Loading...
HomeMy WebLinkAboutResolution 7362 LAND TYPE Abstract(A) DOC NUM 11201492 Certified, filed and/or recorded on May 18, 2023 11:59 AM Office of the County Recorder Hennepin County, Minnesota Amber Bougie, County Recorder Daniel Rogan, County Auditor and Treasurer Deputy 183 Pkg ID 2564962E Document Recording Fee $46.00 Document Total $46.00 This cover sheet is now a permanent part of the recorded document. -OAT CITY OF ORONO RESOLUTION OF THE CITY COUNCIL ikts NO. 7362 A RESOLUTION APPROVING VARIANCES FROM MUNICIPAL ZONING CODE SECTIONS 78-330,78-350,78-1279,& 78-1680 FILE NO.LA23-000008 WHEREAS,on March 7,2023,David Zweber with David Charlez Designs(hereinafter the "Applicant"),applied for variances from the City Code for the property addressed 1340 Vine Place and legally described as: Lot 1,together with Canal Street and Northerly '/2 of Canal vacated adoining said Lot 1, all of Lot 2, Southeasterly 1/2 of Lot 3,and that part of Lot 13,Block 17, Saga Hill Revised,Hennepin County,Minnesota described as follows: Commencing on Northerly line of said Lot 13 at a point 25 feet Southeasterly from Southeast corner of Lot 4,Block 17, Saga Hill,Revised,Hennepin County,Minnesota;thence Southerly and parallel with Westerly line of said Lot 13 a distance of 100 feet;thence Southeasterly and parallel with Northerly line of said Lot 13,to Easterly line thereof;thence Northeasterly to Northeast corner thereof;thence Northwesterly to beginning, together with Canal Street and Northerly V2 of Canal vacation adjoining above described premises, EXCEPT that part thereof described as follows;The Southeasterly %2 of Lot 3 and those parts of Lots 2 and 13 vacated Canal Street described as follows: Commencing on the Northerly line of said Lot 13,a distance of 100 feet;thence Southerly and parallel with the Northesterly line of said Lot 13 to the Southeasterly line thereof;thence Southeaster at right angles to the Southeasterly line of said Lot 13,a distance of 32.8 feet;thence Northerly deflecting to the left 132 degrees,35 minutes,a distance of 192.35 feet;thence deflecting to the right 40 degrees,a distance of 115 feet more or less to the Northeasterly line of said Lot 2;thence Northwesterly to the Northwesterly corner of said Lot 2; thence Southwesterly along the line dividing said Lots 2 and 3 to the Southwesterly corner of said Lot 2;thence Northwesterly along the line dividing said Lots 3 and 13 to the point of beginning. (hereinafter the"Property"); WHEREAS,the Applicant has applied to the City of Orono for a lot area variance from City Code Section 78-350 in order to construct a new single-family home; and WHEREAS,the Applicant has applied to the City of Orono for variances from average lakeshore setback and 75-foot lakeshore setback from City Code Section 78-1279 in order to construct a new single- family home; and WHEREAS,the Applicant has applied to the City of Orono for a variance from hardcover within the 75-foot lakeshore setback from City Code Section 78-1680 in order to construct a new single-family home; and 1 CITY OF ORONO 0 RESOLUTION OF THE CITY COUNCIL � A.Ittl)F NO. 7362 WHEREAS,the Applicant has applied to the City of Orono for a rear yard setback variance from City Code Section 78-330 in order to construct a new single-family home; and WHEREAS,on April 17,2023,after published and mailed notice in accordance with Minnesota Statutes and the City Code,the Planning Commission held a public hearing,at which time all persons desiring to be heard concerning this application were given the opportunity to speak thereon; and WHEREAS,on April 17,2023,the Planning Commission voted 6 to 0 in favor of a motion to recommend approval of the variances as applied; and WHEREAS,on May 8,2023 the City Council reviewed the application and the recommendations of the Planning Commission and City staff; and NOW, THEREFORE, BE IT RESOLVED that the City Council of Orono, Minnesota hereby approves the requested variances as described above based on one or more of the following findings of fact concerning the Property: FINDINGS OF FACT: 1. This application was reviewed as Zoning File#LA23-000008. The analysis contained within staff memos and the exhibits attached to the aforesaid memos, all minutes from the above mentioned meetings, and any and all other materials distributed at these meetings are hereby incorporated by reference. 2. The Property is located in the LR-1B One Family Lakeshore Residential Zoning District. 