Loading...
HomeMy WebLinkAboutFA23-00013-Sprinkler10/18/23, 10:23 AM Letter View file:///C:/Users/jruthenberg/Downloads/Inspection Report Individual (18).htm 1/1 From:gnelson@oronomn.gov Sent:07/20/2023 - 02:28 PM To:jason@fssmidwest.com CC:gnelson@oronomn.gov Subject:Inspection Report Individual CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952) 249-4616 Inspection Report 2430 North Blossom CIR Permit Number:FA23-000013 Site Address:2430 North Blossom CIR, Orono, MN 55356 Property Owner: Description:NFPA 13D FIRE SPRINKLER SYSTEM NEW TOWNHOME Inspection Date: 07/20/2023 Inspection Type: Fire Sprinkler Rough In Inspection Results: Inspection Passed: Proceed Sincerely, Gary Nelson 952-242-4442 To schedule your inspections please call: (952) 249-4600 CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY! 10/18/23, 10:24 AM Inspection Details | Citizenserve https://www5.citizenserve.com/Admin/ActivityController?ActionType=FindActivityForUpdate&ActivityID=52192255&DepartmentID=4563&WorkOrder_I…1/1 PERMIT PROJECT FILE #: 23-000686 2430 NORTH BLOSSOM CIR ORONO MN 55356 NFPA 13D FIRE SPRINKLER SYSTEM NEW TOWNHOME  INSPECTION INFORMATION Department Community Development Inspection Type Fire Sprinkler Final   Assign To James VanEyll Permit #: FA23-000013 NFPA 13D FIRE SPRINKLE... Created On 09/05/2023 by James VanEyll Notes DATES Date 09/05/2023    From 10: 00  AM To 10: 30  AM Completion Date 09/05/2023 Status Inspection Passed: Proceed Is Vegetation Established #STATUS COMMENTS  INSPECTION COMMENTS   Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model F3QR56 Dry K5.6 (80 metric) Quick-Response, Standard Spray Sprinklers Bulletin 157 April 2020Bulletin 157 April 2020 Features 1. Available in the following configurations: • Pendent with standard escutcheon • Pendent with Model HB extended escutcheon • Pendent with Model FP recessed escutcheon • Pendent with Model F1 recessed escutcheon • Concealed Pendent with Model CCP cover plate • Horizontal Sidewall with Standard escutcheon • Horizontal Sidewall with Model HB extended es- cutcheon • Horizontal Sidewall with Model FP recessed es- cutcheon (FM Standard Response) • Horizontal Sidewall with Model F1 recessed es- cutcheon (FM Standard Response) • Upright 2. Available with 1” NPT, ISO7-1R1, 3/4” NPT, or ISO7- 1R3/4 inlet fitting. 3. 3/4” NPT inlet fittings permit replacement of older 3/4” inlet dry sprinklers without changing to a larger sprin- kler fitting. 4. Sprinklers, escutcheons, and cover plates are avail- able in a wide variety of standard and special appli- cation finishes. 5. White polyester, black polyester, and Electroless Nickel PTFE (ENT) finish sprinklers are cULus Listed as Corrosion Resistant. 6. Available with cULus Listed 250 psi (17.2 bar) pres- sure rating for Dry Pendent and select HSW configu- rations. FM Approved for 175 psi (12 bar). Product Description Model F3QR56 Dry sprinklers are quick-response, stan- dard coverage sprinklers with a nominal K-Factor of 5.6 (80 metric). Available in Dry Pendent, Dry Horizontal Sidewall, and Dry Upright configurations, Model F3QR56 Dry sprin- klers all use a 3 mm glass bulb operating element. See the Temperature Ratings table in this Bulletin for available tem- perature ratings. Model F3QR56 Dry sprinklers are intended for installation on wet-pipe, dry-pipe, or preaction sprinkler systems in accordance with NFPA 13, FM Property Loss Prevention Data Sheets, and other applicable installation standards. Model F3QR56 Dry Pendent and Sidewall sprinklers are available with a variety of escutcheon options as illustrated in Figs. 1 through 3 and Figs. 5 through 9. In addition, Model F3QR56 Dry Pendent sprinklers are also available with the Model CCP conical concealed cover plate as illustrated in Fig. 4. Available sprinkler, escutcheon, and cover plate fin- ishes are identified in the Finishes table in this Bulletin. The Model F1 escutcheon, Model FP escutcheon, and Model CCP cover plate are the only recessed escutcheons and cover plate listed for use with Model F3QR56 Dry sprinklers; the use of any other recessed escutcheon or cover plate Concealed (See Fig. 4) Recessed FP Pendent (See Fig. 3) Recessed F1 Horizontal Sidewall (See Fig. 9) Horizontal Sidewall (See Fig. 6) Pendent (See Fig. 1) Recessed F1 Pendent (See Fig. 5) Recessed FP Horizontal Sidewall (See Fig. 8) Pendent / HB (See Fig. 2) Horizontal Sidewall / HB (See Fig. 7) Upright (See Fig. 10) with Model F3QR56 Dry sprinklers will void all guarantees, warranties, listings and approvals. Inlet fittings are available with 1” NPT, ISO 7-1R1, 3/4” NPT, or ISO7-1R3/4 threads. Sprinklers with 3/4” NPT and ISO7- 1R3/4 inlet fittings are intended primarily for replacement of 2. existing 3/4” or ISO7-1R3/4 inlet dry sprinklers, but may also be used in new installations. See the Available Configurations, Listings, and Approvals table in this Bulletin for further information on Model F3QR56 Dry sprinklers. Available Configurations, Listings, and Approvals Sprinkler Model Escutcheon or Cover Plate Available Length (See Figs. 1-9) Listings and Approvals(1) Inlet Threads Sprinkler Identification Number (SIN) F3QR56 Dry Pendent Standard Escutcheon 2” to 36” (50 to 900 mm) cULus, NYC 3/4” NPT or ISO7-1R3/4 R5714 HB Extended Escutcheon 3-1/2” to 36” (90 to 900 mm) F1 Recessed Escutcheon FP Recessed Escutcheon CCP Cover Plate Standard Escutcheon 2” to 48” (50 to 1200 mm) cULus, FM, NYC 1” NPT or ISO7-1R1 HB Extended Escutcheon 3-1/2” to 48” (90 to 1200 mm) F1 Recessed Escutcheon FP Recessed Escutcheon CCP Cover Plate F3QR56 Dry Horizontal Sidewall Standard Escutcheon 2” to 48” (50 to 1200 mm) cULus(2), NYC(2)3/4” NPT or ISO7-1R3/4 R5734 HB Extended Escutcheon 3-1/2” to 48” (90 to 1200 mm) F1 Recessed Escutcheon FP Recessed Escutcheon Standard Escutcheon 2” to 48” (50 to 1200 mm)cULus(2), FM(3), NYC(2) 1” NPT or ISO7-1R1 HB Extended Escutcheon 3-1/2” to 48” (90 to 1200 mm) F1 Recessed Escutcheon 3-1/2” to 48” (90 to 1200 mm) cULus(2), FM(3)(4), NYC(2)FP Recessed Escutcheon F3QR56 Dry Upright N/A 5” to 48” (127 to 1200 mm)cULus(2)1” NPT or ISO7-1R1 R5724 (1) For available temperature ratings and finishes see the Temperature Ratings and Finishes tables, respectively, in this Bulletin. (2) cULus Listing and NYC for Light Hazard and Ordinary Hazard only. (3) FM Approved for Light Hazard only. (4) Model F3QR56 Dry Horizontal Sidewall with Model F1 or Model FP recessed escutcheon are FM Approved as Standard Response. Listing and Approval Agencies See the Available Configurations, Listings, and Approvals table in this Bulletin for listings and approvals applicable to each available configuration. 1. Listed by Underwriters Laboratories, Inc. and UL Certified for Canada (cULus) 2. Certified by FM Approvals (FM) 3. Permitted in New York City based on UL Listing per Local Law 33/2007 (NYC) Technical Data Nominal K-Factor: 5.6 gpm/psi1/2 (80 L/min/bar1/2) Sprinkler Listing or Approval Deflector to Ceiling Distance Maximum Working Pressure F3QR56 Dry Pendent cULus, NYC See note below 250 psi (17.2 bar) FM See note below 175 psi (12 bar) F3QR56 Dry Horizontal Sidewall cULus, NYC 4” to 6 “250 psi (17.2 bar) 4” to 12”175 psi (12 bar) FM See note below 175 psi (12 bar) F3QR56 Dry Upright cULus See note below 175 psi (12 bar) Note: Deflector distance to be in accordance with applicable NFPA, FM, or other agency requirements. Information is provided only when additional clarification is necessary. Temperature Classification Glass Bulb Color Sprinkler Temperature Rating Cover Plate Temperature Rating Maximum Ceil- ing Temperature Listings and Approvals(1) Ordinary Orange 135°F (57°C)135°F (57°C)100°F (38°C)cULus, FM, NYCRed155°F (68°C) Intermediate Yellow 175°F (79°C)165°F (74°C)150°F (66°C)cULus, NYC Intermediate Green 200°F (93°C)165°F (74°C)150°F (66°C)cULus, FM, NYC High Blue 286°F (141°C)None 225°F (107°C)cULus, FM(2), NYC 165°F (74°C)150°F (66°C)cULus, NYC (1) For listed and approved sprinkler, escutcheon, and inlet configurations see the Available Configurations, Listings, and Approvals table in this Bulletin. (2) High temperature classification is FM Approved with Standard and Model HB escutcheons only. Finishes4 Component Sprinkler Escutcheon(1)Cover Plate Standard Finishes Bronze Brass(3)White Paint White Polyester(2)White Polyester ChromeChromeChrome Special Application Finishes Electroless Nickel PTFE(2)Type 316 Stainless Steel Satin Chrome Black Paint Custom Color Paint Black Plating Black Polyester(2)Black Polyester Custom Color Polyester Customer Color Polyester (1) Standard and Model HB escutcheons are supplied with both the can and escutcheon finished. Model F1 escutcheons are supplied with both the collar and escutcheon finished. Model FP escutcheons are supplied with the escutcheon finished; the cup is galvanized or stainless steel with no further finish. (2) cULus Listed as a Corrosion Resistant Sprinkler. (3) Brass finish available for standard, Model F1, and Model FP escutcheons only. (4) Dry upright sprinkler available in standard bronze only. 3. 