HomeMy WebLinkAboutM20-000009 - mechanicalFrom: oronoinspector@ci.orono.mn.us Sent: 02/27/2020 - 08:39 AM To: jason@selectmechanical.com CC: Subject: Inspection Report Individual CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952)249-4616 Inspection Report 1400 BRACKETTS POINT RD Permit Number: M20-000009 Site Address: 1400 BRACKETTS POINT RD, WAYZATA, MN 55391 Property Owner: BRACKETT POINT PROPERTY LLC Description: New home HVAC system Inspection Date: 02/27/2020 Inspection Type: Mechanical - Rough In Inspection Results: Work Satisfactory: Proceed Inspection Status: General Comment 1. Lower level heat loop for pub, cheese room, theatre and bowling . Holding applied pressure ok to cover. Jason R. Sincerely, Roger Peitso Building Official 952-249-4625 To schedule your inspections please call: (952) 249-4600 To schedule your inspection online Click Here CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY! From: oronoinspector@ci.orono.mn.us Sent: 04/27/2020 - 09:14 AM To: jason@selectmechanical.com CC: Subject: Inspection Report Individual Inspection Report 1400 BRACKETTS POINT RD Permit Number: M20-000009 Site Address: 1400 BRACKETTS POINT RD, WAYZATA, MN 55391 Property Owner: BRACKETT POINT PROPERTY LLC Description: New home HVAC system Inspection Date: 04/27/2020 Inspection Type: Mechanical - Rough In Inspection Results: Work Satisfactory: Proceed Inspection Status: General Comment CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952) 249-4616 1. In floor heat run two zones three manifolds holding applied pressure protected at concrete penetrations. Golf simulator and games area. Jason R. Sincerely, Roger Peitso Building Official 952-249-4625 To schedule your inspections please call: (952) 249-4600 To schedule your inspection online Click Here CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY! From: oronoinspector@ci.orono.mn.us Sent: 05/01/2020 - 03:12 PM To: jason@selectmechanical.com CC: Subject: Inspection Report Individual CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952) 249-4616 Inspection Report 1400 BRACKETTS POINT RD Permit Number: M20-000009 Site Address: 1400 BRACKETTS POINT RD, WAYZATA, MN 55391 Property Owner: BRACKETT POINT PROPERTY LLC Description: New home HVAC system Inspection Date: 05/01/2020 Inspection Type: Mechanical - Rough In Inspection Results: Work Satisfactory: Proceed Inspection Status: General Comment 1. In floor air test for hunting room, lower level garage ,and lower level yard storage ok. Sincerely, Roger Peitso Building Official 952-249-4625 To schedule your inspections please call: (952) 249-4600 To schedule your inspection online Click Here CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY! From: oronoinspector@ci.orono.mn.us Sent: 05/07/2020 - 09:50 AM To: jason@selectmechanical.com CC: Subject: Inspection Report Individual CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952) 249-4616 Inspection Report 1400 BRACKETTS POINT RD Permit Number: M20-000009 Site Address: 1400 BRACKETTS POINT RD, WAYZATA, MN 55391 Property Owner: BRACKETT POINT PROPERTY LLC Description: New home HVAC system Inspection Date: 05/07/2020 Inspection Type: Mechanical - Rough In Inspection Results: Correct Check at Building Final Inspection Status: General Comment 1. Label exterior intake and exhaust balance and label HRV 2. Gas line manometer is holding 3. Bath fans - ok 4. Kitchen. Hood - ok 5. 6. Duct air test received Sincerely, oyL Roger Peitso Building Official 952-249-4625 To schedule your inspections please call: (952) 249-4600 To schedule your inspection online Click Here CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY! From: oronoinspector@ci.orono.mn.us Sent: 05/07/2020 - 09:53 AM To: jason@selectmechanical.com CC: Subject: Inspection Report Individual CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952) 249-4616 Inspection Report 1400 BRACKETTS POINT RD Permit Number: M20-000009 Site Address: 1400 BRACKETTS POINT RD, WAYZATA, MN 55391 Property Owner: BRACKETT POINT PROPERTY LLC Description: New home HVAC system Inspection Date: 05/07/2020 Inspection Type: Mechanical - Rough In Inspection Results: Correct Check at Building Final Inspection Status: General Comment 1. Air test for in floor heat loop sport court area OK holding applied pressure. Sincerely, Roger Peitso Building Official 952-249-4625 To schedule your inspections please call: (952) 249-4600 To schedule your inspection online Click Here CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY! From: oronoinspector@ci.orono.mn.us Sent: 05/07/2020 - 09:54 AM To: jason@selectmechanical.com CC: Subject: Inspection Report Individual CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952) 249-4616 Inspection Report 1400 BRACKETTS POINT RD Permit Number: M20-000009 Site Address: 1400 BRACKETTS POINT RD, WAYZATA, MN 55391 Property Owner: BRACKETT POINT PROPERTY LLC Description: New home HVAC system Inspection Date: 05/07/2020 Inspection Type: Mechanical - Rough In Inspection Results: Work Satisfactory: Proceed Inspection Status: General Comment 1. Air test for in floor heat loop sport court area OK holding applied pressure. Sincerely, Roger Peitso Building Official 952-249-4625 To schedule your inspections please call: (952) 249-4600 To schedule your inspection online Click Here CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY! From: oronoinspector@ci.orono.mn.us Sent: 08/04/2020 - 09:35 AM To: jason@selectmechanical.com CC: Subject: Inspection Report Individual Inspection Report 1400 BRACKETTS POINT RD Permit Number: M20-000009 Site Address: 1400 BRACKETTS POINT RD, WAYZATA, MN 55391 Property Owner: BRACKETT POINT PROPERTY LLC Description: New home HVAC system Inspection Date: 08/04/2020 Inspection Type: Mechanical -Air Test Inspection Results: Work Satisfactory: Proceed Inspection Status: General Comment CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952) 249-4616 1. Heat loop for front entry and exterior snowmelt Holding applied pressure OK to cover holding applied pressure OK to cover. Jason R. Sincerely, Roger Peitso Building Official 952-249-4625 To schedule your inspections please call: (952) 249-4600 To schedule your inspection online Click Here CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY! From: oronoinspector@ci.orono.mn.us Sent: 10/22/2020 - 09:37 AM To: jason@selectmechanical.com CC: Subject: Inspection Report Individual CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952) 249-4616 Inspection Report 1400 BRACKETTS POINT RD Permit Number: M20-000009 Site Address: 1400 BRACKETTS POINT RD, WAYZATA, MN 55391 Property Owner: BRACKETT POINT PROPERTY LLC Description: New home HVAC system Inspection Date: 10/22/2020 Inspection Type: Mechanical -Air Test Inspection Results: Permit Finaled Inspection Status: General Comment 1. Jason R. 2. Gas line manometer is holding 3. Bath fans - ok 4. Kitchen. Hood - ok 5. HRV - ERV balanced Sincerely, Roger Peitso Building Official 952-249-4625 To schedule your inspections please call: (952) 249-4600 To schedule your inspection online Click Here CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY! From: oronoinspector@ci.orono.mn.us Sent: 10/22/2020 - 09:40 AM To: jason@selectmechanical.com CC: Subject: Inspection Report Individual CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952) 249-4616 Inspection Report 1400 BRACKETTS POINT RD Permit Number: M20-000009 Site Address: 1400 BRACKETTS POINT RD, WAYZATA, MN 55391 Property Owner: BRACKETT POINT PROPERTY LLC Description: New home HVAC system Inspection Date: 10/22/2020 Inspection Type: Mechanical -Air Test Inspection Results: Work Satisfactory: Proceed Inspection Status: General Comment 1. Jason R. 2. Photos of pressure gauge received. Sincerely, ,--5 - Roger Peitso Building Official 952-249-4625 To schedule your inspections please call: (952) 249-4600 To schedule your inspection online Click Here CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY! From: oronoinspector@ci.orono.mn.us Sent: 11/25/2020 - 12:10 PM To: jason@selectmechanical.com CC: Subject: Inspection Report Individual CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952) 249-4616 Inspection Report 1400 BRACKETTS POINT RD Permit Number: M20-000009 Site Address: 1400 BRACKETTS POINT RD, WAYZATA, MN 55391 Property Owner: BRACKETT POINT PROPERTY LLC Description: New home HVAC system Inspection Date: 11/25/2020 Inspection Type: Mechanical - Rough In Inspection Results: Work Satisfactory: Proceed Inspection Status: General Comment 1. Air test garage #1 holding ok Sincerely, Jason Rech Building Inspector 952-249-4625 To schedule your inspections please call: (952) 249-4600 To schedule your inspection online Click Here CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY! From: oronoinspector@ci.orono.mn.us Sent: 01/18/2021 - 12:09 PM To: jason@selectmechanical.com CC: Subject: Inspection Report Individual Inspection Report 1400 BRACKETTS POINT RD Permit Number: M20-000009 Site Address: 1400 BRACKETTS POINT RD, WAYZATA, MN 55391 Property Owner: BRACKETT POINT PROPERTY LLC Description: New home HVAC system Inspection Date: 01/18/2021 Inspection Type: Mechanical - Rough In Inspection Results: Correct Work & Proceed Inspection Status: General Comment CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952) 249-4616 1. Mechanical R.I. inspection for second floor cold storage, live in quarters, second -floor girls bedrooms. Main floor kitchen and guest suite. Salon and North Hall not complete.finish second floor bath fan terminations. Jason R. 2. Supplies, returns-ok 3. Bath fans/ insul.-ok Sincerely, Jason Rech Building Inspector 952-249-4625 To schedule your inspections please call: (952) 249-4600 To schedule your inspection online Click Here CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY! From: jr.metrowest@gmail.com Sent: 01/26/2021 - 01:40 PM To: jason@selectmechanical.com CC: Subject: Inspection Report Individual CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952) 249-4616 Inspection Report 1400 BRACKETTS POINT RD Permit Number: M20-000009 Site Address: 1400 BRACKETTS POINT RD, WAYZATA, MN 55391 Property Owner: BRACKETT POINT PROPERTY LLC Description: New home HVAC system Inspection Date: 01/26/2021 Inspection Type: Mechanical - Rough In Inspection Results: Work Satisfactory: Proceed Inspection Status: General Comment 1. supply and return duct work for salon and north hall complete. Sincerely, Jason Rech Building Inspector 952-249-4625 To schedule your inspections please call: (952) 249-4600 To schedule your inspection online Click Here CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY! From: oradmin@mnspect.com Sent: 03/24/2021 - 01:21 PM To: jason@selectmechanical.com,Ted@JKSons.com CC: Subject: Inspection Report Individual Inspection Report 1400 BRACKETTS POINT RD Permit Number: M20-000009 Site Address: 1400 BRACKETTS POINT RD, WAYZATA, MN 55391 Property Owner: BRACKETT POINT PROPERTY LLC Description: New home HVAC system Inspection Date: 03/24/2021 Inspection Type: Mechanical -Air Test Inspection Results: CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952) 249-4616 Inspection Status: General Comment 1. Section a hydronic piping holding applied pressure 2. Section a gas lines holding applied pressure. 3. Fill penetrations between floors. Inspection Status: Complete 1. Air test on 2-2" gas lines in mechanical room lower level near garage (50psi) 1 -for boilers, 1 -for rest of house. Section B 2. Air test 2 -3/4" gas lines in mechanical room near bowling alley (50psi) section B 3. Air test 2- 3/4" gas lines for ranges in main kitchen and butler kitchen. Section B mechanical room half way between bowling alley and sport court. Sincerely, TY TURNQUIST BUILDING INSPECTIONS 952-442-7520 To schedule your inspections please call: (952) 442-7520 CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY! From: oradmin@mnspect.com Sent: 04/05/2021 - 01:04 PM To: jason@selectmechanical.com CC: Subject: Inspection Report Individual CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952) 249-4616 Inspection Report 1400 BRACKETTS POINT RD Permit Number: M20-000009 Site Address: 1400 BRACKETTS POINT RD, WAYZATA, MN 55391 Property Owner: BRACKETT POINT PROPERTY LLC Description: New home HVAC system Inspection Date: Inspection Type: Mechanical - Rough In Inspection Results: Correct Work & Proceed Inspection Status: General Comment 1. Finish remaining runs for fans 2. Provide engineering approval and updated plans for all field changes Sincerely, TY TURNQUIST BUILDING INSPECTIONS 952-442-7520 To schedule your inspections please call: (952) 442-7520 CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY! From: oradmin@mnspect.com Sent: 04/29/2021 - 10:22 AM To: Ted@JKSons.com CC: Subject: Inspection Report Individual CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952) 249-4616 Inspection Report 1400 BRACKETTS POINT RD Permit Number: M20-000009 Site Address: 1400 BRACKETTS POINT RD, WAYZATA, MN 55391 Property Owner: BRACKETT POINT PROPERTY LLC Description: New home HVAC system Inspection Date: 04/29/2021 Inspection Type: Mechanical -Air Test Inspection Results: Work Satisfactory: Proceed Inspection Status: Complete 1. Area Al hydronic air test appears ok Sincerely, TY TURNQUIST BUILDING INSPECTIONS 952-442-7520 To schedule your inspections please call: (952) 442-7520 CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY! From: oradmin@mnspect.com Sent: 04/29/2021 - 02:15 PM To: jason@selectmechanical.com CC: Subject: Inspection Report Individual CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952) 249-4616 Inspection Report 1400 BRACKETTS POINT RD Permit Number: M20-000009 Site Address: 1400 BRACKETTS POINT RD, WAYZATA, MN 55391 Property Owner: BRACKETT POINT PROPERTY LLC Description: New home HVAC system Inspection Date: 04/29/2021 Inspection Type: Mechanical -Air Test Inspection Results: Work Satisfactory: Proceed Inspection Status: Complete 1. North tower hydronic and library Al hydronic air test appear ok 2. Area Al hydronic air test appears ok Sincerely, TY TURNQUIST BUILDING INSPECTIONS 952-442-7520 To schedule your inspections please call: (952) 442-7520 CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY! From: oradmin@mnspect.com Sent: 04/29/2021 - 02:16 PM To: Ted@JKSons.com CC: Subject: Inspection Report Individual CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952) 249-4616 Inspection Report 1400 BRACKETTS POINT RD Permit Number: M20-000009 Site Address: 1400 BRACKETTS POINT RD, WAYZATA, MN 55391 Property Owner: BRACKETT POINT PROPERTY LLC Description: New home HVAC system Inspection Date: 04/29/2021 Inspection Type: Mechanical -Air Test Inspection Results: Work Satisfactory: Proceed Inspection Status: Complete 1. North tower hydronic and library Al hydronic air test appear ok 2. Area Al hydronic air test appears ok Sincerely, TY TURNQUIST BUILDING INSPECTIONS 952-442-7520 To schedule your inspections please call: (952) 442-7520 CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY! From: oradmin@mnspect.com Sent: 06/14/2021 - 09:17 AM To: jason@selectmechanical.com,Ted@JKSons.com CC: Subject: Inspection Report Individual Inspection Report 1400 BRACKETTS POINT RD Permit Number: M20-000009 Site Address: 1400 BRACKETTS POINT RD, WAYZATA, MN 55391 Property Owner: BRACKETT POINT PROPERTY LLC Description: New home HVAC system Inspection Date: 06/14/2021 Inspection Type: Mechanical - Rough In Inspection Results: Work Satisfactory: Proceed Inspection Status: Complete CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952) 249-4616 1. Visual duct inspection completed on room 013, 003, 012, 016, 041,004,005,043 and check bath by stairway 1. Also looked at finished venting bath section c above exercise room . Ryan Sincerely, TY TURNQUIST BUILDING INSPECTIONS 952-442-7520 To schedule your inspections please call: (952) 442-7520 CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY! From: oradmin@mnspect.com Sent: 06/14/2021 - 09:18 AM To: jason@selectmechanical.com,Ted@JKSons.com CC: Subject: Inspection Report Individual CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952) 249-4616 Inspection Report 1400 BRACKETTS POINT RD Permit Number: M20-000009 Site Address: 1400 BRACKETTS POINT RD, WAYZATA, MN 55391 Property Owner: BRACKETT POINT PROPERTY LLC Description: New home HVAC system Inspection Date: 06/14/2021 Inspection Type: Mechanical - Rough In Inspection Results: Work Satisfactory: Proceed Inspection Status: Complete 1. 2nd level c hydonic complete except mitch's office. Ryan Sincerely, TY TURNQUIST BUILDING INSPECTIONS 952-442-7520 To schedule your inspections please call: (952) 442-7520 CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY! From: gnelson@ci.oron o.mn.us Sent: 01/27/2022 - 10:18 AM To: jason@selectmechanical.com CC: gnelson@ci.oron o.mn.us Subject: Inspection Report Individual CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952) 249-4616 Inspection Report 1400 BRACKETTS POINT RD Permit Number: M20-000009 Site Address: 1400 BRACKETTS POINT RD, WAYZATA, MN 55391 Property Owner: BRACKETT POINT PROPERTY LLC Description: New home HVAC system Inspection Date: 01/27/2022 Inspection Type: Gas Manometer Inspection Results: Work Satisfactory: Proceed Inspection Status: Review Comment 1. Manometer for boilers Sincerely, Gary Nelson 952-242-4442 To schedule your inspections please call: (952) 249-4600 CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY! From: gnelson@ci.oron o.mn.us Sent: 04/27/2022 - 09:40 AM To: jason@selectmechanical.com CC: gnelson@ci.orono.mn.us Subject: Inspection Report Individual CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952) 249-4616 Inspection Report 1400 BRACKETTS POINT RD Permit Number: M20-000009 Site Address: 1400 BRACKETTS POINT RD, WAYZATA, MN 55391 Property Owner: BRACKETT POINT PROPERTY LLC Description: New home HVAC system Inspection Date: 04/27/2022 Inspection Type: Gas Manometer Inspection Results: Inspection Passed: Proceed Inspection Status: Review Comment 1. 2inch gas line from meter to generator. Sincerely, Gary Nelson 952-242-4442 To schedule your inspections please call: (952) 249-4600 CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY! From: negan@ci.orono.mn.us Sent: 07/01/2022 - 11:43 AM To: jason@selectmechanical.com,negan@ci.orono.mn.us CC: Subject: Inspection Report Email - Failed Inspection Report 1400 BRACKETTS POINT RD Permit Number: M20-000009 Site Address: 1400 BRACKETTS POINT RD, WAYZATA, MN 55391 Property Owner: BRACKETT POINT PROPERTY LLC Description: New home HVAC system Inspection Date: 07/01/2022 Inspection Type: Mechanical - Final Inspection Results: Inspection Failed: Reinspect CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952) 249-4616 Inspection Status: Re -inspection Required 1. All bath fans must be tested 2. All manifold penetrations must be fire blocked 3. Ductwork on both sides of bridge must be fire blocked 4. All access panels are required to be gasketed Inspection Status: Review Comment 1. Energy seal report/Blower door/energy certificates/Balance report are required at final inspection. Duct static pressure must be below 3. 2. Provide truss verification that trusses in boiler room are able to hold additional weight of hanging pipes. 