3. The Property contains 28,679 square feet in area and has a defined lot width of 227 feet at the 75- foot lakeshore setback and a lot width of 212 feet at the OHWL. 4. The Property is within Tier 1 and hardcover is limited to 25%according to the Stormwater Quality Overlay District. 5. Applicant has applied for the following variances: a. Lot Area b. Average Lakeshore Setback c. 75-foot Lakeshore Setback d. Hardcover within the 75-foot Lakeshore Setback e. Rear Yard Setback 2 -Wisv CITY OF ORONO RESOLUTION OF THE CITY COUNCIL �¢ �` NO. 7362 4x.EsH09-c" 6. In considering this application for variances, the Council has considered the advice and recommendation of the Planning Commission and the effect of the proposed variances upon the health, safety and welfare of the community, existing and anticipated traffic conditions, light and air,danger of fire,risk to the public safety,and the effect on values of property in the surrounding area. ANALYSIS: 1. "Variances shall only be permitted when they are in harmony with the general purposes and intent of the ordinance . . . ." The variances for the construction of a new single-family home on an existing,nonconforming foundation and substandard parcel are supported by practical difficulties. Much of the existing home is located within the 75-foot lakeshore setback, in front of the average lakeshore setback line and closer to the rear property line than the required rear yard setback. The proposal is to build a new home on top of the existing foundation and keep the existing lakeside decks. The lot currently contains a detached garage within the 75-foot lakeshore setback. The applicant is requesting to demolish this structure and construct an attached garage in a similar location. This slightly increases the hardcover within the 75-foot lakeshore setback by 155 square feet. The expanded massing in front of the ALS is largely due to a steeper roof pitch to allow for a better insulated roof that will be able to shed snow effectively. The existing home does not meet the required rear yard setback of 30 feet. The proposal is to rebuild a new home on the existing foundation and to expand the footprint for a front porch. The front porch expansion is in the same plane as the existing wall, however due to the angle of the lot a reduced rear yard setback is requested. The construction of a new home on top of an existing, nonconforming foundation is in harmony with the general intent of the Ordinance due to the practical difficulties of the substandard lot size,extreme setback requirements,and location of the existing structures.This criterion is met. 2. "Variances shall only be permitted . . . when the variances are consistent with the comprehensive plan." The variances resulting in a new single-family home constructed on a nonconforming foundation is consistent with the Comprehensive Plan. The applicant has identified necessary practical difficulties inherent to the land supporting their requests. The overall reduction in total hardcover bringing the lot into conformance is also consistent with the goals of the Comprehensive Plan. This criterion is met. 3. "Variances may be granted when the applicant for the variance establishes that there are practical difficulties in complying with the zoning ordinance. `Practical difficulties,' as used in connection with the granting of a variance,means that: a. The property owner in question proposes to use the property in a reasonable manner, however, the proposed use is not permitted by the official controls. The construction of a new single-family is a reasonable use of the property.The additional hardcover within the lake yard setback and massing requested is supported by practical 3 -,O ff} CITY OF ORONO 101C' RESOLUTION OF THE CITY COUNCIL A. NO. 7362 t4kEs H oo. difficulties due to the extreme setback requirements creating a very small building envelope that cannot support the construction of a new home. This criterion is met. b. The plight of the landowner is due to circumstances unique to his property not created by the landowner. The existing house was not built by the current owners. The lot is substandard in area and has extreme setback limitations due to the location within the inlet of a bay and orientation to the lake.The applicant is proposing to utilize the existing foundation to construct a new single-family home. The small lot size, extreme setback requirements, and placement of the existing structures on the lot are not the result of the current property owner's actions. c. The variance, if granted, will not alter the essential character of the locality." The proposed variances resulting in the construction of a larger home on an existing foundation are supported by practical difficulties and will not alter the character of the area. The additional massing in front of the average lakeshore setback line will not impact any site lines of the lake that are enjoyed by neighboring properties. The additional hardcover within the 75-foot lakeshore setback is offset by the overall reduction in hardcover on the site,bringing the lot into conformance. This criterion is met. 4. "Economic considerations alone do not constitute practical difficulties." Economic considerations have not been a factor in the variance approval determination. 