HomeMy WebLinkAbout3520 North Shore Dr. Point of Sale Inspection-Compliancy Expires 7-11-2034TASK 85412 Date Called in 6/24/2024
t`��'O Date Scheduled 6/27/2023 1:00 M
City Of Orono Inspected after repairs 7/11/2024
�e Point of Sale Sanitary Sewer Service I&I Compliance Inspection Form
Property Address:
1 3520 North Shore Dr.
PID:
10811723430009
Owner Information
Name:
Lexie Polk
Mailing Address:
(if different from
Property)
Phone:
21 &851-8923
Email:
lexiepolkmn@gmail.com
Inspector Information
Name:
Company/ Organization
License number:
Phone.
Email:
Inspection
System
Standard
Pass
Fail
Roof Drains
Roof drains and leaders Roof drains should not be connected to the sanitary
X
sewer but should discharge to the ground outside of a building. If the roof
drains are connected to the sanitary sewer, disconnect them, plug any open
connections to the sanitary sewer using a non -shrink permanent material, and
redirect the roof drains onto the ground outside the building.
Foundation
Foundation drains are underground pipes that collect storm water from
X
Drains
around the base of a building and into a sump basket, where it is then
pumped outside of the building. Foundation drains should not be connected
to the sanitary sewer.
Sump Pumps
Sump pumps are designed to capture surface or ground water that enters
X
basements or crawl spaces and pump it away from the house. The basic sump
system includes drain tile, a sump pit, a sump pump, a float or switch, and a
drain line. Sump pumps should not be connected to the sanitary sewer.
Sewer Service
Sanitary Sewer Inflow & Infiltration (I/I) Comp Iiance.Inspection Sanitary
X
Line PSewer
Lines. All sanitary sewer lines serving Property, from the house to the
main line, shall be in a safe and functional condition and shall be free from all
leaks, failures including but not limited to partially collapsed sections or tree
root intrusion. The sanitary sewer lines shall meet the City Code standards and
specifications. (Details on back of this sheet)
Notes:
Ouverson did 25' CIPP repair 4" towards home and 55' of 4" CIPP
and 10' of 6" CIPP to main.
40' of 4" PVC repair with 2 ferncos.
Inspected by Scott O 7/11/2024
Toilet Removed
o Yes o No
For Ins ection:
Inspectors Signature: Date:
Owners Signature: Date:
City
Review
� Com liant
❑ Corrective Action Re uired
Certificate of Compliance Expires:
Corrective Action Due by:
Date:
7/11/2024
Signature:
Name:Kellie Hoen