3. Did gas leak test on all gas connections - compliant. Sincerely, 1P�u �� Nicole Egan 952-249-4625 To schedule your inspections please call: (952) 249-4600 CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY! Certificate of Product Ratinas AHRI Certified Reference Number: 5220990 Date : 07-11-2022 Model Status : Active Old AHRI Reference Number : Product :Water -to -Air and Brine -to -Air Model Number: WGTV/WGTH064B*E Brand Name : DAIKIN Rated as follows in accordance with the latest edition of ANSI/AHRI/ASHRAE/ISO 13256-1 Water -source heat pumps -- Testing and rating for performance -- Part 1: Water -to -air and Brine -to -air heat pumps and subject to rating accuracy by AHRI-sponsored, independent, third party testing: Full Load Part Load1 Part Load2 Part Load3 Air Flow Rate - Cooling: 2000 1750 Air Flow Rate - Heating: 2000 1750 WLHP (Water -Loop Heat Pumps) Cooling Capacity (Btuh) 64800/64800 48200/48200 Cooling EER Rating (Btuh/watt) 17.40/17.40 19.70/19.70 Cooling Fluid Flow Rate (gpm) 16.00 16.00 Heating Capacity (Btuh) 76100/76100 53800/53800 Heating Cop (watt/watt) 5.20/5.20 5.80/5.80 Heating Fluid Flow Rate (gpm) 16.00 16.00 GLHP (Ground -Loop Heat Pumps) Cooling Capacity (Btuh) 67100/67100 52200/52200 Cooling EER Rating (Btuh/Watt) 19.70/19.70 28.00/28.00 Cooling Fluid Flow Rate (gpm) 16.00 16.00 Heating Capacity (Btuh) 47000/47000 38300/38300 Heating COP (watt/watt) 3.90/3.90 4.30/4.30 Heating Fluid Flow Rate (gpm) 16.00 16.00 Indoor Blower Motor Fan Type : ECM Sold In? : USA t"Active" Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale; OR new models that are being marketed but are not yet being prod uced."Production Stopped" Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still selling or offering for sale. Ratinas that are accompanied by WAS indicate an involuntary re -rate. The new Dublished ratina is shown alona with the Drevious (i.e. WAS) ratina. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, x4m personal and confidential reference. AIR-CONDITIONING, HEATING, CERTIFICATE VERIFICATION & REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at www.ahrid!rectory.org, click on "Verify Certificate" link we make life better" and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above, and the Certificate No., which is listed at bottom right. ©Air -Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 133020308840049014 Certificate of Product Ratinas AHRI Certified Reference Number: 5220987 Date : 07-11-2022 Model Status : Active Old AHRI Reference Number : Product :Water -to -Air and Brine -to -Air Model Number: WGTV/WGTH049B*E Brand Name : DAIKIN Rated as follows in accordance with the latest edition of ANSI/AHRI/ASHRAE/ISO 13256-1 Water -source heat pumps -- Testing and rating for performance -- Part 1: Water -to -air and Brine -to -air heat pumps and subject to rating accuracy by AHRI-sponsored, independent, third party testing: Full Load Part Load1 Part Load2 Part Load3 Air Flow Rate - Cooling: 1600 1400 Air Flow Rate - Heating: 1600 1400 WLHP (Water -Loop Heat Pumps) Cooling Capacity (Btuh) 48900/48900 36900/36900 Cooling EER Rating (Btuh/watt) 16.70/16.70 19.60/19.60 Cooling Fluid Flow Rate (gpm) 12.20 12.20 Heating Capacity (Btuh) 55300/55300 40800/40800 Heating Cop (watt/watt) 5.30/5.30 6.00/6.00 Heating Fluid Flow Rate (gpm) 12.20 12.20 GLHP (Ground -Loop Heat Pumps) Cooling Capacity (Btuh) 50600/50600 39600/39600 Cooling EER Rating (Btuh/Watt) 19.20/19.20 28.20/28.20 Cooling Fluid Flow Rate (gpm) 12.20 12.20 Heating Capacity (Btuh) 35900/35900 29200/29200 Heating COP (watt/watt) 4.00/4.00 4.40/4.40 Heating Fluid Flow Rate (gpm) 12.20 12.20 Indoor Blower Motor Fan Type : ECM Sold In? : USA t"Active" Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale; OR new models that are being marketed but are not yet being prod uced."Production Stopped" Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still selling or offering for sale. Ratinas that are accompanied by WAS indicate an involuntary re -rate. The new Dublished ratina is shown alona with the Drevious (i.e. WAS) ratina. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, x4m personal and confidential reference. AIR-CONDITIONING, HEATING, CERTIFICATE VERIFICATION & REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at www.ahrid!rectory.org, click on "Verify Certificate" link we make life better" and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above, and the Certificate No., which is listed at bottom right. ©Air -Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 133020307976766072 Certificate of Product Ratinas AHRI Certified Reference Number: 5220980 Date : 07-11-2022 Model Status : Active Old AHRI Reference Number : Product :Water -to -Air and Brine -to -Air Model Number: WGTV/WGTH038B*E Brand Name : DAIKIN Rated as follows in accordance with the latest edition of ANSI/AHRI/ASHRAE/ISO 13256-1 Water -source heat pumps -- Testing and rating for performance -- Part 1: Water -to -air and Brine -to -air heat pumps and subject to rating accuracy by AHRI-sponsored, independent, third party testing: Full Load Part Load1 Part Load2 Part Load3 Air Flow Rate - Cooling: 1250 1090 Air Flow Rate - Heating: 1250 1090 WLHP (Water -Loop Heat Pumps) Cooling Capacity (Btuh) 39000/39000 28300/28300 Cooling EER Rating (Btuh/watt) 17.60/17.60 20.20/20.20 Cooling Fluid Flow Rate (gpm) 9.00 9.00 Heating Capacity (Btuh) 44400/44400 32600/32600 Heating Cop (watt/watt) 5.60/5.60 6.40/6.40 Heating Fluid Flow Rate (gpm) 9.00 9.00 GLHP (Ground -Loop Heat Pumps) Cooling Capacity (Btuh) 40200/40200 30500/30500 Cooling EER Rating (Btuh/Watt) 20.10/20.10 28.90/28.90 Cooling Fluid Flow Rate (gpm) 9.00 9.00 Heating Capacity (Btuh) 28100/28100 22500/22500 Heating COP (watt/watt) 4.20/4.20 4.70/4.70 Heating Fluid Flow Rate (gpm) 9.00 9.00 Indoor Blower Motor Fan Type : ECM Sold In? : USA t"Active" Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale; OR new models that are being marketed but are not yet being prod uced."Production Stopped" Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still selling or offering for sale. Ratinas that are accompanied by WAS indicate an involuntary re -rate. The new Dublished ratina is shown alona with the Drevious (i.e. WAS) ratina. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, x4m personal and confidential reference. AIR-CONDITIONING, HEATING, CERTIFICATE VERIFICATION & REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at www.ahrid!rectory.org, click on "Verify Certificate" link we make life better" and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above, and the Certificate No., which is listed at bottom right. ©Air -Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 133020306828013816 Certificate of Product Ratinas AHRI Certified Reference Number: 5220707 Date : 07-11-2022 Model Status : Active Old AHRI Reference Number : Product :Water -to -Air and Brine -to -Air Model Number: WGTV/WGTH026B*E Brand Name : DAIKIN Rated as follows in accordance with the latest edition of ANSI/AHRI/ASHRAE/ISO 13256-1 Water -source heat pumps -- Testing and rating for performance -- Part 1: Water -to -air and Brine -to -air heat pumps and subject to rating accuracy by AHRI-sponsored, independent, third party testing: Full Load Part Load1 Part Load2 Part Load3 Air Flow Rate - Cooling: 800 700 Air Flow Rate - Heating: 800 700 WLHP (Water -Loop Heat Pumps) Cooling Capacity (Btuh) 26400/26400 19800/19800 Cooling EER Rating (Btuh/watt) 16.75/16.75 18.24/18.24 Cooling Fluid Flow Rate (gpm) 6.50 6.50 Heating Capacity (Btuh) 29300/29300 21800/21800 Heating Cop (watt/watt) 5.70/5.70 6.40/6.40 Heating Fluid Flow Rate (gpm) 6.50 6.50 GLHP (Ground -Loop Heat Pumps) Cooling Capacity (Btuh) 27600/27600 22000/22000 Cooling EER Rating (Btuh/Watt) 19.27/19.27 26.79/26.79 Cooling Fluid Flow Rate (gpm) 6.50 6.50 Heating Capacity (Btuh) 18100/18100 15100/15100 Heating COP (watt/watt) 4.10/4.10 4.60/4.60 Heating Fluid Flow Rate (gpm) 6.50 6.50 Indoor Blower Motor Fan Type : ECM Sold In? : USA t"Active" Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale; OR new models that are being marketed but are not yet being prod uced."Production Stopped" Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still selling or offering for sale. Ratinas that are accompanied by WAS indicate an involuntary re -rate. The new Dublished ratina is shown alona with the Drevious (i.e. WAS) ratina. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, x4m personal and confidential reference. AIR-CONDITIONING, HEATING, CERTIFICATE VERIFICATION & REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at www.ahrid!rectory.org, click on "Verify Certificate" link we make life better" and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above, and the Certificate No., which is listed at bottom right. ©Air -Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 133020305733324205 Certificate of Product Ratinas AHRI Certified Reference Number: 8656970 Date : 07-11-2022 Model Status : Active Old AHRI Reference Number : Product :Water -to -Air and Brine -to -Air Model Number : WGCV012J1*G/J*T Brand Name : DAIKIN Rated as follows in accordance with the latest edition of ANSI/AHRI/ASHRAE/ISO 13256-1 Water -source heat pumps -- Testing and rating for performance -- Part 1: Water -to -air and Brine -to -air heat pumps and subject to rating accuracy by AHRI-sponsored, independent, third party testing: Air Flow Rate - Cooling: Air Flow Rate - Heating: WLHP (Water -Loop Heat Pumps) Cooling Capacity (Btuh) Cooling EER Rating (Btuh/watt) Cooling Fluid Flow Rate (gpm) Heating Capacity (Btuh) Heating Cop (watt/watt) Heating Fluid Flow Rate (gpm) GWHP (Ground Water -Heat Pumps) Cooling Capacity (Btuh) Cooling EER Rating (Btuh/Watt) Cooling Fluid Flow Rate (gpm) Heating Capacity (Btuh) Heating COP (watt/watt) Heating Fluid Flow Rate (gpm) GLHP (Ground -Loop Heat Pumps) Cooling Capacity (Btuh) Cooling EER Rating (Btuh/Watt) Cooling Fluid Flow Rate (gpm) Heating Capacity (Btuh) Heating COP (watt/watt) Heating Fluid Flow Rate (gpm) Indoor Blower Motor Fan Type : ECM Sold In? : USA, Canada Full Load Part Load1 Part Load2 Part Load3 400 11700 14.20 3.00 8700 3.30 3.00 t"Active" Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale; OR new models that are being marketed but are not yet being prod uced."Production Stopped" Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still selling or offering for sale. Ratinas that are accompanied by WAS indicate an involuntary re -rate. The new Dublished ratina is shown alona with the Drevious (i.e. WAS) ratina. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, x4m personal and confidential reference. AIR-CONDITIONING, HEATING, CERTIFICATE VERIFICATION & REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at www.ahrid!rectory.org, click on "Verify Certificate" link we make life better" and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above, and the Certificate No., which is listed at bottom right. ©Air -Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 133020304079258467 4S,SS*svL 2920 Centre Pointe Drive . Roseville, MN 55113 . PHONE: (651)481-8000 . FAX:(651)481-8621 FOR APPROVAL Bracketts Point House PROJECT NAME ISG (I & S Engineering) - Mankato ENGINEER Select Mechanical CONTRACTOR Daikin - Heat Pum EQUIPMENT 23 81 46 SPECIFICATION SECTION Rob .Maloney 8/27/2021 SALESPERSON DATE -Ad&t ewer 824890 PREPARED BY SVL JOB NO. Goods will conform to approved/reviewed submittals Technical Data Sheet for 2 Ton Horizontal - LH Job Name Brackets Point House Date 8/30/2021 Submitted By Tim Harris Software Version 10.20 Unit Tag HP -007, HP -010 W GTH 0261 208-230/60/1 800 Model Number: WGTH026 Unit Type: SmartSource - 2 -Stage Approval: ETL, CETL, AHRI Configuration Refrigerant Type Horizontal R -410A 6.00 25409 17.5 = 17874 Refrigerant Weight Loop Temperature Range 56.0 oz Ground Loop (Geothermal) Air & Fluid Flow Airflow Total External Static Pressure Fluid Flow Fluid Type Glycol Concentration Altitude Full (Part) Full (Part) 0.30 (15txtSESPFull) 6.00 gpm / 3.00 800(700)CFM propylene Glycol 25.0% 0 ft inH20 gpm/ton Cooling Performance Fluid Temperature Air Temperature Capacity Heat of EER @ Fluid Entering Leaving Entering Leaving Total Sensible Rejection design Pressure 'F °F Dry Bulb Wet Bulb Dry Bulb Wet Bulb Btu/hr Btu/hr Drop Performance °F °F °F °F ft H20 Full Load 77.0 87.5 75.0 63.0 52.8 51.6 25409 19301 30364 17.5 5.90 Part Load 68.0 75.5 70.0 59.0 51.2 48.9 18714 14300 21656 21.7 6.01 Heating Performance Fluid Temperature Air Temperature Capacity Heat of COP @ design Fluid Pressure Entering Leaving Entering Leaving Total Absorption Drop °F °F Dry Bulb Dry Bulb Btu/hr Btu/hr ft Hzo Performance °F °F Full Load 32.0 27.5 70.0 90.6 17874 13049 3.7 6.59 Part Load 41.0 37.1 70.0 89.8 15043 11300 4.0 6.42 *System WPD is calculated without the autoflow valve as the CV of an autoflow valve varies dependent on the system WPD. As long as the WPD is >3 psid, the autoflow valve will provide the selected GPM flowrate. Electrical Unit Voltage Minimum Voltage Total Unit Full Load Current Total Unit MCA 208-230/60/1 197 v 14.7 A 17.6 A Compressor RLA Compressor LRA Motor FLA Maximum Recommended Fuse Size / HACR Breaker Size 11.7A 58.3A 3.0A 25A *Short -Circuit Current = 5 kA rms symmetrical, 600 V maximum Job Number: LL20FE Job Name: Brackets Point House Page Prepared Date: 8/30/2021 4 of 26 www.DaikinApplied.com Technical Data Sheet for 2 Ton Horizontal - LH Unit Length Height Width Weight Connection Shipping Operating Water 63.3 in 19.3 in 22.4 in 289 Ib 254 Ib 0.75 in Fan Motor Type Motor Horsepower ECM Constant CFM 0.33 hp Controls Unit Control: Microtech III Control Transformer: Standard 50 VA Transformer Thermostat/Sensor Control: Thermostat Control Unit Airflow Configuration Return Air Location: Left Hand Discharge Air Location: Straight Cabinet Finish: Galvanized Drain Pan Material Primary: Stainless Steel Filters Filter Rack Type: Standard 2 -inch 4 -Sided Filter Type: Disposable (Quantity) Filter Dimensions: (1) 17 In x 34 In x 2 In Insulation Compressor: Premium Compressor Compartment: 1/2 inch Fiberglass, Skin -faced Air Compartment: 3/4 inch Acoustic Open Cell Foam (Soundcoat) Piping: Insulated Piping Miscellaneous Sound Package: Premium Coil Treatment: None Unit warranty: 4 Yr Refrigerant Circuit Only Extended Parts Warranty, 1st Yr Labor Allowance Condensate 0.75 in All equipment is rated and certified in accordance with AHRI / ISO 13256-1 and tested, investigated, and determined to comply with the requirements of the standards for Heating and Cooling Equipment UL -1995 for the United States and CAN/CSA-C22.2 NO.236 for Canada. Optional Part Number Description 910193131 Programmable/Non-Programmable, 2H/2C, Wi-Fi, ACO, touchscreen 910157029 Hose, Kit Auto Flow, Strainer, Ball Vlv 0.75" x 3ft, 6.0 GPM Job Number: LL20FE Page Prepared Date: Job Name: Brackets Point House 5 of 26 8/30/2021 www.DaikinApplied.com WGTH_26-32_LH-RH_ED-SD_Specs_Drawing for 2 Ton Horizontal Certified Drawing WGTH 26.2 LH-RH Ed-Sd Sp$cs the VftWr Source Hest wnp prasluct represented on th.a tloeument will confoim M. the dlrawirlge erre Group= WSHP spec4cations getout bebw- Inacrardenea with the express, wirimn Limited Warranty. Purchaaer'ssccep- Type_ WGTH Hurinantel lanoe of this -drawing cart0es that the conforming equipment meats the order meofiratOns. No Changes mey be made to INE uocumeat with Cut the prior, express, written authorization of rhe manufaml-er. Date: July 2017 mart ourcellii) TWo Stage Horizontal W HP Model WGTH — Sire 026 & 432 (Left-hand & right-hand return, end & straight discharge) Lite FraN Lain -Nana RNWM Law Vhkagc Ri I;4Mn6Rekum Fro k vcnx-i LNoteAj SlraghL Dishv9e �J AW FPT fl++� Condrrrsale Clira m sillieraUeiph[dhcfiaW Fnd D199hgrgq Orale Coin" inti w erd disrtlarge �P� PY O � � A� L*n Raphe -EM 113Ig4elpr4ja #ick :itmalghl.orxharge FronlYlew W4-FFT Cw+9ana m D•Nh Choose ether sLaghl CaneCGon Fs1d DhchmW disrhe "Kid I r UNI Hanger Eleackel.Dsti 1# W Fx 4 Y rn V IQs or NG lafne P F FSI AP � � O L h F get RwWm - Eud 0taehoNe- I . — N .1 '. — Left Return • Slraiyrrt Olscharge Vlew p Ai � ILght Return - Slraigkt Discharge View Front S � 4 L v T COI CMPAP Frorrt CMP AP T LaRalfnd natum Air Call CommbR RightAa d Retum Aiiir toll 4paniaq Table ?_ Cabinet dimensions GTN•Flotlfonlal UnitOwel-all Cabinet Dimensions In inches (rnmI Hanger BracketLowion Dimemiwm A= Width a = Length C = Hlalgm Ylr I 74 Y -Iz7IM 22A(" (561} 63.30- (160) 19.30' 1490) 62.15 {1579] 23.90 (507) 16.54 4474) I . — N .1 '. — Left Return • Slraiyrrt Olscharge Vlew p Ai � ILght Return - Slraigkt Discharge View Front S � 4 L v T COI CMPAP Frorrt CMP AP T LaRalfnd natum Air Call CommbR RightAa d Retum Aiiir toll 4paniaq Table ?_ Cabinet dimensions GTN•Flotlfonlal UnitOwel-all Cabinet Dimensions In inches (rnmI Hanger BracketLowion Dimemiwm A= Width a = Length C = Hlalgm Ylr I 74 Y 102E, iLu 22A(" (561} 63.30- (160) 19.30' 1490) 62.15 {1579] 23.90 (507) 16.54 4474) MOMS. rirf dimensfons witNrt 3 0,90 fgahes (2,5 mm). Legend: CW AP = Compressor Compermrant Access Paoai CAP= Corltrof Access RwO FW AP = Farr i4l WAccass Pana! DAII %2017 Daikin Appred • mmw.EhkkinAANled.cam • (6013) 432-1342 ` nrH 26,2 LNd2H EMD $pag a Pogo i of 2 Job Number: LL20FE Page Prepared Date: 8/30/2021 Job Name: Brackets Point House 4 of 25 www.DaikinApplied.com WGTH_26-32_LH-RH_ED-SD_Specs_Drawing for 2 Ton Horizontal SmartSource Two Stage Horizontal WSHP PA*41 WGTH— Sl2is 029 & U32 (L&R-ha rid & right -Nand r9turh, 4s rid & stroilghl dl#aki3rge) Table 2_ ftlnyl G4+1eePiforls 41MOMIOns Piping Coneedl;ans In Irwhns Jrnm} EleNrleal C*mmmliarn In inches jrnni� GTH d E Marixonlal J K L Ua1l SuPRhr ROWn F Ccndaniato Drain ]l4- FPT FI Low Vollal9e' swhnYn Line VbRaW 026. 0371 2.59 (9 9) 13.39 (340) 1.57 {40) 4.29 009) 1.-94 (0 2 57 (65) 7 39 (167) 9 W (2521 NOW.'' 511pply�rro ri�t�rr, �1Wr►� tarsni�tfborrs = 3'4" (99 rtxHl FPf Low vel a owning = 718"(.22 mm) 4ffameter. Lme vctlage Dpenrng = 7-I (29 mm) dsmeler. Tabfs 3, Discharge duct 6 ratum air coif opaning dFnTBnsiuns Mote 4i! dix7 dimensions are referenced ho m the aftsl'de edge of the Mange. GTM horizontal unit - 2' filter ra€k assembly d duct OMjw dimensions M13M (71.; mm) Table 4: 2' fflrer rack assembly 6 duct coffer dlmensfvn9 Unit Slze Z" II" 025, 932 15.45 (3921 32.±.1 {szst Note, ' Opharral 4' r9br rads = 4.70' (104 nrun) Fgure 7_ !teary -duty hanger bravkvls (sizes 026-832) 97E'TFreuded Dlssharge Alr Duet Gonnoolon In Inches �mrnl ReturnlnchCaai nvrn) ng In AirQTH HorUontal 'By Olhere] N R �� Uihrafim k�kl78r $qrk 4 1 pyW Unll M -0 P Q T U V LeR-hand I�lght-hand Leflaielitl IZlghl-hand 429, 032 4,A1 9.24 (157} 2.71 (6* 713.39 9.32 4.41 2.71 (6% 8.2%1 [157} 32-50 15.b6 1.47 1.43 (112) (267) (237) {112} 1828) {342) X511) {49) Mote 4i! dix7 dimensions are referenced ho m the aftsl'de edge of the Mange. GTM horizontal unit - 2' filter ra€k assembly d duct OMjw dimensions M13M (71.; mm) Table 4: 2' fflrer rack assembly 6 duct coffer dlmensfvn9 Unit Slze Z" II" 025, 932 15.45 (3921 32.