5. "Practical difficulties also include but are not limited to inadequate access to direct sunlight for solar energy systems.Variances shall be granted for earth-sheltered construction as defined in Minn. Stat. § 216C.06, subd. 2, when in harmony with Orono City Code Chapter 78." This condition is not applicable. 6. "The board or the council may not permit as a variance any use that is not permitted under Orono City Code Chapter 78 for property in the zone where the affected person's land is located." This condition is not applicable,as a residential home is a permitted use in the LR-1B District. 7. "The board or council may permit as a variance the temporary use of a one-family dwelling as a two- family dwelling." This condition is not applicable. 8. "The special conditions applying to the structure or land in question are peculiar to such property or immediately adjoining property." The substandard lot size,unique lot shape,location on the inlet of a bay creating extreme setback requirements and the location of the existing structures on the lot are unique conditions to this specific property.This criterion is met. 4 CITY OF ORONO RESOLUTION OF THE CITY COUNCIL 111E:s.. -ES 1-10 NO. 7362 A 9. "The conditions do not apply generally to other land or structures in the district in which the land is located." While the surrounding properties are similar in size,the shape of the lot and location of the existing structures on the property are unique to the subject property.This criterion is met. 10. "The granting of the application is necessary for the preservation and enjoyment of a substantial property right of the applicant.".The existing home is in a nonconforming location.The proposal is to use the existing foundation to construct a new single-family home. The modifications to the design that increase massing are necessary due to the need for a steeper roof pitch.The overall hardcover will also be reduced on the site.This criterion is met. 11. "The granting of the proposed variance will not in any way impair health, safety,comfort or morals, or in any other respect be contrary to the intent of this chapter."Granting the requested variances will not adversely impact health,safety,comfort,or morals of the community.This criterion is met. 12. "The granting of such variance will not merely serve as a convenience to the applicant,but is necessary to alleviate demonstrable difficulty." The variances allow for the construction of a new home utilizing an existing foundation.The project will decrease the overall hardcover on the site bringing it into conformance.This criterion is met. CONCLUSIONS, ORDER AND CONDITIONS: Based upon one or more of the above findings,the Orono City Council hereby grants variances to Orono Municipal Zoning Code Sections 78-330, 78-350, 78-1279, and 78-1680 to allow the construction of a new single family home with exceptions to lot area, average lakeshore setback, 75-foot setback, hardcover within the 75-foot setback and rear yard setback subject to the following conditions: 1. Council approval is based on the entire record,above Findings. 2. The approved project shall conform to the attached site plan and building plans submitted by the Applicant and annotated by City staff(hereinafter the "Plans"), attached to this Resolution as Exhibits A& B. 3. Any amendments to the plans which are not in conformity with City codes may require further Planning Commission and City Council review. 4. Authorities granted by this resolution run with the Property not with the Applicants, but are permissive only and must be exercised by obtaining a building permit for the new construction and commencing construction of said project. A framing inspection must be completed within one year of the date of Council approval, or the variance will expire on that date (May 8,2024). 