HomeMy WebLinkAboutM19-000160 - HVACFrom: oronoinspector@ci.orono.mn.us Sent: 06/19/2019 - 11:30 AM To: ccullinan@bdplumbers.com CC: Subject: Inspection Report Individual CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952)249-4616 Inspection Report 225 OLD CRYSTAL BAY RD S Permit Number: M19-000160 Site Address: 225 OLD CRYSTAL BAY RD S, LONG LAKE, MN 55356 Property Owner: JASON K PITTS Description: New Construction Inspection Date: 06/19/2019 Inspection Type: Mechanical -Air Test Inspection Results: Work Satisfactory: Proceed Inspection Status: General Comment 1. In floor heat. Pex tubing on 2 in rigid styrofoam insulation over 6 ml poly. Air test is holding. OK to continue. Jim H. Sincerely, Roger Peitso Building Official 952-249-4625 To schedule your inspections please call: (952) 249-4600 To schedule your inspection online Click Here CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY! From: oronoinspector@ci.orono.mn.us Sent: 07/29/2019 - 06:37 AM To: ccullinan@bdplumbers.com CC: Subject: Inspection Report Individual CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952)249-4616 Inspection Report 225 OLD CRYSTAL BAY RD S Permit Number: M19-000160 Site Address: 225 OLD CRYSTAL BAY RD S, LONG LAKE, MN 55356 Property Owner: JASON K PITTS Description: New Construction Inspection Date: 07/25/2019 Inspection Type: Mechanical - Rough In Inspection Results: Correct Work & Proceed Inspection Status: General Comment 1. Supplies, returns-ok finish bath fans. Jason R. 2. Bath fans/ insul.-ok 3. Kit. Hood-ok Sincerely, Roger Peitso Building Official 952-249-4625 To schedule your inspections please call: (952) 249-4600 To schedule your inspection online Click Here CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY! From: oronoinspector@ci.orono.mn.us Sent: 12/06/2019 - 01:34 PM To: ccullinan@bdplumbers.com CC: Subject: Inspection Report Individual CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952)249-4616 Inspection Report 225 OLD CRYSTAL BAY RD S Permit Number: M19-000160 Site Address: 225 OLD CRYSTAL BAY RD S, LONG LAKE, MN 55356 Property Owner: JASON K PITTS Description: New Construction Inspection Date: 12/06/2019 Inspection Type: Mechanical - Final Inspection Results: Correct Check at Building Final Inspection Status: General Comment 1. Gas line manometer is holding 2. Bath fans - ok 3. Provide make up air for kitchen hood. Jason R. 4. HRV - ERV balanced Sincerely, Roger Peitso Building Official 952-249-4625 To schedule your inspections please call: (952) 249-4600 To schedule your inspection online Click Here CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY! From: oronoinspector@ci.orono.mn.us Sent: 12/16/2019 - 02:07 PM To: ccullinan@bdplumbers.com CC: Subject: Inspection Report Individual Inspection Report 225 OLD CRYSTAL BAY RD S Permit Number: M19-000160 Site Address: 225 OLD CRYSTAL BAY RD S, LONG LAKE, MN 55356 Property Owner: JASON K PITTS Description: New Construction Inspection Date: 12/16/2019 Inspection Type: Mechanical - Final Inspection Results: Permit Finaled Inspection Status: General Comment CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952)249-4616 1. No makeup air needed per calculations provided from Table 501.4.1 of the Minnesota Mechanical Code. Photo uploaded. All work complete, permit finaled. Jim H. 2. Gas line manometer is holding 3. Bath fans - ok 4. HRV - ERV balanced Inspection Status: Complete 1. Provide make up air for kitchen hood. Jason R. Sincerely, i Roger Peitso Building Official 952-249-4625 To schedule your inspections please call: (952) 249-4600 To schedule your inspection online Click Here CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY! Old Cvy54,d Ba 12cxAo� S, own o Table 501.4.1 Procedure to Determine Makeup Air Quantify for Exhaust Appliances in mts Zb�g le One or multiple One or multiple One Multiple power vent or fan -assisted atmospherically appliances that are direct vent appliances and vented gas or oil atmospherically . appliances or no power vent or appliance or one vented gas or combustion direct vent solid fuel appli bid appliancesA appliances$ appliancec fuel esP 1. Use the Appropriate Column to Estimate House Infiltration a) pressure factor 015 0.09 0.06 0.03 (cfmlsf) b) conditioned floor area. (sf) H Ob (including unfinished basements) Estimated House Infiltration (cfm): 1 [lax lb] 2. Exhaust Capacity a) clothes dryer 135 135 135 135 b) 80% of largest exhaust rating L w (efin): (not applicable if recirculating system or if powered makeup air is electrically interlocked and matched to exhaust) c) 80% of next not largest exhaust applicable rating (cfm): (not applicable if recirculating system or if powered makeup air is electrically interlocked and matched to exhaust) Total Exhaust Capacity (cfm): _ D [2a+2b+2c] 3. Makeup Air Requirement a) Total Exhaust Capacity (from above) b) Estimated House Infiltration_ (from above) Makeup Air Quantity (cf n): loo [3a - 3b] (if value is negative,Cno�air is needed)