±.1 {szst Note, ' Opharral 4' r9br rads = 4.70' (104 nrun) Fgure 7_ !teary -duty hanger bravkvls (sizes 026-832) 97E'TFreuded Rod HewirD� ly 'By Olhere] &a[ke[ �� Uihrafim k�kl78r $qrk 4 1 pyW 1 iex tills @Dmhb } Washcr (By Olhmu) DAIKI �D 2017 Delkln Applied - www.DalklnApphad_com - (80d) 432-1342 '2�19'(69mm} See too" —.989' l75 rim) .d59' 171,8 rrrrr} Z" ,1139` 421.8 mm} WC, TH 7ir-p 1 K-RH Fn -$r) 5p4p r Pi;yP? 4r2 Job Number: LL20FE Page Prepared Date: 8/30/2021 Job Name: Brackets Point House 5 of 25 www.DaikinApplied.com • • Information Technical Job Name Brackets Point House Date 8/30/2021 Submitted By Tim Harris Software Version 10.20 Unit Tag HP -201, HP -208, HP -209, HP -005 Model Number: WGCV012 Unit Type: SmartSource Compact - Single Stage Approval: ETL, CETL, AHRI Configuration Refrigerant Type Refrigerant Weight Loop Temperature Range Vertical R -410A 21.5 oz Ground Loop (Geothermal) Air & Fluid Flow Airflow Total External Static Pressure Fluid Flow Fluid Type Glycol Concentration Altitude 396 CFM 0.30 inH2O 3.00 gpm / 3.00 Propylene Glycol 25.0% 0 ft gpm/ton Cooling Performance Fluid Temperature Air Temperature Capacity Heat of EER @ Fluid Entering Leaving Entering Leaving Total Sensible Rejection design Pressure °F °F Dry Bulb Wet Bulb Dry Bulb Wet Bulb Btu/hr Btu/hr Btu/hr Drop °F °F °F °F ft H2O 77.0 86.5 75.0 63.0 56.9 53.3 10871 7759 13676 13.2 6.23 Heating Performance Fluid Temperature Air Temperature Capacity Heat of COP @ design Fluid Pressure Entering Leaving Entering Leaving Total Absorption Drop °F °F Dry Bulb Dry Bulb Btu/hr Btu/hr ft H20 °F °F 32.0 28.2 70.0 89.0 8187 5444 3.0 6.95 Unit Voltage Minimum Voltage Electrical Total Unit Full Load Current Total Unit MCA 208-230/60/1 197 v 5.5 A 6.7 A Compressor RLA Compressor LRA Motor FLA Maximum Recommended Fuse Size / HACR Breaker Size 4.6A 27.9A 0.9A 15A *Short -Circuit Current = 5 kA rms symmetrical, 600 V maximum Unit Depth Height Width 19.0 in 24.0 in 19.0 in Fan Motor Type ECM Constant Torque Job Number: LL20FE Job Name: Brackets Point House Weight Connection Shipping Operating Water Condensate 133 Ib 105 Ib 0.50 in 0.75 in Motor Horsepower 0.10 hp Page Prepared Date: 8/30/2021 6 of 26 www.DaikinApplied.com Controls Unit Control: Control Transformer: Thermostat / Sensor Control: Unit Airflow Configuration Return Air Location: Discharge Air Location: Drain Pan Material Microtech III Standard 50 VA Transformer Thermostat Control Right Hand Top Primary: Stainless Steel Filters Filter Rack Type: Filter Type: (Quantity) Filter Dimensions: Insulation Compressor Compartment: Air Compartment: Piping: Miscellaneous 2 -inch 4 -Sided 2 -inch MERV 8 (1) 12 inx16inx2in 1 inch Fiberglass, Skin -faced 1 inch Fiberglass, Skin -faced Insulated Piping Sound Package: Optional Sound Package Coil Treatment: None Unit warranty: 4 Yr Refrigerant Circuit Only Extended Parts Warranty, 1st Yr Labor Allowance All equipment is rated and certified in accordance with AHRI / ISO 13256-1 and tested, investigated, and determined to comply with the requirements of the standards for Heating and Cooling Equipment UL 60335-2- 40 Version 2 for the United States and CAN/CSA-C22.2 NO. 60335-2-40 Version 2 for Canada. Optional Part Number Description 106582906 Hose, Kit, Auto Flow, Strainer, Ball Vlv, 0.50" x 2ft, 3.0 GPM Job Number: LL20FE Page Prepared Date: 8/30/2021 Job Name: Brackets Point House 7 of 26 www.DaikinApplied.com Drawings(1) for 1 Ton Vertical - RH 314 VIEW - RIGHT HAND RETURN UNIT TOP VIEW w� �z 9.3 ¢ z xw / �O 0 4.9 • 2.5 4.8 As• • 19A�19.0 17.3 1.8 2.0 RETURN 12 1.7 + .0 0 12.0 9.325 [C] 2.7 9.0 ]B] q D [E] 1.3 FRONT VIEW 1.6 RIGHT VIEW NOTES [A] -High Volt Pwr Entry 1.1 DIA [B] -Low Volt Pwr Entry 08 DIA [C] -Condensate Drain 3!4" FPT [D] -Supply Water 112" FPT [E] - Return Water 112" FPT [F] -Unit Front Service Clearance 24 Product Drawing UInitTag: 1TonVertical-RH FDAIKIN Product: Project Name: Brackets Point House 13600 Industrial Park Blvd. Minneapolis, MN 55441 Model: WGCV012 Sales office: Schwa b-VolIhaber-Lubratt, www.DaikinApplied.com Software Version: 10.20 Sales Engineer: Addi Steinert Aug. 30, 2021 Ver/Rev: Sheet 1 of 1 Scale: NTS Tolerance: +/-0.25" Dwg Units: (in) No change to this drawing may be made unless approved in writing by Daikin Applied. Purchaser must determine that the equipment is fit and sufficient for the job specifications. Job Number: LL20FE Page 24 11.1 Job Name: 16.5 13.6 OPENING 9.9 6 of 25 www.DaikinApplied.com Job Number: LL20FE Page Prepared Date: 8/30/2021 Job Name: Brackets Point House 6 of 25 www.DaikinApplied.com Job Name Brackets Point House Date 8/30/2021 Submitted By Tim Harris Software Version 10.20 Unit Tag HP -011, HP -107, HP -111, HP -138, HP -205, HP -238 OverviewUnit Model Voltage Airflow Fluid Flow .. Number V/Hz/Phase CFM gpM .. WGTV0261 208-230/60/1 800 6.00 25409 Model Number: WGTV026 Unit Type: SmartSource - 2 -Stage Approval: ETL, CETL, AHRI Configuration Refrigerant Type Refrigerant Weight Vertical R -410A 56.0 oz 17.5 = 17874 Loop Temperature Range Ground Loop (Geothermal) Air & Fluid Flow Airflow Total External Static Pressure Fluid Flow Fluid Type Glycol Concentration Altitude Full (Part) Full (Part) 0.30 (15txtSESPFull) 6.00 gpm / 3.00 800(700)CFM propylene Glycol 25.0% 0 ft inH20 gpm/ton Cooling Performance Fluid Temperature Air Temperature Capacity Heat of EER @ Fluid Entering Leaving Entering Leaving Total Sensible Rejection design Pressure 'F °F Dry Bulb Wet Bulb Dry Bulb Wet Bulb Btu/hr Btu/hr Drop Performance °F °F °F °F ft H20 Full Load 77.0 87.5 75.0 63.0 52.8 51.6 25409 19301 30364 17.5 5.90 Part Load 68.0 75.5 70.0 59.0 51.2 48.9 18714 14300 21656 21.7 6.01 Heating Performance Fluid Temperature Air Temperature Capacity Heat of COP @ design Fluid Pressure Entering Leaving Entering Leaving Total Absorption Drop °F °F Dry Bulb Dry Bulb Btu/hr Btu/hr ft Hzo Performance °F °F Full Load 32.0 27.5 70.0 90.6 17874 13049 3.7 6.59 Part Load 41.0 37.1 70.0 89.8 15043 11300 4.0 6.42 *System WPD is calculated without the autoflow valve as the CV of an autoflow valve varies dependent on the system WPD. As long as the WPD is >3 psid, the autoflow valve will provide the selected GPM flowrate. Electrical Unit Voltage Minimum Voltage Total Unit Full Load Current Total Unit MCA 208-230/60/1 197 v 14.7 A 17.6 A Compressor RLA Compressor LRA Motor FLA Maximum Recommended Fuse Size / HACR Breaker Size 11.7A 58.3A 3.0A 25A *Short -Circuit Current = 5 kA rms symmetrical, 600 V maximum Job Number: LL20FE Page Prepared Date: 8/30/2021 Job Name: Brackets Point House 8 of 26 www.DaikinApplied.com Unit Depth Height Width Weight Connection Shipping Operating Water Condensate 26.0 in 48.0 in 22.4 in 265 Ib 231 Ib 0.75 in 0.75 in Fan Motor Type Motor Horsepower ECM Constant CFM 0.33 hp Controls Unit Control: Microtech III Control Transformer: Standard 50 VA Transformer Thermostat/Sensor Control: Thermostat Control Unit Airflow Configuration Return Air Location: Left Hand Discharge Air Location: Top Cabinet Finish: Galvanized Drain Pan Material Primary: Stainless Steel Filters Filter Rack Type: Standard 2 -inch 4 -Sided Filter Type: Disposable (Quantity) Filter Dimensions: (1) 28 In x 22 In x 2 In Insulation Compressor: Premium Compressor Compartment: 1/2 inch Fiberglass, Skin -faced Air Compartment: 3/4 inch Acoustic Open Cell Foam (Soundcoat) Piping: Insulated Piping Miscellaneous Sound Package: Premium Coil Treatment: None Unit warranty: 1st Year Labor Allowance All equipment is rated and certified in accordance with AHRI / ISO 13256-1 and tested, investigated, and determined to comply with the requirements of the standards for Heating and Cooling Equipment UL -1995 for the United States and CAN/CSA-C22.2 NO.236 for Canada. Optional Part Number Description 669481901 Hose, Kit, w/Ball Valves, Strainer, 0.75" x 2ft Job Number: LL20FE Page Job Name: Brackets Point House 9 of 26 Prepared Date: 8/30/2021 www.DaikinApplied.com Job Name Brackets Point House Date 8/30/2021 Submitted By Tim Harris Software Version 10.20 Unit Tag HP -015, HP -017, HP -021, HP -126, HP -121, HP -219 OverviewUnit Model Voltage Airflow Fluid Flow .. Number V/Hz/Phase CFM gpM .. WGTV0261 208-230/60/1 800 6.00 25409 Model Number: WGTV026 Unit Type: SmartSource - 2 -Stage Approval: ETL, CETL, AHRI Configuration Refrigerant Type Refrigerant Weight Vertical R -410A 56.0 oz 17.5 = 17874 Loop Temperature Range Ground Loop (Geothermal) Air & Fluid Flow Airflow Total External Static Pressure Fluid Flow Fluid Type Glycol Concentration Altitude Full (Part) Full (Part) 0.30 (15txtSESPFull) 6.00 gpm / 3.00 800(700)CFM propylene Glycol 25.0% 0 ft inH20 gpm/ton Cooling Performance Fluid Temperature Air Temperature Capacity Heat of EER @ Fluid Entering Leaving Entering Leaving Total Sensible Rejection design Pressure 'F °F Dry Bulb Wet Bulb Dry Bulb Wet Bulb Btu/hr Btu/hr Drop Performance °F °F °F °F ft H20 Full Load 77.0 87.5 75.0 63.0 52.8 51.6 25409 19301 30364 17.5 5.90 Part Load 68.0 75.5 70.0 59.0 51.2 48.9 18714 14300 21656 21.7 6.01 Heating Performance Fluid Temperature Air Temperature Capacity Heat of COP @ design Fluid Pressure Entering Leaving Entering Leaving Total Absorption Drop °F °F Dry Bulb Dry Bulb Btu/hr Btu/hr ft Hzo Performance °F °F Full Load 32.0 27.5 70.0 90.6 17874 13049 3.7 6.59 Part Load 41.0 37.1 70.0 89.8 15043 11300 4.0 6.42 *System WPD is calculated without the autoflow valve as the CV of an autoflow valve varies dependent on the system WPD. As long as the WPD is >3 psid, the autoflow valve will provide the selected GPM flowrate. Electrical Unit Voltage Minimum Voltage Total Unit Full Load Current Total Unit MCA 208-230/60/1 197 v 14.7 A 17.6 A Compressor RLA Compressor LRA Motor FLA Maximum Recommended Fuse Size / HACR Breaker Size 11.7A 58.3A 3.0A 25A *Short -Circuit Current = 5 kA rms symmetrical, 600 V maximum Job Number: LL20FE Page Prepared Date: 8/30/2021 Job Name: Brackets Point House 10 of 26 www.DaikinApplied.com Unit Depth Height Width Weight Connection Shipping Operating Water Condensate 26.0 in 48.0 in 22.4 in 265 Ib 231 Ib 0.75 in 0.75 in Fan Motor Type Motor Horsepower ECM Constant CFM 0.33 hp Controls Unit Control: Microtech III Control Transformer: Standard 50 VA Transformer Thermostat/Sensor Control: Thermostat Control Unit Airflow Configuration Return Air Location: Right Hand Discharge Air Location: Top Cabinet Finish: Galvanized Drain Pan Material Primary: Stainless Steel Filters Filter Rack Type: Standard 2 -inch 4 -Sided Filter Type: Disposable (Quantity) Filter Dimensions: (1) 28 In x 22 In x 2 In Insulation Compressor: Premium Compressor Compartment: 1/2 inch Fiberglass, Skin -faced Air Compartment: 3/4 inch Acoustic Open Cell Foam (Soundcoat) Piping: Insulated Piping Miscellaneous Sound Package: Premium Coil Treatment: None Unit warranty: 1st Year Labor Allowance All equipment is rated and certified in accordance with AHRI / ISO 13256-1 and tested, investigated, and determined to comply with the requirements of the standards for Heating and Cooling Equipment UL -1995 for the United States and CAN/CSA-C22.2 NO.236 for Canada. Optional Part Number Description 669481901 Hose, Kit, w/Ball Valves, Strainer, 0.75" x 2ft Job Number: LL20FE Page Job Name: Brackets Point House 11 of 26 Prepared Date: 8/30/2021 www.DaikinApplied.com WGTV_26-32_LH-RH_Specs_Drawing for 2 Ton Vertical i ■ i VVGTV 26-32 LH-RH Speca Ie Hest wnp product represented on thea dixument will c*nfotm to- the drawlrbp and GFaup= WSHP wt below- nacmrdenee Wththe express, wmiten Llmlted Warranty. Pumhaaer'saccep Type= V4CsT11 Vertical irrg cartes that the coirfarming equipment rnaeta the order spearfi[atians. Na chaegaa ihis doournent without the prior, axpress, written i hor¢auon of the manufaklumr. Date: October 2013 SmartSourcer" Two Stage Vertical WSHP Model WG1V — Size 026 & 032 (Left-hand & right-hand return) �Pw� P�i Tap `,'lew- LOt RelUrn LAA Side VhM-L.eR Rddum Toblio 'i: Overag cebkmf dmnskns Fran[ 0 Grail Jhi rap Yew - RIgrd Raqurn I Froi RW Side %lex - Went Rehlrn F/411t niMand ReLura Wrn tlnil XMIU1l!!R FU AP C i.rf 1AS, {q7} Line 41^^9 rC L � k;n Frank View Low LUltape Ope im (Nope 31 GTV-%ardoel Will: Oyarell Gabinal Riman4j;;r.F In mGhas (mm) A =Width 1 B = f}epth C = Iivlyhl 926,032 22.4tr 069) 1 26.Or (OW j 48.W (1 2111) Notes: AR dfinerrsionr wjYhrn t 0.10 irwhes (2.3 mm) - Legend, CWPAIP=G*moreswComparirrrenlAc essPaniW CAP = Cankar Access Fan431 FUA.P = Fan Mow Access Pana DAIKI %2013 Daikin Appiad • • 1800) 492-1342 WON 2632 LKRH Spins f Page 7 at 2 Job Number: LL20FE Page Prepared Date: 8/30/2021 Job Name: Brackets Point House 7 of 25 www.DaikinApplied.com WGTV_26-32_LH-RH_Specs_Drawing for 2 Ton Vertical SmarkSource'M Two Stage Vertical VVSHP Model WGTV— Siz-a 1)26 & 0.32 JLL%fl-hand & right-hand return Table 2_ ✓ Wrm & electrical Gcmrrecdnns dimerrsiuns Notes." Supply and mrum pffArg comeXions = 314"(10 alert) FPT Law voltage opening = 718' (22mm) dameter Line "age Opening = 7• W (29 mm) dMnieror. Cvndenaar6 dram = 314` (79 mm) FPT Tsbfe 3_ Uischarue duct mKar & return air coil unenina dimensions GTv Plpinp Cannactlons In inchem (mm} EleGulcel Connections In aches fmm� 13TV Verticel 6 E F H J K L Uolt Supply Drtupbrt`ealrr Desup eehealer Return t:bnd6nsaiw Lour Yaltage' Between Line Valtagr' water supply Water keturn Drain 3u1" iZR, 0$2' 2.59 M) 6.139 {1 7D) 9613 (246) 1 13"(W-0 17.391442) 2.45 (62� 9.53 (214} 11.07 {297} Notes." Supply and mrum pffArg comeXions = 314"(10 alert) FPT Law voltage opening = 718' (22mm) dameter Line "age Opening = 7• W (29 mm) dMnieror. Cvndenaar6 dram = 314` (79 mm) FPT Tsbfe 3_ Uischarue duct mKar & return air coil unenina dimensions GTv blscharga Duct Collar Connection In Inchea {mmj ReturnAlr Cal I Openlug In Inches (enrol vortical Unit M N O r q R s 1 r u 02C, oat 5.75 (14$) 9.37 {213) 1 D.391204) 8.321237] 10.55 (269) 2U(731 20.50 {5211 25.44 (64ti) 1.132 (41 ) N4re, AN" dimen=s ns ars referenced hen cutsade edge of The- flange, Tabfe4 Flllerrack assembly d rerum mirduct cogardImerrsfons Unit size V I W I X Y z 928, R37 29,49' 073] 1 24,79' 1529} 1 22 W2- (5751 28,15 (715) 19.49 (Q*) 2" Filter Rask 2'151} LLl Y. EM r _ . 40� Optional a" Fingr Rack 11421 WGTv 26,32 W RH Spxs r Papa 2 of 2 Job Number: LL20FE Page Prepared Date: 8/30/2021 Job Name: Brackets Point House 8 of 25 www.DaikinApplied.com Job Name Brackets Point House Date 8/30/2021 Submitted By Tim Harris Software Version 10.20 Unit Tag HP -003, HP -132, HP -232 W GTV0381 208-230/60/1 1400 Model Number: WGTV038 Unit Type: SmartSource - 2 -Stage Approval: ETL, CETL, AHRI Configuration Refrigerant Type Vertical R -410A 9.00 38148 17.1" 28062 Refrigerant Weight Loop Temperature Range 77.0 oz Ground Loop (Geothermal) Air & Fluid Flow Airflow Total External Static Pressure Fluid Flow Fluid Type Glycol Concentration Altitude Full (Part) Full (Part) 0.30 (15txtSESPFull) 9.00 gpm / 3.00 1400(1250)CFM propylene Glycol 25.0% Oft inH20 gpm/ton Cooling Performance Fluid Temperature Air Temperature Capacity Heat of EER @ Fluid Entering Leaving Entering Leaving Total Sensible Rejection design Pressure 'F °F Dry Bulb Wet Bulb Dry Bulb Wet Bulb Btu/hr Btu/hr Drop Performance °F °F °F °F ft H20 Full Load 77.0 87.6 75.0 63.0 55.9 53.4 38148 29024 45740 17.1 10.43 Part Load 68.0 75.2 70.0 59.0 53.6 51.0 26865 22308 31236 21.0 10.62 Heating Performance Fluid Temperature Air Temperature Capacity Heat of COP @ design Fluid Pressure Entering Leaving Entering Leaving Total Absorption Drop °F °F Dry Bulb Dry Bulb Btu/hr Btu/hr ft H20 Performance °F °F Full Load 32.0 27.2 70.0 88.5 28062 20566 3.7 11.64 Part Load 41.0 36.9 70.0 87.0 23065 17538 4.2 11.34 *System WPD is calculated without the autoflow valve as the CV of an autoflow valve varies dependent on the system WPD. As long as the WPD is >3 psid, the autoflow valve will provide the selected GPM flowrate. Electrical Unit Voltage Minimum Voltage Total Unit Full Load Current Total Unit MCA 208-230/60/1 197 v 20.3 A 24.1 A Compressor RLA Compressor LRA Motor FLA Maximum Recommended Fuse Size / HACR Breaker Size 15.3A 83.0A 5.0A 35A *Short -Circuit Current = 5 kA rms symmetrical, 600 V maximum Job Number: LL20FE Job Name: Brackets Point House Page Prepared Date: 8/30/2021 12 of 26 www.DaikinApplied.com Unit Depth Height Width Weight Connection Shipping Operating Water Condensate 32.5 in 50.5 in 25.0 in 344 Ib 313 Ib 0.75 in 0.75 in Fan Motor Type Motor Horsepower ECM Constant CFM 0.50 hp Controls Unit Control: Microtech III Control Transformer: Standard 50 VA Transformer Thermostat/Sensor Control: Thermostat Control Unit Airflow Configuration Return Air Location: Left Hand Discharge Air Location: Top Cabinet Finish: Galvanized Drain Pan Material Primary: Stainless Steel Filters Filter Rack Type: Standard 2 -inch 4 -Sided Filter Type: Disposable (Quantity) Filter Dimensions: (1) 29 In x 26 In x 2 In Insulation Compressor: Premium Compressor Compartment: 1/2 inch Fiberglass, Skin -faced Air Compartment: 3/4 inch Acoustic Open Cell Foam (Soundcoat) Piping: Insulated Piping Miscellaneous Sound Package: Premium Coil Treatment: None Unit warranty: 4 Yr Refrigerant Circuit Only Extended Parts Warranty, 1st Yr Labor Allowance All equipment is rated and certified in accordance with AHRI / ISO 13256-1 and tested, investigated, and determined to comply with the requirements of the standards for Heating and Cooling Equipment UL -1995 for the United States and CAN/CSA-C22.2 NO.236 for Canada. Optional Part Number Description 669481901 Hose, Kit, w/Ball Valves, Strainer, 0.75" x 2ft Job Number: LL20FE Page Job Name: Brackets Point House 13 of 26 Prepared Date: 8/30/2021 www.DaikinApplied.com Job Name Brackets Point House Date 8/30/2021 Submitted By Tim Harris Software Version 10.20 Unit Tag HP -020, HP -223, HP -add W GTV0381 208-230/60/1 1400 Model Number: WGTV038 Unit Type: SmartSource - 2 -Stage Approval: ETL, CETL, AHRI Configuration Refrigerant Type Vertical R -410A 9.00 38148 17.1" 28062 Refrigerant Weight Loop Temperature Range 77.0 oz Ground Loop (Geothermal) Air & Fluid Flow Airflow Total External Static Pressure Fluid Flow Fluid Type Glycol Concentration Altitude Full (Part) Full (Part) 0.30 (15txtSESPFull) 9.00 gpm / 3.00 1400(1250)CFM propylene Glycol 25.0% Oft inH20 gpm/ton Cooling Performance Fluid Temperature Air Temperature Capacity Heat of EER @ Fluid Entering Leaving Entering Leaving Total Sensible Rejection design Pressure 'F °F Dry Bulb Wet Bulb Dry Bulb Wet Bulb Btu/hr Btu/hr Drop Performance °F °F °F °F ft H20 Full Load 77.0 87.6 75.0 63.0 55.9 53.4 38148 29024 45740 17.1 10.43 Part Load 68.0 75.2 70.0 59.0 53.6 51.0 26865 22308 31236 21.0 10.62 Heating Performance Fluid Temperature Air Temperature Capacity Heat of COP @ design Fluid Pressure Entering Leaving Entering Leaving Total Absorption Drop °F °F Dry Bulb Dry Bulb Btu/hr Btu/hr ft H20 Performance °F °F Full Load 32.0 27.2 70.0 88.5 28062 20566 3.7 11.64 Part Load 41.0 36.9 70.0 87.0 23065 17538 4.2 11.34 *System WPD is calculated without the autoflow valve as the CV of an autoflow valve varies dependent on the system WPD. As long as the WPD is >3 psid, the autoflow valve will provide the selected GPM flowrate. Electrical Unit Voltage Minimum Voltage Total Unit Full Load Current Total Unit MCA 208-230/60/1 197 v 20.3 A 24.1 A Compressor RLA Compressor LRA Motor FLA Maximum Recommended Fuse Size / HACR Breaker Size 15.3A 83.0A 5.0A 35A *Short -Circuit Current = 5 kA rms symmetrical, 600 V maximum Job Number: LL20FE Job Name: Brackets Point House Page Prepared Date: 8/30/2021 14 of 26 www.DaikinApplied.com Unit Depth Height Width Weight Connection Shipping Operating Water Condensate 32.5 in 50.5 in 25.0 in 344 Ib 313 Ib 0.75 in 0.75 in Fan Motor Type Motor Horsepower ECM Constant CFM 0.50 hp Controls Unit Control: Microtech III Control Transformer: Standard 50 VA Transformer Thermostat/Sensor Control: Thermostat Control Unit Airflow Configuration Return Air Location: Right Hand Discharge Air Location: Top Cabinet Finish: Galvanized Drain Pan Material Primary: Stainless Steel Filters Filter Rack Type: Standard 2 -inch 4 -Sided Filter Type: Disposable (Quantity) Filter Dimensions: (1) 29 In x 26 In x 2 In Insulation Compressor: Premium Compressor Compartment: 1/2 inch Fiberglass, Skin -faced Air Compartment: 3/4 inch Acoustic Open Cell Foam (Soundcoat) Piping: Insulated Piping Miscellaneous Sound Package: Premium Coil Treatment: None Unit warranty: 4 Yr Refrigerant Circuit Only Extended Parts Warranty, 1st Yr Labor Allowance All equipment is rated and certified in accordance with AHRI / ISO 13256-1 and tested, investigated, and determined to comply with the requirements of the standards for Heating and Cooling Equipment UL -1995 for the United States and CAN/CSA-C22.2 NO.236 for Canada. Optional Part Number Description 669481901 Hose, Kit, w/Ball Valves, Strainer, 0.75" x 2ft Job Number: LL20FE Page Job Name: Brackets Point House 15 of 26 Prepared Date: 8/30/2021 www.DaikinApplied.com WGTV_38_LH-RH_Specs_Drawing for 3 Ton Vertical Certified Drawing WGTV 36 LH -RHI ED Spear. the VMWr Source Hest wnp product represented on th.a dixument will confoirn to the drawlttga and Group= WSHP 5pec4catbrta getout below_ nacmrdenee wdththe express, smlten Limited Warranty. Purchaaer'saccep- Type_ WGT11 Vertical lance of lhir.