Loading...
HomeMy WebLinkAbout1981-06-18 On Site Sewage Treatment Inspection ReportON SITE SEWAGE TREATMENT INSPECTION REPORT i I OMONC.^ Oil the North Sbon of Lake Minnetonka POST OFFICE BOX 66 1335 S. Brown Rd. Crystal Bay, MN 56323 473-7357 OWNER. PHONE. >^014 aJ StdjO'/ . PERMIT NO’S. -ADDRESS ^*7% ---------------------------------- DATES_____________ City Ordinanca No. 210 raquires that each orvsite sewage treatment system in Orono be inspected on a regular basis. The on-sIte sewage treatment system at the above address has been inspected and appears to fall Into the category checked below: □ l "02 □ 3 □ 4 Meeu or exceeds current city standards in all respects relating to design, consUuction. and location. Appears to be operating properly. Does not meet current city stendards in some respects relating to design, construction, or location. Appears to be operating properly. Does not meet current city standerds in many respectt relating to design, construction, or location. Appears to be operating adequately. Does not meet current city standards of design, construction or location, is being overused, or is failing to properly treat and dispose of the current input and is therefore endangering a water supply, is a source of pollution to surface or groundwaters, it creating a safety hazard, or it otherwise creating a public nuisance. Please contact the inspector to discuss requirements for repairs to your system. Soil testing may be re­ quired. In ail casts a design and site plan must be submitted for review. Your contractor must obtain a permit before work it started. WORK REQUIRED: n Septic tanks mutt be pumped within 48 hours. r~| Drainfield mutt be repaired or replaced within 90 days. r~l Inspection riser |4" diam. pipe) mutt be installed in each tank. P~| Tank inspection indicates maintenance pumpout It needed as toon at possible. City ordinance requires that tanks be pumped out every three years. ^ SITE CHARACTERISTICS: Limiting Site Factors □ Slope □ Soil □High water table □ Lot size £Q.ake, wetland, or stream □Drainage Potential for System Failure (depends on toil types, water table, and system condition) □ Low □ Medium □ High □ System It causing visible surface discharge. Site Capabilities for Future Expansion □ Adequate □ Fair □ Poor □ Inadequate COMMENTS:.PtgVtSF CALL /vfg~ re Loc4T7e3A^ Or S&PTtC 7~A/<il^S ^ - /g-rS/ Data of Inspection Septic System Insp^^r Tbit report must be kept on the premises with system location and pumping records. WHITE COPY / Inspector's File GOLD COPY / Homeowner