Loading...
HomeMy WebLinkAbout06-27-2023 Septic Maintenance InspectionENDE SEPTIC SERVICE OPERATIONAL CHECKLIST Service provided on: 06/27/2023 Client: Tom Kolar Service provided by: Ende Septic Service Employee: Tristan Ende Address: 180 Big Island Orono, MN 55331 1. Type: 1000 gallon septic tank, 1000 gallon pump tank 2. Conditions at the tank a. Evaluate presence of odor within 10 ft of perimeter of system: NONE b. Source of odor, if present: 3. Tank description a. Material: Plastic b. Capacity: 1000 GALLON c. Compartmented No d. Capacities for compartmented system: 4. Tank access a. Access location: Inlet b. Located at grade. YES c. If `No', how deep is lid buried. N/A d. Risers on tank. YES e. Evidence of infiltration in risers. NO f. Lids securely fastened. YES g. Lid in operable condition. YES 5. Alarm(s) a. Alarm(s) present. YES b. Audio alarm operational. YES c. Visual alarm operational. N/A d. Remote telemetry operational. N/A e. Electronic monitoring operational. N/A 6. Current tank operating conditions a. Liquid level relative to outlet: 44 INCHES b. Maximum liquid level of tank (invert of inlet pipe): 47 in c. Height at which alarm is activated as measured from invert of inlet: 25 in d. Evidence liquid level has been higher. NO e. Evidence liquid level dropped without pumping. NO f. Evidence of continuous inflow. NO 2. X Acceptable ❑ Unacceptable 4. X Acceptable ❑ Unacceptable 5. X Acceptable ❑ Unacceptable 6. X Acceptable ❑ Unacceptable h. Presence of flocculant in clear zone. i. Evaluation of lavers in tank: NO TANK NUMBER Scum (in) Clear Zone (in) Sludge (in) Percent Full c. Compartment baffle in place. Depth Color* Depth Color De th Color f. If screened, percent plugged: 1 2" Brown 34" Clear 8" Black 22% 2 *Color Choices: ] Clear ❑ Flocced ❑ Milky Black -1 Brown ❑ Mustard ❑ Gray ❑ White 7. Tank pumping recommended. Recommended pump out in 2024 8. Baffles currently structurally sound. YES a. Inlet baffle in place. YES b. Outlet baffle in place. YES c. Compartment baffle in place. N/A d. Effluent screen. NO e. Is screen accessible from ground surface. N/A f. If screened, percent plugged: N/A 8. X Acceptable ❑ Unacceptable g. Was screen cleaned. NO 9. Comments: New pump, on/off float and alarm float installed during visit. Pump vault filter cleaned during visit.