-drawing carter. that the conforming equipment meats the order meorfiratons. No cKwVes may be made to this uucument without the prior, express, written authorization of rho manufacturer. Date: October 2013 SmartSource" TWO Stage Vertical WSHP Model WG1V - Size 038 (Left-hand & right-hand ret -urn) Top Vi;rw - Leis Return L.dit Sms Ykw - Lift Kamm 7abio f . 0~0 cabrnot dimwmstans From F.o I A I Tap View- Rig ht ReWrn 1j Right Sitio- Wow - %ht Return Fre#5t 3AII Vires ,Right Hand ReSum Unil T FM AP 0 1 5' GTV-Wrtla:al UrilL 1.BY A=WFdIh U=OvRU► (17} 1936 the 32.50' 4826) 50.50' ti 283) gnage �pNng Ick 4) I I G +Frunr Vlex Um Vollepe Opeolnq iNete 0) GTV-Wrtla:al UrilL Ovararl I Cabins# Dinwnslens in Inches (mtn) A=WFdIh U=OvRU► G=Heiyht 1936 25.40' (635) 32.50' 4826) 50.50' ti 283) Nadas, AN dimensions within t 0-7D inrrhes f2-5 titan). Lernaf: CMPAP = Compmssor Corr-rynwi menf Access Parer C AP = Cordn:ii Access PansJ FU AP= Far? U"Acocss Parhof DAII % 20 13 DaikinAppied • w/wr.DakinARcorn • X800) 4s2-1342 V&VTV 3R LH-RH Spx 1 Page 1 of 3 Job Number: LL20FE Page Prepared Date: 8/30/2021 Job Name: Brackets Point House 11 of 25 www.DaikinApplied.com WGTV_38_LH-RH_Specs_Drawing for 3 Ton Vertical S ma rtS ou rce Im Two Stage Vert lcaI WSHP Model WrTV— Size 039 (Loft -hand A right-hand return) TabOs 2_ XpOrra & eiecrrtcal cnrrnectforrs WF"anmbns Naros: ° Supply and mrum Arid N comeXions = 314"(10 Feral) FPT a Law vcitage oflenrng = 718' (22 mm) dameter Line "age Opening = 7-W 0 mm) dMnieror. Cvndensar6 dram = 314` (79 mm) FPT Tsbfe 3_ Uischarloe duct mKar & return air mer upenincr dimensions oTv Plpinp Cannactlons In inchsm (nm} EleGulcel Connections In rrohas (mm� 3TV al Vertical 6 E F H J 14 L 439 supply Drtu ft&HWAlrr Desup-eehealtr Return eAbnd&ntLor Wattage' Between Line Voltage' V98ter supply Water keturn Drain X4, 086' 5.26 {83) 7.07 (1 RD) 1D.1171256) 1407 (357 17.S8 1,1154) 2.0 (72� 9.25 (233} 12.117 {367] Naros: ° Supply and mrum Arid N comeXions = 314"(10 Feral) FPT a Law vcitage oflenrng = 718' (22 mm) dameter Line "age Opening = 7-W 0 mm) dMnieror. Cvndensar6 dram = 314` (79 mm) FPT Tsbfe 3_ Uischarloe duct mKar & return air mer upenincr dimensions oTv Dlscharga Duct Collar Conne-ction In Inchea {mm) Return Alr Cal I Opening In Inches (enrol Vortical unit M N O P q R s r u 439 $44 {16,41 8.63 {245) 13.751348) 13.25 (337) 9.93 (ZI,$) 225 (571 Z7.W (6Rfi) 23.19 (5$7) 142 (41) NOW Aff" dimen=s ns ars referenced hen cutsade edge of nanny. Tabfe4 FNterrack assembly 4 miurn ith,duct cogardh"crtsfons Wet size 1f I w I x Y z M 24,57- M,11) I 27,3 096) 1 23 27 (7421 N.25 (667) 23.54 0971 2" Filwr Rack Optional 4" Fitwr Rack 2^{51i i+4'(102) ?C W I w x W 13 ry 36 r H-RH Spgeg J Pegs 7 0 7 Job Number: LL20FE Page Prepared Date: 8/30/2021 Job Name: Brackets Point House 12 of 25 www.DaikinApplied.com Job Name Brackets Point House Date 8/30/2021 Submitted By Tim Harris Software Version 10.20 Unit Tag HP -018B, HP -101A, HP -124 W GTV0491 208-230/60/1 1800 Model Number: WGTV049 Unit Type: SmartSource - 2 -Stage Approval: ETL, CETL, AHRI Configuration Refrigerant Type Vertical R -410A 12.00 47921 16,35651 Refrigerant Weight Loop Temperature Range 85.0 oz Ground Loop (Geothermal) Air & Fluid Flow Airflow Total External Static Pressure Fluid Flow Fluid Type Glycol Concentration Altitude Full (Part) Full (Part) 1800(1600)CFM 0.30 (15txtSESPFull) 12.00 gpm / 3.00 propylene Glycol 25.0% 0 ft inH20 gpm/ton Cooling Performance Fluid Temperature Air Temperature Capacity Heat of EER @ Fluid Entering Leaving Entering Leaving Total Sensible Rejection design Pressure 'F °F Dry Bulb Wet Bulb Dry Bulb Wet Bulb Btu/hr Btu/hr Drop Performance °F °F °F °F ft H20 Full Load 77.0 87.1 75.0 63.0 55.8 53.6 47921 37586 58036 16.2 7.11 Part Load 68.0 75.0 70.0 59.0 53.1 50.9 34737 29336 40580 20.3 7.24 Heating Performance Fluid Temperature Air Temperature Capacity Heat of COP @ design Fluid Pressure Entering Leaving Entering Leaving Total Absorption Drop °F °F Dry Bulb Dry Bulb Btu/hr Btu/hr ft Hzo Performance °F °F Full Load 32.0 27.6 70.0 88.2 35651 25660 3.6 7.93 Part Load 41.0 37.3 70.0 86.7 29070 21573 3.9 7.73 *System WPD is calculated without the autoflow valve as the CV of an autoflow valve varies dependent on the system WPD. As long as the WPD is >3 psid, the autoflow valve will provide the selected GPM flowrate. Electrical Unit Voltage Minimum Voltage Total Unit Full Load Current Total Unit MCA 208-230/60/1 197 v 28.5 A 33.8 A Compressor RLA Compressor LRA Motor FLA Maximum Recommended Fuse Size / HACR Breaker Size 21.2A 104.0A 7.3A 50A *Short -Circuit Current = 5 kA rms symmetrical, 600 V maximum Job Number: LL20FE Job Name: Brackets Point House Page Prepared Date: 8/30/2021 16 of 26 www.DaikinApplied.com Unit Depth Height Width Weight Connection Shipping Operating Water Condensate 32.5 in 54.5 in 25.0 in 384 Ib 352 Ib 1.00 in 0.75 in Fan Motor Type Motor Horsepower ECM Constant CFM 0.75 hp Controls Unit Control: Microtech III Control Transformer: Standard 50 VA Transformer Thermostat/Sensor Control: Thermostat Control Unit Airflow Configuration Return Air Location: Left Hand Discharge Air Location: Top Cabinet Finish: Galvanized Drain Pan Material Primary: Stainless Steel Filters Filter Rack Type: Standard 2 -inch 4 -Sided Filter Type: Disposable (Quantity) Filter Dimensions: (1) 29 In x 30 In x 2 In Insulation Compressor: Premium Compressor Compartment: 1/2 inch Fiberglass, Skin -faced Air Compartment: 3/4 inch Acoustic Open Cell Foam (Soundcoat) Piping: Insulated Piping Miscellaneous Sound Package: Premium Coil Treatment: None Unit warranty: 4 Yr Refrigerant Circuit Only Extended Parts Warranty, 1st Yr Labor Allowance All equipment is rated and certified in accordance with AHRI / ISO 13256-1 and tested, investigated, and determined to comply with the requirements of the standards for Heating and Cooling Equipment UL -1995 for the United States and CAN/CSA-C22.2 NO.236 for Canada. Optional Part Number Description 910182847 Hose, Kit Auto Flow, Strainer, Ball Vlv 1.0" x 3ft, 12.0 GPM Job Number: LL20FE Page Prepared Date: Job Name: Brackets Point House 17 of 26 8/30/2021 www.DaikinApplied.com Job Name Brackets Point House Date 8/30/2021 Submitted By Tim Harris Software Version 10.20 Unit Tag HP -018A - RH W GTV0491 208-230/60/1 1800 Model Number: WGTV049 Unit Type: SmartSource - 2 -Stage Approval: ETL, CETL, AHRI Configuration Refrigerant Type Vertical R -410A 12.00 47921 16,35651 Refrigerant Weight Loop Temperature Range 85.0 oz Ground Loop (Geothermal) Air & Fluid Flow Airflow Total External Static Pressure Fluid Flow Fluid Type Glycol Concentration Altitude Full (Part) Full (Part) 1800(1600)CFM 0.30 (15txtSESPFull) 12.00 gpm / 3.00 propylene Glycol 25.0% 0 ft inH20 gpm/ton Cooling Performance Fluid Temperature Air Temperature Capacity Heat of EER @ Fluid Entering Leaving Entering Leaving Total Sensible Rejection design Pressure 'F °F Dry Bulb Wet Bulb Dry Bulb Wet Bulb Btu/hr Btu/hr Drop Performance °F °F °F °F ft H20 Full Load 77.0 87.1 75.0 63.0 55.8 53.6 47921 37586 58036 16.2 7.11 Part Load 68.0 75.0 70.0 59.0 53.1 50.9 34737 29336 40580 20.3 7.24 Heating Performance Fluid Temperature Air Temperature Capacity Heat of COP @ design Fluid Pressure Entering Leaving Entering Leaving Total Absorption Drop °F °F Dry Bulb Dry Bulb Btu/hr Btu/hr ft Hzo Performance °F °F Full Load 32.0 27.6 70.0 88.2 35651 25660 3.6 7.93 Part Load 41.0 37.3 70.0 86.7 29070 21573 3.9 7.73 *System WPD is calculated without the autoflow valve as the CV of an autoflow valve varies dependent on the system WPD. As long as the WPD is >3 psid, the autoflow valve will provide the selected GPM flowrate. Electrical Unit Voltage Minimum Voltage Total Unit Full Load Current Total Unit MCA 208-230/60/1 197 v 28.5 A 33.8 A Compressor RLA Compressor LRA Motor FLA Maximum Recommended Fuse Size / HACR Breaker Size 21.2A 104.0A 7.3A 50A *Short -Circuit Current = 5 kA rms symmetrical, 600 V maximum Job Number: LL20FE Job Name: Brackets Point House Page Prepared Date: 8/30/2021 18 of 26 www.DaikinApplied.com Unit Depth Height Width Weight Connection Shipping Operating Water Condensate 32.5 in 54.5 in 25.0 in 384 Ib 352 Ib 1.00 in 0.75 in Fan Motor Type Motor Horsepower ECM Constant CFM 0.75 hp Controls Unit Control: Microtech III Control Transformer: Standard 50 VA Transformer Thermostat/Sensor Control: Thermostat Control Unit Airflow Configuration Return Air Location: Right Hand Discharge Air Location: Top Cabinet Finish: Galvanized Drain Pan Material Primary: Stainless Steel Filters Filter Rack Type: Standard 2 -inch 4 -Sided Filter Type: Disposable (Quantity) Filter Dimensions: (1) 29 In x 30 In x 2 In Insulation Compressor: Premium Compressor Compartment: 1/2 inch Fiberglass, Skin -faced Air Compartment: 3/4 inch Acoustic Open Cell Foam (Soundcoat) Piping: Insulated Piping Miscellaneous Sound Package: Premium Coil Treatment: None Unit warranty: 4 Yr Refrigerant Circuit Only Extended Parts Warranty, 1st Yr Labor Allowance All equipment is rated and certified in accordance with AHRI / ISO 13256-1 and tested, investigated, and determined to comply with the requirements of the standards for Heating and Cooling Equipment UL -1995 for the United States and CAN/CSA-C22.2 NO.236 for Canada. Optional Part Number Description 910182847 Hose, Kit Auto Flow, Strainer, Ball Vlv 1.0" x 3ft, 12.0 GPM Job Number: LL20FE Page Prepared Date: Job Name: Brackets Point House 19 of 26 8/30/2021 www.DaikinApplied.com Job Name Brackets Point House Date 8/30/2021 Submitted By Tim Harris Software Version 10.20 Unit Tag HP -026 - RH W GTV0491 208-230/60/1 1800 Model Number: WGTV049 Unit Type: SmartSource - 2 -Stage Approval: ETL, CETL, AHRI Configuration Refrigerant Type Vertical R -410A 12.00 47921 16,35651 Refrigerant Weight Loop Temperature Range 85.0 oz Ground Loop (Geothermal) Air & Fluid Flow Airflow Total External Static Pressure Fluid Flow Fluid Type Glycol Concentration Altitude Full (Part) Full (Part) 1800(1600)CFM 0.30 (15txtSESPFull) 12.00 gpm / 3.00 propylene Glycol 25.0% 0 ft inH20 gpm/ton Cooling Performance Fluid Temperature Air Temperature Capacity Heat of EER @ Fluid Entering Leaving Entering Leaving Total Sensible Rejection design Pressure 'F °F Dry Bulb Wet Bulb Dry Bulb Wet Bulb Btu/hr Btu/hr Drop Performance °F °F °F °F ft H20 Full Load 77.0 87.1 75.0 63.0 55.8 53.6 47921 37586 58036 16.2 7.11 Part Load 68.0 75.0 70.0 59.0 53.1 50.9 34737 29336 40580 20.3 7.24 Heating Performance Fluid Temperature Air Temperature Capacity Heat of COP @ design Fluid Pressure Entering Leaving Entering Leaving Total Absorption Drop °F °F Dry Bulb Dry Bulb Btu/hr Btu/hr ft Hzo Performance °F °F Full Load 32.0 27.6 70.0 88.2 35651 25660 3.6 7.93 Part Load 41.0 37.3 70.0 86.7 29070 21573 3.9 7.73 *System WPD is calculated without the autoflow valve as the CV of an autoflow valve varies dependent on the system WPD. As long as the WPD is >3 psid, the autoflow valve will provide the selected GPM flowrate. Electrical Unit Voltage Minimum Voltage Total Unit Full Load Current Total Unit MCA 208-230/60/1 197 v 28.5 A 33.8 A Compressor RLA Compressor LRA Motor FLA Maximum Recommended Fuse Size / HACR Breaker Size 21.2A 104.0A 7.3A 50A *Short -Circuit Current = 5 kA rms symmetrical, 600 V maximum Job Number: LL20FE Job Name: Brackets Point House Page Prepared Date: 8/30/2021 20 of 26 www.DaikinApplied.com Unit Depth Height Width Weight Connection Shipping Operating Water Condensate 32.5 in 54.5 in 25.0 in 384 Ib 352 Ib 1.00 in 0.75 in Fan Motor Type Motor Horsepower ECM Constant CFM 0.75 hp Controls Unit Control: Microtech III Control Transformer: Standard 50 VA Transformer Thermostat/Sensor Control: Thermostat Control Unit Airflow Configuration Return Air Location: Right Hand Discharge Air Location: Top Cabinet Finish: Powder Coat Color: Charcoal Bronze Drain Pan Material Primary: Stainless Steel Filters Filter Rack Type: Standard 2 -inch 4 -Sided Filter Type: Disposable (Quantity) Filter Dimensions: (1) 29 In x 30 In x 2 In Insulation Compressor: Premium Compressor Compartment: 1/2 Inch Fiberglass, Skin -faced Air compartment: 3/4 inch Acoustic Open Cell Foam (Soundcoat) Piping: Insulated Piping Miscellaneous Sound Package: Premium Coil Treatment: Corrosion Protection Unit warranty: 4 Yr Refrigerant Circuit Only Extended Parts Warranty, 1st Yr Labor Allowance All equipment is rated and certified in accordance with AHRI / ISO 13256-1 and tested, investigated, and determined to comply with the requirements of the standards for Heating and Cooling Equipment UL -1995 for the United States and CAN/CSA-C22.2 NO.236 for Canada. Optional Part Number Description 910182847 Hose, Kit Auto Flow, Strainer, Ball Vlv 1.0" x 3ft, 12.0 GPM Job Number: LL20FE Page Prepared Date: Job Name: Brackets Point House 21 of 26 8/30/2021 www.DaikinApplied.com WGTV_44-49_LH-RH_Specs_Drawing for 4 Ton Vertical - LH Certified Drawing WGTV44-0 LH-RH $pace the VMWr Source Hest Fvnp product represented on th.a dixument will confoirn to the drawlttga erre Group= WSHIP 5pec4catbrta getout below- nacmrdenee wdththe express, smlten Llmlted Warranty. Purchaaer'saccep- Type_ WGT11 Vertical lance of lhie-drawing cartes that the conforming equipment meats the order meorfiratons. No cKwVes may be made to chis document without the prior, express, written author¢auan of rho manufacturer. Date: October 2013 SmartSource" TWO Stage Vertical W HP Model WG1V - Size 044 & 049 (Left-hand & right-hand retum) Top Vi;rw - Leis 11wWrn L.rft SWE Ykw - Liit @atom Tabid f . 0~0 cabkiet dlmwrstans From F.o I A I Tap View- Rig ht ReWrn t Right SWe Wow - %ht Return Fre#5t 3AII Vires , Righl Hand ReSum Unil T FM AP U 13' GTV-Wrtla:al UrilL 1.69' A=WFdIh U=OvRU► f17} OMS 0411 the 32.50' 4826j 54.50' {138 j anaQe �pNng Ick 4) I I G +Frunr Vlex Um Vollepe Opeoln4 iNete 3} GTV-Wrtla:al UrilL Ovararl I Cabins# Dinwnslens in Inches (mtn) A=WFdIh U=OvRU► G=Heiyht OMS 0411 25.40' (635) 32.50' 4826j 54.50' {138 j Nadas, AN dimensions within t 0-10 inures f2-5 imm). Lernaf: CMPAP = Compmssor Conry rfrrmonf Access Parer C AP = Caardn3Access PansJ FU AP= Far? M"Acccss Parhof DAII % 20 1 S Daikin Appied • vimAw.aak nARcorn • X800) 4s2-1342 Vr6TV 41-49 LH-RH Spn s f Pegs 1 012 Job Number: LL20FE Page Prepared Date: 8/30/2021 Job Name: Brackets Point House 15 of 25 www.DaikinApplied.com WGTV_44-49_LH-RH_Specs_Drawing for 4 Ton Vertical SmartSource'M Two Stage Vertical WSHP Model WGTV— Siz-a 044 & 045 (Left-hand & right-hand return TabOs 2_ XpOnQ & efectrtcat connecrfons dfinensiona Nares: ' Supply and mrum Arpirrg caruneorions = f"(26 mrro €Pf Law vcftage oflenrng = 718' (22mm)cffameter Line "age Opening = 7• W (29 mm) dMnieror. Cvndenssfe dram = 314'(19 mm) FPT Tsbfe 3_ Uischame duct mKar & return air coir upenina dimensions GTv Plpinp Cannaotlans In inchsm (mm} EleGulcel Connections In aches fmm� 3TV Vertical 6 E F H J K L 11n1t supply Drtu ft&HWAlrr Desup.eehealtr Return t:bnd6nsaiw Lour Yaltage' Between Line Voltage' YNeter supply Water keturn Drain 3P1" 644, OW 3.117 [M) 7.07 (19D) 1D.1171256) 1388 (553 17.8911164) 2.0 (72� 9.25 (233} 12.117 {367] Nares: ' Supply and mrum Arpirrg caruneorions = f"(26 mrro €Pf Law vcftage oflenrng = 718' (22mm)cffameter Line "age Opening = 7• W (29 mm) dMnieror. Cvndenssfe dram = 314'(19 mm) FPT Tsbfe 3_ Uischame duct mKar & return air coir upenina dimensions GTv Dlscharga Duct Collar Conne-ction In Inchea {mm) Return Alr Cal I Opening In Inches (enrol Vortical Unit M N O P q R s r u OK C49 544 {16,41 8.63 {2115] 13.751349) 13.25 (337) 9.93 (ZI,$) 225 (571 Z7.pp (6Rfi) 27.19 (6.98) 142 (41) SM. Aff" dimen=s ns ars referenced hover cursade edge of Nange, Tabfa4; Fflrerrack assembly 4 return alfrducr coiYardh"ertsfons un it sire V I W X Y z 944, 049 2$.57.1726] I 27,3Er 096) 1 2322' (7421 34,25 (769) 23.54 0971 2- Mar Rack T7 4pllonal 4- RItNF Rack ---i hr 4-(102) W x WGTV 4449 LH-Rli Specs! Page 2 of 2 Job Number: LL20FE Page Prepared Date: 8/30/2021 Job Name: Brackets Point House 16 of 25 www.DaikinApplied.com Job Name Brackets Point House Date 8/30/2021 Submitted By Tim Harris Software Version 10.20 Unit Tag HP -033 - LH W GTV0641 208-230/60/1 2250 Model Number: WGTV064 Unit Type: SmartSource - 2 -Stage Approval: ETL, CETL, AHRI Configuration Refrigerant Type Vertical R -410A 15.00 62248 16.1 Refrigerant Weight 120.0 oz 45272 3.5 Loop Temperature Range Ground Loop (Geothermal) Air & Fluid Flow Airflow Total External Static Pressure Fluid Flow Fluid Type Glycol Concentration Altitude Full (Part) Full (Part) 0.30 (15txtSESPFull) 15.00 gpm / 3.00 2250(2000)CFM propylene Glycol 25.0% 0 ft inH20 gpm/ton Cooling Performance Fluid Temperature Air Temperature Capacity Heat of EER @ Fluid Entering Leaving Entering Leaving Total Sensible Rejection design Pressure 'F °F Dry Bulb Wet Bulb Dry Bulb Wet Bulb Btu/hr Btu/hr Drop Performance °F °F °F °F ft H20 Full Load 77.0 87.5 75.0 63.0 55.3 53.2 62248 48050 75463 16.1 11.46 Part Load 68.0 75.3 70.0 59.0 52.2 50.6 44794 38591 52502 19.8 11.67 Heating Performance Fluid Temperature Air Temperature Capacity Heat of COP @ design Fluid Pressure Entering Leaving Entering Leaving Total Absorption Drop °F °F Dry Bulb Dry Bulb Btu/hr Btu/hr ft Hzo Performance °F °F Full Load 31.0 26.5 70.0 88.5 45272 32328 3.5 12.83 Part Load 41.0 37.1 70.0 87.5 37925 28035 3.8 12.46 *System WPD is calculated without the autoflow valve as the CV of an autoflow valve varies dependent on the system WPD. As long as the WPD is >3 psid, the autoflow valve will provide the selected GPM flowrate. Electrical Unit Voltage Minimum Voltage Total Unit Full Load Current Total Unit MCA 208-230/60/1 197 v 36.5 A 43.3 A Compressor RLA Compressor LRA Motor FLA Maximum Recommended Fuse Size / HACR Breaker Size 27.1A 152.9A 9.4A 60A *Short -Circuit Current = 5 kA rms symmetrical, 600 V maximum Job Number: LL20FE Page Prepared Date: 8/30/2021 Job Name: Brackets Point House 22 of 26 www.DaikinApplied.com Unit Depth Height Width Weight Connection Shipping Operating Water Condensate 32.5 in 58.5 in 25.0 in 496 Ib 470 Ib 1.00 in 0.75 in Fan Motor Type Motor Horsepower ECM Constant CFM 1.00 hp Controls Unit Control: Microtech III Control Transformer: Standard 50 VA Transformer Thermostat/Sensor Control: Thermostat Control Unit Airflow Configuration Return Air Location: Left Hand Discharge Air Location: Top Cabinet Finish: Galvanized Drain Pan Material Primary: Stainless Steel Filters Filter Rack Type: Standard 2 -inch 4 -Sided Filter Type: Disposable (Quantity) Filter Dimensions: (1) 34 In x 29 In x 2 In Insulation Compressor: Premium Compressor Compartment: 1/2 inch Fiberglass, Skin -faced Air Compartment: 3/4 inch Acoustic Open Cell Foam (Soundcoat) Piping: Insulated Piping Miscellaneous Sound Package: Premium Coil Treatment: None Unit warranty: 4 Yr Refrigerant Circuit Only Extended Parts Warranty, 1st Yr Labor Allowance All equipment is rated and certified in accordance with AHRI / ISO 13256-1 and tested, investigated, and determined to comply with the requirements of the standards for Heating and Cooling Equipment UL -1995 for the United States and CAN/CSA-C22.2 NO.236 for Canada. Optional Part Number Description 669482001 Hose, Kit, w/Ball Valves, Strainer, 1.00" x 2ft Job Number: LL20FE Page Job Name: Brackets Point House 23 of 26 Prepared Date: 8/30/2021 www.DaikinApplied.com Job Name Brackets Point House Date 8/30/2021 Submitted By Tim Harris Software Version 10.20 Unit Tag HP -101B - RH W GTV0641 208-230/60/1 2250 Model Number: WGTV064 Unit Type: SmartSource - 2 -Stage Approval: ETL, CETL, AHRI Configuration Refrigerant Type Vertical R -410A 15.00 62248 161.