HomeMy WebLinkAbout04/19/2024 septicSeptic Check 6074 Keystone Rd Milaca, MN 56353 Mall To: Katarina Grajcar 80 Luce Line Ridge Maple Plain, MN Fold Here 320-983-2447 Fax:320-983-2151 - PROPERTY INFORMATION Location: 80 Luce Line Ridge Maple Plain Tax ID:311-182-334001 Use: Residential, Single Family GENERAL SYSTEM TYPE: Multi Flo 2x yr W/ TEST Fold Here Inspected: 0411912024 - Inspection Type: ROUTINE - Correction Status: No corrections needed Company: Work Performed By: Submitted 0412212024 by: Septic Check Kyle Wade Heather Johnson COMMENTS & GENERAL INSPECTION NOTES No Deficiencies Noted Verified that everything is functioning properly. In order to monitor flow data and track water usage, it is recommended to add an elapsed time meter (ETM) or a cycle counter. This will also assist n identifying any potential issues. Please inform us if you would like us to install an ETM during the next visit. No pumping is currently necessary. GENERAL SITE & SYSTEM CONDITIONS The General Site and Svstem Conditions were: Fullv Inspected Components accessible for service: YES All required service performed (if no - specify omitted inspection items in notes): YES Surfacing effluent from any component (including mound seepage): NO Components appear to be watertight - no visual leaks: YES Improper encroachment (structures/impervious surfaces); cover; or settling problems observed: NO ONSITE SEWAGE SYSTEM INSPECTION DETAIL TANK: Septic Tank - 1 Compartment 000 Gal Trash Trap This component was: Fully Inspected Effluent level within operational limits (if NO explain in comments): YES All required baffles in place (N/A= No baffles required): YES Compartment 1 Scum accumulation (Inches, if other specify): 1 Compartment 1 Sludge accumulation (Inches, if other specify): S ,Pumpinq recommended: TANK. Septic Tank - I Compartment 000 Gal Septic Tank w1pump NO This component was: Fully Inspected Effluent level within operational limits if NO explain in comments): YES All required baffles in place N/A= No baffles required): YES Compartment 1 Scum accumulation Inches, if other specify): o Compartment 1 Sludge accumulation Inches, if others ecif : 1 Pumping recommended: Pump: Effluent . Dose To Multi -Flo Na This component was: Fully Inspected Controls functioning: YES Tested gallons per minute flow: ReportlD: 1280773 View inspection reports online at www.onlinerme.com Page 1 of 2 Manufacturer: Consolidated Treatment Svstems Model: Multi -Flo FTP-0.6 This component was: Fully Inspected Unit alarms functioning: YES Aerobic Mechanism appears to be functioning per manufacturers specifications: YES Impeller assembly removed and cleaned: NO Previous signs of foaming overflow noted on Weir Plate: NO Filter Socks cleaned: YES Filter Socks were partially changed out: NO Filter Socks were completely changed out: NO Gaskets on Sure Bowl need replacing: NO Digester settleable solids test resulted in greater than 40% settleable solids: (If Yes, pumping needed) NO Pum in needed: TANK: Septic Tank - 1 Compartment 1000 Gal Dose Tank NO This component was: Fully Inspected Effluent level within operational limits if NO explain in comments): YES All required baffles in place N/A= No baffles required): YES Compartment 1 Scum accumulation Inches, if otherspecify): 0 Compartment 1 Sludge accumulation Inches, if others ecif : 0 Pumping recommended: Pump: Effluent . Dose Pump NO This component was: Fully Inspected Controls functioning: YES Tested allons er minute flow: PumpsPanel: Control - 2 This component was: Fully Inspected Panel functioning (including alarm): YES Pump 1: on minutes override in parentheses - if present): 20 sec Pump 1: off hours override in parentheses - if present): 30 min Pump 1: gallons per dose override in parentheses - if present): Pump 1: ETM hours override in parentheses - if present): Pump 1: Cycle Count override in parentheses - if present): Pump 2: on minutes override in parentheses - if present): Pump 2: off hours override in parentheses - if present): Pump 2: gallons per dose override in parentheses - if present): Pump 2: ETM hours override in parentheses - if present): NA Pump 2: Cycle Count override in parentheses - if present : Drainfield (disposal): Pressure Bed Drainfield NA This component was: Fully Inspected Lateral lines flushed: NO Average squirt height ifperformed) feet, if otherspecify): Ponding present? If YES explain in comments: NO This report indicates certain characteristics of the onsite sewage system at the time of visit. In no way is this report a guarantee of operation or future performance. ReportlD: 1280773 View inspection reports online at www.onlinerme.com Page 2 of 2