1/2" Plywood 1.12 1.0 Framing 1.00 3.0 Insulation 1.00 0.5 1/2" Gypsum Clg.1.12 2.0 M, E & Misc 1.00 6.5 Total Existing Roof DL PV Array DL 1.12 3 DL:1.12 ROOF LIVE LOAD (Lr) Existing Design Roof Live Load [psf]20 ASCE 7-16 Table 4.3-1 Roof Live Load With PV Array [psf]0 SNOW LOAD (S):w/ Solar Array Roof Slope [x:12]:6.0 Roof Slope [°]:27 Ground Snow Load, pg [psf]:50 ASCE 7-16, Section 7.2 Terrain Category:C ASCE 7-16, Table 7.3-1 Exposure of Roof:Fully Exposed ASCE 7-16, Table 7.3-1 Exposure Factor, Ce:0.9 ASCE 7-16, Table 7.3-1 Thermal Factor, Ct:1.1 ASCE 7-16, Table 7.3-2 Risk Category:II ASCE 7-16, Table 1.5-1 Importance Factor, Is:1.0 ASCE 7-16, Table 1.5-2 Flat Roof Snow Load, pf [psf]:35 ASCE 7-16, Equation 7.3-1 Minimum Roof Snow Load, pm [psf]:0 ASCE 7-16, Section 7.3.4 Unobstructed Slippery Surface?No ASCE 7-16, Section 7.4 Slope Factor Figure:Figure 7-2b ASCE 7-16, Section 7.4 Roof Slope Factor, Cs:1.00 ASCE 7-16, Figure 7.4-1 Sloped Roof Snow Load, ps [psf]:35 ASCE 7-16, Equation 7.4-1 Design Snow Load, S [psf]:35 1.00 35 Design material weight [psf] 2.2 1.1 3.0 0.5 2.2 6.5 15.6 3.4 #VALUE! 2020 MRC, Section R324.4.1.1 Existing 35 6.0 27 50 C Fully Exposed 0.9 1.1 II 1.0 35 0 No Figure 7-2b JOB NO.:U3594.0103.251 SUBJECT:LOAD COMPARISON ® Roof 2 PROJECT:Suzanne Stauduhar Residence Summary of Loads Existing With PV Array D [psf]16 19 Lr [psf]20 0 S [psf]35 35 Maximum Gravity Loads: Existing With PV Array (D + Lr) / Cd [psf]28 21 ASCE 7-16, Section 2.4.1 (D + S) / Cd [psf]44 47 ASCE 7-16, Section 2.4.1 Maximum Gravity Load [psf]:44 47 Maximum Member Forces: GEOMETRY Span(ft)27.0 (Approximate) Solar Panel Array Start, a (ft)6.0 (Approximate) Solar Panel Array Length, b (ft)5.5 (Approximate) Framing Spacing (ft)2.0 MEMBER FORCES Existing With PV Array Vertical Reaction, V1 (lbs)1180 1201 OK Vertical Reaction, V2 (lbs)1180 1190 OK Existing With PV Array Moment @ Center, M (lbs-ft)7962 8102 OK Ratio The gravity loads, and thus the stresses of the structural elements, in the area of the solar array are either decreased or increased by no more than 5%. Stress decreases or increases of no more than 5% are considered acceptable. Therefore, the structure is permitted to remain unaltered. (Cd = Load Duration Factor = 0.9 for D, 1.15 for S, and 1.25 for Lr) Ratio 102% 102% 101% a. THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING THE SPECIFIED RAIL SYSTEM. THE MOUNTING FEET ARE TO BE SPACED AS SHOWN IN THE DETAILS, AND MUST BE STAGGERED TO ADJACENT FRAMING MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD. b. UNLESS NOTED OTHERWISE, MOUNTING ANCHORS SHALL BE 516" LAG SCREWS WITH A MINIMUM OF 2 12" PENETRATION INTO ROOF FRAMING. c. THE PROPOSED PV SYSTEM ADDS 3.0 psf TO THE ROOF FRAMING SYSTEM. 1. ROOF LIVE LOAD = 35 psf TYPICAL, 0 psf UNDER NEW PV SYSTEM. 2. GROUND SNOW LOAD = 50 psf 3. WIND SPEED = 115 mph 4. EXPOSURE CATEGORY = CGENERAL STRUCTURAL NOTES:PHOTOVOLTAIC SYSTEM SPECIFICATIONS BUILDING: HENNEPIN COUNTY ZONING: HENNEPIN COUNTY UTILITY: WRIGHT HENNEPIN UTILITY METER #342674200AUTHORITIES HAVING JURISDICTIONSatellite ViewVicinity MapSheet NumberWOLF RIVER ELECTRIC101 ISANTI PARKWAY NE,SUITE G ISANTI, MN 55040ELECTRICAL LICENSE:EA777669Contact: (763) 229-6662contact@wolfriverelectric.comSheet NumberDESIGNED BY:WOLF RIVERELECTRICRevisions TableDescriptionDateRev.Sheet Name &Creation DateEngineer Signature & StampBuilding License :BC7732711.ALL COMPONENTS ARE UL LISTED AND CEC CERTIFIED, WHERE WARRANTED.2.THE SOLAR PV SYSTEM WILL BE INSTALLED IN ACCORDANCE WITH ARTICLE 690 OF THE NEC 20233.THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEM INSPECTED PRIOR TO PARALLEL OPERATION.4.ALL CONDUCTORS OF A CIRCUIT, INCLUDING THE EGC, MUST BE INSTALLED IN THE SAME RACEWAY, OR CABLE, OR OTHERWISE RUN WITH THE PV ARRAY CIRCUIT CONDUCTORS WHEN THEY LEAVE THE VICINITY OF THE PV ARRAY.5.WHERE METALLIC CONDUIT CONTAINING DC CONDUCTORS IS USED INSIDE THE BUILDING, IT SHALL BE IDENTIFIED AS "CAUTION: SOLAR CIRCUIT" EVERY 10FT.6.HEIGHT OF THE AC DISCONNECT SHALL NOT EXCEED 6'-7" PER NEC CODE 240.24.7.A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH CEC 690.47 AND 250.50 THROUGH 60 AND 250-166 SHALL BE PROVIDED. PER NEC GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED AND BONDED TO THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE OR INADEQUATE A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT. GROUND ROD WITH ACORN CLAMP. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN #8 AWG AND NO LARGER THAN #6 AWG COPPER AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM.8.PHOTOVOLTAIC MODULES ARE TO BE CONSIDERED NON-COMBUSTIBLE.9.PHOTOVOLTAIC INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING. MECHANICAL, OR BUILDING ROOF VENTS.10.ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH USE. WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF THE ROOF SURFACE.11.ALL SINAGE TO BE PLACED IN ACCORDANCE WITH THE LOCAL BUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT. ALL PLAQUES AND SINAGE WILL BE INSTALLED AS REQUIRED BY THE NEC AND AHJ.12.AS SPECIFIED BY THE AHJ, EQUIPMENT USED IN UNGROUNDED SYSTEMS LABELED ACCORDING TO NEC 690.35(F).13.INVERTER(S) USED IN UNGROUNDED SYSTEM SHALL BE LISTED FOR THIS USE [NEC 690.35(G)].14.THE INSTALLATION OF EQUIPMENT AND ALL ASSOCIATED WIRING AND INTERCONNECTION SHALL BE PERFORMED ONLY BY QUALIFIED PERSONS [NEC 690.4(C)]15.ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED (OR BETTER), INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND SWITCHES.16.ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH NEC ARTICLE 250.17.SYSTEM GROUNDING SHALL BE IN ACCORDANCE WITH NEC 690.41.18.PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION IN ACCORDANCE WITH NEC 690.1219.DISCONNECTING MEANS SHALL BE LOCATED IN A VISIBLE, READILY ACCESSIBLE LOCATION WITHIN THE PV SYSTEM EQUIPMENT OR A MAXIMUM OF 10 FEET AWAY FROM THE SYSTEM [NEC 690.13(A)]20.ALL WIRING METHODS SHALL BE IN ACCORDANCE WITH NEC 690.3121.WORK CLEARANCES AROUND ELECTRICAL EQUIPMENT WILL BE MAINTAINED PER NEC 110.26(A)(1), 110.26(A)(2) AND 110.26(A)(3).22.ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED & IDENTIFIED IN ACCORDANCE WITH UL170323.ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND ANCHOR CONDUIT RUNS AS REQUIRED PER NEC.GENERAL ELECTRIC NOTESDesigner SignatureSUZANNE STAUDUHAR4725 Bayside Rd,Orono, MN 55359SHEET INDEX SYSTEM SIZE: MODULE TYPE & AMOUNT: MODULE DIMENSIONS: INVERTER: INTERCONNECTION METHOD:COVERSHEET01/24/2025PV-0.0 ALL WORK SHALL CONFORM TO THEFOLLOWING CODESa. 