� Refrigerant Weight Loop Temperature Range 120.0 oz Ground Loop (Geothermal) Air & Fluid Flow Airflow Total External Static Pressure Fluid Flow Fluid Type Glycol Concentration Altitude Full (Part) Full (Part) 0.30 (15txtSESPFull) 15.00 gpm / 3.00 2250(2000)CFM propylene Glycol 25.0% 0 ft inH20 gpm/ton Cooling Performance Fluid Temperature Air Temperature Capacity Heat of EER @ Fluid Entering Leaving Entering Leaving Total Sensible Rejection design Pressure 'F °F Dry Bulb Wet Bulb Dry Bulb Wet Bulb Btu/hr Btu/hr Drop Performance °F °F °F °F ft H20 Full Load 77.0 87.5 75.0 63.0 55.3 53.2 62248 48050 75463 16.1 11.46 Part Load 68.0 75.3 70.0 59.0 52.2 50.6 44794 38591 52502 19.8 11.67 Heating Performance Fluid Temperature Air Temperature Capacity Heat of COP @ design Fluid Pressure Entering Leaving Entering Leaving Total Absorption Drop °F °F Dry Bulb Dry Bulb Btu/hr Btu/hr ft Hzo Performance °F °F Full Load 31.0 26.5 70.0 88.5 45272 32328 3.5 12.83 Part Load 41.0 37.1 70.0 87.5 37925 28035 3.8 12.46 *System WPD is calculated without the autoflow valve as the CV of an autoflow valve varies dependent on the system WPD. As long as the WPD is >3 psid, the autoflow valve will provide the selected GPM flowrate. Electrical Unit Voltage Minimum Voltage Total Unit Full Load Current Total Unit MCA 208-230/60/1 197 v 36.5 A 43.3 A Compressor RLA Compressor LRA Motor FLA Maximum Recommended Fuse Size / HACR Breaker Size 27.1A 152.9A 9.4A 60A *Short -Circuit Current = 5 kA rms symmetrical, 600 V maximum Job Number: LL20FE Job Name: Brackets Point House Page Prepared Date: 8/30/2021 24 of 26 www.DaikinApplied.com Unit Depth Height Width Weight Connection Shipping Operating Water Condensate 32.5 in 58.5 in 25.0 in 496 Ib 470 Ib 1.00 in 0.75 in Fan Motor Type Motor Horsepower ECM Constant CFM 1.00 hp Controls Unit Control: Microtech III Control Transformer: Standard 50 VA Transformer Thermostat/Sensor Control: Thermostat Control Unit Airflow Configuration Return Air Location: Right Hand Discharge Air Location: Top Cabinet Finish: Galvanized Drain Pan Material Primary: Stainless Steel Filters Filter Rack Type: Standard 2 -inch 4 -Sided Filter Type: Disposable (Quantity) Filter Dimensions: (1) 34 In x 29 In x 2 In Insulation Compressor: Premium Compressor Compartment: 1/2 inch Fiberglass, Skin -faced Air Compartment: 3/4 inch Acoustic Open Cell Foam (Soundcoat) Piping: Insulated Piping Miscellaneous Sound Package: Premium Coil Treatment: None Unit warranty: 4 Yr Refrigerant Circuit Only Extended Parts Warranty, 1st Yr Labor Allowance All equipment is rated and certified in accordance with AHRI / ISO 13256-1 and tested, investigated, and determined to comply with the requirements of the standards for Heating and Cooling Equipment UL -1995 for the United States and CAN/CSA-C22.2 NO.236 for Canada. Optional Part Number Description 669482001 Hose, Kit, w/Ball Valves, Strainer, 1.00" x 2ft Job Number: LL20FE Page Job Name: Brackets Point House 25 of 26 Prepared Date: 8/30/2021 www.DaikinApplied.com WGTV_64-72_LH-RH_Specs_Drawing for HP -033 Certified Drawing WGTY 64-72 LH-RH Spres the VNrtar Source Hest 19rnp product represented on th.a tloeument will confoirn to the drawltrga erre Group= WSHIP 5pec4cationa getout hetau_ nacmrdenee wdththe express, Lmlten Llmlted Warranty. Purchaaer'saccep- Type_ WGT11 Vertical lance of lhie-drawing cartrfiee that the wnfanning equipment meats the order waorfiratons. No cKwVes may be made to iihis uucumeat without the prior, express, written authorization of rho manufacturer. Date: October 2013 SmartSource" TWO Stage Vertical W HP Model WG1V - Size 064 & 072 (Left-hand & right-hand retum) Top Vi;eH - Leis P.iurn Lok Swe V luw - Loir kalium 7abio f . 0~0 cabkiet dFlnwrstans Fra O A C,gil Tap view - Fright PmWin I Right Side V -row - RLeht Retorrh GTV-Wrtla:al LIWL Ovararl I Cabins# Dinwnslens in Inches. (mtn) FMAP B=OvRU► G=Heiyht D 25.40- (635) 1.6r 56.50- ti 486) (47) Lha ' 1�tlege Neo �Wok4) FT. I CAP L I D From Wiex LO Uu11u9u Opening {Nate 0) GTV-Wrtla:al LIWL Ovararl I Cabins# Dinwnslens in Inches. (mtn) A=WFdIh B=OvRU► G=Heiyht 0(A, 072 25.40- (635) 32.50' 4826) 56.50- ti 486) Noda6. AN dimensions within t 0.70 fnrhes f2.5 imm). Lernaf: CMPAP = Compmssor Corr-rynwi menf Access Parer C AP = Caardn3Access PansJ FM AP = Fars Jrti"Acocss Parhof DAII % 20 1 S Daikin Appied - w/wr.DakinARcorn - X800) 4s2-1342 Vow - Right Rued Rehm Unit 1 $- WGTV e4-72 LH -RM $pax I puge 1 012 Job Number: LL20FE Page Prepared Date: 8/30/2021 Job Name: Brackets Point House 23 of 25 www.DaikinApplied.com WGTV_64-72_LH-RH_Specs_Drawing for HP -033 M0 -del WGTV— Sizo D64& 072 �LL%k-hand & right-hand returin) Tabla 2. Pipin4 & electrical cnrrnectians dimenslarm Hones:Supply acrd rerurn pprrg wm4?c nos = f"(25 mFrr) FPT. 1 Low voltage opening = 718" (22mm)Clamelar Lae vaJia�e oioen�rrg - 7.4J&` X29 rnm) d+ar�rerer. Condenaale drain = 3f4` {79 mm) FFT. Tabie 3r Discharge duct eflrle,r A return ser coir opening dimerHm3%r e GT++ Plpinp Camaatlone In inches (mm) Eleculcal Connections In inehee (mm) GTV Yertkial d E F {l H J K L dolt Supple Desuperhaaler DasupErheater Rewrn Candensake Levy Voltage° Between Line Voltage' Water Supply Water Retur 5 Drain 3!4" 444, 972T 3.47 ice) 7.07 (190) 1 p.971256] i 11 M (3531 1 17.881454) 2.42 (72i 9..25 (235} 1 12.97 (347) Hones:Supply acrd rerurn pprrg wm4?c nos = f"(25 mFrr) FPT. 1 Low voltage opening = 718" (22mm)Clamelar Lae vaJia�e oioen�rrg - 7.4J&` X29 rnm) d+ar�rerer. Condenaale drain = 3f4` {79 mm) FFT. Tabie 3r Discharge duct eflrle,r A return ser coir opening dimerHm3%r e GT++ 014chaega Duel Callan Cenne.cman Irk inches {nlm) RaWrkAk CnY 4WIN M Indira lmrel Vertical Unit M N O P Q R S T u p64 072 6.44 (1 64) 9.69 P-45) 13.751949) 1 19.25 (3W7 9.113 (245} 2 25 (57i 27.0Q (696) 97.19 l ) 1.62 (41) More, AN dtv doaensrons area referenced f m The outside nage of The dango. Table 4: Fater rack a:r#embly 4 return s;r duct calcar dJmensions UFO See V W x Y z 064. M 92,57'(827) 21.36'16961 29 2Y (742) 34,25 (970) 29.50 (597) 2" FiRvrRa,k Optional 4" Filter Rack �{ 2' 151) 1,4-(1020 x I Lu j r WGTVdL•72 U4rRFI Specs i Page 2 or 2 Job Number: LL20FE Page Prepared Date: 8/30/2021 Job Name: Brackets Point House 24 of 25 www.DaikinApplied.com Specification for WSHP SmartSource ALL PART 1: PRODUCTS 1.01 General: A. Electrical —All heat pump nameplate electrical utilization voltages shall be in conformance with ANSI Standard C84.1 as follows: B. All Water Source Heat Pump units shall be suitable for continuous operation with a supply voltage variation, measured at the factory power connection point, of ± 10% of the nameplate voltage. A control box shall be located within the unit and shall contain controls for compressor, reversing valve, and fan motor operation and shall have a 50VA 24V control circuit transformer and a terminal block for low voltage field wiring connections. Unit shall be nameplated to accept time delay fuses or HACR circuit breaker for branch overcurrent protection of the power source. All units shall have a Short -Circuit current rating of 5kA rms symmetrical, 600V maximum. C. Ceiling Mounted Units — Each heat pump shall incorporate four independent access panels to facilitate service to internal components from front or backside. Unit shall have an insulated divider panel between compressor compartment and fan blower section. Access panels shall be designed to cover an individual unit section, such as the fan blower, while servicing compressor compartment and related refrigerant components. D. Floor Mounted Units — Each heat pump shall incorporate four independent access panels to facilitate service to internal components from front or backside. Unit shall have an insulated divider panel between compressor compartment and fan blower section. Access panels shall be designed to cover an individual unit section, such as the fan blower, while servicing compressor compartment and related refrigerant components. E. Configuration — Units shall be provided configured as shown on the plans, in one of the following air -flow arrangements (Note: "Right" or "Left" side shall be determined when viewing the compressor compartment end panel): 1. Right Hand Return Air and Right Hand Piping Connections F. Fan and Motor Assembly — An ECM blower motor shall be provided on all units. Units shall have a direct drive centrifugal fan. Factory motor wiring shall be set for optimum fan performance. CFM settings shall be field adjustable by means of a fan speed selector switch located in the unit control box. The unit shall be shipped at one fixed setting. The ECM motor shall utilize a permanent magnet rotor, which is connected to the shaft through resilient rings to absorb high frequency torque ripple. The ECM motor shall deliver precise speed and economical performance regardless of system static pressure. Independent CFM adjustment for mode specific operation. G. Blower - The blower housing shall have a removable orifice ring to facilitate blower wheel and motor removal for ease of service and without the need to disconnect ductwork. Units without a removable orifice ring are not acceptable. H. Refrigerant Circuit — A sealed refrigerant circuit, consisting of a high efficiency scroll, rotary or reciprocating hermetic motor -compressor mounted on rubber vibration isolation grommets (spring isolators shall not be accepted), air-to-air refrigerant finned tube coil, refrigerant flow metering device, water -to -refrigerant coaxial tube type heat exchanger, high pressure safety cutout, and fusible pressure relief factory -installed on the refrigerant circuit. Heat pump conditioners shall additionally contain a pilot -operated refrigerant reversing valve. The reversing valve shall be energized for heating operation. High and low side refrigerant service valves shall be provided. The refrigerant flow -metering device shall be a thermostatic expansion valve. Refrigerant will be HFC R410A in all sizes. I. Safety Controls — High and low pressure switches and low temperature safety sensors shall be wired through a latching lockout circuit to disable the unit until it is reset electrically by interrupting the power supply to the unit. Automatic reset by wall sensor switching shall not be allowed. All safety switches shall be normally closed, opening upon fault detection. Control logic dependent upon the closing of a normally open switch shall not be allowed to preclude the possibility of simple, easily corrected faults being escalated into compressor or heat exchanger failure due to loss of integrity in control wiring. (heating or cooling methods that do not require the refrigeration circuit, including hydronic heat, waterside economizer, and electric heat, shall be allowed to operate during lockout. This includes fan and pump operation) Job Number: LL2OFE Page Prepared Date: 10/8/2020 Job Name: Brackets Point House 30 of 35 www.DaikinApplied.com Specification for WSHP SmartSource ALL J. Geothermal (extended range) Operation — Manufacturer shall guarantee "extended range" heat pump units to start and operate continuously in an ambient of 40° F, with entering air and water at 40° F, with both air and water at the flow rates used in the ARI/ISO rating test. A geothermal extended range option shall be made up of a TXV metering device and wrapped condenser coil. Closed cell insulation shall be added to the internal water lines and on suction side refrigerant tubing including refrigerant to water heat exchanger. K. Air Section - The air section of the unit shall be isolated from the compressor and control section with an insulated divider panel to minimize the transmission of compressor noise and to permit operational service testing with the compressor compartment cover removed. L. Filter and Filter Racks — All units shall be provided with a 2" thick, disposable type fiberglass filter installed in a factory mounted four-sided 2" filter frame arranged for side removal. M. Supply and return, condenser water connections — shall be FPT fittings, brazed copper water tubes and securely flush mounted to the cabinet corner post allowing for connection to a flexible hose without the use of a back-up wrench. Condensate drain connection shall not be less than %" FPT fitting securely flush mounted to the corner post. Supply, return, and condensate drain shall be connected to loop and drain piping as detail on mechanical drawings. Piping connections at the unit which require brazing or soldering by the installer (which may damage the unit) shall not be allowed. N. Stainless Steel Drain Pan — Unit shall utilize corrosion resistant closed -cell insulated stainless steel drain pans. A stub out connection shall be provided. The drain pan shall be designed to ensure no pooling of condensate water per ASHRAE 62.2. The unit will be supplied with solid-state electronic condensate overflow protection as standard. Mechanical float switches will not be accepted. 0. Sound Package — Available as a factory installed option, units shall utilize sound attenuating compressor blankets with high technology sound attenuating material that is strategically applied within the air handling compartment casings to further reduce sound transmitted by the unit while in operation. P. Coaxial Coil Supply Liquid Auto Flow Regulator - This factory -installed option includes the addition of an automatic flow control valve to set and limit the GPM through the unit. The valve shall have a "replaceable cartridge" capability. The valve shall be rated for 600 psig. (Note: This option will not be available with Internal Water Pump option.). Q. Control System (Microtech III Unit Controller) - 1. The unit control board shall be the main component of the system and shall contain the required inputs/outputs to operate a water source heat pump with a single speed fan. 2. Unit controller inputs/outputs: The Microtech III controller will be microprocessor -based and have capabilities, performance, and memory sufficient to execute the various functions detailed in this specification. This document will not specify a type, a manufacturer, or a family of microcontrollers to be considered for use. However, at a minimum, the following features are deemed essential: a. Analog Inputs: (Condensate Overflow, Brownout Detection, Suction -Line Temp Sensor, Timed Override Switch, Set point Adjust, Fan Mode — (Heat/Cool/Auto) b. Condensate Overflow. The presence of excessive condensate in the condensate drain pan is detected by a condensate sensor, which consists of a metal terminal ring mounted just below the top of the condensate pan. The analog input dedicated to condensate sensing must be capable of detecting the conductivity of water between the ring terminal and chassis ground. The conductivity trip point is 2.5 micro-ohms. c. Brownout Detection. This analog input will measure the 24VAC input voltage applied to the controller as a means of indirectly monitoring line voltage applied to the unit. The 24VAC input, once rectified, filtered, and fed to an appropriate voltage divider, will be applied to the analog input as a DC voltage level proportional to the input voltage. At a minimum, the measurable range will be between 70 and 120% of the corresponding unit nameplate voltage. Due to the tolerances involved with the various components associated with this approach, calibration will occur during factory test when exactly 100% nameplate voltage is applied to the unit while in cooling mode. The digitized value of the resultant DC voltage applied to the analog input during the calibration period will be saved within the controller (in non-volatile memory) and used as a reference Job Number: LL2OFE Page Prepared Date: 10/8/2020 Job Name: Brackets Point House 31 of 35 www.DaikinApplied.com Specification for WSHP SmartSource ALL value for subsequent operation in the field. The brownout trip and recovery levels are a function of the application software and are listed elsewhere in this specification. d. Suction -Line Temp Sensor. Sensing element shall be equivalent to NTC Thermistor —10K ohms @ 25°C, 0.2°C interchangeability. Advanced Thermal Products — Curve Z. NOTE: The Timed (Tenant) Override switch will short out the Room sensor thermistor. Sensing range shall be 0 to 1587 with a resolution of 1°F and an accuracy of +/- 1.57 Maximum Total Error. e. Set point Adjust. The Set point Adjust circuit of a remote room sensor shall consist of a 1.5K -ohm 2 -wire potentiometer. The wiper of the potentiometer will be connected to the analog input. The other lead of the potentiometer is tied to analog common. The 0 —1.5K -ohm range will be interpreted by the base controller as an offset to the current temperature Set point -5 to +5 degrees F or a range of 55 to 95 degrees F (jumper selectable and scaled accordingly in software). f. Fan On/Auto, Heat/Cool/Auto The Room Sensor shall incorporate switches and fixed resistors that present different resistance values to a single analog input which correspond to the fan and operating mode functions detailed below. The room sensor is designed with specific resistance values to coincide with the software in unit control module. g. Temperature Input. Sensing element in the Microtechlll room temperature sensor is equivalent to NTC Thermistor —10K ohms @ 25°C, 0.2°C interchangeability. Advanced Thermal Products — Curve Z. NOTE: The Timed (Tenant) Override switch will short out the Room sensor thermistor. Sensing range shall be 0 to 158°F with a resolution of 1°F and an accuracy of +/- 1.5°F Maximum Total Error. h. Binary Inputs. 