HomeMy WebLinkAbout1987-09-23 On Site Sewage Treatment Inspection ReportON SITE SEWAGE TREATMENT
INSPECTION REPORT
On the North Shore of
lake Minnetonka
•: I T »
I
: ) M ■' ) N
POST OFFICE BOX 66
1335 S. Brown Rd.
Crystal Bay, MN 55323
473-7357
OWNER
PERMIT • S.SN/o020i^
___ ADDRESS
DATES -2-t 8*^
(Ze>At, SpMrtU-
/CONTRACTORS ^AaegW-iamAy^i_srAC>
Ciiy Ordinancs No. 210 requires that each on-site sewage treatment system in Orono be inipectad on a regular batft* The on-site sewage
treatment system at the above addreu has been inspected and appears to fall %t^\o the category checked below.
(This is □ an existino system □new construction)
□*
fall mto the category checked below.
fa^C ctf»»M£r'JT “ s ySTVvw-an existing system
Meets or exceeds current City standards in aSI respects relating to design, construction, and location. Appears to be operating
properly.
□ 3
Does not meet all current City standards for new construction (1978 Codei but in most respects appears to be desigrsed.
located, and constructed generally m accordance with previous codes. System appears to be functioning properly; no major
upgrading of the system is required at this time.
Does not meet current City standards in many respects relating to design, construction, or location. Appears to be operating
adequately at this time, bui has a relatively high potential for future problems. No major upgrading of system is required at
this time.
□ 4 System may or may not meet current City standards lor design, construction or location, but is failing to properly treat and
dispose of the current input, and is endangering a water supply, or is a source of pollution to surface or groundwaters, or is
creating a safety hazard, or is otherwise creating a public nuisance. Please contact the City Inspector to discuss system repair/
replacement procedures. If drainfield replacement is necessary, soil testing wiil usually be required, and a design and site plan
must be submitted for review. Your contractor must obtain a permit before work is started.
S ystem condition ( Q checked items may require your action)
TanMnspection indicates:
^l^ympout not needed at this time.
D Solids accumulation in tanks indicates they should be pump*
ed out this year to help prevent future problems.
D Solids accumulation in tanks is at a critical level. Tanks
should be pumped out as soon as possible.
D System is discharging to surface. Tanks must be pumped
Within 48 hours to eliminate surface discharge.
□ Inspection risers missing-tanks could not be inspected.
Inspection risers (4** die. pipe) must be installed in each tank
at next pumpout. If tanks have not been pumped out within
the last three years, they should be pumped out now.
□ Inspection pipe is located directly over tank baffle. (Does not
give accurate measurement of solids accumulation.) If tanks
have not been pumped out within the last three yeart. they
should be pumped out now.
Drainfjeld inspection indicates
BkOrainfield is dry. no surfacing evident.
□ Some evidence of surfacing, not critical yet.
□ Drainfield is saturated and visibly ditchargirsg untreated
effluent to the surface. This condition may require replace
ment or additions to drainfield. Contact the City Inspector
immediately. Repairs must be completed within 90 days.
□ Drainfield extent and condition unknown.
SITE CHARACTERISTICS
Limiting Site Factorsniting
0 Slope
□ Soil
□ High water table
□ Lot size
y® Lake, wetland, or stream
□ Drainage^
Fotential for System Failure
(depends on soil types, water
tablg, and system condition)
yfli^Low
G Medium
□ High
n System is causing visible
Site Capabilities for
Future Expansion
□ Adequate
SBTFair
□ Poor
□ Inadequate
surface discharge. ^
COMMENTS
Date of Inspection Septic System Inspector
Note In the event that this inspection report is used to satisfy the requirements foi a mortgage or other transfer of property, be aovised that
this report does not guarantee or teitify that an e*istiiTg sys»r»m vyiM continue to function properly, but is merely an opinion of the adequacy
of the systnm under current coricjitions based on the available mloimaiion.
This resMirt must be Ketit on the prrwnises with system locaTion and pumping lecOiCfl.
WHITE COPY / Inspector s Fila GOLD COPY / Homeowner