HomeMy WebLinkAbout1986-07-29 On Site Sewage Treatment Inspection ReportONSITE SEWAGE TREATMENT
INSPECTION REPORT
OWNER
-/ ' I 1116 &wI5:i_L_
PERMIT NO.'S.
Oil jibe, .\mtb .Sbon, oJ.
Lake 1llimetonka
CITY
OF POST OFFICE BOX 66
O _ O O 1335 S. Brown Rd.
Crystal Bay, MN 55323
473.7357
---- -- ADDRESS d /Sfl C'",4 1) S"' —
DATES -
CONTRACTORS "O'ECN
City Ordinance No. 210 requires that each on-site sewage treatment system in Orono he inspected on a regular basis. The on-site sewage
treatment system at the above address has been inspected and appears to fall into the category checked below.
(This is 1 an existing system U new construction)
1 Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating
properly.
LJ 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to he designed,
u located, and constructed generally in accordance with previous codes. System appears to be functioning properly, no major
upgrading of the system is required at this time.
03 Does not meet current City standards in many respects relating to design, construction, or I-tcation. Appears to be operating
adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at
this time.
M4 System may or may not meet current City standards for design, construction or location, but is failing to properly treat and
dispose of the current input, and is endangering a water supply, or is a source of pollution to surface or groundwaters, or is
creating a safety hazard, or is otherwise creating a public nuisance. Please contact the City Inspector to discuss system repair/
replacement procedures. If drainfield replacement is necessary, sod testing will usually be required, and a design and site plan
must be submitted for review. Your contractor must obtain a permit before work is started.
SYSTEM CONDITION ( m Checked items may require your action)
Tank inspection indicates:
-4D Pumpout not needed at this time.
❑ Solids accumulation in tanks indicates they should Tie pump-
ed out this year to help prevent future problems.
❑ Solids accumulation in tanks is at a critical level. Tanks
should be pumped out as soon as possible.
❑ System is discharging to surface. Tanks must be pumped
within 48 hours to eliminate surface discharge.
❑ Inspection risers missing—tanks could not be inspected.
Inspection risers (4" dia. pipe) must be installed in each tank
at next purr.pout. If tanks have not been pumped out within
the last three years, they should be pumped out now.
SITE CHARACTERISTICS
Limiting Site Factors
Cl Slope
❑ Soil
❑ High water table
❑ Lot sire
-0 Lake, wetland, or stream
❑ Drainage
COMMENTS
F] Inspection pipe is located directly over tank baffle. (Does not
give accurate measurement of solids accumulation.) If tanks
have not been pumped out within the last three years, they
should be pumped out now.
Drainfield inspection indicates
1-Q Drainfield is dry, no surfacing evident.
❑ Some evidence of surfacing, not critical yet.
❑ Drainfield is saturated and visibly discharging untreated
effluent to the surface. This condition may require replace-
ment or additions to dramrield. ;ontact the City Inspector
immediately, Repairs must be completed within 90 days.
❑ Drainfield extent and condition unknown.
Potential for System Failure
Site Capabilities for
(depends on sod types, water
Future Expansion
table, and system condition)
❑ Adequate
❑ Low
---:1 Farr
Medium
❑ Poor
l-] High
❑ Inadequate
C ] System is causing visible
surface discharge.
/9 Cf -------
Date of Inspection Septic System Inspector
Note In the event that this inspe.ction report is used to satisfv the requirements for a mortgage or other transfer of property be advised that
this report (toes not guarantee or certify that an existing system will continue to function property, but is merely an opinion of the adego-.y
of the system under current conditions based on the available information.
This report rnust be kept on the premises with system location and pumping records
WHITE COPY ' Inspector's File GOLD COPY / Homeowner