Loading...
HomeMy WebLinkAbout1994-04-18 On Site Sewage Treatment Inspection ReportCCITY OF OIIOIIO Hynfe*p»l Office Pott Office io* 66 Crystet ftii SSS23*t^66 oT OH>SXXK SCWJkCK nKAXMER zMsrecTioM kepokt Ownert.Sana. Permit #*o»m Address!' Dates!.9-/-/<<: y^y Pd. ly<//Tar/ ContractorsI City ordinance nuitjer 100 requiret that each on tite tCMfe treatment system in Orono be inspected on a rwlar basis. The on-site sewage treatment system at the above address has been inspected and appears to fail into the category checked below. {This is C>i^an existing system ( J new construction) ■iUJ»STSTEm cohropsiir •COOE SYSUS'’** system which meets all the location* design* and construction standards of the current City Codes* and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. •COKfOPHIllG SYSTW'-A system which does net meet all the location, design, and construction standards of the current City Codes* but was installed according to the code in effect at the time of installation* and which is operating satisfactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. "WOK-COhrORPIliC SY$TE«**-A prohibited system; a system located within a designated tCO-year floodplain; vrf system which may or may net meet all the location* design* and construction standards of the current City Codes and which is failing for any reason; and ffnv swstam with^ less than I feet of unsaturated soil or sand between the distribution device and the limiting soil characterisfTcs. (The limiting soil characteristic f characteristic has not been identified* has or I ] has not been identified at this classification may be subject to revision.) It this time.^ If the limitiilimiting soil TAhK CONDinoa Tank inspection indicates: 5 Pumpout not needed at this time.6 Solids accunulation in tanks indicates they should be ptnped out this year to help prevent future problems. 7 Solids accunulation in tanks is at a critical level. Tanks should be purrped out as socyi as possible. System is discharging to the surface. Tanks must be purped out within 48 hours to eliminate surface discharge. (y Insoectioo risers missing*tanks could not be inspected. ^nsDfiCtion risers <4« die. pipe) must be installed iiInspection risers missing*tanks could not be tank at neat piinpout. If tanks have not out noil. Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accmulation). installed ttrey "sh i^id be n each located directly tanks have not been pumped out within the last three years, they should be pumped out now. OkAthFIElD COWDITIOW (11-14)i OrMnfield inspection im Qjp Orainfiefd Is dry, 12 Some evidence of st indicates: no surfacing evident, surfacing* not critical yet. Drainfield is saturated and visibly discharging untreated effluent iiTinediately. Repairs must be completed within 90 days, 14 Drainfield extent and condition unknown. to the surface. Contact the City Inspector LIWITIMG SITE FACTORS (slope.setbacks/et^riV^yj^y^^^^ _ _ _ _ POTENTIAL FOR SYSTEH fAILURE (depends on soils.water table.etc.): ro)f k:COMMENTS Inspection tern inspeciSystem inspector F' ;r# Ki?i. a mortgage an existing system will continue Note: In the event that this inspection report is used to satisfy the requirements property, be advised that this report does not guarantee or certify that * ' , but is merely an opinion of the adequacy of the system under current conditions based ion. This report must be kept on the premises with the system location and pumping records. WHITE COPY Inspectors File YELLOW COPY Homeowner Other transfer of to function on the available