2023 NATIONAL ELECTRICAL CODEb. 2020 MINNESOTA RESIDENTIAL CODEc. 2020 MINNESOTA BUILDING CODEd. 2024 MINNESOTA ENERGY CODEe. 2020 MINNESOTA ACCESSIBILITY CODEf. 2020 MINNESOTA MECHANICAL & FUEL GAS CODEg. 2020 MINNESOTA PLUMBING CODEh. 2020 MINNESOTA STATE FIRE CODEi ANY OTHER LOCAL AMENDMENTSGOVERNING CODESSUZANNE STAUDUHAR 4725 Bayside Rd Orono, MN 55359 AHJ: HENNEPIN COUNTY UTILITY: WRIGHT HENNEPIN UTILITY METER #342674200 18 SUNPOWER SPR-M415-H-AC (415W)(L/W/H) 73.7"/40.6"/1.57"18 ENPHASE IQ7HS-66-M-US (SPWR-A5)[1 PHASE, 240V]SUPPLY SIDE TAP18 Modules - Roof Mounted7.470 kW DC6.912 kW ACPV-0.0COVER SHEETPV-1.0PLOT & SITE PLANPV-1.1STRING ATTACHMENTPV-1.2EQUIPMENT ELEVATIOND-2.0ATTAHCMENT DETAILD-2.13-LINE SHEETD-2.2PLACARD SHEETD-2.3WARNING SHEETI hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota,Kelly G. Springer, License No. 60925,Expiration Date: 30-June-202601/31/2025VSE Project Number: U3594.0103.251Vector Structural Engineering has reviewed the existingstructure with loading from the solar array and screwconnections to the existing framing. The design of theracking system, racking connections, and all otherstructural is by others. Mechanical, architectural, and allother nonstructural aspects of the design are by others.Electrical is by others, unless stamped by Dean Levorsen. M EM TB ACCM EM TB ACCPARCEL: 0611723220022PROPERTY LINEDRIVEWAYSYSTEM LEGENDLOT:2.55 ACRESFENCE LINEROOF SECTIONSMODULE - 14SLOPE - 10.0°/12AZIMUTH - 181.10°MATERIAL - ASPHALT SHINGLETRUSS SIZE & SPACING - 2"X4" @ 24" O.C.SYSTEM LEGENDPANELS & INVERTERS= ROOF OBSTRUCTIONSAC= ATTIC RUN CONDUIT= ATTIC RUN CONDUIT JUNCTION BOXEXISTING UTILITYMETER #342674200MEXISTING MAIN SERVICE PANELCNEW ENPHASE COMBINER= FIRE PATHWAYNEW UTILITY AC DISCONNECTTBNEW TAP BOXPMNEW UTILITY EXPORT METERMODULE - 4SLOPE - 10.0°/12AZIMUTH - 245.15°MATERIAL - ASPHALT SHINGLETRUSS SIZE & SPACING - 2"X4" @ 24" O.C.Sheet NumberSheet NumberWOLF RIVER ELECTRIC101 ISANTI PARKWAY NE,SUITE G ISANTI, MN 55040ELECTRICAL LICENSE:EA777669Contact: (763) 229-6662contact@wolfriverelectric.comSheet NumberDESIGNED BY:WOLF RIVERELECTRICRevisions TableDescriptionDateRev.Sheet Name &Creation DateEngineer Signature & StampBuilding License :BC773271Designer SignaturePV-1.0NOTE :1. THIS DRAWING IS FOR ILLUSTRATIVE PURPOSES ONLY!2. ALL TESTING SHALL BE PERFORMED BY QUALIFIEDPERSONNEL, WITH PROPER PERSONAL PROTECTIVEEQUIPMENT.3. 24/ 7 UNESCORTED KEYLESS ACCESS IS TO BEPROVIDED FOR ALL UTILITY EQUIPMENT.4. AC DISCONNECT SHOULD BE LOCATED TOGETHER IN AREADILY ACCESSIBLE LOCATION WITHIN 10' OF THE MAINSERVICE METER ROOF ACCESS POINTROOF ACCESS POINTS SHALL BE LOCATED IN AREAS THAT DO NOTREQUIRETHE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH ASWINDOWSOR DOORS, AND LOCATED AT STRONG POINTS OF BUILDINGCONSTRUCTIONIN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICTWITHOVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES AND ORSIGNSNOTE:ATTIC RUN CONDUIT SHALL BE MINIMUM 18INCHES FROM ROOF SHEATING1SITE PLAN & PLOT PLANPV 1.0ROOF #01ROOF #02PLOT & SITEPLAN01/24/2025NSUZANNE STAUDUHAR 4725 Bayside Rd Orono, MN 55359 AHJ: HENNEPIN COUNTY UTILITY: WRIGHT HENNEPIN UTILITY METER #342674200198'-0"411'-0"670'-0"40'-0"200'-0"75'-0"PROPERTY LINEDECKCONCRETEDRIVEWAY(PAVEMENT)NEW ENPHASECOMBINERNEW UTILITY ACDISCONNECTNEW TAP BOXNEW UTILITY EXPORTMETEREXISTING UTILITYMETER #200016038EXISTING MAIN SERVICEPANELROOF ACCESSPOINT18 SUNPOWER SPR-M415-H-AC (415W)(L/W/H) 73.7"/40.6"/1.57"18 ENPHASE IQ7HS-66-M-US (SPWR-A5)[1 PHASE, 240V]83'-0"42'-0"382'-0"SCALE: NTS (NOT TO SCALE)36" FIRE PATHWAY36" FIRE PATHWAY3 6 " F I R E P A T HW A Y 3 6 " F I R E P A T HW A Y 36" FIRE PATHWAY36" FIRE PATHWAY36" FIRE PATHWAY36" FIRE PATHWAYROOF OBSTRUCTIONROOF #01ROOF #02BAYSIDE ROADROOF ACCESSPOINTDRIVEWAY(PAVEMENT) M EM TB ACCSheet NumberSheet NumberWOLF RIVER ELECTRIC101 ISANTI PARKWAY NE,SUITE G ISANTI, MN 55040ELECTRICAL LICENSE:EA777669Contact: (763) 229-6662contact@wolfriverelectric.comSheet NumberDESIGNED BY:WOLF RIVERELECTRICRevisions TableDescriptionDateRev.Sheet Name &Creation DateEngineer Signature & StampBuilding License :BC773271Designer SignaturePV-1.1SCALE: NTS (NOT TO SCALE)ATTACHMENT AND STRING LAYOUTPV 1.1NOTE: THE MAXIMUM CANTILEVER OF THE RAILSHALL BE 1/3 OF THE ATTACHMENT SPACING.1ARRAY AREAMODULE AREAMODULE DIM (75.74 X 40.87)21.5 SQ. FT.AREA OF ARRAY367.22 SQ. FT.ROOF AREA3482.70 SQ. FT.ROOF COVERAGE %ROOF AREA/ARRAY AREA10.54%NSYSTEM LEGEND= ATTACHMENT POINTS(43 Nos)= TRUSS# MODULE - 9CIRCUIT #01# MODULE - 9CIRCUIT #02CIRCUIT(S)= RAIL SYSTEMSTRINGATTACHMENT01/24/2025B.O.M. BILL OF MATERIALSCATEGORYQTY.1181816626202120FEET48TERM CAPS4SEALING CAPS4CABLE SPLICES4311321140A FUSE 250VSURGE PROTECTORS60A AC DISCONNECT NEMA3 1P, 3W 120/240VGROUNDING RODS J-BOXSPR-M415-H-ACIQ7HS MICROINVERTER TRUNK CABLESEATON BR 20A 2-POLE BREAKERCONSUMPTIONMIDSENDSINVISIMOUNTENPHASE COMBINER200A (METER SOCKET) (MN) (U4801XL5T9)IT350 SPLICESCOMPONENTWEIGHTQTYTOTALWEIGHTMODULES (PER PIECE)48.50 lbs18873.00 lbsINVERTERS (PER PIECE)2.40 lbs1843.20 lbsSOLAR FOOT (PER PIECE)1.00 lbs4343.00 lbsINVISIMOUNT (PER LINEAL FOOT)6.00 lbs1696.00 lbsMIDS (PER PIECE)0.14 lbs263.64 lbsENDS (PER PIECE)0.24 lbs204.80 lbsSPLICES (PER PIECE)0.60 lbs63.60 lbsCOMPONENTS TOTAL WEIGHT 1067.24 lbsSUZANNE STAUDUHAR 4725 Bayside Rd Orono, MN 55359 AHJ: HENNEPIN COUNTY UTILITY: WRIGHT HENNEPIN UTILITY METER #342674200I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota,Kelly G. Springer, License No. 60925,Expiration Date: 30-June-202601/31/2025VSE Project Number: U3594.0103.251Vector Structural Engineering has reviewed the existingstructure with loading from the solar array and screwconnections to the existing framing. The design of theracking system, racking connections, and all otherstructural is by others. Mechanical, architectural, and allother nonstructural aspects of the design are by others.Electrical is by others, unless stamped by Dean Levorsen. SCALE: NTS1EQUIPMENT ELEVATIONPV 1.2INTERIOR WALLEXTERIOR WALLSheet NumberSheet NumberWOLF RIVER ELECTRIC101 ISANTI PARKWAY NE,SUITE G ISANTI, MN 55040ELECTRICAL LICENSE:EA777669Contact: (763) 229-6662contact@wolfriverelectric.comSheet NumberDESIGNED BY:WOLF RIVERELECTRICRevisions TableDescriptionDateRev.Sheet Name &Creation DateEngineer Signature & StampBuilding License :BC773271Designer SignaturePV-1.2EQUIPMENTELEVATION01/24/2025SUZANNE STAUDUHAR 4725 Bayside Rd Orono, MN 