4. Note: The sprinkler can protrudes ¼” when escutcheon is in nominal position. Escutcheon adjustment provides -¼” (-6mm) to +1¼” (+32mm) “A” dimension adjustment range. Fig. 1 Model F3QR56 Dry Pendent Sprinkler with Standard Escutcheon (SIN R5714) “A” Dim.2” to 48” (51mm to 1219mm) in 1/4” (6mm) increments for 1” connections or 2” to 36” (51mm to 914mm) in 1/4” (6mm) increments for 3/4” connections Sprinkler Guard: Model C2 Model F3QR56 Dry Pendent Sprinkler with Model HB Extended Escutcheon (SIN R5714) “A” Dim.3½” to 48” (89mm to 1219mm) in 1/4” (6mm) increments for 1” connections or 3½” to 36” (89mm to 914mm) in 1/4” (6mm) increments for 3/4” connections Note: The sprinkler can protrudes 1¼” when escutcheon is in nominal position. Escutcheon adjustment provides -½” (-12.7mm) to +½” (+12.7mm) “A” dimension adjustment range. Fig. 2 5. Sprinkler Guard: Model C2 Note: Do not install the Model F3QR56 Dry Pendent sprinkler with the Model FP escutcheon in ceilings which have positive pressure in the space above. Fig. 3 6. Model F3QR56 Dry Pendent Sprinkler with Model FP Recessed Escutcheon (SIN R5714) “A” Dim.31/2” to 48” (89mm to 1219mm) in 1/4” (6mm) increments for 1” connections or 3½” to 36” (89mm to 914mm) in 1/4” (6mm) increments for 3/4” connections Model F3QR56 Dry Pendent Sprinkler with Model CCP Cover Plate (SIN R5714) “A” Dim.31/2” to 48” (89mm to 1219mm) in 1/4” (6mm) increments for 1” connections or 3½” to 36” (89mm to 914mm) in 1/4” (6mm) increments for 3/4” connections Note: Do not install the Model F3QR56 Dry Pendent sprinkler with the Model CCP cover plate in ceilings which have positive pressure in the space above. Fig. 4 7. Model F3QR56 Dry Pendent Sprinkler with Model F1 Recessed Escutcheon (SIN R5714) “A” Dim.31/2” to 48” (89mm to 1219mm) in 1/4” (6mm) increments for 1” connections or 3½” to 36” (89mm to 914mm) in 1/4” (6mm) increments for 3/4” connections. Fig. 5 8. Note: The sprinkler can protrudes ¼” when escutcheon is in nominal position. Escutcheon adjustment provides -¼” (-6mm) to +1¼” (+32mm) “A” dimension adjustment range. Fig. 6 9. Model F3QR56 Dry Horizontal Sidewall Sprinkler with Standard Escutcheon (SIN R5734) “A” Dim.2” to 48” (51mm to 1219mm) in 1/4” (6mm) increments for 1” connections or 2” to 36” (51mm to 914mm) in 1/4” (6mm) increments for 3/4” connections 10. Model F3QR56 Dry Horizontal Sidewall Sprinkler with Model HB Escutcheon (SIN R5734) “A” Dim.31/2” to 48” (89mm to 1219mm) in 1/4” (6mm) increments for 1” connections or 3½” to 36” (89mm to 914mm) in 1/4” (6mm) increments for 3/4” connections Note: The sprinkler can protrudes 1¼” when escutcheon is in nominal position. Escutcheon adjustment provides -½” (-12.7mm) to +½” (+12.7mm) “A” dimension adjustment range. Fig. 7 11. Model F3QR56 Dry Horizontal Sidewall Sprinkler with Model FP Recessed Escutcheon (SIN R5734) “A” Dim.31/2” to 48” (89mm to 1219mm) in 1/4” (6mm) increments for 1” connections or 3½” to 36” (89mm to 914mm) in 1/4” (6mm) increments for 3/4” connections Note: Do not install the Model F3QR56 Dry Horizontal Sidewall sprinkler with the Model FP escutcheon in walls which are positively pressurized with respect to the protected space. Fig. 8 12. Model F3QR56 Dry Horizontal Sidewall Sprinkler with Model F1 Recessed Escutcheon (SIN R5734) “A” Dim.31/2” to 48” (89mm to 1219mm) in 1/4” (6mm) increments for 1” connections or 3½” to 36” (89mm to 914mm) in 1/4” (6mm) increments for 3/4” connections Fig. 9 13. Model F3QR56 Dry Upright (SIN 5724) Order Dimensions 5” to 48” (127 mm to 1219 mm) Fig. 10 Fig. 11 14. Fig. 12 15. Fig. 14 - Model XLO2 Wrench Fig. 13 - Model F3R Wrench 16. Fig. 15 17. Installation Instructions Model F3QR56 Dry sprinklers must only be installed in the following fittings: 1. The side outlet of an ANSI B 16.3 class 150 (malleable or ductile) or ANSI B16.4 class 125 (cast) iron pipe tee 2. The run outlet of an ANSI B 16.3 class 150 (malleable or ductile) or ANSI B16.4 class 125 (cast) iron pipe tee, with the side outlet plugged (wet-pipe systems only) 3. Spears Manufacturing Company Brass Thread In- sert Style or Special Reinforced Plastic Thread Style Listed adapter or tee (wet-pipe systems only) (gasket sealed outlets shall not be used) 4. Any Listed CPVC sprinkler adapter or tee only in ac- cordance with Fig. 12 and upon verification that the CPVC adapter or tee does not interfere with the sprin- kler’s inlet (wet-pipe systems only) (gasket sealed outlets shall not be used) Model F3QR56 dry sprinklers must not be installed into el- bows, welded outlets, gasket sealed outlets, or couplings. Installation of the Model F3QR56 Dry sprinkler is not recom- mend in copper pipe systems, as this may reduce the life expectancy of the sprinkler. In all dry-pipe system installations, the Model F3QR56 Dry sprinkler must be installed with protrusion into the fitting in accordance with Fig. 1 through Fig. 10 in this Bulletin. Do not install Model F3QR56 Dry sprinklers with the standard (long) inlet fitting into CPVC fittings that have an internal obstruction (see Fig. 12); this will damage the sprinkler, the fitting, or both. Model F3QR56 Dry sprinklers are available with a short “PL” inlet fitting for installation on CPVC fittings of wet-pipe sprinkler systems only. Model F3QR56 Dry sprinklers connected to wet-pipe sys- tems must be installed with the Exposed Minimum Barrel Length required by Fig. 11 located in a Heated Area. An orange protective clip is factory installed on the sprin- kler to protect the glass bulb thermal element from dam- age. The clip should remain in place during installation of the sprinkler and be removed when the sprinkler system is placed in service. Sprinklers with 3/4” NPT and ISO7-1R3/4 inlets are supplied with a protective cap on the inlet that must be removed before installation. Use the following steps for installation: 1. Cut a hole in the wall or ceiling directly in-line with the outlet of the fitting. See the Installation Data table for the recommended hole diameter based on the es- cutcheon or cover plate option selected. 2. Apply pipe joint compound or PTFE tape to the male threads of the sprinkler’s inlet fitting. 3. Install the sprinkler in the fitting using the installation wrench specified in the Installation Data table. The Model F3R wrench is designed to be inserted into the groves in the sprinkler’s wrench boss as shown in Fig. 13. The Model XLO2 wrench is designed to fit into the cup and engage the wrench boss as shown in Fig. 14. Do NOT wrench any part of the sprinkler assembly other than the wrench boss. When inserting or remov- ing the wrench from the sprinkler, care should be tak- en to prevent damage to the sprinkler. The sprinkler is then tightened into the pipe fitting to achieve a leak free connection. The recommended minimum to max- imum installation torque is 22 - 30 lb-ft (30 – 40 N-m) for 1” NPT and ISO7-1R1 sprinklers, and 14 - 20 lb-ft (19 – 27 N-m) for 3/4” NPT and ISO7-1R3/4 sprinklers. 