5 p,_ CITY OF ORONO _f RESOLUTION OF THE CITY COUNCIL 4�(�ioi, G1 NO. 7362 xEsHo� 5. Violation of or non-compliance with any of the terms and conditions of this resolution may result in the termination of any authority granted herein. ADOPTED by the Orono City Council on this 8th day of May,2023. ATTEST: OF CITY OF ORONO: Anna Carlson, City Clerk Dennis Walsh,Mayor 6 DRAWN BY DESCRIPTION PROJECT # PROJECT ISSUE RE-ISSUE BUILDER a18476 KENRICK AVE. SUITE #202 LAKEVILLE, MN 55044 TEL: 952.428.8200 EM: Dave@DavidCharlezDesigns.com D A V I D C H A R L E Z D E S I G N SD A V I D C H A R L E Z D E S I G N S Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2023. Do not replicate with out permission (952)-428-8200. David Charlez Design retains rights to all plans and detail shown. 2/16/2023 3:36:48 PM 01TitleMISC - Beduhn - CD Beduhn Remodel BUILDER BY HOMEOWNER1.12.2022GM 1340 Vine Place Orono, MN B E D U H N R E M O D E L 1340 VINE PLACE ORONO, MN REVISION SCHEDULE Number Date Issued by CDRev1 1.18.2023 GM CDRev2 1.24.2023 JCB CDRev3 2.2.2023 GM DRAWN BY DESCRIPTION PROJECT # PROJECT ISSUE RE-ISSUE BUILDER a18476 KENRICK AVE. SUITE #202 LAKEVILLE, MN 55044 TEL: 952.428.8200 EM: Dave@DavidCharlezDesigns.com D A V I D C H A R L E Z D E S I G N SD A V I D C H A R L E Z D E S I G N S Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2023. Do not replicate with out permission (952)-428-8200. David Charlez Design retains rights to all plans and detail shown. 2/16/2023 3:36:54 PM 02Title 2 MISC - Beduhn - CD Beduhn Remodel BUILDER BY HOMEOWNER1.12.2022GM 1340 Vine Place Orono, MN B E D U H N R E M O D E L 1340 VINE PLACE ORONO, MN REVISION SCHEDULE Number Date Issued by CDRev1 1.18.2023 GM CDRev2 1.24.2023 JCB CDRev3 2.2.2023 GM Existing First Floor0' - 0" Existing Second Floor 10' - 6 1/2" Roof18' - 7 5/8" Exst. First Floor Clg.8' - 4 1/2" Roof Peak 30' - 5 145/256" A B A B A B B B B B NEW ROOF NEW ROOF NEW ROOF Exst. Raised First Floor1' - 6" Exst. Raised First Floor Clg.9' - 10 1/2"8' - 1 1/8"8"8' - 4 1/2"1' - 6"8' - 4 1/2"5/4" x 8" TRIM 4/4" x 10" TRIM 5/4" x 8" TRIM EXST. FOUNDATION 5/4" x 8" TRIM AWNING ROOF w/ CABLES 5/4" x 10" TRIM 4/4" x 12" TRIM SITE VERIFY GRADE SLOPES. ACTUAL CONDITIONS MAY VARY FROM GRADE SLOPES SHOWN MATCH T.O. NEW GARAGE FOUNDATION w/ EXISTING T.O. FOUNDATION /(SEE 5 A12) New First Floor Clg.8' - 11 3/4"1' - 6 3/4"B B C C C B B B C 62616058 108 25 57 56 55 54 222324 21 53 51 50 49 48 47 46 C C C 5/4" x 8" TRIM B B BB B B B NEW ROOF NEW ROOF EXISTING BALCONY 5/4" x 8" TRIM 4/4" x 10" TRIM 5/4" x 8" TRIM 4/4" x 10" TRIM SITE VERIFY GRADE SLOPES. ACTUAL CONDITIONS MAY VARY FROM GRADE SLOPES SHOWN MATCH T.O. NEW GARAGE FOUNDATION w/ EXISTING T.O. FOUNDATION 5/4" x 8" TRIM 5/4" x 8" TRIM B 5/4" x 8" TRIM B A A B 218 06 0507 10 09 08 101 31 303233 11 1214 13 37 36 383940 103 16 15 104 4241434445 5/4" x 8" TRIM 4/4" x 10" TRIM C 36 EXISTING DECKEXISTING DECK DRAWN BY DESCRIPTION PROJECT # PROJECT ISSUE RE-ISSUE BUILDER a18476 KENRICK AVE. SUITE #202 LAKEVILLE, MN 55044 TEL: 952.428.8200 EM: Dave@DavidCharlezDesigns.com D A V I D C H A R L E Z D E S I G N SD A V I D C H A R L E Z D E S I G N S Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2023. Do not replicate with out permission (952)-428-8200. David Charlez Design retains rights to all plans and detail shown. 2/16/2023 3:37:01 PM 03Front & Rear Elevations MISC - Beduhn - CD Beduhn Remodel BUILDER BY HOMEOWNER1.12.2022GM 1340 Vine Place Orono, MN FOUNDATION WALL HEIGHTS ARE SUBJECT TO CHANGE DUE TO GRADE AND SITE CONDITIONS. ALL FOUNDATION WALL HEIGHTS MUST BE VERIFIED ON SITE BY THE CONTRACTOR AND SITE SURVEYOR PRIOR TO CONSTRUCTION. FOUNDATION CONTRACTOR WILL STEP FOUNDATION WALLS AS NECESSARY TO MAINTAIN PROPER FROST PROTECTION (42" BELOW GRADE) IN ACCORDANCE TO CURRENT MINNESOTA CODE, REGULATIONS, AND ZONING. FOUNDATION WALLS DISCLOSURE: TYPICAL EXTERIOR MATERIALS ASPHALT SHINGLES W/ NATURAL SHADOW ARCHITECTURAL GRADE COMPOSITE PANEL SMOOTH w/ BATTEN STRIPS @ 16" O.C. PER ELEVATION 4" EXPOSURE COMPOSITE SIDING PER ELEVATION COMPOSITE PANELING SMOOTH PER ELEVATION 199 METAL SIDING CORNERS PER ELEVATION 1X8 ON 1X18 COMPOSITE FASCIA PER ELEVATION COMPOSITE VENTED SOFFITS PER ELEVATION MARVIN ELEVATE WINDOWS w/ BLACK EXTERIORS PER ELEVATION HOUSE WRAP AND/OR TAR PAPER IN PROPER FORM ON ENTIRE EXTERIOR B C A SEE "TYPICAL EXTERIOR MATERIALS" FOR ALL CLADDING SHOWN SEE FINAL PAGE FOR SQUARE FOOTAGE CALCULATIONS METAL FASCIAS AND ROOFS HAVE THE TENDENCY TO OIL CAN UNDER CERTAIN WEATHER CONDITIONS. CONSULT CONTRACTOR FOR METAL GAUGE THICKNESS OPTIONS TO REDUCE WEATHER RELATED CONCERNS (BUBBLING, WARPING, ETC.) GENERAL CONTRACTOR TO ENSURE THAT ALL ROOF PENETRATIONS (VENT PIPES, EXHAUST FANS, FURNACE/AC PIPES, ETC) ARE PLACED IN OBSCURE LOCATIONS ON ROOF TO MINIMIZE THE SIGHT OF PENETRATIONS FROM MAIN ARCHITECTURAL VIEWS OF HOME. elevation notes: 1/4" = 1'-0" 1Front Elevation 1/4" = 1'-0" 2Rear Elevation IMPORTANT REMODEL NOTE: VERIFY ALL HEIGHTS AND SIZES OF EXISTING WINDOWS, DOORS, AND ROOF. VERIFY FLOOR AND WALL HEIGHTS IN THE EFFECTED AREA PRIOR TO ORDERING MATERIALS OR STARTING CONSTRUCTION ALL DIMENSIONS LINES TO BE TO CENTERLINE OF STUDS TO FACE OF SHEATHING ALL OVERALL DIMENSION LINES TO BE FACE OF STUD TO FACE OF SHEATHING VERIFY ALL HEIGHTS AND SIZES OF EXISTING CONSTRUCTION MATERIALS: WALL STUDS, FLOOR JOISTS, SUB FLOOR, AND ROOF TRUSSES PRIOR TO ORDERING MATERIALS OR STARTING CONSTRUCTION FIELD VERIFY OVERHANGS AND ROOF PITCH PRIOR TO ORDERING ROOF TRUSSES OR STARTING CONSTRUCTION ALL MODIFICATIONS AND NEW LOADS APPLIED TO THE EXISTING ROOF STRUCTURE WILL BE VERIFIED BY AN ENGINEER WHO WILL PROVIDED DRAWING AND SPECIFICS STRUCTURAL ENGINEERS SIGNATURE IS NEEDED BEFORE PLANS CAN BE SUBMITTED TO CITY OF ORONO FOR APPROVAL. ENGINEER WILL VERIFY THAT ALL MODIFICATIONS TO THE PROJECT MEET STATE AND LOCAL GOVERNMENT REQUIREMENTS REVISION SCHEDULE Number Date Issued by CDRev1 1.18.2023 GM CDRev2 1.24.2023 JCB CDRev3 2.2.2023 GM A B NEW ROOF B EXISTING FOUNDATION 5/4" x 8" TRIM 4/4" x 10" TRIM 5/4" x 8" TRIM SITE VERIFY GRADE SLOPES. ACTUAL CONDITIONS MAY VARY FROM GRADE SLOPES SHOWN EXST. BALCONYAWNING ROOF /(SEE 5A12) BC 03 0402 01 2829 27 633534 102 B B B BB A NEW ROOF NEW ROOFB 5/4" x 8" TRIM 8" / 12" SLOPED ROOF5/4" x 8" TRIM 4/4" x 10" TRIM C C C 181719 20 52 59 26 C C C C 5/4" x 8" TRIM 8" / 12"8" / 12"8" / 12"8" / 12"3 1/2" / 12"8" / 12"8" / 12"3 1/2" / 12"3 1/2" / 12"8" / 12" 8" / 12" 8" / 12"8" / 12"ROOF RIDGE VENT ROOF RIDGE VENTROOF RIDGE VENT12"36"36"12"12" 24"24"24"36" 36"18"24"6"6"36"12"36"12"36"36"30"12" FLAT ROOF @ 1/4" SLOPE 19' - 0"36"ROOF RIDGE VENT ROOF RIDGE VENTNOTE: ALL EXISTING ROOFS TO BE REMOVED. ROOF PLAN INDICATES ALL NEW ROOF TRUSSES 28' - 10" 8"/12" SLOPE /(SEE 5 A12) TYPICAL AWNING w/ CABLES /(SEE 5 A12) TYPICAL AWNING w/ CABLES12"DRAWN BY DESCRIPTION PROJECT # PROJECT ISSUE RE-ISSUE BUILDER a18476 KENRICK AVE. SUITE #202 LAKEVILLE, MN 55044 TEL: 952.428.8200 EM: Dave@DavidCharlezDesigns.com D A V I D C H A R L E Z D E S I G N SD A V I D C H A R L E Z D E S I G N S Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2023. Do not replicate with out permission (952)-428-8200. David Charlez Design retains rights to all plans and detail shown. 2/16/2023 3:37:07 PM 04Left & Right Elevations MISC - Beduhn - CD Beduhn Remodel BUILDER BY HOMEOWNER1.12.2022GM 1340 Vine Place Orono, MN TYPICAL EXTERIOR MATERIALS ASPHALT SHINGLES W/ NATURAL SHADOW ARCHITECTURAL GRADE COMPOSITE PANEL SMOOTH w/ BATTEN STRIPS @ 16" O.C. PER ELEVATION 4" EXPOSURE COMPOSITE SIDING PER ELEVATION COMPOSITE PANELING SMOOTH PER ELEVATION 199 METAL SIDING CORNERS PER ELEVATION 1X8 ON 1X18 COMPOSITE FASCIA PER ELEVATION COMPOSITE VENTED SOFFITS PER ELEVATION MARVIN ELEVATE WINDOWS w/ BLACK EXTERIORS PER ELEVATION HOUSE WRAP AND/OR TAR PAPER IN PROPER FORM ON ENTIRE EXTERIOR B C A FOUNDATION WALL HEIGHTS ARE SUBJECT TO CHANGE DUE TO GRADE AND SITE CONDITIONS. ALL FOUNDATION WALL HEIGHTS MUST BE VERIFIED ON SITE BY THE CONTRACTOR AND SITE SURVEYOR PRIOR TO CONSTRUCTION. FOUNDATION CONTRACTOR WILL STEP FOUNDATION WALLS AS NECESSARY TO MAINTAIN PROPER FROST PROTECTION (42" BELOW GRADE) IN ACCORDANCE TO CURRENT MINNESOTA CODE, REGULATIONS, AND ZONING. FOUNDATION WALLS DISCLOSURE: SEE "TYPICAL EXTERIOR MATERIALS" FOR ALL CLADDING SHOWN SEE FINAL PAGE FOR SQUARE FOOTAGE CALCULATIONS METAL FASCIAS AND ROOFS HAVE THE TENDENCY TO OIL CAN UNDER CERTAIN WEATHER CONDITIONS. CONSULT CONTRACTOR FOR METAL GAUGE THICKNESS OPTIONS TO REDUCE WEATHER RELATED CONCERNS (BUBBLING, WARPING, ETC.) GENERAL CONTRACTOR TO ENSURE THAT ALL ROOF PENETRATIONS (VENT PIPES, EXHAUST FANS, FURNACE/AC PIPES, ETC) ARE PLACED IN OBSCURE LOCATIONS ON ROOF TO MINIMIZE THE SIGHT OF PENETRATIONS FROM MAIN ARCHITECTURAL VIEWS OF HOME. elevation notes: 1/4" = 1'-0" 1Left Elevation 1/4" = 1'-0" 2Right Elevation 1/8" = 1'-0" 3 Roof Plan ENGINEERED ROOF TRUSSES PER MFG. SPEC. MANUFACTURE WILL PROVIDE ALL ENGINEERING DRAWING AND SPECIFICS OVERHANG DIMENSIONS ARE TO FACE OF FRAMING ICE AND WATER ALL ADJOINING ROOFS TRUSS MANUFACTURER TO VERIFY ALL ENERGY HEELS SHOWN TO ENSURE FINAL EAVE FRAMING DOES NOT CONFLICT WITH FINISHED EXTERIOR