HomeMy WebLinkAbout1990-07-13 On Site Sewage Treatment Inspection ReportCON SITE SEWAGE TREATMENT
INSPECTION REPORT
On the SoTtb Shore of
Lake Miuttetoaka
POST OFFICE BOX 66
1335 S. Brown Rd.
Crystal Bay. MN 55323
473 7357
OWNER
PERMIT NO.'S.
/fl. ^wLk.------------------ ADDRESS J^oi ^3/
DATES ------------------ CONTRACTORS
132
City Ordinance No. 210 requ»re« that cacti onsite scwaQe treatment lystern in Orono be inspected on a regular basis. The on^te sewage
treatment system at the above addren has been inspected and appears to fail into the category checked below.
(This is an existing system □ new construction)
P") y Meets Of exceeds current City standards in att respects relating to design, construction, and tocation. Appears to be operating
' properly.
Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed,
located, and constr jcted generally in accordance with previous codes. System appears to be functioning properly; no major
upgrading of the lys em is required at this time.
Does not meet curr ;nt City standards in many respects relating to design, construction, or location. Appears to be operating
adequately at this >me. but has a relatively high potential for future probJems. No major upgrading of system is required at
this time.
System may or may not meet i urrent City standards for design, construction or location, but is failing to property treat and
dispose of the current input, and »s endangering a water supply, or is a source of pollution to surface or groundwaters, or is
creating a safety hazard, or is otherwise creating a public nuisance. Please contact the City Inspector to discuss system repair/
replacement procedures. If drainfield replacement is necessary, soil testing wiU usually be required, and a ctesign and site plan
must be submitted for review. Your contractor must obtain a permit before work is started.
SYSTEM CONDITION ( (Z Checked items may require your action)
Tank inspection indicates;
□ Pumpout not needed at this time.
G Solids accumulation in tanks indicates they should be pump
ed out this year to help prevent future problems.
D Solids accumulation in tanks is at a critical level. Tanks
should be pumped out as soon as possible.
G System is discharging to surface. Tanks must be pumped
. within 48 hours to eliminate surface discharge.
—y** Of Inspection risers missing-tanks could not be inspected.
Inspection risers (4" dia. pipe) must be installed in each tank
at next pumpout. If tanks have not been pumped out within
the last three years, they should be pumped out now.
Q Inspection pipe is located directly over tank baffle. (Does not
give accurate measurement of solids accumulation.) If tanks
have not been pumped out within the last three years, they
should be pumped out now.
Drainfield inspection indicates:
B Drainfield is dry, no surfacing evident.
Q Some evidence of surfacing, not critical yet.
G Drainfield is saturated and visibly discharging untreated
effluent to the surface. This condition may require replace-
ment or additions to drainfield. Contact the City Inspector
immediately. Repairs must be completed within 90 days,
Q Drainfield extent and condition unknown.
SITE CHARACTERISTICS:
Limiting Site Factors
G Slope
G Soil
G High water table
G Lot size
G Lake, wetland, or stream
G Drainage
COMMENTS:
Potential for System Failure
(depends on soil types, water
table, and system condition)
^ Low
□ Medium
Q High
G System is causing visible
surface ducharge. . |
jLr /r\ (Ta ionk.Jr\
I.^r)d.r^i^€y ijkir
’zJt/yJa/Ae. £)U/nt\ 1^/^J.
Site Capabilities for
Future Expansion
M Adequate
O Fair
□ Poor
G Inadequate
pLVnt\ /VJu J. .
S^itic System InspectorDate of Inspection
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that
this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy
of the system under current conditions based on the available information.
This rejiort must be kept jn the premises with system location and pumping records.
WHITE COPY / Inspector's File GOLD COPY / Homeowner