3a. Alternatively, where access to the outer tube of the sprinkler is available, the Model F3QR56 Dry sprinkler may be installed using a pipe wrench. The pipe wrench shall only be permitted to inter- face with the galvanized steel outer tube portion of the sprinkler (Item #8 in Fig. 15). Do NOT wrench any other portion of the sprinkler assembly. A pipe wrench can install the sprinkler into the fitting with a large amount of torque; consideration should be given to the need for future removal of the sprin- kler because the installation torque will have to be matched or exceeded to remove the sprinkler. The recommended minimum to maximum installation torque is 22 - 30 lb-ft (30 – 40 N-m) for 1” NPT and ISO7-1R1 sprinklers, and 14 - 20 lb-ft (19 – 27 N-m) for 3/4” NPT and ISO7-1R3/4 sprinklers. 4. Standard and Model HB escutcheons can be in- stalled by slipping the escutcheon over the can until the escutcheon is seated against the ceiling or wall. Model F1 escutcheons are installed by pressing the escutcheon onto the collar until the escutcheon is seated against the ceiling or wall. The Model FP es- cutcheon is installed by pressing or threading the es- cutcheon into the cup by hand; the escutcheon can be tightened against the ceiling or wall by turning the escutcheon in a clockwise direction and removed by turning the escutcheon in a counter-clockwise direc- tion. To install the Model CCP cover plate, first remove the protective clip. Install the Model CCP cover plate on the sprinkler by pressing or threading the cover plate into the cup by hand; the cover plate can be tightened against the ceiling by turning the cover plate in a clockwise direction and removed by turning the cover plate in a counter-clockwise direction. 5. Remove the orange protective clip when placing the sprinkler system in service. 18. 3. Inlet Threads: [1” NPT][ISO7-1R1][3/4” NPT][ISO7- 1R3/4] 4. Inlet Fitting: [Long – Standard Inlet Fitting][Short “PL” – Wet Pipe Systems only] 5. Sprinkler Temperature Rating: See Temperature Rat- ings table 6. Sprinkler Finish: See Finishes Table 7. Escutcheon/Cover Plate Finish: See Finishes Table 8. Length: *For dry pendents and dry sidewalls: “A” Dimen- sion is from face of tee to face of finished ceiling or wall in 1/4” (6mm) increments. See Fig. 1 through Fig. 9. *For dry uprights: Order dimension is from face of tee to top of deflector in 1/4” (6mm) increments. See Fig. 10. Notes: 1. For Dry Upright, customer is responsible for determining the correct deflector distance from structure above. 2. Length is based on normally gauged pipe thread “make- up” of .600” (15mm) per ANSI B2.1 (approximately 7-1/2 threads). Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Manufactured by Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 04/20 P/N 9999970175 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years. Installation Data Sprinkler Model Escutcheon or Cover Plate Suggested Hole Diameter in Wall or Ceiling Installation Wrench Required Centerline of Sprinkler Tube/Inlet to Finished Ceiling Vertical Dimension* F3QR56 Dry Pendent Standard Escutcheon 2-1/8” (54 mm)F3R Not Applicable HB Extended Escutcheon 2-1/2” (64 mm)F3R F1 Recessed Escutcheon 2-1/4” (57 mm)XLO2 FP Recessed Escutcheon 2-1/2” (64 mm)XLO2 CCP Cover Plate XLO2 F3QR56 Dry Horizontal Sidewall Standard Escutcheon 2-1/8” (54 mm)F3R 4-5/8” to 12-5/8” (118 mm to 321 mm)HB Extended Escutcheon 2-1/2” (64 mm)F3R F1 Recessed Escutcheon 2-1/4” (57 mm)XLO2 cULus, NYC 4-5/8” to 6-5/8” (118 mm to 168 mm)FP Recessed Escutcheon 2-1/2” (64 mm)XLO2 F1 Recessed Escutcheon 2-1/4” (57 mm)XLO2 FM 4-5/8” to 12-5/8” (118 mm to 321 mm)FP Recessed Escutcheon 2-1/2” (64 mm)XLO2 F3QR56 Dry Upright N/A 1-1/2” (38mm)F3R Not Applicable *Note: Based on 5/8” (16 mm) centerline of sprinkler tube/inlet to defector vertical distance. Maintenance The Model F3QR56 Dry Sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not remove the factory applied thermally sen- sitive wax fillet between the bulb supporting cup and the wrenching boss. Do not replace this wax with a substitute substance. An Alternate substance may interfere with proper operation of the sprinkler. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by us- ing a soft brush or gently vacuuming. Replace any sprin- kler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or op- erated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Ordering Information Specify: 1. Sprinkler: [Model F3QR56 Dry Pendent SIN R5714] [Model F3QR56 Dry Horizontal Sidewall SIN R5734] [Model F2QR Dry Upright SIN R5724] 2. Escutcheon/Cover Plate: [None][Standard escutch- eon][Model HB extended escutcheon][Model F1 re- cessed escutcheon][Model FP recessed escutcheon] [Model CCP cover plate – pendent only] FREEDOM® RESIDENTIAL HORIZONTAL SIDEWALL LEAD FREE SPRINKLER VK4860 (K4.0) TECHNICAL DATA Page 1 of 6 Form No. F_011212 18.11.01 Rev 17.1.P65 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 1. DESCRIPTION Viking Freedom® Residential Horizontal Sidewall Lead Free* Sprinkler VK4860 is a small, thermosensitive, glass-bulb residential sprinkler available in several dif- ferent finishes and temperature ratings to meet varying design requirements. The sprinkler orifice design, with a K-Factor of 4.0 (57.7 metric†), allows efficient use of available water supplies for the hydraulically designed fire-protection system. The glass bulb operating element and special deflector characteristics meet the challenges of residential sprinkler standards. * Lead content complies with the definition of ‘Lead Free’ established in the Reduction of Lead in Drinking Water Act (S.3874) endorsed by AWWA’s Water Utility Council, and California Assembly Bill #1953. 2. LISTINGS AND APPROVALS UL Listed (C-UL-US-EU): Category VKKW UL Classified to: NSF/ANSI Standard 61, Drinking Water System Components and NSF 372 (MH48034). Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 2012. Minimum Operating Pressure: Refer to the Approval Chart. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1/2” (15 mm) NPT Nominal K-Factor: 4.0 U.S. (57.7 metric†) † Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-7/16” (62 mm) Covered by the following US Patent Nos: 7,854,269 and 7,712,218 Material Standards: Frame Casting: Brass UNS-C89833 Deflector: Phosphor Bronze UNS-C51000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Polytetrafluoroethylene (PTFE) Tape Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Compression Screws: 18-8 Stainless Steel Yoke: Phosphor Bronze UNS-C51000 Ordering Information: (Also refer to the current Viking price list.) Sprinkler: Base Part No. 18089 Order Sprinkler VK4860 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the tempera- ture rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, and Black Polyester = M-/B Temperature Suffix: 155 °F (68 °C) = B, 175 °F (79 °C) = D For example, sprinkler VK4860 with a Brass finish and a 155 °F (68 °C) temperature rating = Part No. 18089AB. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches: A. Standard Wrench: Part No. 21475M/B (available since 2017) B. Wrench for recessed sprinklers: Part No. 13655W/B** (available since 2006) **A ½” ratchet is required (not available from Viking). Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A (available since 1971) B. Twelve-head capacity: Part No. 01725A (available since 1971) Replaces Form No. F_011212 Rev 17.1 (Added P65 Warning.) FREEDOM® RESIDENTIAL HORIZONTAL SIDEWALL LEAD FREE SPRINKLER VK4860 (K4.0) TECHNICAL DATA Page 2 of 6 Form No. F_011212 18.11.01 Rev 17.1.P65 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the yoke, pip cap, and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Sprinkler VK4860 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking’s current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating1 Maximum Ambient Ceiling Temperature2 Bulb Color Ordinary 155 °F (68 °C)100 °F (38 °C)Red Intermediate 175 °F (79 °C)150 °F (65 °C)Yellow Sprinkler Finishes: Brass, Chrome, White Polyester, and Black Polyester. Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Figure 2: Wrench 13655W/B for Recessed Sprinkler VK4860 Figure 1: Standard Sprinkler Wrench 21475M/B FREEDOM® RESIDENTIAL HORIZONTAL SIDEWALL LEAD FREE SPRINKLER VK4860 (K4.0) TECHNICAL DATA Page 3 of 6 Form No. F_011212 18.11.01 Rev 17.1.P65 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval ChartViking VK4860, 4.0 K-Factor Residential Horizontal Sidewall Sprinkler For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13, refer to the design criteria. For Ceiling types refer to current Editions of NFPA 13, 13R or 13D. Sprinkler Base Part Number 1 SIN NPT Thread Size Nominal K-Factor Maximum Water Working Pressure Overall Length Inches mm U.S.metric 2 Inches mm 18089 VK4860 1/2 15 4.0 57.7 175 psi (12 bar)2-7/16 62 Max. Coverage Area 3 Width X Length Ft. X Ft. (m X m) Max. Spac- ing Ft. (m) Ordinary Temp Rating (155 °F/68 °C) Intermediate Temp Rating (175 °F/79 °C)Top of Deflec- tor to Ceiling Installation Type Listings and Approvals 4 Mini- mum Spacing Ft. (m) Flow 3 GPM (L/min) Pressure 3 PSI (bar) Flow 3 GPM (L/min) Pressure 3 PSI (bar) 5 NYC NSF9 12 X 12 (3.7 X 3.7)12 (3.7)11 (41.7)7.6 (0.52)11 (41.7)7.6 (0.52) 4 to 6 inches Standard surface- mounted escutch- eons or the Microfast® Model F-1 Adjustable Escutcheon, or recessed with the Micromatic® Model E-1, E-2, E-3 or G-1 Recessed Escutcheon See Foot- note 6. See Foot- note 7. See Foot- note 6. 8 (2.4) 14 X 14 (4.3 X 4.3)14 (4.3)12 (45.5)9 (0.62)12 (45.5)9 (0.62) 16 X 16 (4.9 X 4.9)16 (4.9)13 (49.3)10.6 (0.73)13 (49.3)10.6 (0.73) 16 X 18 (4.9 X 5.5)16 (4.9)16 (60.6)16 (1.10)16 (60.6)16 (1.10) 16 X 20 (4.9 X 6.1)16 (4.9)22 (83.3)30.3 (2.09)22 (83.3)30.3 (2.09) 16 X 22 (4.9 X 6.7)16 (4.9)24 (90.8)36 (2.48)24 (90.8)36 (2.48) 18 X 18 (5.5 X 5.5)18 (5.5)18 (68.1)20.3 (1.40)19 (71.9)22.6 (1.60) 18 X 20 (5.5 X 6.1)18 (5.5)22 (83.3)30.3 (2.09)22 (83.3)30.3 (2.09) 20 X 20 (6.1 X 6.1)20 (6.1)22 (83.3)30.3 (2.09)22 (83.3)30.3 (2.09) 12 X 12 (3.7 X 3.7)12 (3.7)12 (45.5)9 (0.62)12 (45.5)9 (0.62) 6 to 12 inches 14 X 14 (4.3 X 4.3)14 (4.3)12 (45.5)9 (0.62)13 (49.3)10.6 (0.73) 16 X 16 (4.9 X 4.9)16 (4.9)14 (53.0)12.3 (0.84)14 (53.0)12.3 (0.84) 16 X 18 (4.9 X 5.5)16 (4.9)16 (60.6)16 (1.10)16 (60.6)16 (1.10) 16 X 20 (4.9 X 6.1)16 (4.9)23 (87.1)33.1 (2.28)23 (87.1)33.1 (2.28) 16 X 22 (4.9 X 6.7)16 (4.9)26 (98.4)42.3 (2.91)26 (98.4)42.3 (2.91) 18 X 18 (5.5 X 5.5)18 (5.5)18 (68.1)20.3 (1.40)19 (71.9)22.6 (1.60) 18 X 20 (5.5 X 6.1)18 (5.5)23 (87.1)33.1 (2.28)23 (87.1)33.1 (2.28) 20 X 20 (6.1 X 6.1)20 (6.1)24 (90.8)36 (2.48)24 (90.8)36 (2.48) Footnotes 1 Part number shown is the base part number. For complete part number, refer to Viking’s current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 For areas of coverage smaller than shown, use the “Flow” and “Pressure” for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum “Flow” and “Pressure” used. 4 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. 5 Listed by Underwriter’s Laboratories, Inc. for use in the U.S., Canada, and European Union. 6 Approved Finishes are: Brass, Chrome, White Polyester, and Black Polyester 8 7 Meets New York City requirements, effective July 1, 2008. 8 Other paint colors are available on request with the same C-UL-US-EU listings as the standard finish colors. 9 UL Classified to: NSF/ANSI Standard 61, Drinking Water System Components and NSF 372 (MH48034). FREEDOM® RESIDENTIAL HORIZONTAL SIDEWALL LEAD FREE SPRINKLER VK4860 (K4.0) TECHNICAL DATA Page 4 of 6 Form No. F_011212 18.11.01 Rev 17.1.P65 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESIGN CRITERIA (Also refer to the Approval Chart.) UL Listing Requirements (C-UL-US-EU): When using Viking Residential Horizontal Sidewall Lead Free Sprinkler VK4860 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of coverage and minimum water supply requirements shown in the Approval Chart. For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: • The flow rates given in the Approval Chart for NFPA 13D and NFPA 13R applications for each listed area of coverage, or • Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the “design area” in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13. • Minimum distance between residential sprinklers: 8 ft. (2.4 m). • The VK4860 horizontal sidewall sprinkler deflector shall be located a minimum of 1-1/4“ (31.8 mm) and a maximum of 6” (152 mm) from the wall on which it is installed. DEFLECTOR POSITION: Install sprinkler VK4860 with the leading edge of the deflector oriented parallel to the ceiling and the sprinkler frame arms oriented perpendicular to the ceiling (see Figure 4). THE TOP SURFACE OF THE DEFLECTOR IS MARKED “TOP”. The sprinkler must be oriented as shown in Figure 3 below. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080190, F_080814, and F_080415 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. Figure 3: Correct Orientation of the Deflector FREEDOM® RESIDENTIAL HORIZONTAL SIDEWALL LEAD FREE SPRINKLER VK4860 (K4.0) TECHNICAL DATA Page 5 of 6 Form No. F_011212 18.11.01 Rev 17.1.P65 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Figure 4: Sprinkler VK4860 Dimensions with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon Figure 5: Sprinkler VK4860 Dimensions with the Model E-1 and E-2 Recessed Escutcheons FREEDOM® RESIDENTIAL HORIZONTAL SIDEWALL LEAD FREE SPRINKLER VK4860 (K4.0) TECHNICAL DATA Page 6 of 6 Form No. F_011212 18.11.01 Rev 17.1.P65 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Figure 6: Sprinkler VK4860 Dimensions with the Model G-1 Escutcheon Replaces Form No. F_011212 Rev 17.1 (Added P65 Warning.) FIRE SUPPRESSION SERVICES 4508 BAXTER ROAD P.O. BOX 37 PRINCETON, MN 55371 763-389-2183 Job Name : ORONO COMMONS Building : 2430-2440 NORTH BLOSSOM CIRCLE Location : FIRST FLOOR DA-1 System : Contract : Data File : 2430 DA-1.WXF Computer Programs by Hydratec Inc. Route 111 W indham N.H. USA 03087 FIRE SUPPRESSION SERVICES Page 1 ORONO COMMONS Date 092908 HYDRAULIC DESIGN INFORMATION SHEET Name - ORONO COMMONS Date - 5-25-23 Location - FIRST FLOOR DA-1 Building - 2430-2440 NORTH BLOSSOM CIRCLE System No. - Contractor - FIRE SUPPRESSION SERVICES Contract No. - Calculated By - J GANTER Drawing No. - FP-1 Construction: (X) Combustible ( ) Non-Combustible Ceiling Height 9' OCCUPANCY - RESIDENTIAL S Type of Calculation: (34)NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Y Number of Sprinklers Flowing: ( )1 (X)2 ( )4 ( ) S ( )Other T ( )Specific Ruling Made by Date E M Listed Flow at Start Point - 17 Gpm System Type Listed Pres. at Start Point - 12 Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 18 x 18 ( ) Deluge ( ) PreAction E Domestic Flow Added - 0 Gpm Sprinkler or Nozzle S Additional Flow Added - Gpm Make RELIABLE Model RES 49 I Elevation at Highest Outlet - 10.25Feet Size 1/2 K-Factor 4.9 G Note: Temperature Rating 155 N Calculation Gpm Required 34.8 Psi Required 34.3 At P0C Summary C-Factor Used: Overhead 150 Underground 150 W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 12-1-21 Rated Cap. Cap. T Time of Test - 11:00 AM @ Psi Elev. E Static (Psi) - 61 Elev. R Residual (Psi) - - Other Well Flow (Gpm) - -- Proof Flow Gpm S Elevation - 2 P Location: WILLOW DRIVE & KELLEY PKWY P L Source of Information: STATIC PRESSURE GAUGED AT SITE Y Computer Programs by Hydratec Inc. Route 111 W indham N.H. USA 03087 FIRE SUPPRESSION SERVICESPage 2 ORONO COMMONSDate 092908 10203040E50R60U70S80S90E100R110P12013014015050 100 150 200 250 300 350 400 450FLOW ( N ^ 1.85 )City Water Supply:Demand:C1C2C1 - Static Pressure : 61 C2 - Residual Pressure: 20 C2 - Residual Flow : 500 D1D2D1 - Elevation : 3.032 D2 - System Flow : 34.7613 D2 - System Pressure : 34.283 Hose ( Adj City ) : _______Hose ( Demand ) : _______D3 - System Demand : 34.7613 Safety Margin : 26.421 Water Supply Curve (C)Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 FIRE SUPPRESSION SERVICESPage 3 ORONO COMMONSDate 092908 Fitting Legend Abbrev. Name ½ ¾ 1 1¼ 1½ 2 2½ 3 3½ 4 5 6 8 10 12 14 16 18 20 24 E 90' Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Mil B Ball Milw BB-SC100 2.25 2 2.5 2.25 10 N CPVC 90'Ell Harvel-Spears 7 5 5 6 7 9 12 13 0 0 0 0 0 0 0 0 0 0 0 0 O CPVC Tee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 S Generic Swing Check Valve 4 5 5 7 9 11 14 16 19 22 27 32 45 55 6576 87 98 109 130 T 90' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Fittings Used SummaryComputer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 FIRE SUPPRESSION SERVICES Page 4 ORONO COMMONS Date 092908 Node Elevation K-Fact Pt Pn Flow Density Area Press No.Actual Actual Req. D101 9.0 4.9 12.0 na 16.97 0.05 324 12.0 D102 9.0 4.9 13.18 na 17.79 0.05 324 12.0 S01 10.25 11.77 na S02 10.25 12.98 na 3 10.25 16.38 na T0R 2.0 24.31 na B0R 1.0 28.88 na CURB -8.0 36.92 na P0C 2.0 34.28 na The maximum velocity is 11.71 and it occurs in the pipe between nodes S02 and 3 Pressure / Flow Summary - STANDARD Computer Programs by Hydratec Inc. Route 111 W indham N.H. USA 03087 FIRE SUPPRESSION SERVICES Page 5 ORONO COMMONS Date 092908 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn D101 16.97 1.101 1N 5.0 1.250 12.000 K Factor = 4.90 to 150 0.0 5.000 -0.541 S01 16.97 0.0502 0.0 6.250 0.314 Vel = 5.72 0.0 16.97 11.773 K Factor = 4.95 D102 17.79 1.101 1O 5.0 1.250 13.177 K Factor = 4.90 to 150 0.0 5.000 -0.541 S02 17.79 0.0547 0.0 6.250 0.342 Vel = 6.00 0.0 17.79 12.978 K Factor = 4.94 S01 16.97 1.101 1N 5.0 19.000 11.773 to 150 0.0 5.000 0.0 S02 16.97 0.0502 0.0 24.000 1.205 Vel = 5.72 S02 17.79 1.101 1N 5.0 13.000 12.978 to 150 0.0 5.000 0.0 3 34.76 0.1892 0.0 18.000 3.405 Vel = 11.71 3 0.0 1.101 1N 5.0 13.000 16.383 to 150 1O 5.0 10.000 3.573 T0R 34.76 0.1892 0.0 23.000 4.352 Vel = 11.71 T0R 0.0 1.101 1Mil 4.303 8.000 24.308 to 150 1S 9.563 13.865 0.433 B0R 34.76 0.1892 0.0 21.865 4.136 Vel = 11.71 B0R 0.0 1.265 1E 1.868 40.000 28.877 to 150 1Mil 1.167 3.035 3.898 CURB 34.76 0.0962 0.0 43.035 4.141 Vel = 8.87 CURB 0.0 1.481 1T 8.049 30.000 36.916 to 150 0.0 8.049 -4.331 P0C 34.76 0.0446 0.0 38.049 1.698 Vel = 6.47 0.0 34.76 34.283 K Factor = 5.94 Final Calculations - Hazen-Williams Computer Programs by Hydratec Inc. Route 111 W indham N.H. USA 03087 FIRE SUPPRESSION SERVICES 4508 BAXTER ROAD P.O. BOX 37 PRINCETON, MN 55371 763-389-2183 Job Name : ORONO COMMONS Building : 2430-2440 N BLOSSOM CIRCLE Location : SECOND FLOOR DA-2 System : Contract : Data File : 2430 DA-2.WXF Computer Programs by Hydratec Inc. Route 111 W indham N.H. USA 03087 FIRE SUPPRESSION SERVICES Page 1 ORONO COMMONS Date 062911 HYDRAULIC DESIGN INFORMATION SHEET Name - ORONO COMMONS Date - 5-25-23 Location - SECOND FLOOR DA-2 Building - 2430-2440 N BLOSSOM CIRCLE System No. - Contractor - FIRE SUPPRESSION SERVICES‚ LLC Contract No. - Calculated By - J GANTER Drawing No. - Construction: (X) Combustible ( ) Non-Combustible Ceiling Height 10' OCCUPANCY - RESIDENTIAL S Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Y Number of Sprinklers Flowing: ( )1 (X)2 ( )4 ( ) S ( )Other T ( )Specific Ruling Made by Date E M Listed Flow at Start Point - 13 Gpm System Type Listed Pres. at Start Point - 10.6 Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 16 x 16 ( ) Deluge ( ) PreAction E Domestic Flow Added - Gpm Sprinkler or Nozzle S Additional Flow Added - Gpm Make VIKING Model VK4860 I Elevation at Highest Outlet - 20 Feet Size 1/2 K-Factor 4.0 G Note: Temperature Rating 155 N Calculation Gpm Required 26.2 Psi Required 32.6 At POC Summary C-Factor Used: Overhead 150 Underground 150 W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 12-1-21 Rated Cap. Cap. T Time of Test - 10:00 AM @ Psi Elev. E Static (Psi) - 61 Elev. R Residual (Psi) - -- Other Well Flow (Gpm) - --- Proof Flow Gpm S Elevation - 2 P Location: WILLOW DRIVE & KELLY PARKWAY P L Source of Information: STATIC PRESSURE GAUGED Y Computer Programs by Hydratec Inc. Route 111 W indham N.H. USA 03087 FIRE SUPPRESSION SERVICESPage 2 ORONO COMMONSDate 062911 10203040E50R60U70S80S90E100R110P12013014015050 100 150 200 250 300 350 400 450FLOW ( N ^ 1.85 )City Water Supply:Demand:C1C2C1 - Static Pressure : 61 C2 - Residual Pressure: 20 C2 - Residual Flow : 500 D1D2D1 - Elevation : 7.796 D2 - System Flow : 26.1684 D2 - System Pressure : 32.587 Hose ( Adj City ) : _______Hose ( Demand ) : _______D3 - System Demand : 26.1684 Safety Margin : 28.238 Water Supply Curve (C)Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 FIRE SUPPRESSION SERVICESPage 3 ORONO COMMONSDate 062911 Fitting Legend Abbrev. Name ½ ¾ 1 1¼ 1½ 2 2½ 3 3½ 4 5 6 8 10 12 14 16 18 20 24 E 90' Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Mil B Ball Milw BB-SC100 2.25 2 2.5 2.25 10 N CPVC 90'Ell Harvel-Spears 7 5 5 6 7 9 12 13 0 0 0 0 0 0 0 0 0 0 0 0 O CPVC Tee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 S Generic Swing Check Valve 4 5 5 7 9 11 14 16 19 22 27 32 45 55 6576 87 98 109 130 T 90' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Fittings Used SummaryComputer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 FIRE SUPPRESSION SERVICES Page 4 ORONO COMMONS Date 062911 Node Elevation K-Fact Pt Pn Flow Density Area Press No.Actual Actual Req. S03 20.0 4 10.6 na 13.02 0.05 256 10.6 S04 20.0 4 10.8 na 13.15 0.05 256 10.6 1 20.0 11.47 na 2 10.25 18.08 na 3 10.25 20.43 na T0R 10.25 23.0 na B0R 2.0 29.13 na CURB -6.0 35.05 na P0C 2.0 32.59 na The maximum velocity is 8.82 and it occurs in the pipe between nodes S04 and 1 Pressure / Flow Summary - STANDARD Computer Programs by Hydratec Inc. Route 111 W indham N.H. USA 03087 FIRE SUPPRESSION SERVICES Page 5 ORONO COMMONS Date 062911 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn S03 13.02 1.101 1N 5.0 1.500 10.600 K Factor = 4.00 to 150 0.0 5.000 0.0 S04 13.02 0.0308 0.0 6.500 0.200 Vel = 4.39 S04 13.15 1.101 1N 5.0 1.000 10.800 K Factor = 4.00 to 150 0.0 5.000 0.0 1 26.17 0.1118 0.0 6.000 0.671 Vel = 8.82 1 0.0 1.101 1N 5.0 11.330 11.471 to 150 1O 5.0 10.000 4.223 2 26.17 0.1119 0.0 21.330 2.386 Vel = 8.82 2 0.0 1.101 1O 5.0 16.000 18.080 to 150 0.0 5.000 0.0 3 26.17 0.1119 0.0 21.000 2.350 Vel = 8.82 3 0.0 1.101 1O 5.0 13.000 20.430 to 150 1N 5.0 10.000 0.0 T0R 26.17 0.1119 0.0 23.000 2.573 Vel = 8.82 T0R 0.0 1.101 1S 9.563 9.000 23.003 to 150 1Mil 4.303 13.865 3.573 B0R 26.17 0.1119 0.0 22.865 2.558 Vel = 8.82 B0R 0.0 1.265 1E 1.868 40.000 29.134 to 150 1Mil 1.167 3.035 3.465 CURB 26.17 0.0569 0.0 43.035 2.448 Vel = 6.68 CURB 0.0 1.481 1T 8.049 30.000 35.047 to 150 0.0 8.049 -3.465 P0C 26.17 0.0264 0.0 38.049 1.005 Vel = 4.87 0.0 26.17 32.587 K Factor = 4.58 Final Calculations - Hazen-Williams Computer Programs by Hydratec Inc. Route 111 W indham N.H. USA 03087 FIRE SUPPRESSION SERVICES 4508 BAXTER ROAD P.O. BOX 37 PRINCETON, MN 55371 763-389-2183 Job Name : ORONO COMMONS Building : 2430-2440 N BLOSSOM CIRCLE Location : LOFT DA-3 System : Contract : Data File : 2430 DA-3.WXF Computer Programs by Hydratec Inc. Route 111 W indham N.H. USA 03087 FIRE SUPPRESSION SERVICES Page 1 ORONO COMMONS Date 062911 HYDRAULIC DESIGN INFORMATION SHEET Name - ORONO COMMONS Date - 5-25-23 Location - LOFT DA-3 Building - 2430-2440 N BLOSSOM CIRCLE System No. - Contractor - FIRE SUPPRESSION SERVICES‚ LLC Contract No. - Calculated By - J GANTER Drawing No. - Construction: (X) Combustible ( ) Non-Combustible Ceiling Height 30' OCCUPANCY - RESIDENTIAL S Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Y Number of Sprinklers Flowing: ( )1 (X)2 ( )4 ( ) S ( )Other T ( )Specific Ruling Made by Date E M Listed Flow at Start Point - 16 Gpm System Type Listed Pres. at Start Point - 16 Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 16 x 18 ( ) Deluge ( ) PreAction E Domestic Flow Added - Gpm Sprinkler or Nozzle S Additional Flow Added - Gpm Make VIKING Model VK486 I Elevation at Highest Outlet - 20 Feet Size 1/2 K-Factor 4.0 G Note: Temperature Rating 155 N Calculation Gpm Required 32.0 Psi Required 49.2 At POC Summary C-Factor Used: Overhead 150 Underground 150 W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 12-1-21 Rated Cap. Cap. T Time of Test - 10:00 AM @ Psi Elev. E Static (Psi) - 61 Elev. R Residual (Psi) - -- Other Well Flow (Gpm) - --- Proof Flow Gpm S Elevation - 2 P Location: WILLOW DRIVE & KELLY PARKWAY P L Source of Information: STATIC PRESSURE GAUGED Y Computer Programs by Hydratec Inc. Route 111 W indham N.H. USA 03087 FIRE SUPPRESSION SERVICESPage 2 ORONO COMMONSDate 062911 10203040E50R60U70S80S90E100R110P12013014015050 100 150 200 250 300 350 400 450FLOW ( N ^ 1.85 )City Water Supply:Demand:C1C2C1 - Static Pressure : 61 C2 - Residual Pressure: 20 C2 - Residual Flow : 500 D1D2D1 - Elevation : 12.127 D2 - System Flow : 32.0184 D2 - System Pressure : 49.168 Hose ( Adj City ) : _______Hose ( Demand ) : _______D3 - System Demand : 32.0184 Safety Margin : 11.578 Water Supply Curve (C)Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 FIRE SUPPRESSION SERVICESPage 3 ORONO COMMONSDate 062911 Fitting Legend Abbrev. Name ½ ¾ 1 1¼ 1½ 2 2½ 3 3½ 4 5 6 8 10 12 14 16 18 20 24 E 90' Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Mil B Ball Milw BB-SC100 2.25 2 2.5 2.25 10 N CPVC 90'Ell Harvel-Spears 7 5 5 6 7 9 12 13 0 0 0 0 0 0 0 0 0 0 0 0 O CPVC Tee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 S Generic Swing Check Valve 4 5 5 7 9 11 14 16 19 22 27 32 45 55 6576 87 98 109 130 T 90' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Fittings Used SummaryComputer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 FIRE SUPPRESSION SERVICES Page 4 ORONO COMMONS Date 062911 Node Elevation K-Fact Pt Pn Flow Density Area Press No.Actual Actual Req. S05 30.0 4 16.04 na 16.02 0.1 160 16.0 S06 30.0 4 16.0 na 16.0 0.1 160 16.0 7 20.0 20.62 na 6 20.0 24.52 na 5 10.25 31.18 na 3 10.25 33.29 na T0R 10.25 37.03 na B0R 2.0 44.15 na CURB -6.0 51.17 na P0C 2.0 49.17 na The maximum velocity is 10.79 and it occurs in the pipe between nodes 7 and 6 Pressure / Flow Summary - STANDARD Computer Programs by Hydratec Inc. Route 111 W indham N.H. USA 03087 FIRE SUPPRESSION SERVICES Page 5 ORONO COMMONS Date 062911 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn S05 16.02 1.101 1O 5.0 0.500 16.037 K Factor = 4.00 to 150 0.0 5.000 4.331 7 16.02 0.0451 0.0 5.500 0.248 Vel = 5.40 0.0 16.02 20.616 K Factor = 3.53 S06 16.00 1.101 1O 5.0 1.330 16.000 K Factor = 4.00 to 150 0.0 5.000 4.331 7 16.0 0.0450 0.0 6.330 0.285 Vel = 5.39 7 16.02 1.101 2N 10.0 14.000 20.616 to 150 0.0 10.000 0.0 6 32.02 0.1625 0.0 24.000 3.900 Vel = 10.79 6 0.0 1.101 1O 5.0 10.000 24.516 to 150 0.0 5.000 4.223 5 32.02 0.1625 0.0 15.000 2.437 Vel = 10.79 5 0.0 1.101 1O 5.0 8.000 31.176 to 150 0.0 5.000 0.0 3 32.02 0.1625 0.0 13.000 2.113 Vel = 10.79 3 0.0 1.101 1O 5.0 13.000 33.289 to 150 1N 5.0 10.000 0.0 T0R 32.02 0.1625 0.0 23.000 3.737 Vel = 10.79 T0R 0.0 1.101 1S 9.563 8.000 37.026 to 150 1Mil 4.303 13.865 3.573 B0R 32.02 0.1625 0.0 21.865 3.553 Vel = 10.79 B0R 0.0 1.265 1E 1.868 40.000 44.152 to 150 1Mil 1.167 3.035 3.465 CURB 32.02 0.0826 0.0 43.035 3.556 Vel = 8.17 CURB 0.0 1.481 1T 8.049 30.000 51.173 to 150 0.0 8.049 -3.465 P0C 32.02 0.0384 0.0 38.049 1.460 Vel = 5.96 0.0 32.02 49.168 K Factor = 4.57 Final Calculations - Hazen-Williams Computer Programs by Hydratec Inc. Route 111 W indham N.H. USA 03087 Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Bulletin 033 June 2020Bulletin 033 June 2020 Model F1 RES LL Residential Sprinklers Types: 1. F1 Res 30 LL Pendent 2. F1 Res 30 LL Recessed Pendent/F2 3. F1 Res 30 LL Recessed Pendent/FP 4. F1 Res 49 LL Pendent 5. F1 Res 49 LL Recessed Pendent/F1 6. F1 Res 49 LL Recessed Pendent/FP 7. F1 Res 58 LL Pendent 8. F1 Res 58 LL Recessed Pendent/F1 9. F1 Res 58 LL Recessed Pendent/FP 10. F1 Res 30 LL CCP Pendent 11. F1 Res 49 LL CCP Pendent 12. F1 Res 58 LL CCP Pendent 13. F1 Res 44 LL HSW 14. F1 Res 44 LL Recessed HSW/F2 15. F1 Res 58 LL HSW 16. F1 Res 58 LL HSW Recessed HSW/F2 17. F1 Res 44 LL SWC Listings & Approvals 1. Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) for Safety to ANSI/ UL1626. 2. Certified by Underwriters Laboratories, Inc. and Under- writers Laboratories of Canada for Health Effects to NSF/ ANSI Standard 61 Annex G (Less than 0.25% Lead Con- tent.) 3. WaterMark certified. WaterMark Certificate Number 23347 Additional Bulletins applicable to all F1RES LL Sprinklers • Wall Wetting - Bulletin 007 • Design and Installation - Bulletin 140 UL Listing Category Residential Automatic Sprinkler UL Guide Number VKKW Patents US Patent No. 6,516,893 applies to the Model F1 Res 49 LL & 58 LL Pendent Sprinklers Other patents pending. F1 Res 30 LL, 49 LL, & 58 LL Recessed Pendent/FP F1 Res 49 LL & 58 LL Recessed Pendent / F1, F1 Res 30 LL Recessed Pendent/F2 F1 Res 44 LL & 58 LL Recessed HSW/F2 F1 Res 30 LL, 49 LL & 58 LL CCP Pendent F1 Res 44 LL SWC Product Description Model F1 Res LL Pendent sprinklers (Figs. 1, 2, 3, & 4) are fast response sprinklers combining excellent durability, high sensitivity glass-bulb and low profile decorative design. The F1 Res LL Horizontal Sidewall sprinklers (Figs. 5, & 6) are equally attractive when above ceiling piping cannot be used. The 3mm glass-bulb pendent sprinklers permit the efficient use of residential water supplies for sprinkler coverage in resi- dential fire protection design. The low flow F1 Res LL sprinklers are specially engineered for fast thermal response to meet the sensitive fire protection application needs of the latest residential market standards (UL 1626 Standard). Upon fire conditions, rising heat causes a sprinkler’s heat-sensitive glass-bulb to shatter, releasing the waterway for water flow onto the deflector, evenly distributing the discharged water to control a fire. Technical Data: • Thermal Sensor: Nominal 3mm glass-bulb • Sprinkler Frame : Brass • Sensitivity: Fast-Response • Sprinklers’ Pressure Rating : 175 psi Factory Hydrostatically Tested to 500 psi • Thread Size: ½” NPT (R½) • K-Factor: 3.0 (Actual) - F1 Res 30 LL Pendent Sprinkler 4.9 (Actual) - F1 Res 49 LL Pendent Sprinkler 5.8 (Actual) - F1 Res 58 LL Pendent & HSW Sprinkler 4.4 (Actual) - F1 Res 44 LL HSW Sprinkler Specifically Listed for use in Multipurpose Systems that serve both domestic water and fire protection. F1 Res 30 LL, 49 LL & 58 LL Pendent F1 Res 44 LL & 58 LL HSW 2. Application Model F1 Res LL sprinklers are cULus Listed in accor- dance with UL 1626 for installation in accordance with NFPA 13, NFPA 13R, and NFPA 13D. Sprinkler systems using Model F1 Res LL sprinklers must be hydraulically designed to provide at least the flow identified in the Tech- nical Data tables in this bulletin. For NFPA 13 installations, the flow per sprinkler must be the greater of: (1) the flow listed in the applicable Technical Data table and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For cover- age area dimensions less than those listed in the Technical Data tables, use the minimum required flow for the next larger max. coverage area listed. Installation Models F1 Res LL sprinklers are to be installed as shown. Model F1, F2 and FP Escutcheons, illustrated herewith, are the only recessed escutcheons to be used with Model F1 Res LL sprinklers. Use of any other recessed escutcheon will void all approvals and warranties. For installing Model F1 Res LL Pendent sprinklers use only the Model W2 sprin- kler Wrench; for installing Models F1 Res LL Recessed Pendent, CCP & SWC sprinklers use only the Model GFR2 sprinkler wrench; for installing Model F1 LL Res Recessed HSW sprinklers use only the Model GFR2 Sprinkler Wrench. Use of wrenches other than those specified may damage these sprinklers. Install F1 Res 44 LL with a ceiling to de- flector distance of 4” - 12”. Flow arrow on deflector must point away from near wall and “Top” marking must face ceiling. Escutcheon*, F1 or F2, Data: Type Adjustment Inch (mm) “A” Inch (mm) Face of fitting to ceiling Inch (mm) F1 3/4 (19.0)Min.=3/4” (19.1) Max.=11/2” (38.1) 3/16 - 15/16 (4.7 - 24.0) F2 1/2 (12.7)Min.=15/16” (23.8) Max.=11/2” (38.1) 3/16 - 11/16 (4.7 - 17.4) * Note: Escutcheons F1 or F2 may be used with Model F1 Res 49 LL & 58 LL Recessed Pendent Sprinkler • Model F1 Res 30 LL, 49 LL & 58 LL Pendent • Model F1 Res 30 LL Recessed Pendent / F2 • Model F1 Res 49 LL & 58 LL Recessed Pendent / F1 Fig. 1 Fig. 2 F1 escutcheon, 3/4” (19mm) adjustment 3. Technical Data: F1Res 30 LL Pendent and Recessed Pendent (SIN RA3311) Thread Size Nominal Orifice Inch (mm) Max. Pressure psi (bar) Sprinkler Temp. Rating Max. Ambient Temp.Actual K Factor Sprinkler Length Inch (mm)°F °C °F °C ½” NPT (R½)21/64” (8.2)175 (12)155 175 68 79 100 38 3.0 (43.2)2.25 (57) Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C) Intermediate Temp. Rating (175°F/79°C)Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) Flow GPM (L/min) Pressure PSI (bar) 12 x 12 (3.6 x 3.6)12 (3.6)8 (30.3)7.0 (0.48)8 (30.3)7.0 (0.48)Smooth Ceilings 1” to 4” (25mm to 100mm) Beamed Ceilings per NFPA 13, 13D, or 13R 8 (2.4)14 x 14 (4.3 x 4.3)14 (4.3)10 (37.8)11 (0.76)10 (37.8)11 (0.76) 16 x 16 (4.9 x 4.9)16 (4.9)13 (49)18.8 (1.3)13 (49)18.8 (1.3) Technical Data: F1Res 49 LL Pendent and Recessed Pendent (SIN RA3316) Thread Size Nominal Orifice Inch (mm) Max. Pressure psi (bar) Sprinkler Temp. Rating Max. Ambient Temp. Actual K Factor Sprinkler Length Inch (mm)°F °C °F °C ½” NPT (R½)7/16” (11)175 (12)155 175 68 79 100 150 38 66 4.9 (70.6)2.25 (57) Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C) Intermediate Temp. Rating (175°F/79°C)Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) Flow GPM (L/min) Pressure PSI (bar) 12 x 12 (3.6 x 3.6)12 (3.6)13 (49)7.0 (0.48)13 (49)7.0 (0.48) Smooth Ceilings 1” to 4” (25mm to 100mm) Beamed Ceilings per NFPA 13, 13D, or 13R 8 (2.4) 14 x 14 (4.3 x 4.3)14 (4.3)13 (49)7.0 (0.48)13 (49)7.0 (0.48) 16 x 16 (4.9 x 4.9)16 (4.9)13 (49)7.0 (0.48)13 (49)7.0 (0.48) 18 x 18 (5.5 x 5.5)18 (5.5)17 (64.3)12 (0.83)17 (64.3)12 (0.83) 20 x 20 (6.1 x 6.1)20 (6.1)20 (75.7)16.7 (1.14)20 (75.7)16.7 (114) Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C) Intermediate Temp. Rating (175°F/79°C)Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) Flow GPM (L/min) Pressure PSI (bar) 12 x 12 (3.6 x 3.6)12 (3.6)15 (57)9.4 (0.65)15 (57)9.4 (0.65) Smooth Ceilings 4” to 8” (100mm to 200mm)8 (2.4) 14 x 14 (4.3 x 4.3)14 (4.3)16 (60.5)10.6 (0.73)16 (60,5)10.6 (0.73) 16 x 16 (4.9 x 4.9)16 (4.9)17 (64.3)12.0 (0.83)17 (64.3)12.0 (0.83) 18 x 18 (5.5 x 5.5)18 (5.5)19 (72)15.0 (1.0)19 (72)15.0 (1.0) 20 x 20 (6.1 x 6.1)20 (6.1)22 (83.2)20.2 (1.4)22 (83.2)20.2 (1.4) FP push-on/thread-off escutcheon 4. • Model F1 Res 30 LL, 49 LL & 58 LL CCP Pendent • Model F1 Res 30 LL, 49 LL & 58 LL Recessed Pendent / FP Fig. 3 Fig. 4 Technical Data: F1Res 58 LL Pendent and Recessed Pendent (SIN RA3313) Thread Size Nominal Orifice Inch (mm) Max. Pressure psi (bar) Sprinkler Temp. Rating Max. Ambient Temp.Actual K Factor Sprinkler Length Inch (mm)°F °C °F °C ½” NPT (R½)½” (13)175 (12)155 175 68 79 100 150 38 66 5.8 (83.5)2.25 (57) Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C) Intermediate Temp. Rating (175°F/79°C)Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) Flow GPM (L/min) Pressure PSI (bar) 12 x 12 (3.6 x 3.6)12 (3.6)16 (61)7.6 (0.53)16 (61)7.6 (0.53) Smooth Ceilings 1” to 4” (25mm to 100mm) Beamed Ceilings per NFPA 13, 13D, or 13R 8 (2.4) 14 x 14 (4.3 x 4.3)14 (4.3)16 (61)7.6 (0.53)16 (61)7.6 (0.53) 16 x 16 (4.9 x 4.9)16 (4.9)16 (61)7.6 (0.53)16 (61)7.6 (0.53) 18 x 18 (5.5 x 5.5)18 (5.5)19 (72)10.8 (0.75)19 (72)10.8 (0,75) 20 x 20 (6.1 x 6.1)20 (6.1)22 (83,3)14.4 (1.0)22 (83.3)14.4 (1.0) 5. Technical Data: F1Res 30 LL CCP Pendent and Recessed Pendent/FP (SIN RA3311) Thread Size Nominal Orifice Inch (mm) Max. Pressure psi (bar) CCP Assembly Temp. Rating Max. Ambient Temp.K Factor Sprinkler Length Inch (mm)°F °C °F °C ½” NPT (R½)21/64” (8.2)175 (12)135 57 100 38 3.0 (43.2)2.25 (57) Max. Coverage area Ft x Ft (m x m) Max. Spac- ing Ft (m) Ordinary Temp. Rating (155°F/68°C)Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) 12 x 12 (3.6 x 3.6)12 (3.6)8 (30.3)7.0 (0.48)Smooth Ceilings 1/2” to 1” (13mm to 25mm) using CCP or FP escutcheon Beamed Ceilings per NFPA 13, 13D, or 13R 8 (2.4) 14 x 14 (4.3 x 4.3)14 (4.3)11 (37.8)13.4 (0.92) Technical Data: F1Res 49 LL CCP Pendent and Recessed Pendent/FP (SIN RA3316) Thread Size Nominal Orifice Inch (mm) Max. Pressure psi (bar) CCP Assembly Temp. Rating Max. Ambient Temp.K Factor Sprinkler Length Inch (mm)°F °C °F °C ½” NPT (R½)7/16” (11)175 (12)135 57 100 38 4.9 (70.6)2.25 (57) Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C)Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) 12 x 12 (3.6 x 3.6)12 (3.6)13 (49)7.0 (0.48) Smooth Ceilings 1/2” to 1” (13mm to 25mm) using CCP or FP escutcheon Beamed Ceilings per NFPA 13, 13D, or 13R 8 (2.4) 14 x 14 (4.3 x 4.3)14 (4.3)13 (49)7.0 (0.48) 16 x 16 (4.9 x 4.9)16 (4.9)14 (53)8.2 (0.56) 18 x 18 (5.5 x 5.5)18 (5.5)18 (68.1)13.5 (0.93) 20 x 20 (6.1 x 6.1)20 (6.1)20 (75.7)16.7 (1.14) Note: Sprinklers shown in Fig. 3 and Fig. 4 are not suitable for installation in ceilings which have positive pressure in the space above. Technical Data: F1Res 58 LL CCP Pendent and Recessed Pendent/FP (SIN RA3313) Thread Size Nominal Orifice Inch (mm) Max. Pressure psi (bar) CCP Assembly Temp. Rating Max. Ambient Temp.K Factor Sprinkler Length Inch (mm)°F °C °F °C ½” NPT (R½)1/2” (13)175 (12)135 57 100 38 5.8 (83.5)2.25 (57) Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C)Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) 12 x 12 (3.6 x 3.6)12 (3.6)16 (61)7.6 (0.53) Smooth Ceilings 1/2” to 1” (13mm to 25mm) using CCP or FP escutcheon Beamed Ceilings per NFPA 13, 13D, or 13R 8 (2.4) 14 x 14 (4.3 x 4.3)14 (4.3)16 (61)7.6 (0.53) 16 x 16 (4.9 x 4.9)16 (4.9)16 (61)7.6 (0.53) 18 x 18 (5.5 x 5.5)18 (5.5)19 (72)10.8 (0.75) 20 x 20 (6.1 x 6.1)20 (6.1)22 (83.3)14.4 (1.0) 6. • Model F1 Res 44 LL & 58 LL HSW • Model F1 Res 44 LL & 58 LL Recessed HSW/F2 F2 escutcheon, 1/2” (13mm) adjustment Technical Data: F1Res 44 LL HSW & HSW/F2 (SIN RA3331) Thread Size Nominal Orifice Inch (mm) Max. Pressure psi (bar) Sprinkler Temp. Rating Max. Ambient Temp. K Factor Sprinkler Length Inch (mm)°F °C °F °C ½” NPT (R½)3/8” (10)175 (12)155 175 68 79 100 150 38 66 4.4 (63)2.45 (62) Escutcheon, F2, Data: Type Adjustment Inch (mm) Face of Fitting to wall Inch (mm) F2 1/2 (13)3/16 - 11/16 (4.7 - 17.4) Max. Coverage area Ft x Ft (m x m) Max. Spac- ing Ft (m) Ordinary Temp. Rating (155°F/68°C) Intermediate Temp. Rating (175°F/79°C)Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) Flow GPM (L/min) Pressure PSI (bar) 12 x 12 (3.6 x 3.6)12 (3.6)12 (45.4)7.5 (0.52)12 (45.4)7.5 (0.52) 4 to 6 (100 to 152) 8 (2.4) 14 x 14 (4.3 x 4.3)14 (4.3)14 (53.0)10.2 (0.71)14 (53.0)10.2 (0.71) 16 x 16 (4.9 x 4,9)16 (4.9)16 (60.6)13.3 (0.92)16 (60.6)13.3 (0.92) 16 x 18 (4.9 x 5.5)16 (4.9)18 (68.1)16.8 (0.53)18 (68.1)16.8 (0.53) 18 x 18 (5.5 x 5.5)18 (5.5)19 (72.0)18.7 (1.29)19 (72.0)18.7 (1.29) 16 x 20 (4.9 x 6.1)16 (4.9)23 (87.1)27.4 (1.89)23 (87.1)27.4 (1.89) 12 x 12 (3.6 x 3.6)12 (3.6)14 (53.0)10.2 (0.71)14 (53.0)10.2 (0.71) 6 to 12 (152 to 305) 14 x 14 (4.3 x 4.3)14 (4.3)16 (60.6)13.3 (0.92)16 (60.6)13.3 (0.92) 16 x 16 (4.9 x 4.9)16 (4.9)17 (64.4)15.0 (1.04)17 (64.4)15.0 (1.04) 16 x 18 (4.9 x 5.5)16 (4.9)20 (75.7)20.7 (1.43)20 (75.7)20.7 (1.43) 16 x 20 (4.9 x 6.1)16 (4.9)23 (87.1)27.4 (1.89)23 (87.1)27.4 (1.89) Fig. 5 7. Technical Data: F1Res 44 LL SWC (SIN RA3331) Thread Size Nominal Orifice Inch (mm) Max. Pressure psi (bar) Cover Temp. Rating Max. Ambient Temp. K Factor Sprinkler Length Inch (mm)°F °C °F °C ½” NPT (R½)3/8” (10)175 (12)135 57 