18 total (Low Pressure, High Pressure, Emergency Shutdown, 8 -Board level jumpers, 6 thermostat, Occupied/Unoccupied) that employ the Occupied/Unoccupied control. i. The Low Pressure switch shall be sourced with 24VAC or DC, +/-20%. The binary input detection circuit shall be designed such that a minimum of 7mA current flows through the external contacts. J. The High Pressure switch shall be part of an interlock circuit that interrupts power to the on -board compressor relay coil. Since this is a low voltage safety circuit as defined by UL, the designer must apply appropriate spacing as dictated by the relevant UL standards. As part of HP switch state detection, this circuit must sense the current flowing through the on -board compressor relay coil and communicate this information to the HP binary input. The current sensing circuit (Example device: NEC/CEL PS2501-1-A opto- isolator) must be upstream of the High Pressure switch, i.e., between the control output and the HP switch. In the unlikely event that the compressor binary output or HP current sensing circuit fails closed, the HP switch can still perform its intended safety function by opening the compressor relay coil circuit. k. Emergency Shutdown. This binary input will detect the presence of an earth grounded signal, which is supplied by an external, remote set of contacts — such as those provided by a Condenser Loop Water Controller. I. Unoccupied Mode. This binary input will detect the presence of an earth grounded signal, which is supplied by an external, remote set of contacts — such as those provided by a Condenser Loop Water Controller. m. Thermostat inputs G, Y1, Y2, W1, W2, shall detect the presence of 24VAC sourced from the "R" terminal. The binary input conditioning circuitry for these inputs is designed to be compatible with conventional wall thermostats. n. Board Level Jumpers: JP1 Senice.Test Mode JP2 Continuous:'cyding fan JP3 Water:'G1yco1 (Loop tluid) JP4 Freeze fault protection JP5 Room Temperature Set point adjustment range JP6 Local control type (thermostat or room sensor) JP: Primary heating source (compressor or other) ]P8 L'4 expansion module (present or not required) 3. Binary Outputs: 9 total (Main Fan, Compressor, Reversing Valve, Isolation valve/Pump Request, 3 Board Status LEDs, Room Sensor Status LED, Thermostat "A" output) Job Number: LL2OFE Page Prepared Date: 10/8/2020 Job Name: Brackets Point House 32 of 35 www.DaikinApplied.com Specification for WSHP SmartSource ALL a. Main Fan Switched output (line or low voltage) to control single speed fan operation b. Compressor Controls compressor operation (line or low voltage) c. Reversing Valve Controls reversing valve operation via low voltage. When the reversing valve output is de - energized, the reversing valve is in the "cool" position. d. Isolation Valve/Pump Request Switched output to send a signal that the water source heat pump requires liquid flow. e. 3 Board Status LED's Provides mode/alarm indication (SVDC). f. Room Sensor Status LED Provides unit status information (SVDC). g. Thermostat "A" Output 24VAC signal that turns on when the unit is in fault mode. R. The 1/0 expansion board shall provide a means of adding 1/0 capability to the base controller in the form of extra analog inputs, analog output, binary inputs, and binary outputs. The primary use of the 1/0 expansion board is variable speed fan control, two stage compressor operation, dehumidification, waterside economizer, and one or two stage electric heat. Some configurations may also require options such as fan speed control, hot gas reheat coil control, and electric heater coil control. 1. Analog Inputs: 2 total (entering water temperature, speed adjust signal): a. Entering Water Temperature (EWT) monitors entering water temperature by means of a 10k Ohm thermistor. b. Speed Adjust Signal a four position switch that selects user preferred fan speed. 2. Analog Output: 1 total (PWM signal) a. PWM Signal provides constant CFM or torque fan operation within maximum and minimum settings as defined in the fan motor control. 3. Binary Inputs: 2 total (Heat stage four, Humidistat) a. Heat stage four tells the Microtechlll unit controller that 2nd stage electric heat is required. b. Humidistat tells the Microtechlll unit controller that dehumidification is required. 4. Binary Output: 7 total (Compressor High Capacity, Auxillary heat stage 1, hot gas reheat, dehumidification/waterside economizer, auxillary heat stage 2, (3) status LED's) a. Compressor High Capacity 24VAC signal that enables the compressor at full load capacity. b. Auxiliary heat stage 1 24VAC signal that enables stage 1 electric heat. c. Hot Gas Re -Heat Dehumidification / Waterside Economizer enables the reheat solenoid on a request for dehumidification or controls the 3 -way diverting valve upon a call for waterside economizer depending on configuration. d. Auxiliary heat stage 2 24VAC signal that enables stage 2 electric heat. e. (3) status LED's SVDC signals that indicate operating conditions of the 1/0 expansion module. S. Emergency Shutdown: The controller will be in remote shutdown when the emergency shutdown contact closes to ground. Remote shutdown is provided so that when properly connected to a water loop controller or remote switch, the emergency shutdown input can be used to shut down the water source heat pump. When in remote shutdown no other thermostat or control inputs will have effect on unit operation. No faults or modes have higher priority than remote shutdown. Remote shutdown or brownout modes have the same level of priority. When the unit is in remote shutdown mode the following occurs: The compressor is immediately de-eliezgized (miliimum on timer is ignored) The revetsilig valve is immediately de -energized The fan is immediately de -energized The alarm output is de -energized. W heli the emeigelicy shutdown iliput is opened the unit will automatically returli to normal operation. Job Number: LL2OFE Page Prepared Date: 10/8/2020 Job Name: Brackets Point House 33 of 35 www.DaikinApplied.com Specification for WSHP SmartSource ALL T. Intelligent Reset: (Low pressure and Low temperature in heating only). The "Fault Retry' feature helps to minimize nuisance trips of automatic lockouts caused by low-pressure or low temperature faults. This feature automatically clears these faults the first two times they occur within a 24-hour period and triggers an automatic lockout on the 3rd fault. The retry count is reset to zero every 24 hours. The fault retry feature does not apply to a high pressure fault — which causes an immediate lockout and requires a manual reset, or condensate overflow or brownout faults—which are self -clearing. U. Microtech III Unit Controller and 1/0 Expansion Board Fault and Status LEDs: Separate remote LED boards will provide visual feedback for both control modules. 1. Room Sensor Status LED: A SVDC signal and shall operate as follows: Status LED Slade On continually Occupied, Occupied Load Shed On 0.5 sec, Off 5.5 sec Unoccupied On 5.5 sec. Off 0.5 sec Tenant Override. Override Load Shed On 0.1 sec, Off 0.1 sec Al= Condition (Condensate Overilow- Ermvrout, Compressor Fault) V. Auxiliary Relay Output: A 24VAC signal which is turned on when the unit is in alarm mode. Job Number: LL2OFE Page Prepared Date: 10/8/2020 Job Name: Brackets Point House 34 of 35 www.DaikinApplied.com AER13SEAL Brackets Point Project, X and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 4/26/2021 DUCT SEALING REPORT AEROSEAL CASE ID: 52 SYSTEM DESCRIPTION: SEAL DESCRIPTION: Sul HARDWARE: HomeSeal TECHNICIAN: Kevin C BEFORE SERVICE 40 35.7 CFM of Leakage, equivalent to a 6.7 Square Inch Hole or 8.9% of the system capacity of 400.0 CFM 30 AFTEF SERVICELn 3.5 CFM of Leakage, equivalent to a 20 0.7 Square Inch Hole or 0.86% of system capacity LL0 This corresponds to a 90% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. 1 C. 04 0 1 Sealing Time in Minutes 2 Aerosedl process uses UUGI?edl sedldnl Inas Is Geru➢eU Io meet FWUlrenlenls nsleu In UL 1,30 I sldnuaru- VUlllne or InV@srlyarlon ror Aerosol UUGr Jealarrr Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code LXTNRJZH. SmartSeal 4.3.2.8 (5261-22-60-218) 1 of 1 AEREISEAL Brackets Point Project, JK and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 4/26/2021 Overall Sealing BEFORE SERVICE 25.8 CFM of Leakage, equivalent to a 4.9 Square Inch Hole or 6.4% of the system capacity of 400.0 CFM AFTER SERVICE 1.1 CFM of Leakage, equivalent to a 0.2 Square Inch Hole or 0.28% of system capacity This corresponds to a 96% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. rsa��r �r�r-i is�rr4 a. a. � Zv�ti asr SO/sYC� y+Gsr! �GriY/FYI �CGrY�. DUCT SEALING REPORT AEROSEAL CASE ID: 5261 SYSTEM DESCRIPTION: Cold Stor SEAL DESCRIPTION: return 2 HARDWARE: HomeSeal Connect TECHNICIAN: Kevin C 3C 25 C20 L 17 0 CM 15 LL 10 5 04 0 SeElirg Tins it h+lirLt4=3 Select Mechanical Services 6219 Cambridge Street St. Louis Park, MN 55416 Phone: 952-926-4488 Aeroseal process uses DuctSeal sealant that is certified to meet requirements listed in UL 1381 standard -"Outline of investigation forAerosol Duct Sealant' Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code LXKNRJUL. SmartSeal 4.3.2.8 (5261-22-60-217) 1 of 1 AEREISEAL Brackets Point Project, JK and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 4/26/2021 Overall Sealing BEFORE SERVICE 7.0 CFM of Leakage, equivalent to a 1.3 Square Inch Hole or 1.7% of the system capacity of 400.0 CFM AFTER SERVICE 0.7 CFM of Leakage, equivalent to a 0.1 Square Inch Hole or 0.18% of system capacity This corresponds to a 90% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. rsa��r �r�r-i is�rr4 a. a. � Zv�ti asr 119.0 sr! a, Grit /'apr'I DUCT SEALING REPORT AEROSEAL CASE ID: 5261 SYSTEM DESCRIPTION: Cold Stor SEAL DESCRIPTION: Return 1 HARDWARE: HomeSeal Connect TECHNICIAN: Kevin C Select Mechanical Services 6219 Cambridge Street St. Louis Park, MN 55416 Phone: 952-926-4488 Aeroseal process uses DuctSeal sealant that is certified to meet requirements listed in UL 1381 standard -"Outline of investigation forAerosol Duct Sealant' Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code PGKNRJHG. SmartSeal 4.3.2.8 (5261-22-60-125) 1 of 1 AER13SEAL Brackets Point Project, X and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 4/28/2021 DUCT SEALING REPORT AEROSEAL CASE ID: 52 SYSTEM DESCRIPTION: SEAL DESCRIPTION: Su HARDWARE: HomeSeal TECHNICIAN: Kevin C BEFORE SERVICE 1 1 20 162.2 CFM of Leakage, equivalent to a 30.6 Square Inch Hole or 27% of the system capacity of 600.0 CFM 150 AFTEF SERVICE 12.7 CFM of Leakage, equivalent to a 100 2.4 Square Inch Hole or 2.1% of system capacity LLU This corresponds to a 92% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. 5C. 0+ 0 2 4 6 8 Sealing Time in Minutes 10 12 Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MMJNRJHT. SmartSeal 4.3.2.8 (5261-22-71-139) 1 of 1 AEREISEAL Brackets Point Project, JK and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 4/28/2021 Overall Sealing BEFORE SERVICE 71.7 CFM of Leakage, equivalent to a 13.5 Square Inch Hole or 12% of the system capacity of 600.0 CFM AFTER SERVICE 15.1 CFM of Leakage, equivalent to a 2.8 Square Inch Hole or 2.5% of system capacity This corresponds to a 79% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. rsa��r �r�r-i is�rr4 a. a. � Zv�ti asr SO/�YC� y+Gsr! �GriY/OYI ��rY�. DUCT SEALING REPORT AEROSEAL CASE ID: 5261 SYSTEM DESCRIPTION: HP126 SEAL DESCRIPTION: Return HARDWARE: HomeSeal Connect TECHNICIAN: Kevin C 121 100 M 8)] CL 17 0 CM 60 LL 40 20 2 4 6 a 1C. Sealing Time in Minutes Select Mechanical Services 6219 Cambridge Street St. Louis Park, MN 55416 Phone: 952-926-4488 Aeroseal process uses DuctSeal sealant that is certified to meet requirements listed in UL 1381 standard -"Outline of investigation for Aerosol Duct Sealant" Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MMTNRJQH. SmartSeal 4.3.2.8 (5261-22-71-138) 1 of 1 AER13SEAL Brackets Point Project, X and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 4/28/2021 DUCT SEALING REPORT AEROSEAL CASE ID: 52 SYSTEM DESCRIPTION: SEAL DESCRIPTION: Su HARDWARE: HomeSeal TECHNICIAN: Kevin C BEFORE SERVICE 1 1 23 200.1 CFM of Leakage, equivalent to a 37.8 Square Inch Hole or 200 14% of the system capacity of 1400.0 CFM AFTEF SERVICE M CL 150 12.2 CFM of Leakage, equivalent to a 2.3 Square Inch Hole or J 0.87% of system capacity 100 LL 0 This corresponds to a 94% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. 5C. I I I I I I I I I I 0 2 4 6 8 10 12 14 16 18 Sealing Time in Minutes Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MLKNRJTG. SmartSeal 4.3.2.8 (5261-22-72-141) 1 of 1 AEREISEAL Brackets Point Project, JK and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 4/28/2021 Overall Sealing BEFORE SERVICE 173.9 CFM of Leakage, equivalent to a 32.9 Square Inch Hole or 12% of the system capacity of 1400.0 CFM AFTER SERVICE 13.1 CFM of Leakage, equivalent to a 2.5 Square Inch Hole or 0.94% of system capacity This corresponds to a 92% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. rsa��r �r�r-i is�rr4 a. a. � Zv�ti asr SO/sYC� y+Gsr! �GriY/FYI �CGrY�. DUCT SEALING REPORT AEROSEAL CASE ID: 5261 SYSTEM DESCRIPTION: HP124 SEAL DESCRIPTION: Return HARDWARE: HomeSeal Connect TECHNICIAN: Kevin C 20 150 Im CL L: 100 50 2 4 6 a 1C. 12 SeElirg Tins it hAirrt:� Select Mechanical Services 6219 Cambridge Street St. Louis Park, MN 55416 Phone: 952-926-4488 Aeroseal process uses DuctSeal sealant that is certified to meet requirements listed in UL 1381 standard -"Outline of investigation forAerosol Duct Sealant' Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MLPNRJYN. SmartSeal 4.3.2.8 (5261-22-72-140) 1 of 1 AER13SEAL Brackets Point Project, X and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 10/11/2021 DUCT SEALING REPORT AEROSEAL CASE ID: 52 SYSTEM DESCRIPTION: SEAL DESCRIPTION: Su HARDWARE: HomeSeal TECHNICIAN: Kevin C BEFORE SERVICE I 1 -10 219.8 CFM of Leakage, equivalent to a 41.5 Square Inch Hole or 27% of the system capacity of 800.0 CFM 400 Im CL AFTEF SERVICE 300 030 14.6 CFM of Leakage, equivalent to a 2.8 Square Inch Hole or 1.8% of system capacity 200 LLU This corresponds to a 93% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. 1 C.C. 0+ 0 2 4 6 8 Sealing Time in Minutes 10 12 Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MNKNRJQW. SmartSeal 4.3.3.23 (5261-22-74-145) 1 of 1 AER13SEAL Brackets Point Project, X and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 10/11/2021 DUCT SEALING REPORT AEROSEAL CASE ID: 5261 SYSTEM DESCRIPTION: HP111 SEAL DESCRIPTION: Return HARDWARE: HomeSeal Connect TECHNICIAN: Kevin C BEFORE SERVICE 1 1 14 122.5 CFM of Leakage, equivalent to a 23.1 Square Inch Hole or 15% of the system capacity of 800.0 CFM �� 100 AFTEF SERVICE I� 12.4 CFM of Leakage, equivalent to a 2.3 Square Inch Hole or J 60 1.6% of system capacity U 40 This corresponds to a 90% Reduction 2C, in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. Ci C 1 2 3 4 .5 Sealing Time in Minutes 6 7 6 Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MNPNRJLQ. SmartSeal 4.3.3.23 (5261-22-74-144) 1 of 1 AER13SEAL Brackets Point Project, X and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 4/29/2021 DUCT SEALING REPORT AEROSEAL CASE ID: 52 SYSTEM DESCRIPTION: SEAL DESCRIPTION: Su HARDWARE: HomeSeal TECHNICIAN: Kevin C BEFORE SERVICE I 1 10 86.6 CFM of Leakage, equivalent to a 16.4 Square Inch Hole or 14% of the system capacity of 600.0 CFM 80 This corresponds to a 83% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. 2C. C+ C 1 2 3 4 .5 Sealing Time in Minutes 6 7 6 Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MNJNRJYP. SmartSeal 4.3.2.8 (5261-22-75-147) 1 of 1 AFTEF SERVICE 60 14.6 CFM of Leakage, equivalent to a 030 2.8 Square Inch Hole or J 2.4% of system capacity 40 LLU This corresponds to a 83% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. 2C. C+ C 1 2 3 4 .5 Sealing Time in Minutes 6 7 6 Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MNJNRJYP. SmartSeal 4.3.2.8 (5261-22-75-147) 1 of 1 AER13SEAL Brackets Point Project, X and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 4/29/2021 DUCT SEALING REPORT AEROSEAL CASE ID: 5261 SYSTEM DESCRIPTION: HP107 SEAL DESCRIPTION: Return HARDWARE: HomeSeal Connect TECHNICIAN: Kevin C BEFORE SERVICE 1 1 12' 104.1 CFM of Leakage, equivalent to a 19.7 Square Inch Hole or 100 17% of the system capacity of 600.0 CFM NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. Ci C 1 2 3 4 5 6 Sealing Time in Minutes 7 8 9 Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MNTNRJHX. SmartSeal 4.3.2.8 (5261-22-75-146) 1 of 1 � 80 AFTEF SERVICE 15.4 CFM of Leakage, equivalent to a 60 2.9 Square Inch Hole or J 2.6% of system capacity U 40 This corresponds to a 85% Reduction 2c. in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. Ci C 1 2 3 4 5 6 Sealing Time in Minutes 7 8 9 Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MNTNRJHX. SmartSeal 4.3.2.8 (5261-22-75-146) 1 of 1 AER13SEAL Brackets Point Project, JK and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 10/18/2021 Overall Sealing BEFORE SERVICE 50.6 CFM of Leakage, equivalent to a 9.6 Square Inch Hole or 2.5% of the system capacity of 2000.0 CFM AFTER SERVICE 6.5 CFM of Leakage, equivalent to a 1.2 Square Inch Hole or 0.33% of system capacity This corresponds to a 87% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. rsa��r �r�r-i is�rr4 a. a. � Zv�ti asr SO/�YC� y+Gsr! �GriY/OYI ��rY�. DUCT SEALING REPORT AEROSEAL CASE ID: 5261 SYSTEM DESCRIPTION: HP101B SEAL DESCRIPTION: Return HARDWARE: HomeSeal Connect TECHNICIAN: Kevin C 6( C40 L LI) �3 0 03 LL 20 04 0 1 2 3 4 Sealing Time in Minutes Select Mechanical Services 6219 Cambridge Street St. Louis Park, MN 55416 Phone: 952-926-4488 5 6 Aeroseal process uses DuctSeal sealant that is certified to meet requirements listed in UL 1381 standard -"Outline of investigation for Aerosol Duct Sealant" Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MKPNRJTY. SmartSeal 4.3.3.23 (5261-22-76-148) 1 of 1 AEREISEAL Brackets Point Project, JK and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 10/11/2021 Overall Sealing BEFORE SERVICE 56.2 CFM of Leakage, equivalent to a 10.6 Square Inch Hole or 3.5% of the system capacity of 1600.0 CFM AFTER SERVICE 17.8 CFM of Leakage, equivalent to a 3.4 Square Inch Hole or 1.1% of system capacity This corresponds to a 68% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. rsa��r �r�r-i is�rr4 a. a. � Zv�ti asr SO/�YC� y+Gsr! �GriY/OYI ��rY�. DUCT SEALING REPORT AEROSEAL CASE ID: 5261 SYSTEM DESCRIPTION: HP101A SEAL DESCRIPTION: Return HARDWARE: HomeSeal Connect TECHNICIAN: Kevin C 6( :96 L: Q LL 20 04 0 1 2 3 4 Sealing Time in Minutes Select Mechanical Services 6219 Cambridge Street St. Louis Park, MN 55416 Phone: 952-926-4488 S Aeroseal process uses DuctSeal sealant that is certified to meet requirements listed in UL 1381 standard -"Outline of investigation for Aerosol Duct Sealant" Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MKTNRJKM. SmartSeal 4.3.3.23 (5261-22-77-150) 1 of 1 AER13SEAL Brackets Point Project, X and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 4/28/2021 DUCT SEALING REPORT AEROSEAL CASE ID: 52 SYSTEM DESCRIPTION: SEAL DESCRIPTION: Su HARDWARE: HomeSeal TECHNICIAN: Kevin C BEFORE SERVICE 1 1 23 230.7 CFM of Leakage, equivalent to a 43.6 Square Inch Hole or 200 12% of the system capacity of 2000.0 CFM M CL AFTEF SERVICE 150 11.6 CFM of Leakage, equivalent to a 2.2 Square Inch Hole or 0.58% of system capacity 100 LL 0 This corresponds to a 95% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. 