HomeMy WebLinkAbout1989-03-21 On Site Sewage Treatment Inspection ReportOrr for North Sbore o f
l.ake ,41innetonka
ON-SITE SEWAGE TREATMENT
INSPECTION REPORT POST OFFICE BOX 66
1335 S. Brown Rd.
Crystal Bay, MN 55323
473-7357
OWNER ___-�CoTT 57 w7&) . —_-__ ADDRESS 35 7S ClteetSTlNC; iy�
PERMIT W_i. DATES - 3 _2 ( — g9 CONTRACTORS fAVdFt
City Urtimance No. 210 requires that each onsite sewage treatment system in Orono be inspected on a regular basis. The onsite sewage
treatment system at the above address has been in ted and appears to fall into the category checked below.
ITh,, s i I an existing system new construction)
I Meets or exceeds current City standards :n all respects relating to design, construction, and location. Appears to be operating
properly.
2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed,
located, and constructed generally in accordance with previous codes. System appears to be functioning properly; no major
upgrading of the system is required at this time
❑ 3 Does not meet current City standards in many respects relating to design, construction, of location. Appears to be operating
adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at
this time.
4 System :nay of may not meet current City standards for design, construction or location, but is failing to properly treat and
dispose of the current input, and is endangering a water supply, or is a source of pollution to surface or groundwaters, or is
creating a safety hazard, or is otherwise creating a public nuisance. Please contact the City Inspector to discuss system repair/
replacement procedures. It drainfield replacement is necessary, soil testing will usually be required, and a design and site plan
must be submitted for review. Your contractor must obtain a permit before work is started.
SYSTEM CONDITION 1 Ia Checked items may require your action)
Tank spection indicates
Pumpout not needed at this time,
❑ Solids accumulation in tanks indicates they should be purnp•
ed out this year to help prevent future problems.
❑ Solids accumulation in tanks is at a critical level. Tanks
should be pumped out as soon as possible.
❑ System is discharging to surface. Tanks roust be pumped
within 48 hours to eliminate surface d charge.
❑ Inspection risers missing—tanks could not be inspected.
Inspection risers 14" dia. pipe) must be installed in each tank
at next pumpout. If tanks have not been pumped out within
the last three years, they should he pumped out now.
l..l Insilection pipe is located directly over tank baffie. (Does not
orve accurate measurement of solids accumulation.) If tanks
have not been pumped out within the last three years, they
should be pumped out now.
Drain ld inspection indicates
rainfield is dry, no surfacing evident.
❑ Some evidence of surfacing, not critical yet.
❑ Drainfield :s saturated and visibly discharging untreated
effluent to the surface. This condition may require replace-
ment or additions to dramfield. Contact the City Inspector
immediately. Repairs must be completed within 90 days,
11 Drainfield extent and condition unknown.
SITE CHARACTERISTICS
Limiting Sate Factors
Potential for System Failure
Site Capabilities for
❑ slope
(depends on soil types, water
Future Expansion
❑ Soil
WHrgh water table
table, and system condition)
X.Low
F1 Adequate
av
❑lot site
Ll Medium
7 Poor
❑ Lake, wetland, or stream
❑ High
I 1 Inadequate
❑ Drainage
❑ System is causing visible
surface discharge.
COMMENTS
Atr'rdCµe-0 /NFv�2n�,a�►�lcaN�v�Yput� F/LcS - - - - -- -
/3 �yc� 0^�- --- - —
Date of Inspection Septic System Inspector
Nate. In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that
this report does not guarantee or certify that an t-isting system will continue to function property, but is merely an opinion of the adequacy
of the system under current conditions based on the available information.
This report must be kept on the premises with system location and pumping records.
WHITE COPY f Inspector's Fife GOLD COPY I Homeowner