HomeMy WebLinkAbout1992-05-21 On site Sewage Treatment Inspection ReportCITY OF ORONO . 0 6 Micipal Offices W )AI Post Office Som 66 Crystal flay, MN 55323.0066 � Municipal CN—BITE SEMAOt TIR"T>ifiiiiET ISfiSrEcTIon ampow Owner: IC 2-Ar%/k" l 1?Yan 42N-,, Address: � �f� 1�[' Permit #' o, Dates: S --F7 Contractors: 1.41.x. )5.0 City ordinsnce number 100 reWlres that each on-site sewage treatment system In Orono be inspected an a regular basis. The on-site same" treatment system at the above address has been impacted and appears to fall Into the category chocked below. (This is 154 an existing system I ) new construction) 'COD( SYSTEM" -A system which swats all the location, design, and construction standards of the current city Codas, and which is operating satisfactorily by treating and disposing of the entire current *eerie frput without dischar ens any pollute is into ground or surface waters. *CONFORMING SYSTEM -As tem which does not meet all the location, design, and construction standards of the current City codes but was Installed according to the code in effect at the time of Installation, and W ch is operating satisfactorily by treating and disposing of the entire current sewage input without discharyins any pollutants Into ground or surface waters. "MOM -CONFORMING SYSTEM" -A prohibited system; s system located within a designated 100 -year floodplain; any system which may or mey not meet all the location, design, and construction standards of the currant City Codes and which is falling for any reason; and any system with less than 3 feet of unsaturated soil or sad en betwethe distribution device and the limiting wail characteristics. (The limiting soil characteristic 14 hes or I 1 has not been identified at this time. If the limiting soil characteristic has not been Identified, this classification way be subject to revision.) TANK CMITIOII (5-10): Tank Inspection Indicates: SPUN t not needed at this time. 6 Sol do accumulation in tanks Indicates they should be papd out this year to help yrevent future problems. I Solids accumulation in tanks is at a critical level. tanks should be pumped out me soon as possible. 6 Syste� is discharging to the surface. Tanks must be pumped out within kE hours to eliminate surface discherse. P inspection risers ■lssins-tanks could not be inspected. Inspection risers (<" die. pipe) must be Installed in each tank at neat pumpout. If tanks have not been pumped out within the last three years, they should be pLmw out now. 0 inspection pipe Is located directly over tart bsffls (does not give accurate measurement of solids accumulation). If tanks hew not been pumped out withirh&w -.bind 00"1:1 ld irsp "cj Indicates: Qty Draln/lald Is dry, no surfacing evident. 2 Soma evldetwo o/ surfacing, not critical yet. 13 Drslnfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector Immediately. Repsirs mist be completed within 40 days. 14 Drainfleld extent and condition unknown. POTENTIAL FOR SYSTEM FAILLAK (daoards on soils.water tsbte.etc.): Lpi,11_ COKMENTSt to of Inspection /naptic syiVtl Inspector Mote: in the event that this inspection report Is used to satisfy the rswfromants for a Tortgage or other transfor of property, be advised that this report does not guarantee or certify that an existing systo-, will continue to funu.tion properly but Is merely an opin on of the adequacy of the system under current conditions based on the available information. This report must be kept on the praises with the system location and pumping records. WWTE COPY wnapacoors Fila YELLOW COPY. aim usowna