WINDOW TRIM AS SHOWN ON ELEVATIONS. METAL FASCIAS AND ROOFS HAVE THE TENDENCY TO OIL CAN UNDER CERTAIN WEATHER CONDITIONS. CONSULT CONTRACTOR FOR METAL GAUGE THICKNESS OPTIONS TO REDUCE WEATHER RELATED CONCERNS (BUBBLING, WARPING, ETC.) GENERAL CONTRACTOR TO ENSURE THAT ALL ROOF PENETRATIONS (VENT PIPES, EXHAUST FANS, FURNACE/AC PIPES, ETC) ARE PLACED IN OBSCURE LOCATIONS ON ROOF TO MINIMIZE THE SIGHT OF PENETRATIONS FROM MAIN ARCHITECTURAL VIEWS OF HOME. roof plan notes: IMPORTANT REMODEL NOTE: VERIFY ALL HEIGHTS AND SIZES OF EXISTING WINDOWS, DOORS, AND ROOF. VERIFY FLOOR AND WALL HEIGHTS IN THE EFFECTED AREA PRIOR TO ORDERING MATERIALS OR STARTING CONSTRUCTION ALL DIMENSIONS LINES TO BE TO CENTERLINE OF STUDS TO FACE OF SHEATHING ALL OVERALL DIMENSION LINES TO BE FACE OF STUD TO FACE OF SHEATHING VERIFY ALL HEIGHTS AND SIZES OF EXISTING CONSTRUCTION MATERIALS: WALL STUDS, FLOOR JOISTS, SUB FLOOR, AND ROOF TRUSSES PRIOR TO ORDERING MATERIALS OR STARTING CONSTRUCTION FIELD VERIFY OVERHANGS AND ROOF PITCH PRIOR TO ORDERING ROOF TRUSSES OR STARTING CONSTRUCTION ALL MODIFICATIONS AND NEW LOADS APPLIED TO THE EXISTING ROOF STRUCTURE WILL BE VERIFIED BY AN ENGINEER WHO WILL PROVIDED DRAWING AND SPECIFICS STRUCTURAL ENGINEERS SIGNATURE IS NEEDED BEFORE PLANS CAN BE SUBMITTED TO CITY OF ORONO FOR APPROVAL. ENGINEER WILL VERIFY THAT ALL MODIFICATIONS TO THE PROJECT MEET STATE AND LOCAL GOVERNMENT REQUIREMENTS REVISION SCHEDULE Number Date Issued by CDRev1 1.18.2023 GM CDRev2 1.24.2023 JCB CDRev3 2.2.2023 GM 2 13 3 15 1 15 2 15 3 13 1 14 3 14 2 14 1 13 36' - 0"38' - 6"34' - 0"1' - 6"8' - 0"10' - 0"8' - 0"7' - 0"7' - 0"2' - 6"33' - 6 1/2"3' - 0"7' - 5 1/2"8' - 0"12' - 6"10' - 0"34' - 0"1' - 6"2' - 6"29' - 0"11' - 0"110' - 0" 110' - 0"3' - 0"- UNEXCAVATED - - NEW GARAGE FOUNDATION - 1' - 10 1/2" MASONRY OP'NG 9' - 3"2' - 9" MASONRY OP'NG 18' - 3"1' - 10 1/2" 10 1/2" M.O. 3' - 3"14' - 3" MASONRY OP'NG 9' - 3"6' - 4 1/2" - EXISTING CRAWL SPACE - - EXISTING CRAWL SPACE - -new crawl space to match existing - UNEXCAVATED MATCH T.O. NEW FOUNDATION TO EXISTING T.O. FOUNDATION MATCH T.O. NEW FOUNDATION TO EXISTING T.O. FOUNDATION TYPICAL SLAB CONSTRUCTION: 4" CONCRETE SLAB PITCHED TOWARDS OVERHEAD DOOR OVER POLY/VAPOR BARRIER OVER SAND BED GRANULAR FILL GARAGE FND WALL: 3'-6"x8" POURED CONCRETE FOUNDATION ON 20"x8" CONCRETE FOOTING REBAR PER CODE NEW PORCH FND WALL: 3'-6"x8" POURED CONCRETE FOUNDATION ON 20"x8" CONCRETE FOOTING REBAR PER CODE NEW STAIRCASE FND WALL: MATCH EXISTING WALL HEIGHTx8" POURED CONCRETE FND. ON 20"x8" CONCRETE FOOTING REBAR PER CODE Exst. Exst. Exst. Exst. Exst. New New New Exst.New Exst. Exst.9' - 6"1' - 7 3/4"10' - 7"1 1/2"11' - 1 3/4"5' - 8 3/4"18' - 9 1/4" 1' - 8 3/4"10' - 2 1/4"12' - 7" NEW PAD 36"x36"x12" NEW PAD 36"x36"x12" 1 12 3 12 NOTE: PROVIDE EXISTING CRAWL SPACE & FOUNDATION AREA TO BE SEALED WITH VAPOR BARRIER NOTE: PROVIDE EXISTING CRAWL SPACE & FOUNDATION WITH SEALED WITH VAPOR BARRIER 2" SLAB LEDGE 2" SLAB LEDGE NEW STAIRCASE LOCATION. VERIFY EXISTING FLOOR JOISTS & SPECIFY NEW BEAMS/HEADERS IF NECESSARY BUILT-UP FLOOR AREA ON T.O. NEW FLR SYSTEMEXISTING DECK JOISTS & FOOTINGS EXISTING DECK JOISTS & FOOTINGS 42' - 6"42' - 6"NOTE: PROVIDE NEW CRAWL SPACE & FOUNDATION WITH SEALED WITH VAPOR BARRIER NOTE: VERIFY EXISTING SLAB LEDGE UPON REMOVAL OF SLAB TO RECIEVE NEW JOISTS. MFG TO SPEC NEW HANGERS/ LEDGERBOARD WHERE NECESSARY NEW PAD 36"x36"x12" NEW PAD 36"x36"x12"2x10 JOISTS @ 16" O.C. 2x10 JOISTS @ 16" O.C. 2x10 JOISTS @ 16" O.C. 2x10 JOISTS @ 16" O.C.BEAM DROPPED PER MFG. SPEC.NEW FND WALLS: MATCH EXISTING HGT "x 8" POURED CONCRETE FOUNDATION ON 20"x8" CONCRETE FOOTING. PROVIDE 2" JOIST LEDGE AS NECESSARY REBAR PER CODE 1/4" = 1'-0" 1Lower Level DRAWN BY DESCRIPTION PROJECT # PROJECT ISSUE RE-ISSUE BUILDER a18476 KENRICK AVE. SUITE #202 LAKEVILLE, MN 55044 TEL: 952.428.8200 EM: Dave@DavidCharlezDesigns.com D A V I D C H A R L E Z D E S I G N SD A V I D C H A R L E Z D E S I G N S Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2023. Do not replicate with out permission (952)-428-8200. David Charlez Design retains rights to all plans and detail shown. 2/16/2023 3:37:11 PM 05Lower Level MISC - Beduhn - CD Beduhn Remodel BUILDER BY HOMEOWNER1.12.2022GM 1340 Vine Place Orono, MN DIMENSIONS ARE FROM FACE OF CONCRETE & FACE OF SHEATHING TO CENTER OF STUD. EXISTING FLOOR SYSTEM & CRAWL SPACES TO REMAIN AS EXISTING LOWER LEVEL NOTES: IMPORTANT REMODEL NOTE: VERIFY ALL HEIGHTS AND SIZES OF EXISTING WINDOWS, DOORS, AND ROOF. VERIFY FLOOR AND WALL HEIGHTS IN THE EFFECTED AREA PRIOR TO ORDERING MATERIALS OR STARTING CONSTRUCTION ALL DIMENSIONS LINES TO BE TO CENTERLINE OF STUDS TO FACE OF SHEATHING ALL OVERALL DIMENSION LINES TO BE FACE OF STUD TO FACE OF SHEATHING VERIFY ALL HEIGHTS AND SIZES OF EXISTING CONSTRUCTION MATERIALS: WALL STUDS, FLOOR JOISTS, SUB FLOOR, AND ROOF TRUSSES PRIOR TO ORDERING MATERIALS OR STARTING CONSTRUCTION FIELD VERIFY OVERHANGS AND ROOF PITCH PRIOR TO ORDERING ROOF TRUSSES OR STARTING CONSTRUCTION ALL MODIFICATIONS AND NEW LOADS APPLIED TO THE EXISTING ROOF STRUCTURE WILL BE VERIFIED BY AN ENGINEER WHO WILL PROVIDED DRAWING AND SPECIFICS STRUCTURAL ENGINEERS SIGNATURE IS NEEDED BEFORE PLANS CAN BE SUBMITTED TO CITY OF ORONO FOR APPROVAL. ENGINEER WILL VERIFY THAT ALL MODIFICATIONS TO THE PROJECT MEET STATE AND LOCAL GOVERNMENT REQUIREMENTS REVISION SCHEDULE Number Date Issued by CDRev1 1.18.2023 GM CDRev2 1.24.2023 JCB CDRev3 2.2.2023 GM CDRev4 2.16.2023 LMC DEMO EXISTING STAIRCASE DEMO EXISTING KITCHEN CABINETS, APPLIANCES, ETC.REMOVE ALL EXISTING WINDOWS & MODIFY EXISTING EXTERIOR WALLS FOR NEW WINDOW/DOOR PLACEMENTSREMOVE ALL EXISTING WINDOWS & MODIFY EXISTING EXTERIOR WALLS FOR NEW WINDOW/DOOR PLACEMENTS REMOVE ALL EXISTING WALLS & REPLACE WITH NEW AS SHOWNREMOVE EXISTING GARAGE STRUCTURE & REPLACE WITH ATTACHED GARAGE AS SHOWN EXISTING COLUMN BEARING EXISTING DROPPED BEAMS EXISTING DROPPED BEAM REMOVE ALL EXISTING WINDOWS & MODIFY EXISTING EXTERIOR WALLS FOR NEW WINDOW/DOOR PLACEMENTS REMOVE ALL EXISTING WINDOWS & MODIFY EXISTING EXTERIOR WALLS FOR NEW WINDOW/DOOR PLACEMENTS NEW MAIN LEVEL NEW GARAGE EXISTING COLUMN BEARINGEXISTING OP'NGEXISTING OP'NGDRAWN BY DESCRIPTION PROJECT # PROJECT ISSUE RE-ISSUE BUILDER a18476 KENRICK AVE. SUITE #202 LAKEVILLE, MN 55044 TEL: 952.428.8200 EM: Dave@DavidCharlezDesigns.com D A V I D C H A R L E Z D E S I G N SD A V I D C H A R L E Z D E S I G N S Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2023. Do not replicate with out permission (952)-428-8200. David Charlez Design retains rights to all plans and detail shown. 2/16/2023 3:37:16 PM 06Main Level Demo Plan MISC - Beduhn - CD Beduhn Remodel BUILDER BY HOMEOWNER1.12.2022GM 1340 Vine Place Orono, MN 1/4" = 1'-0" 1 Main Level Demo Plan REVISION SCHEDULE Number Date Issued by CDRev1 1.18.2023 GM CDRev2 1.24.2023 JCB CDRev3 2.2.2023 GM 36' - 0"38' - 6"34' - 0"1' - 6"11' - 0"29' - 0"2' - 6"33' - 6 1/2"3' - 0"7' - 5 1/2"8' - 0"22' - 6"34' - 0"1' - 6"3' - 2 1/2"15' - 7"5' - 8 1/2"4' - 6"5' - 6"5' - 6"3' - 8 3/4"3' - 8 3/4"4' - 0"4' - 0"6' - 6"6' - 0"7' - 9 1/2"2' - 2 1/2"2' - 0"4' - 6"4' - 6"3' - 0"9' - 0"9' - 0"2' - 0"4' - 0 1/2"2' - 11 1/2"3' - 0"8' - 5 1/2"3' - 0"7' - 0"7' - 0"8' - 0"10' - 0"8' - 0"5' - 0"5' - 0"7' - 6 5/8"17' - 11 3/8"10' - 6"3' - 0"14' - 0"9' - 0"4' - 2"4' - 0 1/2"4' - 3 1/2"2' - 6"16' - 0"4' - 6"4' - 6"6' - 6" 110' - 0"4' - 10 1/4"4' - 10"14' - 7 1/4"2' - 1 1/2" 2' - 2 1/2" 7' - 11"4' - 5 1/2"2' - 3 1/4"7' - 10 1/4"12' - 9 1/4"2' - 4 1/2"3' - 3 1/4"5' - 0 1/4"6' - 3"4' - 2 3/4"5' - 8 3/4"7' - 8"4' - 5 1/2"12' - 7 1/4"4' - 2"9' - 2 3/4"GUEST RM LAKE BATH EXST. MECH CARPET FLOOR W.I.C. TILE FLR MUD ROOM TILE FLOOR LAUNDRY TILE FLOOR FAMILY ROOM WOOD FLOOR FOYER WOOD FLOOR DINING WOOD FLOOR KITCHEN WOOD FLOOR GREAT ROOM WOOD FLOOR POCKET OFFICE WOOD FLOOR GARAGE CONCRETE FLOOR ZERO ENTRYFIRE DOOR20 MIN. RATEDNEW FURN.90" FULL HGT. CAB.WSHR w/FLOORDRAIND SINK UPPER CABINETS54" VANITYTILE FLR36"x60" TILESHOWERFAN SD/CO SD/CO FAN SHELVING BY OTHERS7'-6" BENCH w/ LOCKERS48" DROPZONE9'-0" x 8'-0" OVERHEAD DOOR 18'-0" x 8'-0" OVERHEAD DOOR 9' - 0"4' - 0"4' - 0"5' - 0"48" RANGE HOOD VENTUPPER CABINETS60" FULL HGT. CABINET48" REF.24" D.W.30" SINKCOAT HOOKSEXST. STEPSEXST. STEPSEXST. OP'NGSTAIRS WOOD TREADS & RISERS EXISTING DECK WOOD STEPS 60" LINEAR GAS FIREPLACE PER MFG. SPEC. EXISTING DECK 6X6 POST 6X6 POST GARAGE WALLS: INSULATE WALLS & CEILINGS 5/8" TYPE-X GYP. BD. & FINISH TAPE ON ALL INTERIOR GARAGE WALLS & CEILINGS NOTE: SLOPE CONCRETE SLAB TOWARDS OVERHEAD DOOR & FOR ZERO ENTRY INTO HOUSE FLOOR OVER GARAGE: -HEAT DUCT & SEWER WRAPPED & FOAMED -HOLD HEAT DUCT & SEWER TIGHT TO SUBFLOOR -BLOWN INSULATION (R-49) 2 13 3 15 1 15 2 15 3 13 1 14 3 14 2 14 1 13 FRONT PORCH STAMPED CONCRETE OPT. PINE T&G CLG.STEP DOWN1 12 3 12LINE OF EXISTING FLOOR HEIGHT CHANGERAISED FLOOR CONSTRUCTION: 3/4" SUBFLOOR 2X6 TRD. JOISTS @ 16" O.C. BUILT-IN DESK EXISTING COLUMN BEARING EXISTING DROPPED BEAMS EXISTING DROPPED BEAM 9' x 5' SERVING ISLAND TYPICAL SLAB CONSTRUCTION: 4" CONCRETE SLAB PITCHED TOWARDS OVERHEADR DOOR OVER POLY/VAPOR BARRIER