5C. I I I I I I I I I I 0 2 4 6 8 10 12 14 '6 "S Sealing Time in Minutes Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MXKNRJHL. SmartSeal 4.3.2.8 (5261-22-78-153) 1 of 1 AEREISEAL Brackets Point Project, JK and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 4/28/2021 Overall Sealing BEFORE SERVICE 38.9 CFM of Leakage, equivalent to a 7.4 Square Inch Hole or 1.9% of the system capacity of 2000.0 CFM AFTER SERVICE 12.9 CFM of Leakage, equivalent to a 2.4 Square Inch Hole or 0.64% of system capacity This corresponds to a 67% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. rsa��r �r�r-i is�rr4 a. a. � Zv�ti asr SO/sYC� y+Gsr! �GriY/FYI �CGrY�. DUCT SEALING REPORT AEROSEAL CASE ID: 5261 SYSTEM DESCRIPTION: HP033 SEAL DESCRIPTION: Return HARDWARE: HomeSeal Connect TECHNICIAN: Kevin C 4{ 30 10 04 0 1 2 3 4 S Sealing Time in hffinutes Select Mechanical Services 6219 Cambridge Street St. Louis Park, MN 55416 Phone: 952-926-4488 Aeroseal process uses DuctSeal sealant that is certified to meet requirements listed in UL 1381 standard -"Outline of investigation forAerosol Duct Sealant' Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MXPNRJQR. SmartSeal 4.3.2.8 (5261-22-78-152) 1 of 1 AER13SEAL Brackets Point Project, X and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: L 10/18/2021 DUCT SEALING REPORT AEROSEAL CASE ID: 52 SYSTEM DESCRIPTION: SEAL DESCRIPTION: Su HARDWARE: HomeSeal TECHNICIAN: Kevin C BEFORE SERVICE 1 1 121 113.2 CFM of Leakage, equivalent to a 21.4 Square Inch Hole or 100 7.1% of the system capacity of 1600.0 CFM NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. 0+ 0 2 4 S & Sealing Time in Minutes 1 C. Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MXJNRJTT. SmartSeal 4.3.3.23 (5261-22-79-155) 1 of 1 � 80 AFTEF SERVICE 7.2 CFM of Leakage, equivalent to a 60 1.4 Square Inch Hole or J 0.45% of system capacity U 40 This corresponds to a 94% Reduction 2C. in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. 0+ 0 2 4 S & Sealing Time in Minutes 1 C. Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MXJNRJTT. SmartSeal 4.3.3.23 (5261-22-79-155) 1 of 1 AEREISEAL Brackets Point Project, JK and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 10/18/2021 Overall Sealing BEFORE SERVICE 60.9 CFM of Leakage, equivalent to a 11.5 Square Inch Hole or 3.8% of the system capacity of 1600.0 CFM AFTER SERVICE 15.3 CFM of Leakage, equivalent to a 2.9 Square Inch Hole or 0.95% of system capacity This corresponds to a 75% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. rsa��r �r�r-i is�rr4 a. a. � Zv�ti asr SO/sYC� y+Gsr! �GriY/FYI �CGrY�. DUCT SEALING REPORT AEROSEAL CASE ID: 5261 SYSTEM DESCRIPTION: HP026 SEAL DESCRIPTION: Return HARDWARE: HomeSeal Connect TECHNICIAN: Kevin C 8( 60 L: 17 0 40 20 04 0 1 2 3 4 5 6 ? Sealing Time in hffinutes Select Mechanical Services 6219 Cambridge Street St. Louis Park, MN 55416 Phone: 952-926-4488 Aeroseal process uses DuctSeal sealant that is certified to meet requirements listed in UL 1381 standard -"Outline of investigation forAerosol Duct Sealant' Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MXTNRJWH. SmartSeal 4.3.3.23 (5261-22-79-154) 1 of 1 AEREISEAL Brackets Point Project, JK and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 10/18/2021 Overall Sealing BEFORE SERVICE 169.2 CFM of Leakage, equivalent to a 32.0 Square Inch Hole or 42% of the system capacity of 400.0 CFM AFTER SERVICE 15.4 CFM of Leakage, equivalent to a 2.9 Square Inch Hole or 3.9% of system capacity This corresponds to a 91% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. rsa��r �r�r-i is�rr4 a. a. � Zv�ti asr SO/sYC� y+Gsr! �GriY/FYI �CGrY�. DUCT SEALING REPORT AEROSEAL CASE ID: 5261 SYSTEM DESCRIPTION: HP021 SEAL DESCRIPTION: Supply HARDWARE: HomeSeal Connect TECHNICIAN: Kevin C 2O[ 150 sa C 11.0 y�y�y J LL .J 50 2 4 6 a 1C. 12 Sealing Time in Knubas Select Mechanical Services 6219 Cambridge Street St. Louis Park, MN 55416 Phone: 952-926-4488 Aeroseal process uses DuctSeal sealant that is certified to meet requirements listed in UL 1381 standard -"Outline of investigation forAerosol Duct Sealant' Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MZKNRJNG. SmartSeal 4.3.3.23 (5261-22-80-157) 1 of 1 AER13SEAL Brackets Point Project, X and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: L 10/18/2021 DUCT SEALING REPORT AEROSEAL CASE ID: 5261 SYSTEM DESCRIPTION: HP021 SEAL DESCRIPTION: Return HARDWARE: HomeSeal Connect TECHNICIAN: Kevin C BEFORE SERVICE 1 1 20 164.5 CFM of Leakage, equivalent to a 31.1 Square Inch Hole or 41 % of the system capacity of 400.0 CFM 150 AFTEF SERVICE 11.8 CFM of Leakage, equivalent to a 100 2.2 Square Inch Hole or 3.0% of system capacity LLU This corresponds to a 93% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. 5C. 0+ 0 2 4 6 8 10 Sealing Time in Minutes 12 14 Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MZPNRJZN. SmartSeal 4.3.3.23 (5261-22-80-156) 1 of 1 AER13SEAL Brackets Point Project, X and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: L 10/18/2021 DUCT SEALING REPORT AEROSEAL CASE ID: 52 SYSTEM DESCRIPTION: SEAL DESCRIPTION: Su HARDWARE: HomeSeal TECHNICIAN: Kevin C BEFORE SERVICE 1 1 20 165.0 CFM of Leakage, equivalent to a 31.2 Square Inch Hole or 14% of the system capacity of 1200.0 CFM 150 AFTEF SERVICE 8.7 CFM of Leakage, equivalent to a 100 1.6 Square Inch Hole or 0.73% of system capacity LLU This corresponds to a 95% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. 5C. 0+ 0 2 4 6 8 10 Sealing Time in Minutes 12 14 Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MZJNRJQK. SmartSeal 4.3.3.23 (5261-22-81-159) 1 of 1 AER13SEAL Brackets Point Project, JK and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 10/18/2021 Overall Sealing BEFORE SERVICE 104.7 CFM of Leakage, equivalent to a 19.8 Square Inch Hole or 8.7% of the system capacity of 1200.0 CFM AFTER SERVICE 12.1 CFM of Leakage, equivalent to a 2.3 Square Inch Hole or 1.0% of system capacity This corresponds to a 88% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. rsa��r �r�r-i is�rr4 a. a. � Zv�ti asr SO/�YC� y+Gsr! �GriY/OYI ��rY�. DUCT SEALING REPORT AEROSEAL CASE ID: 5261 SYSTEM DESCRIPTION: HP020 SEAL DESCRIPTION: Return HARDWARE: HomeSeal Connect TECHNICIAN: Kevin C 12{ 100 M so CL 17 0 CM 60 LL 40 20 2 4 6 a 10 SeElirg Tins it hAirLts3 Select Mechanical Services 6219 Cambridge Street St. Louis Park, MN 55416 Phone: 952-926-4488 Aeroseal process uses DuctSeal sealant that is certified to meet requirements listed in UL 1381 standard -"Outline of investigation for Aerosol Duct Sealant" Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MZTNRJMU. SmartSeal 4.3.3.23 (5261-22-81-158) 1 of 1 AER13SEAL Brackets Point Project, X and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: L 10/18/2021 DUCT SEALING REPORT AEROSEAL CASE ID: 52 SYSTEM DESCRIPTION: SEAL DESCRIPTION: Su HARDWARE: HomeSeal TECHNICIAN: Kevin C BEFORE SERVICE I 1 35 309.7 CFM of Leakage, equivalent to a 58.5 Square Inch Hole or 26% of the system capacity of 1200.0 CFM 250 AFTEF SERVICE � 200 6.9 CFM of Leakage, equivalent to a 1.3 Square Inch Hole or J 150 0.57% of system capacity U 1 C.C. This corresponds to a 98% Reduction 5C, in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. C+ C 1 2 3 4 5 Sealing Time in Minutes 6 ? Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MRKNRJWW. SmartSeal 4.3.3.23 (5261-22-82-161) 1 of 1 AER13SEAL Brackets Point Project, JK and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 10/18/2021 Overall Sealing BEFORE SERVICE 61.8 CFM of Leakage, equivalent to a 11.7 Square Inch Hole or 5.1% of the system capacity of 1200.0 CFM AFTER SERVICE 16.3 CFM of Leakage, equivalent to a 3.1 Square Inch Hole or 1.4% of system capacity This corresponds to a 74% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. rsa��r �r�r-i is�rr4 a. a. � Zv�ti asr SO/sYC� y+Gsr! �GriY/FYI �CGrY�. DUCT SEALING REPORT AEROSEAL CASE ID: 5261 SYSTEM DESCRIPTION: HP018B SEAL DESCRIPTION: Return HARDWARE: HomeSeal Connect TECHNICIAN: Kevin C 8( 60 M CL 17 0 40 J LL 20 0 1 2 3 4 SeElirg Tins it h+lirLt4=3 Select Mechanical Services 6219 Cambridge Street St. Louis Park, MN 55416 Phone: 952-926-4488 Aeroseal process uses DuctSeal sealant that is certified to meet requirements listed in UL 1381 standard -"Outline of investigation forAerosol Duct Sealant' Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MRPNRJHQ. SmartSeal 4.3.3.23 (5261-22-82-160) 1 of 1 AEREISEAL Brackets Point Project, JK and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 10/11/2021 Overall Sealing BEFORE SERVICE 75.7 CFM of Leakage, equivalent to a 14.3 Square Inch Hole or 6.3% of the system capacity of 1200.0 CFM AFTER SERVICE 16.8 CFM of Leakage, equivalent to a 3.2 Square Inch Hole or 1.4% of system capacity This corresponds to a 78% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. rsa��r �r�r-i is�rr4 a. a. � Zv�ti asr SO/�YC� y+Gsr! �GriY/OYI ��rY�. DUCT SEALING REPORT AEROSEAL CASE ID: 5261 SYSTEM DESCRIPTION: HP018A SEAL DESCRIPTION: Supply HARDWARE: HomeSeal Connect TECHNICIAN: Kevin C 8( 60 L: 17 0 40 20 04 0 1 2 3 4 5 6 Sealing Time in Minutes Select Mechanical Services 6219 Cambridge Street St. Louis Park, MN 55416 Phone: 952-926-4488 Aeroseal process uses DuctSeal sealant that is certified to meet requirements listed in UL 1381 standard -"Outline of investigation for Aerosol Duct Sealant" Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MRJNRJZP. SmartSeal 4.3.3.23 (5261-22-83-163) 1 of 1 AER13SEAL Brackets Point Project, X and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 10/11/2021 DUCT SEALING REPORT AEROSEAL CASE ID: 5261 SYSTEM DESCRIPTION: HP018A SEAL DESCRIPTION: Return HARDWARE: HomeSeal Connect TECHNICIAN: Kevin C BEFORE SERVICE 1 1 141 128.2 CFM of Leakage, equivalent to a 24.2 Square Inch Hole or �� 11 % of the system capacity of 1200.0 CFM 100 AFTEF SERVICE I� 8.5 CFM of Leakage, equivalent to a 1.6 Square Inch Hole or J 60 0.71% of system capacity LLU 40 This corresponds to a 93% Reduction 2C, in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. 0+ 0 2 4 6 8 10 Sealing Time in Minutes 12 14 Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MRTNRJTX. SmartSeal 4.3.3.23 (5261-22-83-162) 1 of 1 AEREISEAL Brackets Point Project, JK and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 10/11/2021 Overall Sealing BEFORE SERVICE 174.5 CFM of Leakage, equivalent to a 33.0 Square Inch Hole or 29% of the system capacity of 600.0 CFM AFTER SERVICE 10.7 CFM of Leakage, equivalent to a 2.0 Square Inch Hole or 1.8% of system capacity This corresponds to a 94% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. rsa��r �r�r-i is�rr4 a. a. � Zv�ti asr SO/sYC� y+Gsr! �GriY/FYI �CGrY�. DUCT SEALING REPORT AEROSEAL CASE ID: 5261 SYSTEM DESCRIPTION: HP015 SEAL DESCRIPTION: Supply HARDWARE: HomeSeal Connect TECHNICIAN: Kevin C 2{X 150 Im CL L: 100 50 2 4 6 a 1C. 12 Sealing Time in Knubas Select Mechanical Services 6219 Cambridge Street St. Louis Park, MN 55416 Phone: 952-926-4488 Aeroseal process uses DuctSeal sealant that is certified to meet requirements listed in UL 1381 standard -"Outline of investigation forAerosol Duct Sealant' Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MTJNRJJJ. SmartSeal 4.3.3.23 (5261-22-85-167) 1 of 1 AER13SEAL Brackets Point Project, X and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 10/11/2021 DUCT SEALING REPORT AEROSEAL CASE ID: 5261 SYSTEM DESCRIPTION: HP015 SEAL DESCRIPTION: Return HARDWARE: HomeSeal Connect TECHNICIAN: Kevin C BEFORE SERVICE 1 1 20 166.3 CFM of Leakage, equivalent to a 31.4 Square Inch Hole or 28% of the system capacity of 600.0 CFM 150 AFTEF SERVICE 4.2 CFM of Leakage, equivalent to a 100 0.8 Square Inch Hole or 0.70% of system capacity LLU This corresponds to a 97% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. 5C. 0+ 0 2 4 6 8 70 Sealing Time in Minutes 12 14 Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MTTNRJQM. SmartSeal 4.3.3.23 (5261-22-85-166) 1 of 1 AEREISEAL Brackets Point Project, JK and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 4/29/2021 Overall Sealing BEFORE SERVICE 94.6 CFM of Leakage, equivalent to a 17.9 Square Inch Hole or 24% of the system capacity of 400.0 CFM AFTER SERVICE 15.0 CFM of Leakage, equivalent to a 2.8 Square Inch Hole or 3.7% of system capacity This corresponds to a 84% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. rsa��r �r�r-i is�rr4 a. a. � Zv�ti asr SO/sYC� y+Gsr! �GriY/FYI �CGrY�. DUCT SEALING REPORT AEROSEAL CASE ID: 5261 SYSTEM DESCRIPTION: HP005 SEAL DESCRIPTION: Supply HARDWARE: HomeSeal Connect TECHNICIAN: Kevin C 2 4 6 a 1C. Sealing Time in Knubas Select Mechanical Services 6219 Cambridge Street St. Louis Park, MN 55416 Phone: 952-926-4488 Aeroseal process uses DuctSeal sealant that is certified to meet requirements listed in UL 1381 standard -"Outline of investigation forAerosol Duct Sealant' Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MWJNRJWK. SmartSeal 4.3.2.8 (5261-22-89-175) 1 of 1 AEREISEAL Brackets Point Project, JK and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 4/29/2021 Overall Sealing BEFORE SERVICE 86.2 CFM of Leakage, equivalent to a 16.3 Square Inch Hole or 22% of the system capacity of 400.0 CFM #Error This corresponds to a 84% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. rsa��r �r�r-i is�rr4 a. a. � Zv�ti asr SO/�YC� y+Gsr! �GriY/OYI ��rY�. DUCT SEALING REPORT AEROSEAL CASE ID: 5261 SYSTEM DESCRIPTION: HP005 SEAL DESCRIPTION: Return HARDWARE: HomeSeal Connect TECHNICIAN: Kevin C 2 4 6 a 1C. Sealing Time in Minutes Select Mechanical Services 6219 Cambridge Street St. Louis Park, MN 55416 Phone: 952-926-4488 Aeroseal process uses DuctSeal sealant that is certified to meet requirements listed in UL 1381 standard -"Outline of investigation for Aerosol Duct Sealant" Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MWTNRJJU. SmartSeal 4.3.2.8 (5261-22-89-174) 1 of 1 AER13SEAL Brackets Point Project, X and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 10/11/2021 DUCT SEALING REPORT AEROSEAL CASE ID: 52 SYSTEM DESCRIPTION: SEAL DESCRIPTION: Su HARDWARE: HomeSeal TECHNICIAN: Kevin C BEFORE SERVICE I 1 -15 279.7 CFM of Leakage, equivalent to a 52.8 Square Inch Hole or 300 17% of the system capacity of 1600.0 CFM 250 M CL AFTEF SERVICE C Ili 200 12.8 CFM of Leakage, equivalent to a 2.4 Square Inch Hole or J 10 0.80% of system capacity c� 700 This corresponds to a 95% Reduction 50 in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. I I I I I I I I I I 0 2 4 6 8 19 12 14 '6 "S Sealing Time in Minutes Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MYKNRJXW. SmartSeal 4.3.3.23 (5261-22-90-177) 1 of 1 AER13SEAL Brackets Point Project, X and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 10/11/2021 DUCT SEALING REPORT AEROSEAL CASE ID: 5261 SYSTEM DESCRIPTION: HP003 SEAL DESCRIPTION: Return HARDWARE: HomeSeal Connect TECHNICIAN: Kevin C BEFORE SERVICE 1 1 23 220.1 CFM of Leakage, equivalent to a 41.6 Square Inch Hole or 200 14% of the system capacity of 1600.0 CFM Im CL AFTEF SERVICE 150 030 22.2 CFM of Leakage, equivalent to a 4.2 Square Inch Hole or 1.4% of system capacity 100 LLU This corresponds to a 90% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. 5C. 0+ 0 2 4 6 8 Sealing Time in Minutes 10 12 Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MYPNRJTQ. SmartSeal 4.3.3.23 (5261-22-90-176) 1 of 1 AER13SEAL Brackets Point Project, X and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 4/28/2021 DUCT SEALING REPORT AEROSEAL CASE ID: 5261 SYSTEM DESCRIPTION: HP219 SEAL DESCRIPTION: Retun HARDWARE: HomeSeal Connect TECHNICIAN: Kevin C BEFORE SERVICE I 1 70 89.0 CFM of Leakage, equivalent to a 16.8 Square Inch Hole or 22% of the system capacity of 400.0 CFM AFTEF SERVICE 60 030 12.5 CFM of Leakage, equivalent to a 2.4 Square Inch Hole or 3.1% of system capacity 40 LLU This corresponds to a 86% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. 2C. C+ C 1 2 3 4 .5 Sealing Time in Minutes 6 7 6 Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code PHKNRJRL. SmartSeal 4.3.2.8 (5261-22-64-121) 1 of 1 AER13;EAL, Brackets Point Project, X and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 3/21/2022 BEFORE SERVICE 356.8 CFM of Leakage, equivalent to a 67.4 Square Inch Hole or 18% of the system capacity of 2000.0 CFM AFTER SERVICE 10.7 CFM of Leakage, equivalent to a 2.0 Square Inch Hole or 0.54% of system capacity This corresponds to a 97% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. DUCT SEALING REPORT AEROSEAL CASE ID: 5261 SYSTEM DESCRIPTION: HP101B SEAL DESCRIPTION: Supply HARDWARE: HomeSeal Connect TECHNICIAN: Kevin C =fd 3 C C M CL 200 J M ILLU 1 C.C. I I I I I I I I I I I - 6 9 10 12 14 16 18 24 v=lir Time in Minutes I"LGI WI'A1 FIIVUWJ UJW UUU-- -011-IIL LIICIL IJ UGI lII1GU LV IIII-L I HUI-111G11LJ I-- III - IJV I JLCIIIUCIIU- VULIIIIG VI -L --alit Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MKKNRJZZ. SmartSeal 4.3.4.11 (5261-22-76-149) 1 of 1 AER13;EAL, Brackets Point Project, X and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 3/21/2022 BEFORE SERVICE 138.5 CFM of Leakage, equivalent to a 26.2 Square Inch Hole or 8.7% of the system capacity of 1600.0 CFM AFTER SERVICE 10.8 CFM of Leakage, equivalent to a 2.0 Square Inch Hole or 0.68% of system capacity This corresponds to a 92% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. DUCT SEALING REPORT AEROSEAL CASE ID: 5261 SYSTEM DESCRIPTION: HP101A SEAL DESCRIPTION: Supply HARDWARE: HomeSeal Connect TECHNICIAN: Kevin C 20( 15C Im CL Ln 100 J ILL 5C. 2 4 6 8 10 12 14 v v=iir Tins in Minutes I"LGI WI'A1 FIIVUWJ UJW UUU-- -011-IIL LIICIL IJ UGI lII1GU LV IIII-L I HUI-111G11LJ I-- III - IJV I JLGIIUQIU- VULIIIIG VI -L --alit Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MKJNRJMJ. SmartSeal 4.3.4.11 (5261-22-77-151) 1 of 1 AEREISEAL Brackets Point Project, JK and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 4/26/2021 Overall Sealing BEFORE SERVICE 10.5 CFM of Leakage, equivalent to a 2.0 Square Inch Hole or 1.3% of the system capacity of 800.0 CFM AFTER SERVICE 11.9 CFM of Leakage, equivalent to a 2.2 Square Inch Hole or 1.5% of system capacity This corresponds to a -12.85% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. rsa��r �r�r-i is�rr4 a. a. � Zv�ti asr SO/sYC� y+Gsr! �GriY/FYI �CGrY�. DUCT SEALING REPORT AEROSEAL CASE ID: 5261 SYSTEM DESCRIPTION: HP238 SEAL DESCRIPTION: Supply HARDWARE: HomeSeal Connect TECHNICIAN: Kevin C 7t 10 M 8 CL 17 0 C C 6 LL 4 2 04 0 1 2 3 SeElirg Tins it h+lirLt4=3 Select Mechanical Services 6219 Cambridge Street St. Louis Park, MN 55416 Phone: 952-926-4488 Aeroseal process uses DuctSeal sealant that is certified to meet requirements listed in UL 1381 standard -"Outline of investigation forAerosol Duct Sealant' Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code PJPNRJLY. SmartSeal 4.3.2.8 (5261-22-61-116) 1 of 1 AEREISEAL Brackets Point Project, JK and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 4/26/2021 Overall Sealing BEFORE SERVICE 10.7 CFM of Leakage, equivalent to a 2.0 Square Inch Hole or 1.3% of the system capacity of 800.0 CFM AFTER SERVICE 11.4 CFM of Leakage, equivalent to a 2.2 Square Inch Hole or 1.4% of system capacity This corresponds to a -6.28% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. rsa��r �r�r-i is�rr4 a. a. � Zv�ti asr SO/sYC� y+Gsr! �GriY/FYI �CGrY�. DUCT SEALING REPORT AEROSEAL CASE ID: 5261 SYSTEM DESCRIPTION: HP238 SEAL DESCRIPTION: Return HARDWARE: HomeSeal Connect TECHNICIAN: Kevin C 10 3 L: 17 0 C C 6 LL 4 2 04 0 1 2 Sealing Time in hffinutes Select Mechanical Services 6219 Cambridge Street St. Louis Park, MN 55416 Phone: 952-926-4488 Aeroseal process uses DuctSeal sealant that is certified to meet requirements listed in UL 1381 standard -"Outline of investigation forAerosol Duct Sealant' Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code PYJNRJXP. SmartSeal 4.3.2.8 (5261-22-61-115) 1 of 1 AER13SEAL Brackets Point Project, X and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 4/27/2021 DUCT SEALING REPORT AEROSEAL CASE ID: 52 SYSTEM DESCRIPTION: SEAL DESCRIPTION: Su HARDWARE: HomeSeal TECHNICIAN: Kevin C BEFORE SERVICE 1 1 12' 101.5 CFM of Leakage, equivalent to a 19.2 Square Inch Hole or 100 8.5% of the system capacity of 1200.0 CFM NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. 