- PROPERTY INFORMATION
Location: 80 Luce Line Ridge
Maple Plain
Tax ID:311-182-334001
Use: Residential, Single Family
GENERAL SYSTEM TYPE: Multi Flo 2x yr W/ TEST
Fold
Here
Inspected: 0411912024 - Inspection Type: ROUTINE - Correction Status: No corrections needed
Company: Work Performed By: Submitted 0412212024 by:
Septic Check Kyle Wade Heather Johnson
COMMENTS & GENERAL INSPECTION NOTES
No Deficiencies Noted
Verified that everything is functioning properly.
In order to monitor flow data and track water usage, it is recommended to add an elapsed time meter (ETM) or a cycle counter. This will also assist
n identifying any potential issues. Please inform us if you would like us to install an ETM during the next visit.
No pumping is currently necessary.
GENERAL SITE & SYSTEM CONDITIONS
The General Site and Svstem Conditions were: Fullv Inspected
Components accessible for service: YES
All required service performed (if no - specify omitted inspection items in notes): YES
Surfacing effluent from any component (including mound seepage): NO
Components appear to be watertight - no visual leaks: YES
Improper encroachment (structures/impervious surfaces); cover; or settling problems observed: NO
ONSITE SEWAGE SYSTEM INSPECTION DETAIL
TANK: Septic Tank - 1 Compartment 000 Gal Trash Trap
This component was:
Fully Inspected
Effluent level within operational limits (if NO explain in comments):
YES
All required baffles in place (N/A= No baffles required):
YES
Compartment 1 Scum accumulation (Inches, if other specify):
1
Compartment 1 Sludge accumulation (Inches, if other specify):
S
,Pumpinq recommended:
TANK. Septic Tank - I Compartment 000 Gal Septic Tank w1pump
NO
This component was:
Fully Inspected
Effluent level within operational limits if NO explain in comments):
YES
All required baffles in place N/A= No baffles required):
YES
Compartment 1 Scum accumulation Inches, if other specify):
o
Compartment 1 Sludge accumulation Inches, if others ecif :
1
Pumping recommended:
Pump: Effluent . Dose To Multi -Flo
Na
This component was:
Fully Inspected
Controls functioning:
YES
Tested gallons per minute flow:
ReportlD: 1280773 View inspection reports online at www.onlinerme.com Page 1 of 2
Manufacturer: Consolidated Treatment Svstems Model: Multi -Flo FTP-0.6
This component was:
Fully Inspected
Unit alarms functioning:
YES
Aerobic Mechanism appears to be functioning per manufacturers specifications:
YES
Impeller assembly removed and cleaned:
NO
Previous signs of foaming overflow noted on Weir Plate:
NO
Filter Socks cleaned:
YES
Filter Socks were partially changed out:
NO
Filter Socks were completely changed out:
NO
Gaskets on Sure Bowl need replacing:
NO
Digester settleable solids test resulted in greater than 40% settleable solids: (If Yes, pumping needed)
NO
Pum in needed:
TANK: Septic Tank - 1 Compartment 1000 Gal Dose Tank
NO
This component was:
Fully Inspected
Effluent level within operational limits if NO explain in comments):
YES
All required baffles in place N/A= No baffles required):
YES
Compartment 1 Scum accumulation Inches, if otherspecify):
0
Compartment 1 Sludge accumulation Inches, if others ecif :
0
Pumping recommended:
Pump: Effluent . Dose Pump
NO
This component was:
Fully Inspected
Controls functioning:
YES
Tested allons er minute flow:
PumpsPanel: Control - 2 This component was:
Fully Inspected
Panel functioning (including alarm):
YES
Pump 1: on minutes override in parentheses - if present):
20 sec
Pump 1: off hours override in parentheses - if present):
30 min
Pump 1: gallons per dose override in parentheses - if present):
Pump 1: ETM hours override in parentheses - if present):
Pump 1: Cycle Count override in parentheses - if present):
Pump 2: on minutes override in parentheses - if present):
Pump 2: off hours override in parentheses - if present):
Pump 2: gallons per dose override in parentheses - if present):
Pump 2: ETM hours override in parentheses - if present):
NA
Pump 2: Cycle Count override in parentheses - if present :
Drainfield (disposal): Pressure Bed Drainfield
NA
This component was:
Fully Inspected
Lateral lines flushed:
NO
Average squirt height ifperformed) feet, if otherspecify):
Ponding present? If YES explain in comments:
NO
This report indicates certain characteristics of the onsite sewage system at the time of visit. In no way is this report a guarantee of operation or future performance.