55359 AHJ: HENNEPIN COUNTY UTILITY: WRIGHT HENNEPIN UTILITY METER #342674200 EXISTING MAINSERVICE PANELEXTERIOR WALLNEW ENPHASECOMBINERENPHASENEW UTILITYEXPORT METERNEW PVCTAP BOXEXISTING UTILITYMETER#342674200NEW UTILITYAC DISCONNECTEND OF WALL4'<10'3'MAINTAIN 3' WORKINGCLEARANCEWINDOW Sheet NumberWOLF RIVER ELECTRIC101 ISANTI PARKWAY NE,SUITE G ISANTI, MN 55040ELECTRICAL LICENSE:EA777669Contact: (763) 229-6662contact@wolfriverelectric.comSheet NumberDESIGNED BY:WOLF RIVERELECTRICRevisions TableDescriptionDateRev.Sheet Name &Creation DateEngineer Signature & StampBuilding License :BC773271Designer SignatureD-2.0PLACARDSHEET01/24/20251ATTACHMENT DETAILD-2.0SCALE: NTSPV MODULES2"X4" TRUSS @ 24" OCMAXIMUM HEIGHT 6" FROM TOPOF THE ROOF TO TOP OF PANELSEE (2/S1.0) FORENLARGED VIEWPV MODULETOP BOLTGROUNDING & END/MID CLAMP2"X4" TRUSS @ 24" OC(E) COMP SHINGLE ROOF(E) COMP SHINGLE ROOF(1) 5/16" SS LAG BOLT WITH MIN 2 12"THREAD EMBEDMENT, SEALEDPENETRATION INTO TRUSS.SUNPOWER INVISIMOUNT RAILINSTAFLASH-FOOTSCALE: NTS2ATTACHMENT DETAIL (ENLARGED VIEWD-2.0THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING .(THE PEGASUS COMP MOUNT & SUNPOWER INVISIMOUNT RAIL SYSTEM), ANDMUST BE STAGGERED TO ADJACENT FRAMING MEMBERS TO SPREAD OUT THEADDITIONAL LOAD.B. UNLESS NOTED OTHERWISE, MOUNTING ANCHORS SHALL BE 516" LAGSCREWS WITH A MINIMUM OF 2 12" PENETRATION INTO ROOF FRAMINGC. THE PROPOSED PV SYSTEM ADDS 3.0 psf TO THE ROOF FRAMING SYSTEM1. ROOF LIVE LOAD = 35 psf TYPICAL, 0 psf UNDER NEW PV SYSTEM.2. GROUND SNOW LOAD = 50 psf3. WIND SPEED = 115 mphEXPOSURE CATEGORY = CGENERAL STRUCTURAL NOTESSUZANNE STAUDUHAR 4725 Bayside Rd Orono, MN 55359 AHJ: HENNEPIN COUNTY UTILITY: WRIGHT HENNEPIN UTILITY METER #342674200I hereby certify that this plan, specification or reportwas prepared by me or under my direct supervisionand that I am a duly Licensed Professional Engineerunder the laws of the State of Minnesota,Kelly G. Springer, License No. 60925,Expiration Date: 30-June-202601/31/2025VSE Project Number: U3594.0103.251Vector Structural Engineering has reviewed the existingstructure with loading from the solar array and screwconnections to the existing framing. The design of theracking system, racking connections, and all otherstructural is by others. Mechanical, architectural, and allother nonstructural aspects of the design are by others.Electrical is by others, unless stamped by Dean Levorsen. Sheet NumberWOLF RIVER ELECTRIC101 ISANTI PARKWAY NE,SUITE G ISANTI, MN 55040ELECTRICAL LICENSE:EA777669Contact: (763) 229-6662contact@wolfriverelectric.comSheet NumberDESIGNED BY:WOLF RIVERELECTRICRevisions TableDescriptionDateRev.Sheet Name &Creation DateEngineer Signature & StampBuilding License :BC773271Designer SignatureD-2.13-LINESHEET01/24/2025AHJ: HENNEPIN COUNTYUTILITY: WRIGHT HENNEPINNOTE: AC DISCONNECT TO BE INSTALLEDWITHIN 10FT FROM UTILITY METER.Photovoltaic SystemDC SYSTEM SIZE7.470 kWAC SYSTEM SIZE6.912 kWTOTAL MODULE COUNT18NOTES :1. THIS DRAWING IS FOR ILLUSTRATIVE PURPOSES ONLY!2. ALL TESTING SHALL BE PERFORMED BY QUALIFIED PERSONNEL, WITH PROPER PERSONAL PROTECTIVE EQUIPMENT.3. 24/ 7 UNESCORTED KEYLESS ACCESS IS TO BE PROVIDED FORALL UTILITY EQUIPMENT.4. THE PRODUCTION METER & AC DISCONNECT SHOULD BE LOCATED TOGETHER VISIBLE-OPEN LOCKABLE READILY ACCESSIBLE LOCATIONWITHIN 10’ OF THE MAIN SERVICE METER.5. THE METER SOCKET FOR THE PV PRODUCTION METER SHALL BE MARKED WITH A STAMPED BRASS, ALUMINUM, OR STAINLESS STEEL TAG,INDICATING THE ADDRESS INCLUDING THE UNIT, TYPICALLY “PV PROD” IN ACCORDANCE WITH THE REQUIREMENTS FOR “METERIDENTIFICATION” IN SECTION 4.14.4 OF THE XCEL ENERGY STANDARD, OR AS MAY BE AMENDED.6. THE PV PRODUCTION METER SHALL BE LOCATED WITHIN TEN (10) FEET OF THE EXISTING UTILITY METER. IF THERE IS ANY REASON THISCANNOT BE ACCOMPLISHED, THE APPROVAL OF THE PROPOSED PV PRODUCTION METERING WILL NEED TO BE OBTAINED BY THE LOCALELECTRIC METER SHOP.INVERTER SPECIFICATIONS 1- PHASEMANUFACTURERENPHASE IQ7HS-66-M-USMAX DC VOLT RATING59 VOLTSMAX POWER AT 40 C384 WATTSNOMINAL AC VOLTAGE240 VOLTSMAX AC CURRENT1.60AMPSMAX OCPD RATING20 AMPSMAX. PANEL/CIRCUIT10SHORT CIRCUIT CURRENT15 AMPSPV MODULE RATING @ STCMANUFACTURERSUNPOWERSPR-M425-H-AC-415OUTPUT POWER415WPOWER TOLERANCE+5/-0%MODULE EFFICIENCY22.00%TEMP. COEF. (POWER)-0.29% / °CSUZANNE STAUDUHAR 4725 Bayside Rd Orono, MN 55359 AHJ: HENNEPIN COUNTY UTILITY: WRIGHT HENNEPIN UTILITY METER #342674200 L1L2NGL2L2L1L1L2L2L1L1GNSURGE PROTECTIONDEVICE MNSPD-300-AC20A20A20ANEW ENPHASE COMBINER 4MONITORING DEVICE 240V, NEMA 3R 1PHASEEXISITING UTILITY METER1-PHASE, 3W 120V/240V234NEW UTILITY ACDISCONNECT SWITCHSQUARE D 240V/60AFUSED NEMA3R D222NRBREFERENCE POINTOF APPLICABILITYVISIBLE-OPEN LOCKABLEREADILY ACCESSIBLEEXISTING 240V/200ABUSBAR RATING, SERVICEPANEL SINGLE PHASEWITH 100A DISCONNECTEXISTING GROUNDINGELECTRODE SYSTEMNEW JUNCTION BOX600V,NEMA 4 UL LISTED1POINT OF INTERCONNECTIONSUPPLY SIDE TAP(IT350 POLARIS LUGS)NEW GROUNDINGELECTRODE SYSTEM200AMMNEW PVCTAP BOXNEW UTILITY EXPORTMETER MILBANK U4801-XL-TG-KK 1-PHASE3-WIRE 120/240V#6 AWG COPPERGROUND<10'5IQ GATEWAYCONSUMPTION CTPORDUCTION CT40AFUSES18 SUNPOWER SPR-M415-H-AC (415W)(L/W/H) 73.7"/40.6"/1.57"18 ENPHASE IQ7HS-66-M-US. INVERTERS TO BE MOUNTED ON THERAIL BENEATH EACH OF THE PANELSCONDUCTOR SCHEDULESPECIFIED CONDUCTORS SHALL BE COPPER UNLESS OTHERWISE SPECIFIEDTAG #DESCRIPTIONWIRE GAUGE# OF CONDUCTORS/COLORCONDUIT TYPECONDUIT SIZE1INVERTER OUTPUT (TRUNK CABLE)12 AWG6(3L1, 3L2)FREE AIRN/AEGC(BARE COPPER GROUND6 AWG1 BARE2INVERTER OUTPUT (THWN-2)12 AWG6(3L1, 3L2)FMC3/4"EGC(THWN-2)12 AWG1(GRN)3INVERTER OUTPUT(THWN)6 AWG3(L1,L2,N) B/R/WSCH 80 PVC1"EGC(THWN)10 AWG1(GRN)4INVERTER OUTPUT(THWN)6 AWG3(L1,L2,N) B/R/WSCH 80 PVC1"5INVERTER OUTPUT(THWN)4/0 AWG AL3(L1,L2,N) B/R/WSCH 80 PVC2"INVERTER ENPHASEIQ7HS9 MICRO-INVERTERS IN BRANCH CIRCUIT #19 MICRO-INVERTERS IN BRANCH CIRCUIT #2TERMINATOR CAP ON THELAST CABLE CONNERTOR (TYP)GN Sheet NumberWOLF RIVER ELECTRIC101 ISANTI PARKWAY NE,SUITE G ISANTI, MN 55040ELECTRICAL LICENSE:EA777669Contact: (763) 229-6662contact@wolfriverelectric.comSheet NumberDESIGNED BY:WOLF RIVERELECTRICRevisions TableDescriptionDateRev.Sheet Name &Creation DateEngineer Signature & StampBuilding License :BC773271Designer SignatureD-2.2Serviced by Wolf River ElectricContact: (763) 229-6662NPLACARDSHEET01/24/2025CAUTION ! MULTIPLE SOURCES OF POWERPOWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITHDISCONNECTS LOCATED AS SHOWNFOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN MAINSERVICE PANEL UTILITY METERUTILITY ACDISCONNECTUTILITY EXPORTMETERBAYSIDE ROADSUZANNE STAUDUHAR 4725 Bayside Rd Orono, MN 55359 AHJ: HENNEPIN COUNTY UTILITY: WRIGHT HENNEPIN UTILITY METER #342674200 LABEL LOCATION: RSD INITIATION DEVICE, AC DISCONNECTPER CODE: NEC 690.56(C)(2)ELECTRICAL SHOCK HAZARDWARNINGLABEL LOCATION: COMBINER PANEL, ACDISCONNECT, POINT OF INTERCONNECTIONPER CODE: NEC 706.15(C)(4), NEC 690.13(B)LABEL LOCATION: MAIN SERVICE DISCONNECT, UTILITY METERPER CODE: NEC 690.13(B)LABEL LOCATION: COMBINER PANEL(S), MAIN SERVICE DISCONNECTPER CODE: NEC 110.27(C), OSHA 1910.145(f)(7)LABEL LOCATION: AC DISCONNECTPER CODE: NEC 690.13(B)LABEL LOCATION: MAIN SERVICE DISCONNECTPER CODE: NEC 690.56(C)!LABEL LOCATION: DC CONDUIT/RACEWAYSPER CODE: NEC 690.31(D)(2)LABEL LOCATION: AC DISCONNECT/POINT OF INTERCONNECTIONPER CODE: NEC 690.54DO NOT DISCONNECTUNDER LOADLABEL LOCATION: MAIN SERVICE DISCONNECTPER CODE: NEC 690.15(B) & NEC 690.33(D)(2)DUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEMWARNINGLABEL LOCATION: MAIN SERVICE DISCONNECT, PRODUCTION/NET METERPER CODE: NEC 690.59, 705.12(C)!PHOTOVOLTAICAC DISCONNECTPHOTOVOLTAIC SYSTEM AC DISCONNECTRATED AC OUPUT CURRENT: 28.8 ANOMINAL OPERATING AC VOLTAGE: 240 VSOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNSOLAR ELECTRICPV PANELSTURN RAPID SHUTDOWNSWITCH TO THE"OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCESHOCK HAZARDIN THE ARRAYMAIN PHOTOVOLTAICSYSTEM DISCONNECTRAPID SHUTDOWN FORSOLAR PV SYSTEMTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONTURN OFF PHOTOVOLTAIC ACDISCONNECT IOR TOWORKING INSIDE PANELWARNING!PHOTOVOLTAIC POWER SOURCEWARNINGSHEETUTILITYSheet NumberWOLF RIVER ELECTRIC101 ISANTI PARKWAY NE,SUITE G ISANTI, MN 55040ELECTRICAL LICENSE:EA777669Contact: (763) 229-6662contact@wolfriverelectric.comSheet NumberDESIGNED BY:WOLF RIVERELECTRICRevisions TableDescriptionDateRev.Sheet Name &Creation DateEngineer Signature & StampBuilding License :BC773271Designer SignatureD-2.3D-2.3D-2.301/24/2025SUZANNE STAUDUHAR 4725 Bayside Rd Orono, MN 55359 AHJ: HENNEPIN COUNTY UTILITY: WRIGHT HENNEPIN UTILITY METER #342674200 Model No. MNSPD-115 MNSPD-300-AC MNSPD-300-DC MNSPD-600 Max Operating Voltage 100 VAC/150VDC 300VAC 385VDC 480VAC/600VDC Surge Current per Phase 80kA 80kA 80kA 80kA Configuration 1 O, 3-wire (2 Legs) 1 O, 3-wire (2 Legs) 1 O, 3-wire (2 Legs) 1 O, 3-wire (2 Legs) MCOV 180V L-N 470V L-N 470V L-N 780V L-N SCCR 10kA 10kA 10kA 10kA VPR 600V/3kA L_G 600V 1200V 1200V 1800V O3.527” 4.425”3.82” 24” Wires O 2” ires Performance Surge Current Rating per Phase 80kA Short Circuit Current Rating 10kA Fusing Individually fused MOVs Thermal Fusing Yes Over current Fusing Yes Operating Frequency 0 to 500 Hz Mechanical Description Enclosure Polycarbonate UL94V-0 Environmental Rating Type 4X Connection Method #12 AWG Weight 1 lb. Mounting Method 1/2” Conduit Knockout Operating Altitude Sea Level – 12,000’ (3,658 Meters) Storage Temp -40o F to +185o F (-40o C to +85o C) Operating Temp -40o F to +185o F (-40o C to +85o C) Diagnostics Blue status LED, one per leg Listings and Performance UL Standard for Safety, UL 1449 Surge Protective Devices-Fourth Edition CSA C22.2 No. 8-M1986 Electromangetic Interference (EMI) Filters, Fourth Edition Diagnostic Blue LED Thermal Disconnector Internal Fuse Response Time <1 micro sec. MNSPD-115 0 to 90 VAC 0 to 115 VDC 180V 600V Up to 90VAC circuits, 12V, 24V, 48VDC battery circuits UL1449 4th Ed. Type 1 MNSPD-300-AC 0 to 250 VAC 470V 1200V 120/240 VAC circuits UL1449 4th Ed. Type 1 MNSPD-300-DC 0 to 300 VDC 470V 1200V Off-grid PV combiners Charge controller inputs up to 300VDC UL1449 4th Ed. Type 1 MNSPD-600 0 to 480 VAC 0 to 600 VDC 780V 1800V 316V/480 VAC circuits Grid-tie PV combiners Grid-tie inverter input Non-Isolated Inverters UL1449 4th Ed. Type 1 PART NUMBER Nominal Voltage MCOV VPR Line to Ground Suggested Placement Type MNSPD-300-AC LED indicates when voltage is present between L1 + ground and L2 + ground MNSPD-115, MNSPD-300-DC and MNSPD-600: LED indicates when voltage is present between L1 + L2 (PV+ PV-) www.midnitesolar.com/spd 19115 - 62nd Ave NE, Arlington, WA 98223 PH. 360-403-7207 FAX 360-691-6862 MidNite Surge Protection DevicesMidNite Surge Protec tion Devices 425-410 W Residential Black AC Module SunPower® Maxeon® Technology Built specifically for use with the SunPower Equinox® system, the only fully integrated solution designed, engineered, and warranted by one company. Highest Power Density Available The patented, solid-copper foundation Maxeon Gen 6 cell is over 5% larger than prior generations, delivering the highest-efficiency all-black AC solar module available.1 Highest Lifetime Energy and Savings Designed to deliver 60% more energy over 25 years in real-world conditions like partial shade and high temperatures.2 Best Reliability, Best Warranty With more than 42.6 million and 15 GW of modules deployed around the world, SunPower technology is proven to last. That’s why we stand behind our module and microinverter with the industry’s best 25-year Combined Power and Product Warranty, including the highest Power Warranty in solar. Datasheet 0510 15 20 25 150% 140% 130% 120% 110% 100% 90% 80% 70% 60%25-year Energy Yield per WattYears of Operation Up to 60% More Lifetime Energy Conventional Panel M-Series Part of the SunPower Equinox® Solar System • Seamless aesthetics • Compatible with mySunPower monitoring Factory-integrated Microinverter • Highest-power integrated AC module in solar • Engineered and calibrated by SunPower for SunPower AC modules 6.37 in[161.7 mm]6.54 in[166 mm]5% larger need blk image 1 Based on datasheet review of websites of top 20 manufacturers per IHS, as of July 2021. 2 Maxeon 435 W, 22.5% efficient, compared to a Conventional Panel on same-sized arrays (300 W, 19% efficient, approx. 1.6 m²), 7.9% more energy per watt (based on PVSyst pan files for avg. US climate), 0.5%/yr slower degradation rate (Jordan, et. al. “Robust PV Degradation Methodology and Application.”PVSC 2018). 3 Based on search of datasheet values from websites of top 10 manufacturers per IHS, as of June 2021. 4 Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. 5 Factory set to IEEE 1547a-2014 default settings. CA Rule 21 default settings profile set during commissioning. 6 Standard Test Conditions (1000 W/m² irradiance, AM 1.5, 25°C). All DC voltage is fully contained within the module. 