0+ 0 2 4 8 8 Sealing Time in Minutes 10 12 Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code PJKNRJPZ. SmartSeal 4.3.2.8 (5261-22-62-117) 1 of 1 � 80 AFTEF SERVICE 14.9 CFM of Leakage, equivalent to a 60 2.8 Square Inch Hole or J 1.2% of system capacity U 40 This corresponds to a 85% Reduction 2c. in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. 0+ 0 2 4 8 8 Sealing Time in Minutes 10 12 Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code PJKNRJPZ. SmartSeal 4.3.2.8 (5261-22-62-117) 1 of 1 AER13SEAL Brackets Point Project, X and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 4/27/2021 DUCT SEALING REPORT AEROSEAL CASE ID: 5261 SYSTEM DESCRIPTION: HP232 SEAL DESCRIPTION: Return HARDWARE: HomeSeal Connect TECHNICIAN: Kevin C BEFORE SERVICE I 1 70 81.3 CFM of Leakage, equivalent to a 15.4 Square Inch Hole or 6.8% of the system capacity of 1200.0 CFM 80 This corresponds to a 80% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. 2C. C+ C 1 2 3 4 .5 Sealing Time in Minutes 6 7 6 Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code PJTNRJGM. SmartSeal 4.3.2.8 (5261-22-62-118) 1 of 1 AFTEF SERVICE 60 16.4 CFM of Leakage, equivalent to a 030 3.1 Square Inch Hole or J 1.4% of system capacity 40 LLU This corresponds to a 80% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. 2C. C+ C 1 2 3 4 .5 Sealing Time in Minutes 6 7 6 Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code PJTNRJGM. SmartSeal 4.3.2.8 (5261-22-62-118) 1 of 1 AER13SEAL Brackets Point Project, X and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 4/28/2021 DUCT SEALING REPORT AEROSEAL CASE ID: 52 SYSTEM DESCRIPTION: SEAL DESCRIPTION: Su HARDWARE: HomeSeal TECHNICIAN: Kevin C BEFORE SERVICE I 1 9 41.3 CFM of Leakage, equivalent to a 7.8 Square Inch Hole or 40 3.4% of the system capacity of 1200.0 CFM AFTEF SERVICE 30 10.3 CFM of Leakage, equivalent to a 1.9 Square Inch Hole or 0.86% of system capacity 20 LLU This corresponds to a 75% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. 1 C. 04 0 1 2 3 4 5 Sealing Time in Minutes G Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code PHPNRJUR. SmartSeal 4.3.2.8 (5261-22-63-120) 1 of 1 AER13SEAL Brackets Point Project, X and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 4/28/2021 DUCT SEALING REPORT AEROSEAL CASE ID: 5261 SYSTEM DESCRIPTION: HP223 SEAL DESCRIPTION: Return HARDWARE: HomeSeal Connect TECHNICIAN: Kevin C BEFORE SERVICE I 1 9 38.1 CFM of Leakage, equivalent to a 7.2 Square Inch Hole or 40 3.2% of the system capacity of 1200.0 CFM AFTEF SERVICE 30 11.8 CFM of Leakage, equivalent to a 2.2 Square Inch Hole or 0.99% of system capacity 20 LLU This corresponds to a 69% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. 1 C. 04 0 1 2 3 4 Sealing Time in Minutes S Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code PJJNRJYJ. SmartSeal 4.3.2.8 (5261-22-63-119) 1 of 1 AER13SEAL Brackets Point Project, X and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 4/28/2021 DUCT SEALING REPORT AEROSEAL CASE ID: 52 SYSTEM DESCRIPTION: SEAL DESCRIPTION: Su HARDWARE: HomeSeal TECHNICIAN: Kevin C BEFORE SERVICE 1 1 121 102.6 CFM of Leakage, equivalent to a 19.4 Square Inch Hole or 100 26% of the system capacity of 400.0 CFM NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. 0+ 0 2 4 S & Sealing Time in Minutes 1 C. Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code PHTNRJKH. SmartSeal 4.3.2.8 (5261-22-64-122) 1 of 1 � 80 AFTEF SERVICE 10.5 CFM of Leakage, equivalent to a 60 2.0 Square Inch Hole or J 2.6% of system capacity U 40 This corresponds to a 90% Reduction 2C. in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. 0+ 0 2 4 S & Sealing Time in Minutes 1 C. Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code PHTNRJKH. SmartSeal 4.3.2.8 (5261-22-64-122) 1 of 1 AEREISEAL Brackets Point Project, JK and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 4/27/2021 Overall Sealing BEFORE SERVICE 17.4 CFM of Leakage, equivalent to a 3.3 Square Inch Hole or 4.4% of the system capacity of 400.0 CFM AFTER SERVICE 11.4 CFM of Leakage, equivalent to a 2.2 Square Inch Hole or 2.9% of system capacity This corresponds to a 34% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. rsa��r �r�r-i is�rr4 a. a. � Zv�ti asr 119.0 sr! a, Grit /'apr'I DUCT SEALING REPORT AEROSEAL CASE ID: 5261 SYSTEM DESCRIPTION: HP209 SEAL DESCRIPTION: Supply HARDWARE: HomeSeal Connect TECHNICIAN: Kevin C Select Mechanical Services 6219 Cambridge Street St. Louis Park, MN 55416 Phone: 952-926-4488 Aeroseal process uses DuctSeal sealant that is certified to meet requirements listed in UL 1381 standard -"Outline of investigation forAerosol Duct Sealant' Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code PGJNRJUK. SmartSeal 4.3.2.8 (5261-22-65-127) 1 of 1 AER13SEAL Brackets Point Project, X and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 4/27/2021 DUCT SEALING REPORT AEROSEAL CASE ID: 5261 SYSTEM DESCRIPTION: HP209 SEAL DESCRIPTION: Return HARDWARE: HomeSeal Connect TECHNICIAN: Kevin C BEFORE SERVICE 25 24.6 CFM of Leakage, equivalent to a 4.7 Square Inch Hole or 6.2% of the system capacity of 400.0 CFM 20 Im CL 15 AFTEF SERVICE 15.6 CFM of Leakage, equivalent to a 030 3.0 Square Inch Hole or J 3.9% of system capacityLL U This corresponds to a 37% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. 5 04 0 1 2 3 4 5 Sealing Time in Minutes G Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code PGTNRJYU. SmartSeal 4.3.2.8 (5261-22-65-126) 1 of 1 AEREISEAL Brackets Point Project, JK and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 4/27/2021 Overall Sealing BEFORE SERVICE 31.8 CFM of Leakage, equivalent to a 6.0 Square Inch Hole or 8.0% of the system capacity of 400.0 CFM AFTER SERVICE 12.8 CFM of Leakage, equivalent to a 2.4 Square Inch Hole or 3.2% of system capacity This corresponds to a 60% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. rsa��r �r�r-i is�rr4 a. a. � Zv�ti asr SO/sYC� y+Gsr! �GriY/FYI �CGrY�. DUCT SEALING REPORT AEROSEAL CASE ID: 5261 SYSTEM DESCRIPTION: HP208 SEAL DESCRIPTION: Supply HARDWARE: HomeSeal Connect TECHNICIAN: Kevin C 31- 30 F 30 25 10 5 04 0 Sealing Time in hffinutes Select Mechanical Services 6219 Cambridge Street St. Louis Park, MN 55416 Phone: 952-926-4488 2 Aeroseal process uses DuctSeal sealant that is certified to meet requirements listed in UL 1381 standard -"Outline of investigation forAerosol Duct Sealant' Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MQKNRJKW. SmartSeal 4.3.2.8 (5261-22-66-129) 1 of 1 AEREISEAL Brackets Point Project, JK and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 4/27/2021 Overall Sealing BEFORE SERVICE 32.5 CFM of Leakage, equivalent to a 6.1 Square Inch Hole or 8.1 % of the system capacity of 400.0 CFM AFTER SERVICE 13.5 CFM of Leakage, equivalent to a 2.6 Square Inch Hole or 3.4% of system capacity This corresponds to a 58% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. rsa��r �r�r-i is�rr4 a. a. � Zv�ti asr SO/�YC� y+Gsr! �GriY/OYI ��rY�. DUCT SEALING REPORT AEROSEAL CASE ID: 5261 SYSTEM DESCRIPTION: HP208 SEAL DESCRIPTION: Return HARDWARE: HomeSeal Connect TECHNICIAN: Kevin C 31- 30 F 30 25 n 20 15 LL 10 5 04 0 Sealing Time in Minutes Select Mechanical Services 6219 Cambridge Street St. Louis Park, MN 55416 Phone: 952-926-4488 2 Aeroseal process uses DuctSeal sealant that is certified to meet requirements listed in UL 1381 standard -"Outline of investigation for Aerosol Duct Sealant" Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MQPNRJRQ. SmartSeal 4.3.2.8 (5261-22-66-128) 1 of 1 AEREISEAL Brackets Point Project, JK and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 4/27/2021 Overall Sealing BEFORE SERVICE 18.1 CFM of Leakage, equivalent to a 3.4 Square Inch Hole or 2.3% of the system capacity of 800.0 CFM AFTER SERVICE 10.4 CFM of Leakage, equivalent to a 2.0 Square Inch Hole or 1.3% of system capacity This corresponds to a 42% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. rsa��r �r�r-i is�rr4 a. a. � Zv�ti asr SO/sYC� y+Gsr! �GriY/FYI �CGrY�. DUCT SEALING REPORT AEROSEAL CASE ID: 5261 SYSTEM DESCRIPTION: HP205 SEAL DESCRIPTION: Salon Suply HARDWARE: HomeSeal Connect TECHNICIAN: Kevin C C 15 5 04 0 Sealing Time in hffinutes Select Mechanical Services 6219 Cambridge Street St. Louis Park, MN 55416 Phone: 952-926-4488 2 Aeroseal process uses DuctSeal sealant that is certified to meet requirements listed in UL 1381 standard -"Outline of investigation forAerosol Duct Sealant' Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code LZKNRJOG. SmartSeal 4.3.2.8 (5261-22-67-221) 1 of 1 AEREISEAL Brackets Point Project, JK and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 4/27/2021 Overall Sealing BEFORE SERVICE 20.8 CFM of Leakage, equivalent to a 3.9 Square Inch Hole or 2.6% of the system capacity of 800.0 CFM AFTER SERVICE 12.0 CFM of Leakage, equivalent to a 2.3 Square Inch Hole or 1.5% of system capacity This corresponds to a 42% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. rsa��r �r�r-i is�rr4 a. a. � Zv�ti asr SO/sYC� y+Gsr! �GriY/FYI �CGrY�. DUCT SEALING REPORT AEROSEAL CASE ID: 5261 SYSTEM DESCRIPTION: HP205 SEAL DESCRIPTION: Return HARDWARE: HomeSeal Connect TECHNICIAN: Kevin C 2F 20 � 10 LL 5 04 0 1 2 3 SeElirg Tins it h+lirLt4=3 Select Mechanical Services 6219 Cambridge Street St. Louis Park, MN 55416 Phone: 952-926-4488 Aeroseal process uses DuctSeal sealant that is certified to meet requirements listed in UL 1381 standard -"Outline of investigation forAerosol Duct Sealant' Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MQTNRJLX. SmartSeal 4.3.2.8 (5261-22-67-130) 1 of 1 AEREISEAL Brackets Point Project, JK and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 4/27/2021 Overall Sealing BEFORE SERVICE 36.7 CFM of Leakage, equivalent to a 6.9 Square Inch Hole or 4.6% of the system capacity of 800.0 CFM AFTER SERVICE 15.9 CFM of Leakage, equivalent to a 3.0 Square Inch Hole or 2.0% of system capacity This corresponds to a 57% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. rsa��r �r�r-i is�rr4 a. a. � Zv�ti asr SO/�YC� y+Gsr! �GriY/OYI ��rY�. DUCT SEALING REPORT AEROSEAL CASE ID: 5261 SYSTEM DESCRIPTION: HP205 SEAL DESCRIPTION: North Hall Supply HARDWARE: HomeSeal Connect TECHNICIAN: Kevin C a 40 30 20 LL 10 04 0 1 2 3 SeElirg Tins it h+lirl.ts3 Select Mechanical Services 6219 Cambridge Street St. Louis Park, MN 55416 Phone: 952-926-4488 Aeroseal process uses DuctSeal sealant that is certified to meet requirements listed in UL 1381 standard -"Outline of investigation for Aerosol Duct Sealant" Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MQJNRJPP. SmartSeal 4.3.2.8 (5261-22-67-131) 1 of 1 AER13SEAL Brackets Point Project, JK and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 4/27/2021 Overall Sealing BEFORE SERVICE 23.4 CFM of Leakage, equivalent to a 4.4 Square Inch Hole or 2.9% of the system capacity of 800.0 CFM AFTER SERVICE 13.7 CFM of Leakage, equivalent to a 2.6 Square Inch Hole or 1.7% of system capacity This corresponds to a 42% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. rsa��r �r�r-i is�rr4 a. a. � Zv�ti asr SO/sYC� y+Gsr! �GriY/FYI �CGrY�. DUCT SEALING REPORT AEROSEAL CASE ID: 5261 SYSTEM DESCRIPTION: HP201 SEAL DESCRIPTION: Supply HARDWARE: HomeSeal Connect TECHNICIAN: Kevin C 2F 29 � 19 LL 5 04 0 SeElirg Tins it h+lirLt4=3 Select Mechanical Services 6219 Cambridge Street St. Louis Park, MN 55416 Phone: 952-926-4488 2 Aeroseal process uses DuctSeal sealant that is certified to meet requirements listed in UL 1381 standard -"Outline of investigation forAerosol Duct Sealant' Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MPKNRJYZ. SmartSeal 4.3.2.8 (5261-22-68-133) 1 of 1 AEREISEAL Brackets Point Project, JK and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 4/27/2021 Overall Sealing BEFORE SERVICE 23.0 CFM of Leakage, equivalent to a 4.4 Square Inch Hole or 2.9% of the system capacity of 800.0 CFM AFTER SERVICE 13.3 CFM of Leakage, equivalent to a 2.5 Square Inch Hole or 1.7% of system capacity This corresponds to a 42% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. rsa��r �r�r-i is�rr4 a. a. � Zv�ti asr SO/sYC� y+Gsr! �GriY/FYI �CGrY�. DUCT SEALING REPORT AEROSEAL CASE ID: 5261 SYSTEM DESCRIPTION: HP201 SEAL DESCRIPTION: Return HARDWARE: HomeSeal Connect TECHNICIAN: Kevin C 2E 20 � 10 LL 5 04 0 Sealing Time in hffinutes Select Mechanical Services 6219 Cambridge Street St. Louis Park, MN 55416 Phone: 952-926-4488 2 Aeroseal process uses DuctSeal sealant that is certified to meet requirements listed in UL 1381 standard -"Outline of investigation forAerosol Duct Sealant' Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MPPNRJHY. SmartSeal 4.3.2.8 (5261-22-68-132) 1 of 1 AER13SEAL Brackets Point Project, JK and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 4/29/2021 Overall Sealing BEFORE SERVICE 61.6 CFM of Leakage, equivalent to a 11.6 Square Inch Hole or 10% of the system capacity of 600.0 CFM AFTER SERVICE 15.8 CFM of Leakage, equivalent to a 3.0 Square Inch Hole or 2.6% of system capacity This corresponds to a 74% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. rsa��r �r�r-i is�rr4 a. a. � Zv�ti asr SO/�YC� y+Gsr! �GriY/OYI ��rY�. DUCT SEALING REPORT AEROSEAL CASE ID: 5261 SYSTEM DESCRIPTION: HP138 SEAL DESCRIPTION: Supply HARDWARE: HomeSeal Connect TECHNICIAN: Kevin C 8{ 60 M CL n � 40 f5 v J LL 20 04 0 1 2 3 4 5 6 Sealing Time in Minutes Select Mechanical Services 6219 Cambridge Street St. Louis Park, MN 55416 Phone: 952-926-4488 Aeroseal process uses DuctSeal sealant that is certified to meet requirements listed in UL 1381 standard -"Outline of investigation for Aerosol Duct Sealant" Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MPJNRJZJ. SmartSeal 4.3.2.8 (5261-22-69-135) 1 of 1 AER13SEAL Brackets Point Project, X and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 4/29/2021 DUCT SEALING REPORT AEROSEAL CASE ID: 5261 SYSTEM DESCRIPTION: HP138 SEAL DESCRIPTION: Return HARDWARE: HomeSeal Connect TECHNICIAN: Kevin C BEFORE SERVICE 1 1 12' 94.7 CFM of Leakage, equivalent to a 17.9 Square Inch Hole or 100 16% of the system capacity of 600.0 CFM NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. Ci C 1 2 3 4 5 6 Sealing Time in Minutes 7 8 9 Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MPTNRJUM. SmartSeal 4.3.2.8 (5261-22-69-134) 1 of 1 � 80 AFTEF SERVICE 13.3 CFM of Leakage, equivalent to a 60 2.5 Square Inch Hole or J 2.2% of system capacity U 40 This corresponds to a 86% Reduction 2c. in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. Ci C 1 2 3 4 5 6 Sealing Time in Minutes 7 8 9 Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MPTNRJUM. SmartSeal 4.3.2.8 (5261-22-69-134) 1 of 1 AEREISEAL Brackets Point Project, JK and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 4/27/2021 Overall Sealing BEFORE SERVICE 160.3 CFM of Leakage, equivalent to a 30.3 Square Inch Hole or 13% of the system capacity of 1200.0 CFM AFTER SERVICE 17.5 CFM of Leakage, equivalent to a 3.3 Square Inch Hole or 1.5% of system capacity This corresponds to a 89% Reduction in Duct Leakage NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. rsa��r �r�r-i is�rr4 a. a. � Zv�ti asr SO/�YC� y+Gsr! �GriY/OYI ��rY�. DUCT SEALING REPORT AEROSEAL CASE ID: 5261 SYSTEM DESCRIPTION: HP132 SEAL DESCRIPTION: Supply HARDWARE: HomeSeal Connect TECHNICIAN: Kevin C 2{X 150 L: 100 50 2 4 6 a 1C. 12 Sealing Time in Minutes Select Mechanical Services 6219 Cambridge Street St. Louis Park, MN 55416 Phone: 952-926-4488 Aeroseal process uses DuctSeal sealant that is certified to meet requirements listed in UL 1381 standard -"Outline of investigation for Aerosol Duct Sealant" Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MMKNRJLL. SmartSeal 4.3.2.8 (5261-22-70-137) 1 of 1 AER13SEAL Brackets Point Project, X and Sons 1400 Brackets Point RD Orono, MN 55391 DATE: 4/27/2021 DUCT SEALING REPORT AEROSEAL CASE ID: 5261 SYSTEM DESCRIPTION: HP132 SEAL DESCRIPTION: Return HARDWARE: HomeSeal Connect TECHNICIAN: Kevin C BEFORE SERVICE 1 1 101 138.3 CFM of Leakage, equivalent to a 140 26.1 Square Inch Hole or 12% of the system capacity of 1200.0 CFM 120 AFTEF SERVICE Im 1°° 16.0 CFM of Leakage, equivalent to a 80 3.0 Square Inch Hole or J 1.3% of system capacityLL 60 U 40 This corresponds to a 88% Reduction in Duct Leakage 2c. NOTE: Duct leakage results are calculated in Cubic Feet per Minute (CFM) measured at a STANDARD OPERATING PRESSURE of 25 Pa. 0+ 0 2 4 6 8 Sealing Time in Minutes 10 12 Please provide Aeroseal feedback at http://bit.ly/2021aeroseal and reference code MMPNRJKR. SmartSeal 4.3.2.8 (5261-22-70-136) 1 of 1 From: negan@ci.orono.mn.us Sent: 08/12/2022 - 04:07 PM To: jason@selectmechanical.com,negan@ci.orono.mn.us CC: Subject: Inspection Report Individual, Inspection passed CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952) 249-4616 Inspection Report 1400 BRACKETTS POINT RD Permit Number: M20-000009 Site Address: 1400 BRACKETTS POINT RD, WAYZATA, MN 55391 Property Owner: BRACKETT POINT PROPERTY LLC Description: New home HVAC system Inspection Date: 08/12/2022 Inspection Type: Mechanical - Final Inspection Results: Permit Finaled Sincerely, ry Nicole Egan 952-249-4625 To schedule your inspections please call: (952) 249-4600 CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY!