Loading...
HomeMy WebLinkAbout08-08-2023 septic maintenance inspectionENDE SEPTIC SERVICE OPERATIONAL CHECKLIST Service provided on: 08/08/2023 Client: Cinda Collins Service provided by: Ende Septic Service Employee: Tristan Ende Address: 650 Big Island Orono, MN 55331 1. Type: 2 - 1000 gallon septic tanks, 1000 gallon pump tank 2. Conditions at the tank a. Evaluate presence of odor within 10 ft of perimeter of system: NONE b. Source of odor, if present: 3. Tank description a. Material: Plastic -infiltrator tanks b. Capacity: 2000 GALLON c. Compartmented No d. Capacities for pump tank: 1000 GALLON 4. Tank access a. Access location: Inlet b. Located at grade. YES c. If `No', how deep is lid buried. N/A d. Risers on tank. YES e. Evidence of infiltration in risers. NO f. Lids securely fastened. YES g. Lid in operable condition. YES 5. Alarm(s) a. Alarm(s) present. YES b. Audio alarm operational. YES c. Visual alarm operational. N/A d. Remote telemetry operational. N/A e. Electronic monitoring operational. N/A 6. Current tank operating conditions a. Liquid level relative to outlet: 45 INCHES b. Maximum liquid level of tank (invert of inlet pipe): 48 in c. Height at which alarm is activated as measured from invert of inlet: 20 in d. Evidence liquid level has been higher. NO e. Evidence liquid level dropped without pumping. NO f. Evidence of continuous inflow. NO 2. X Acceptable ❑ Unacceptable 4. X Acceptable ❑ Unacceptable 5. X Acceptable ❑ Unacceptable 6. X Acceptable ❑ Unacceptable h. Presence of flocculant in clear zone. YES i. Evaluation of lavers in tank: TANK NUMBER Scum (in) Clear Zone (in) Sludge (in) Percent Full c. Compartment baffle in place. Depth Color * Depth Color Depth Color f. If screened, percent plugged: 1 2" Brown 45" Clear 7" Black 20% 2 *Color Choices: ] Clear ❑ Flocced ❑ Milky Black ❑ Brown ❑ Mustard ❑ Gray White 7. Tank pumping recommended. Recommended pump out in 2024 8. Baffles currently structurally sound. YES a. Inlet baffle in place. YES b. Outlet baffle in place. YES c. Compartment baffle in place. N/A d. Effluent screen. NO e. Is screen accessible from ground surface. N/A f. If screened, percent plugged: N/A g. Was screen cleaned. NO 9. Comments: 8. X Acceptable ❑ Unacceptable