7 UL Listed as PVRSE and conforms with NEC 2014 and NEC 2017 690.12; and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors; when installed according to manufacturer’s instructions. 8 Please read the safety and installation instructions for more information regarding load ratings and mounting configurations. See www.sunpower.com/company for more reference information. For more details, see extended datasheet: www.sunpower.com/solar-resources. Specifications included in this datasheet are subject to change without notice. ©2022 SunPower Corporation. All rights reserved. SUNPOWER, the SUNPOWER logo and EQUINOX are registered trademarks of SunPower Corporation in the U.S. MAXEON is a registered trademark of Maxeon Solar Technologies, Ltd. For more information visit www.maxeon.com/legal. AC Electrical Data Inverter Model: Type H (Enphase IQ7HS)@240 VAC @208 VAC Max. Continuous Output Power (VA)384 369 Nom. (L–L) Voltage/Range3 (V)240 / 211–264 208 / 183–229 Max. Continuous Output Current (A)1.60 1.77 Max. Units per 20 A (L–L) Branch Circuit4 10 9 CEC Weighted Efficiency 97.0%96.5% Nom. Frequency 60 Hz 60 Hz Extended Frequency Range 47–68 Hz 47–68 Hz AC Short Circuit Fault Current Over 3 Cycles 4.82 A 4.82 A Overvoltage Class AC Port III III AC Port Backfeed Current 18 mA 18 mA Power Factor Setting 1.0 1.0 Power Factor (adjustable)0.85 (inductive) / 0.85 (capacitive)0.85 (inductive) / 0.85 (capacitive) DC Power Data SPR-M425-BLK-H-AC SPR-M415-BLK-H-AC SPR-M410-BLK-H-AC Nom. Power⁶ (Pnom) W 425 415 410 Power Tolerance +5/−0%+5/−0%+5/−0% Module Efficiency 22.0%21.5%21.2% Temp. Coef. (Power)−0.29% / °C −0.29% / °C −0.29% / °C Shade Tolerance Integrated module-level max. power point tracking Tested Operating Conditions Operating Temp.−40° F to +185° F (−40° C to +85° C) Max. Ambient Temp.122° F (50° C) Max. Test Load⁸Wind: 125 psf, 6000 Pa, 611 kg/m² back Snow: 187 psf, 9000 Pa, 917 kg/m² front Max. Design Load Wind: 75 psf, 3600 Pa, 367 kg/m² back Snow: 125 psf, 5400 Pa, 550 kg/m² front Impact Resistance 1 inch (25 mm) diameter hail at 52 mph (23 m/s) Mechanical Data Solar Cells 66 Maxeon Gen 6 Front Glass High-transmission tempered glass with anti-reflective coating Environmental Rating Outdoor rated Frame Class 1 black anodized (highest AAMA rating) Weight 48 lbs (21.8 kg) Recommended Max. Module Spacing 1.3 in. (33 mm) Warranties, Certifications, and Compliance Warranties • 25-year limited power warranty • 25-year limited product warranty Certifications and Compliance • UL 1741 / IEEE-1547 • UL 1741 AC Module • UL 61730 (Type 2 fire rated) • UL 62109-1 / IEC 62109-2 • FCC Part 15 Class B • ICES-0003 Class B • CAN/CSA-C22.2 NO. 107.1-01 • CA Rule 21 (UL 1741 SA)⁵ (includes Volt/Var and Reactive Power Priority) • UL Listed PV Rapid Shutdown Equipment⁷ Enables installation in accordance with: • NEC 690.6 (AC module) • NEC 690.12 Rapid Shutdown (inside and outside the array) • NEC 690.15 AC Connectors, 690.33(A)–(E)(1) When used with AC module Q Cables and accessories (UL 6703 and UL 2238)⁷ • Rated for load break disconnect PID Test 1000 V: IEC 62804 Packaging Configuration Modules per pallet 25 Packaging box dimensions 75.4 × 42.2 × 48.0 in. (1915 × 1072 × 1220 mm) Pallet gross weight 1300 lb (590 kg) Pallets per container 32 Net weight per container 18,880 kg M425-BLK | M415-BLK | M410-BLK SunPower Residential Black AC Module 1-800-SUNPOWER | sunpower.com 544400 RevA January 2022 Please read the safety and installation instructions for details. © 2024 Enphase Energy. All rights reserved. Enphase, the e and CC logos, IQ, and certain other marks listed at enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the U.S. and other countries. Data subject to change.DSH-00562-1.0-EN-US-2024-08-02 IQ7HS Microinverter The high-powered, smart grid-ready IQ7HS Microinverter with integrated MC4 connectors dramatically simplifies installation while achieving the highest system efficiency. Easy to install • Lightweight and simple • Faster installation with improved, lighter two-wire cabling • Built-in rapid shutdown compliant (NEC 2014 , 2017, 2020, and 2023) Productive and reliable • Optimized for high powered 60-cell/120-half-cut-cell, 66-cell/ 132-half-cut-cell, and 72-cell/ 144-half-cut-cell PV modules • More than a million hours of testing • Class II double-insulated enclosure • UL Listed Smart grid-ready • Complies with advanced grid support, voltage, and frequency ride-through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) and IEEE 1547:2018 (UL 1741-SB, 3rd Ed.) for single-phase systems Part of the Enphase Energy System, the IQ7HS Microinverters integrate with the IQ Gateway, IQ Battery, and the Enphase Installer App monitoring and analysis software. IQ7HS Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power- on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Connect PV modules quickly and easily to the IQ7HS Microinverters that have integrated MC4 connectors. IQ7HS Microinverters are UL Listed as PV rapid shutdown equipment and conform with various regulations when installed according to the manufacturer’s instructions. DATA SHEET DSH-00562-1.0-EN-US-2024-08-02 1 Pairing PV modules with wattage above the limit may result in additional clipping losses. See the compatibility calculator at enphase.com/installers/microinverters/calculator. 2 Nominal voltage range can be extended beyond nominal if required by the utility. 3 Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. IQ7HS Microinverter INPUT DATA (DC)UNITS IQ7HS-66-M-US Commonly used module pairings1 W 320–460 Module compatibility —60-cell/120-half-cut-cell, 66-cell/132-half-cut-cell, and 72-cell/144-half-cut-cell PV modules Maximum input DC voltage V 59 Peak power tracking voltage V 38–43 Operating range V 20–59 Minimum/Maximum start voltage V 30/59 Maximum input DC short-circuit current A 25 Maximum module Isc A 20 Overvoltage class DC port —II DC port back-feed current A 0 PV array configuration —1 × 1 ungrounded array; no additional DC side protection required; AC side protection requires max. 20 A per branch circuit OUTPUT DATA (AC) Peak output power VA 384 @ 240 VAC, 369 @ 208 VAC Maximum continuous output power VA 384 @ 240 VAC, 369 @ 208 VAC Nominal (L-L) voltage/Range2 V 240/211–264, 208/183–229 Maximum continuous output current —1.60 A (240 V), 1.77 A (208 V) Nominal frequency Hz 60 Extended frequency range Hz 47–68 AC short-circuit fault current over three cycles Arms 4.82 Maximum units per 20 A (L-L) branch circuit3 —10 (240 VAC), 9 (208 VAC) Overvoltage class AC port —III AC port back-feed current mA 18 Power factor setting —1.0 Power factor (adjustable)—0.85 leading ... 0.85 lagging EFFICIENCY CEC weighted efficiency %97.0 @ 240 V, 96.5 @ 208 V MECHANICAL DATA Ambient temperature range °C (°F)–40 to 60 (–40 to 140) Relative humidity range %4 to 100 (condensing) DC connector type —Stäubli MC4 Dimensions (H × W × D)mm (in)212 (8.3) × 175 (6.9) × 30.2 (1.2) without bracket Weight kg (lb)1.1 (2.4) Cooling —Natural convection—no fans Approved for wet locations —Yes Pollution degree —PD3 DSH-00562-1.0-EN-US-2024-08-02 FEATURES Communication Power line communication (PLC) Monitoring Enphase Installer App and monitoring options Compatible with IQ Gateway Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect means required by NEC 690 and C22.1-2018 Rule 64-220. Compliance CA Rule 21 (UL 1741-SA), IEEE 1547:2018 (UL 1741-SB 3rd Ed.) for single-phase systems HEI Rule 14H SRD 2.0 UL 62109-1, FCC Part 15 Class B, ICES-0003 Class B CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 rapid shutdown of PV systems for AC and DC conductors, when installed according to manufacturer’s instructions. MECHANICAL DATA Enclosure —Class II double-insulated, corrosion-resistant polymeric enclosure Environmental category/UV exposure rating —NEMA type 6/Outdoor DSH-00562-1.0-EN-US-2024-08-02 Revision history REVISION DATE DESCRIPTION DSH-00562-1.0 August 2024 Initial release. © 2024 Enphase Energy. All rights reserved. Enphase, the e and CC logos, IQ, and certain other marks listed at enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the U.S. and other countries. Data subject to change. IQC-4-4C-DSH-00217-3.0-EN-US-2024-08-16 DATA SHEET IQ Combiner 4/4C The Enphase IQ Combiner 4/4C with IQ Gateway and integrated LTE-M1 cell modem (included only with IQ Combiner 4C) consolidates interconnection equipment into a single enclosure and streamlines IQ Microinverters and storage installations by providing a consistent, pre-wired solution for residential applications. It offers up to four 2-pole input circuits and an Eaton BR series busbar assembly. Smart • Includes IQ Gateway for communication and control • Includes Enphase Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05), included only with IQ Combiner 4C • Includes solar shield to match IQ Battery aesthetics and deflect heat • Flexible networking supports Wi-Fi, Ethernet, or cellular • Optional AC receptacle available for PLC bridge • Provides production metering and consumption monitoring Simple • Centered mounting brackets support single stud mounting • Supports bottom, back and side conduit entry • Up to four 2-pole branch circuits for 240 VAC plug-in breakers (not included) • 80 A total PV or storage branch circuits Reliable • Durable NRTL-certified NEMA type 3R enclosure • Five-year limited warranty • Two-years labor reimbursement program coverage included for both the IQ Combiner SKU’s • UL Listed • X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C comply with IEEE 1547:2018 (UL 1741-SB, 3rd Ed.) © 2024 Enphase Energy. All rights reserved. Enphase, the e and CC logos, IQ, and certain other marks listed at https://enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the U.S. and other countries. Data subject to change. X-IQ-AM1-240-4 X2-IQ-AM1-240-4 (IEEE 1547:2018) X-IQ-AM1-240-4C X2-IQ-AM1-240-4C (IEEE 1547:2018) *Refer to the https://enphase.com/installers/resources/warranty page for country-specific warranty information. IQ Series Microinverters The high-powered smart grid-ready IQ Series Microinverters (IQ6, IQ7, and IQ8 Series) dramatically simplify the installation process. IQ System Controller 2 Provides microgrid interconnection device (MID) functionality by automatically detecting grid failures and seamlessly transitioning the home energy system from grid power to backup power. IQ Load Controller Helps prioritize essential appliances during a grid outage to optimize energy consumption and prolong battery life. IQ Battery All-in-one AC coupled storage system that is reliable, smart, simple, and safe. It provides backup capability, and installers can quickly design the right system size to meet the needs of both new and retrofit solar customers. 5-year limited warranty IQC-4-4C-DSH-00217-3.0-EN-US-2024-08-16 IQ Combiner 4/4C MODEL NUMBER UNITS DESCRIPTION IQ Combiner 4 (X-IQ-AM1-240-4, X2-IQ-AM1-240-4) — IQ Combiner 4 with an IQ Gateway printed circuit board for integrated revenue-grade PV production metering (ANSI C12.20 ±0.5%) and consumption monitoring (±2.5%). Includes a silver solar shield to match the IQ Battery and IQ System Controller 2 and to deflect heat. IQ Combiner 4C (X-IQ-AM1-240-4C, X2-IQ-AM1-240-4C)— IQ Combiner 4C with an IQ Gateway printed circuit board for integrated revenue-grade PV production metering (ANSI C12.20 ±0.5%) and consumption monitoring (±2.5%). Includes Enphase Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05), a plug-and-play industrial-grade cell modem for systems up to 60 microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, where there is adequate cellular service in the installation area). Includes a silver solar shield to match the IQ Battery and IQ System Controller 2 and to deflect heat. WHAT’S IN THE BOX UNITS IQ Gateway printed circuit board —IQ Gateway is the platform for total energy management for comprehensive, remote maintenance, and management of the Enphase Energy System. Busbar —80 A busbar with support for one IQ Gateway breaker and four 20 A breakers for installing IQ Series Microinverters and IQ Battery IQ Gateway breaker A Circuit breaker, 2-pole, 10/15 Production CT —Pre-wired revenue-grade solid-core CT, accurate up to ±0.5% Consumption CT —Two consumption metering split core or clamp-type CTs, shipped with the box, accurate up to ±2.5% Emphase Mobile Connect (only with IQ Combiner 4C)—4G-based LTE-M1 cellular modem (CELLMODEM-M1-06-SP-05) with a five-year T-Mobile data plan MICROINVERTERS, ACCESSORIES AND REPLACEMENT PARTS (not included; order separately) UNITS Supported microinverters —IQ6, IQ7, and IQ8. Do not mix IQ6/IQ7 Microinverters with IQ8 Enphase Communications Kit COMMS-CELLMODEM-M1-06 CELLMODEM-M1-06-SP-05 CELLMODEM-M1-06-AT-05 — - Includes COMMS-KIT-01 and CELLMODEM-M1-06-SP-05 with a 5-year T-Mobile data plan for Enphase sites - 4G-based LTE-M1 cellular modem with a five-year T-Mobile data plan - 4G-based LTE-M1 cellular modem with a five-year AT&T data plan Circuit breakers (off-the-shelf) — Supports Eaton