0
\ _ kesKo4i`i
ON—SITE SEWAGE TREATMENT
INSPECTION REPORT
Owner: ��/f/✓l�%I� Address: YTa;!S7 �1�1r�.,,� zil,
Permit U 8: Dates: S` "%,g1 Contractors:
City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is 44 an existing system [ I new construction)
111FORMITY (1-3):
"CODE SYSTEM" -A system which meets all the location, design, and construction standards of the current City
Codes, and r•r�ch is operating satisfactorily by treating and disposing of the entire current sewage input
without discoarging any pollutants into ground or surface waters.
"CONFORMING SYSTEM" -A system which does not meet all the location, design, and construction standards of the
current City Codes, but was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface waters.
"NON -CONFORMING SYSTEM" -A prohibited system; asystem located within a designated 100 -year floodplain; any
system which may or may not meet all the location, design, and construction standards of the current City
Codes and which is failln for any reason; and any system with less than 3 feet of unsaturated soil or send
between the distribution for
and the limiting soil characteristics.
(The limiting soil characteristic [ I has or P1 has not been identified at this time. If the limiting soil
characteristic has not been identified, this classification may be subject to revision.)
TANK CONDITION (5-10): �]
Tank inspection indicates:
5 Pulpout not needed at this time.
Solids accumulation in tanks indicates theyshould be pupped out this year to help prevent future problems.
Solids accumulation in tanks is at a critical leve,
. aT nks should be pumped out as soon as possible.
8 System is discharging to the surface. Tanks must be pumped out within 4C hours to eliminate surface discharge.
each
9 Inspection risers missing -tanks could not be inspected. Inspection risers (4" die. pipe) must be installed In
tank at next purrpout. if tanks have not been pumped out within the last three years, they should be pumped
out now.
10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of sods accumulation).
If tanks have not been =Out within the last three years, they should be pumped
Drainfield inspection indicates:
11 Drainfield is dry, no surfacing evident.
Some evidence of surfacing, not critical yet.
Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately. Repairs must be coalGl 01thin
14 Drainfield extent arta condition ism nono .
LIMITING SITE FACTORS SL set
POTENTIAL FOR SYSTEM FAILURE (depends on soils water table,etc.):
COMMENTS:
Date of Inspection
Note: In the event that this inspection report is used to
property, be advised that this report does not guarantee
properly, but is merely an opinion of the adequacy of
information.
c System Inspector
satisfy the requirements for a mortgage or other transfer of
or certify that an existing system will continue to funct or
the system under current conditions based on the avar'ab!^
This report must be kept on the premises with the system location air cxmv'"1 'ecord%.
WHITE COPY Inspectors File YELLOW COPY Homeowner