100 38 4.4 (63)2.45 (62) • Model F1 Res 44 LL SWC Fig. 6 Technical Data: F1Res 58 LL HSW & HSW/F2 (SIN RA3333) Thread Size Nominal Orifice Inch (mm) Max. Pressure psi (bar) Sprinkler Temp. Rating Max. Ambient Temp. K Factor Sprinkler Length Inch (mm)°F °C °F °C ½” NPT (R½)1/2” (13)175 (12)155 175 68 79 100 150 38 66 5.8 (83.5)2.45 (62) Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C) Intermediate Temp. Rating (175°F/79°C)Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) Flow GPM (L/min) Pressure PSI (bar) 12 x 12 (3.6 x 3.6)12 (3.6)16 (60.6)7.6 (0.53)16 (60.6)7.6 (0.53) 4 to 6 (100 to 152) 8 (2.4) 14 x 14 (4.3 x 4.3)14 (4.3)18 (68.2)9.7 (0.69)18 (68.2)9.7 (0.69) 16 x 16 (4.9 x 4.9)16 (4.9)21 (79.5)13.2 (0.91)21 (79.5)13.2 (0.91) 16 x 18 (4.9 x 5.5)16 (4.9)25 (94.7)18.6 (1.28)25 (94.7)18.6 (1.28) 16 x 20 (4.9 x 6.1)16 (4.9)29 (109.8)25.0 (1.73)29 (109.8)25.0 (1.73) 12 x 12 (3.6 x 3.6)12 (3.6)22 (83.3)14.4 (1.0)22 (83.3)14.4 (1.0) 6 to 12 (152 to 305) 14 x 14 (4.3 x 4.3)14 (4.3)22 (83.3)14.4 (1.0)22 (83.3)14.4 (1.0) 16 x 16 (4.9 x 4.9)16 (4.9)26 (98.4)20.1 (1.39)26 (98.4)20.1 (1.39) 16 x 18 (4.9 x 5.5)16 (4.9)31 (117.4)28.6 (1.97)31 (117.4)28.6 (1.97) Maintenance Model F1 Res 30 LL, 49 LL, F1 Res 58 LL and F1 Res 44 LL Sprinklers should be inspected and the sprinkler sys- tem maintained in accordance with NFPA 25, 13, 13D, and 13R. Do not clean sprinkler with soap and water, Ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be main- tained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Model F1 Res 30 LL, 49 LL & 58 LL Pendent Sprinkler Specifications Sprinklers shall be [cULus Listed] [WaterMark Certified WMCS] low flow residential pendent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer’s technical data sheets are to be used. Resi- dential sprinklers shall be installed in conformance with the manufacturer’s installation guidelines and the applicable installation standard. Deflector-to-ceiling distance listing shall be 1” to 4” maximum, unless specifically listed other- wise. Sprinkler frame and deflector shall be of bronze frame construction having a ½” NPT thread. Water seal assembly shall consist of a PTFE-coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 3.0, 4.9 and 5.8. Standard fin- ish: [Bronze] [Chrome-plated] [White Polyester] [Special finish– specify]. Residential pendent sprinklers shall be Reliable Model F1 Res 30 LL, 49 LL & 58 LL, SIN RA3311, RA3316 & RA3313 (Bulletin 033). Model F1 Res 49 LL & 58 LL Recessed Pendent/F1 Model F1 Res 30 LL, 49 LL & 58 LL Recessed Pendent/F2 Model F1 Res 30 LL, 49 LL & 58 LL Recessed Pendent/FP Specifications Sprinklers shall be [cULus Listed] [WaterMark Certified WMCS] low flow residential recessed pendent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer’s technical data sheets are to be used. Residential sprinklers shall be installed in con- formance with the manufacturer’s installation guidelines and the applicable installation standard. Deflector-to-ceil- ing distance listing shall be 1” to 4” maximum, unless spe- cifically listed otherwise. Sprinkler frame and deflector shall be of bronze frame construction having a ½” NPT thread. Water seal assembly shall consist of a PTFE-coated Bel- leville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 3.0, 4.9 & 5.8. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish– specify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with ½” adjustment (Model F2)] [with ¾” adjustment (Model F1)] [of push-on and thread off design with ½” adjustment (Model FP)]. Standard finish shall be [brass][bright chrome] [white painted]. Residential recessed pendent sprinklers shall be Reliable [Model F1 Res 30 LL, 49 LL & 58 LL Recessed Pendent/F1] [Model F1 Res 30 LL, 49 LL & 58 LL Recessed Pendent/F2] [Model F1 Res 30 LL, 49 LL & 58 LL Recessed Pendent/FP] SIN RA3311, RA3316 & RA3313 (Bulletin 033). 8. Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C)Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) 12 x 12 (3.6 x 3.6)12 (3.6)13 (49.2)8.7 (0.60) 4 to 6 (100 to 152) 8 (2.4) 14 x 14 (4.3 x 4.3)14 (4.3)14 (53.0)10.2 (0.71) 16 x 16 (4.9 x 4.9)16 (4.9)17 (64.3)15.0 (1.1) 16 x 18 (4.9 x 5.5)16 (4.9)19 (71.8)18.7 (1.13) 16 x 20 (4.9 x 6.1)16 (4.9)23 (87.1)27.4 (1.89) 12 x 12 (3.6 x 3.6)12 (3.6)14 (52.9)10.2 (0.71) 6 to 12 (152 to 305) 14 x 14 (4.3 x 4.3)14 (4.3)15 (56.7)11.7 (0.81) 16 x 16 (4.9 x 4.9)16 (4.9)18 (68.1)16.8 (1.16) 16 x 18 (4.9 x 5.5)16 (4.9)20 (75.6)20.7 (1.43) Technical Data: F1Res 44 LL SWC (SIN RA3331) continued Model F1 Res 30 LL, 49 LL & 58 LL CCP Pendent (Concealed) Specifications Sprinklers shall be [cULus Listed] [WaterMark Certified WMCS] low flow residential concealed sprinklers engi- neered to provide a minimum design density of 0.05 gpm/ ft2 over the listed coverage area. Listed flows as speci- fied by the manufacturer’s technical data sheets are to be used. Residential sprinklers shall be installed in confor- mance with the manufacturer’s installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a ½” NPT thread. Water seal assembly shall consist of a PTFE- coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plas- tic parts, and having a temperature rating of 155°F (68°C). Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a ½” cover plate adjustment. Cover plate temperature rating shall be 135°F (57°C). A plastic protective cap shall be provided and factory in- stalled inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color– specify]. ]. Concealed pendent sprinklers shall be Reliable Model F1 Res 30 LL, 49 LL & 58 LL CCP, SIN RA3311, RA3316 & RA3313 (Bulletin 033). Model F1 Res 44 LL Horizontal Sidewall Residential Sprinkler Specifications Sprinklers shall be [cULus Listed] [WaterMark Certified WMCS] low flow residential horizontal sidewall sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer’s technical data sheets are to be used. Residential sprinklers shall be installed in confor- mance with the manufacturer’s installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a ½” NPT thread. Water seal assembly shall consist of a PTFE- coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plas- tic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 4.4 (62.8). Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish– specify]. Residential hori- zontal sidewall sprinklers shall be Reliable Model F1 Res 44 LL, SIN RA3331 (Bulletin 033). Model F1 Res 44 LL Recessed Horizontal Sidewall Sprinkler Specifications Use description for the Model F1 Res 44 horizontal side- wall sprinkler with the following modifications: Replace “horizontal sidewall sprinkler” with “recessed horizontal sprinkler.” Add: Recessed escutcheon assembly shall be a steel, two-piece escutcheon with ½” adjustment (Model F2). Standard finish shall be [brass][bright chrome] [white painted] [Special finish– specify]. Residential recessed horizontal sidewall sprinklers shall be Reliable Model F1 Res 44 LL/F2, SIN RA3331 (Bulletin 033). Standard Finishes Sprinkler F1, F2, FP Escutcheons Cover Plates Bronze Chrome Plated White and Black Polyester Coated Brass Bright Chrome Plated White Painted White Painted Chrome Special Application Finishes Sprinkler F1, F2, Escutcheons Cover Plates Bright Brass Black Plated Black Paint Off White Satin Chrome Bright Brass Black Plated Black Paint Off White Satin Chrome Bright Brass Black Plated Black Paint Off White Satin Chrome (1) Other finishes and colors are available on special order. Consult factory for details. Note: Paint or any other coating applied over the factory finish will void all approvals and warranties. Ordering Information Specify: 1. Sprinkler Model 2. Sprinkler Type 3. Temperature Rating 4. Sprinkler Finish 5. Escutcheon Finish 6. Cover Plate Finish Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Manufactured by Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 06/20 P/N 9999970411 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years.