BR2xx, Siemens Q2xx and GE/ABB THQL21xx Series breakers (xx may be 10, 15, 20, 30, 40, 50, or 60). Supports Eaton BR220B, BR230B, and BR240B circuit breakers compatible with hold-down kit. Circuit breakers (provided by Enphase)—BRK-10A-2-240V, BRK-15A-2-240V, BRK-20A-2P-240V, BRK-15A-2P-240V-B, and BRK-20A-2P-240V-B XA-SOLARSHIELD-ES —Replacement solar shield for IQ Combiner 4/4C XA-ENV2-PCBA-4 —IQ Gateway replacement printed circuit board (PCB) for IQ Combiner 4/4C XA-PLUG-120-3 —Accessory receptacle for power line carrier in IQ Combiner 4/4C (required for EPLC-01) X-IQ-NA-HD-125A —Hold-down kit for Eaton circuit breaker with screws ELECTRICAL SPECIFICATIONS UNITS Rating A 80 System voltage and frequency —120/240 VAC, 120/208 VAC, 60 Hz Busbar rating A 125 Fault current rating kAIC 10 Maximum continuous current rating (input from PV/storage)A 64 Maximum fuse/Circuit rating (output)A 90 Branch circuits (solar and storage)—Up to four 2-pole Eaton BR, Siemens Q, or GE/ABB THQL Series distributed generation (DG) breakers only (not included) Maximum total branch circuit breaker rating (input)A 80 A of distributed generation/95 A with IQ Gateway breaker included To learn more about Enphase offerings, visit enphase.com. IQC-4-4C-DSH-00217-3.0-EN-US-2024-08-16 COMMUNICATION INTERFACES UNITS DESCRIPTION Integrated Wi-Fi —802.11b/g/n (dual band 2.4 GHz/5 GHz) for connecting the Enphase Cloud through the internet Wi-Fi range (recommended)m (ft)10 (32.8) Ethernet —Optional 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included) for connecting to the Enphase Cloud through the internet Digital I/O —Digital input/output for grid operator control USB 2.0 —For Mobile Connect, Communications Kit 1 for IQ Battery 3/3T/10/10T, Communication Kit 2 for IQ Battery 5P Access point (AP) mode —For connection between the IQ Gateway and a mobile device running the Enphase Installer App Metering ports —Up to two Consumption CTs, one IQ Battery CT, and one Production CT Power line communication kHz 90–110 Web API — See https://developer-v4.enphase.com Local API —See Guide for local API Cellular/Mobile Connect — CELLMODEM-M1-06-SP-05, CELLMODEM-M1-06-AT-05 (4G-based LTE-M1 cellular modem). Note that an Enphase Mobile Connect cellular modem is required for all installations with Enphase IQ Batteries and/or IQ System Controllers COMPLIANCE IQ Combiner with IQ Gateway CA Rule 21 (UL 1741-SA) IEEE 1547:2018 - UL 1741-SB, 3rd Ed. (X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C) CAN/CSA C22.2 No. 107.1, 47 CFR, Part 15, Class B, ICES 003, NOM-208-SCFI-2016 Production metering: ANSI C12.20 accuracy class 0.5 (PV production), UL 61010-1, CAN/CSA 22.2 No. 61010-1, IEEE 2030.5/CSIP Compliant COMPATIBILITY PV Microinverters IQ6, IQ7, and IQ8 Series Microinverters COMMS-KIT-01 IQ System Controller EP200G101-M240US00 IQ System Controller 2 EP200G101-M240US01 IQ Battery ENCHARGE-3-1P-NA, ENCHARGE-10-1P-NA, ENCHARGE-3T-1P-NA, ENCHARGE-10T-1P-NA COMMS-KIT-021 IQ System Controller 3 SC200D111C240US01, SC200G111C240US01 IQ Battery IQBATTERY-5P-1P-NA MECHANICAL DATA UNITS DESCRIPTION Dimensions (W × H × D)cm (in)37.5 × 49.5 × 16.8 (14.75 × 19.5 × 6.63). Height is 53.5 (21.06) with mounting brackets Weight kg (lb)7.5 (16.5) Ambient temperature range °C (°F)-40 to 46 (-40 to 115) Cooling —Natural convection plus a heat shield Enclosure environmental rating —Outdoor, NRTL-certified, NEMA type 3R, polycarbonate construction Wire sizes — • 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors • 60 A breaker branch input: 4 to 1/0 AWG copper conductors • Main lug combined output: 10 to 2/0 AWG copper conductors • Neutral and ground: 14 to 1/0 copper conductors Always follow local code requirements for conductor sizing Altitude m (ft)Up to 2,600 (8,530) 1 For information about IQ Combiner 4/4C compatibility with the 3rd-generation batteries, refer to the compatibility matrix. ELECTRICAL SPECIFICATIONS UNITS IQ Gateway breaker A 10 A or 15 A rating GE/Siemens/Eaton included Production metering CT A 200 A solid core pre-installed and wired to IQ Gateway Consumption monitoring CT (CT-200-SPLIT/CT- 200-CLAMP)A A pair of 200 A split core or clamp-type current transformers IQC-4-4C-DSH-00217-3.0-EN-US-2024-08-16 Revision history REVISION DATE DESCRIPTION DSH-00217-3.0 August 2024 Updated the system voltage value. Updated Sprint plan to T-Mobile data plan. DSH-00217-2.0 April 2024 Updated the UL smart mark. DSH-00217-1.0 February 2024 Initial release. Previous releases. © 2024 Enphase Energy. All rights reserved. Enphase, the e and CC logos, IQ, and certain other marks listed at https://enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the U.S. and other countries. Data subject to change. SunPower® InvisiMount™ | Residential Mounting System Simple and Fast Installation • Integrated module-to-rail grounding • Pre-assembled mid and end clamps • Levitating mid clamp for easy placement • Mid clamp width facilitates even module spacing • Simple, pre-drilled rail splice • UL 2703 Listed integrated grounding Flexible Design • Addresses nearly all sloped residential roofs • Design in landscape and portrait • Rails enable easy obstacle management Customer-Preferred Aesthetics • #1 module and #1 mounting aesthetics • Best-in-class system aesthetics • Premium, low-profile design • Black anodized components • Hidden mid clamps and end clamps hardware, and capped, flush rails Part of Superior System • Built for use with SunPower DC and AC modules • Best-in-class system reliability and aesthetics • Combine with SunPower modules and monitoring app sunpower.com Elegant Simplicity SunPower® InvisiMount™ is a SunPower-designed rail-based mounting system. The InvisiMount system addresses residential sloped roofs and combines faster installation time, design flexibility, and superior aesthetics. The InvisiMount product was specifically envisioned and engineered to pair with SunPower modules. The resulting system-level approach will amplify the aesthetic and installation benefits for both homeowners and installers. SunPower® InvisiMount™ | Residential Mounting System InvisiMount Component Details Component Material Weight Mid Clamp Black oxide stainless steel AISI 304 63 g (2.2 oz) End Clamp Black anodized aluminum alloy 6063-T6 110 g (3.88 oz) Rail Black anodized aluminum alloy 6005-T6 830 g/m (9 oz/ft) Rail Splice Aluminum alloy 6005-T5 830 g/m (9 oz/ft) Ground Lug Assembly 304 stainless (A2-70 bolt; tin-plated copper lug)106.5 g/m (3.75 oz) End Cap Black acetal (POM) copolymer 10.4 g (0.37 oz) Roof Attachment Hardware Supported by InvisiMount System Design Tool Application • Composition Shingle Rafter Attachment • Composition Shingle Roof Decking Attachment • Curved and Flat Tile Roof Attachment • Universal Interface for Other Roof Attachments InvisiMount Operating Conditions Temperature −40° C to 90° C (−40° F to 194° F) Max. Load 2400 Pa uplift 5400 Pa downforce Roof Attachment Hardware Warranties Refer to roof attachment hardware manufacturer’s documentation InvisiMount Warranties And Certifications Warranties 25-year product warranty 5-year finish warranty Certifications UL 2703 Listed Class A fire rating when distance between roof surface and bottom of SunPower module frame is ≤ 3.5” *Module frame that is compatible with the InvisiMount system required for hardware interoperability. © 2015 SunPower Corporation. All Rights Reserved. SUNPOWER, the SUNPOWER logo, and INVISIMOUNT are trademarks or registered trademarks of SunPower Corporation. All other trademarks are the property of their respective owners. Specifications included in this datasheet are subject to change without notice. InvisiMount Component Images Module* / Mid Clamp and Rail Mid Clamp End Clamp Rail & Rail Splice Ground Lug Assembly End Cap Module* / End Clamp and Rail sunpower.com Document #509506 Rev B The extra-large L-foot and proprietary lag screw result in larger spans between mounts Larger Spans Manufactured with advanced materials and coatings to outlast the roof itself 25-Year Warranty Fully IBC/CBC Code Compliant Exceeds ASCE 7-16 Standards FL Cert of Approval FL41396 UL2703 Certified Code Compliant The proprietary non-hardening sealant will flex and reseal over years of thermal expansion and contraction Self-Healing Pegasus Solar Inc | 506 West Ohio Avenue, Richmond, CA 94804 | www.pegasussolar.com Effortless Lifetime Roof Protection The non-hardening sealant completely fills any missed pilot holes, shingle rips, voids, or other potential water ingress points under the entire footprint of the 4.6” wide base. Before InstaFlash Installed:Sealant is contained above roof surface by a protective cage. After InstaFlash Installed:Sealant is compressed to fill all holes and voids. Factory-installed, non-hardening sealant Prevents sealant from getting on hands or roof. Collapses upon lag installation. Protective Cage Never Deal With Caulking Again! 1 Drill pilot hole in the center of the rafterusing a 7/32” bit. 2 Place the InstaFlash over the pilot hole. Note: the direction of the InstaFlash Down arrows should point down the roof. 4Drive the lag until the InstaFlash is fully seated to the roof. 3 Insert the lag screw through the center hole into the pilot hole. Pegasus Solar Inc | 506 West Ohio Avenue, Richmond, CA 94804 | www.pegasussolar.com PIF-RB0 PIF-RBDT PIF-RBSH PIF-RM0 PIF-RMDT Finish Kit Contents Black InstaFlash, 5/16” x 4.0” SS Lag Black InstaFlash, 5/16” x 4.0” SS Lag, Dovetail T-bolt w/ Nut Black InstaFlash, 5/16” x 4.0” SS Lag, M10 Hex Bolt w/ Nut Mill Insta-Flash, 5/16” x 4.0” SS Lag Mill InstaFlash, 5/16” x 4.0” SS Lag, Dovetail T-bolt w/ Nut Attachment Type Rafter Attached Roof Type Sealant Application Factory Installed Installation Temperature Cure Time Service Temperature Certifications Install Application Kit Quantity 24 Boxes per Pallet 36 SPECIFICATIONS INSTAFLASH KITS Black Mill US Patents Pending. All rights reserved. ©2023 Pegasus Solar Inc. IBC, ASCE/SEI 7-16, FL Cert of Approval FL41396, TAS 100(A), UL2703 Instantly Waterproof; Non-hardening 0°F to 170° F -40°F to 195° F Most Railed Systems, Pegasus Tilt Leg Kit Sloped Roof: Composition Shingle, Rolled Asphalt | Flat roof: Modified Bitumen Roof, Built-Up Roof SCAN FOR INSTALLATION VIDEO SCAN FOR FREE TRIAL Milbank Manufacturing | 4801 Deramus Ave., Kansas City, MO 64120 | 877.483.5314 | milbankworks.com Please consult serving utility for their requirements prior to ordering or installing, as specifications and approvals vary by utility and may require local electrical inspector approval. All installations must be installed by a licensed electrician and must comply with all national and local codes, laws and regulations. Milbank reserves the right to make changes in specifications and features shown without notice or obligation. Catalog Number U4801-XL-5T9 Marketing Product Description 5 Terminal Ringless Small Closing Plate Lever Bypass 5th Terminal 9 Oclock Position UPC 784572288218 Length (IN)4.844 Width (IN)13 Height (IN)19 Brand Name Milbank Type Ringless Meter Socket Application Meter Socket Standard UL Listed;Type 3R Voltage Rating 600 Volts Alternating Current Amperage Rating 200 Continuous Ampere Phase 1 Phase Frequency Rating 60 Hertz Size 4.844L x 13W x 19H Number Of Cutouts 0 Cutout Size No Main Breaker Cable Entry Overhead or Underground Terminal Lay in Insulation Glass Polyester Mounting Surface Mount Enclosure G90 Galvanized Steel with Powder Coat Finish Jaw Quantity 5 Terminal Bypass Type Lever Bypass Number of Meter Positions 1 Position Equipment Ground Bonded Ground Strap Hub Opening Small Closing Plate Line Side Wire Range 6 AWG - 350 kcmil Load Side Wire Range 6 AWG - 350 kcmil Number Of Receptacles 0 U4801-XL-5T9 1092206 11625 PROSPEROUS DRIVE ODESSA, FL 33556 FIGURE 1IT FIGURE 4ITO FIGURE 2DUAL ENTRY CONTACT NSi FOR SALES @ 800.321.5847 FIGURE 3ITH NOTES:1. CONNECTOR MANUFACTURED FROM 6061-T6 ALUMINUM ALLOY.2. UL LISTED PER UL486A/B SPECIFICATIONS FOR 600V.3. DUAL RATED FOR 90 C COPPER AND/OR ALUMINUM CONDUCTOR.4. COLD TEMPERATURE RATED TO -45 C.5. HIGH DIELECTRIC STRENGTH INSULATION IS ABRASION, CHEMICAL AND UV RESISTANT. *NOT UL LISTED tt 600 SERIES ARE AL7CU AND 75 C PART #FIG. #WIRE RANGE HEX SIZE L W H IT4 1 4 - 14 SLOTTED 1.12 1.18 1.38 ITO4 4 4 - 14 SLOTTED 1.12 1.25 1.38 IT1/0 1 1/0 - 14 3/16 1.62 1.62 1.75 ITO1/0 4 1/0 - 14 3/16 1.62 1.75 1.75 IT3/0 1 3/0 - 6 1/4 1.84 1.75 1.87 ITO3/0 4 3/0 - 6 1/4 1.84 1.87 1.87 IT250 2 250 - 6 5/16 2.12 2.25 2.25 IT350 2 350 - 6 5/16 2.47 2.50 2.44 IT500 2 500 - 4 5/16 2.81 2.87 2.94 IT750*2 750 - 250 3/8 3.48 3.50 3.50 IT600tt 2 600 - 6 5/16 2.34 2.94 3.05 ITH750 3 750 - 250 5/16 3.48 4.50 3.50 DWG. NO. TITLE: PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF POLARIS SALES CO. INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF POLARIS SALES CO. INC. IS PROHIBITED. IT SERIESINSULATEDCONNECTORS SALES A CO A INCPOLARIS IT SERIES SHEET: 1 OF 1NOT TO SCALE DATE DRAWN BY N/AMATERIAL: S.PARRY 6/13/2012 NAME