OVER SAND BED GRANULAR FILL INDICATES NEW WALLS INDICATES EXISTING WALLS (UNDISTURBED OR MODIFIED) SHELVING OPEN UNDER STAIRS NOTE: VERIFY COUNTERTOP HGT. BEFORE ORDERING WINDOWS UPPER CABINETS EXISTING COLUMN BEARINGEXISTING OPENINGRAILINGS PER CODE9'-0" x 8'-0" OVERHEAD DOOR EXST. WELL HEAD NOTE: VERIFY EXISTING WELL HEAD DIMENSIONS TO DETERMINE HOUSING BOX SIZING DIMENSIONS 6' - 2 1/4"7' - 7 1/2"5' - 11"2' - 4 1/4"42' - 6"EQEQ 03 04 01 02 050806090710 1011021113 15 103 16 104 105 17 18 19 106107 20 21 22 23 24 25 108 2627 12 14 2' - 2 1/2"4' - 9 1/2"x32"80"109x32"80" 110 x60"80" 111 x36"80"112x36"80"114x36"80"113x36"80"115x36"80" 116 x36"80" 117 x36"80" 118 8'-11 3/4" CLG. HGT. 110' - 0"40' - 0" 1/4" = 1'-0" 1Main Level DRAWN BY DESCRIPTION PROJECT # PROJECT ISSUE RE-ISSUE BUILDER a18476 KENRICK AVE. SUITE #202 LAKEVILLE, MN 55044 TEL: 952.428.8200 EM: Dave@DavidCharlezDesigns.com D A V I D C H A R L E Z D E S I G N SD A V I D C H A R L E Z D E S I G N S Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2023. Do not replicate with out permission (952)-428-8200. David Charlez Design retains rights to all plans and detail shown. 2/16/2023 3:37:21 PM 07Main Level MISC - Beduhn - CD Beduhn Remodel BUILDER BY HOMEOWNER1.12.2022GM 1340 Vine Place Orono, MN DIMENSIONS ARE FROM FACE OF SHEATHING TO CENTER OF STUD FLOOR TRUSSES ARE CALLED OUT AT 19.2" O.C. FLOOR SYSTEM DESIGNER VERIFY SPACING AND ADJUST AS ALLOWED BY SPANS CEILING HEIGHT @ 8'-4 1/2" UNLESS NOTED (VERIFY EXISTING) T.O. WINDOW FRAMES SET @ HEIGHT NOTED ON WINDOW SCHEDULE MAIN LEVEL NOTES: IMPORTANT REMODEL NOTE: VERIFY ALL HEIGHTS AND SIZES OF EXISTING WINDOWS, DOORS, AND ROOF. VERIFY FLOOR AND WALL HEIGHTS IN THE EFFECTED AREA PRIOR TO ORDERING MATERIALS OR STARTING CONSTRUCTION ALL DIMENSIONS LINES TO BE TO CENTERLINE OF STUDS TO FACE OF SHEATHING ALL OVERALL DIMENSION LINES TO BE FACE OF STUD TO FACE OF SHEATHING VERIFY ALL HEIGHTS AND SIZES OF EXISTING CONSTRUCTION MATERIALS: WALL STUDS, FLOOR JOISTS, SUB FLOOR, AND ROOF TRUSSES PRIOR TO ORDERING MATERIALS OR STARTING CONSTRUCTION FIELD VERIFY OVERHANGS AND ROOF PITCH PRIOR TO ORDERING ROOF TRUSSES OR STARTING CONSTRUCTION ALL MODIFICATIONS AND NEW LOADS APPLIED TO THE EXISTING ROOF STRUCTURE WILL BE VERIFIED BY AN ENGINEER WHO WILL PROVIDED DRAWING AND SPECIFICS STRUCTURAL ENGINEERS SIGNATURE IS NEEDED BEFORE PLANS CAN BE SUBMITTED TO CITY OF ORONO FOR APPROVAL. ENGINEER WILL VERIFY THAT ALL MODIFICATIONS TO THE PROJECT MEET STATE AND LOCAL GOVERNMENT REQUIREMENTS REVISION SCHEDULE Number Date Issued by CDRev1 1.18.2023 GM CDRev2 1.24.2023 JCB CDRev3 2.2.2023 GM 2 13 3 15 1 15 2 15 3 13 1 14 3 14 2 14 1 13 15' - 6"12' - 6"1' - 0" 6X6 STRUCTURAL POSTS (ENG. TO VERIFY)BEAM FLUSHED PER MFG. SPEC. GUEST RM BATH EXST. MECH W.I.C. MUD ROOM LAUNDRYFAMILY ROOM FOYER KITCHEN GREAT ROOM POCKET OFFICE GARAGE STAIRS EXISTING DECK EXISTING SIDE DECK FRONT PORCH EXISTING BEARING WALL STEP DOWNEXISTING DROPPED BEAM EXISTING DROPPED BEAMEXST. DROPPED BEAMEXISTING DROPPED BEAMEXISTING DROPPED BEAM EXISTING DROPPED BEAM EXISTING DROPPED BEAM EXISTING DROPPED BEAM EXISTING DROPPED BEAM NEW FLOOR JOISTS (MATCH EXISTING)EXISTING DROPPED BEAMEXISTING DROPPED BEAMEXISTING DROPPED BEAMBEAM FLUSHED PER MFG. SPEC. SIZE TO ALLOW FOR HVAC BEAM FLUSHED PER MFG. SPEC. SIZE TO ALLOW FOR HVAC ROOF TRUSSES PER MFG. SPEC.24" FLOOR TRUSSES @ 19.2" O.C.24" FLOOR TRUSSES @ 19.2" O.C.BEAM FLUSHED PER MFG. SPEC.BEAM FLUSHED PER MFG. SPEC.BEAM FLUSHED PER MFG. SPEC.BEAM FLUSHED PER MFG. SPEC.SIZE TO ALLOW FOR HVACOPEN TO ABOVE DINING OPEN TO ABOVE NEW BEAM PER MFG. SPEC.ROOF TRUSSES PER MFG.GARAGE DOOR HDR. PER MFG. SPEC.GARAGE DOOR HDR. PER MFG. SPEC.NEW WINDOW HDR. PER MFG. SPEC.NEW WINDOW HDR. PER MFG. SPEC.NEW DOOR HDR. PER MFG. SPEC. NEW WINDOW HDR. PER MFG. SPEC. NEW WINDOW HDR. PER MFG. SPEC. NEW WINDOW HDR. PER MFG. SPEC.NEW WINDOW HDR. PER MFG. SPEC.NEW WINDOW HDR. PER MFG. SPEC.NEW DOOR HDR. PER MFG. SPEC. NEW DOOR HDR. PER MFG. SPEC. NEW WINDOW HDR. PER MFG. SPEC. NEW DOOR HDR. PER MFG. SPEC. NEW WINDOW HDR. PER MFG. SPEC. NEW WINDOW HDR. PER MFG. SPEC. NEW DOOR HDR. PER MFG. SPEC.NEW DOOR HDR. PER MFG. SPEC.NEW WINDOW HDR. PER MFG. SPEC. 1 12 3 12EXISTING 2X8 JOISTSEXISTING 2X8 JOISTSEXISTING 2X8 JOISTSEXISTING 2X8 JOISTSBEAM FLUSHEDPER MFG. SPEC.LANDING BEAM PER MFG. LANDING BEAM PER MFG. 19' - 0"11' - 0"BEAM w/ CANOPY HANDERS PER MFG. SPEC.BEAM w/ CANOPY HANDERS PER MFG. SPEC.BRG. PT. FROM ABOVE18" FLOOR TRUSSES @ 19.2" O.C.18" FLOOR TRUSSES @ 19.2" O.C.18" FLOOR TRUSSES @ 19.2" O.C.18" FLOOR TRUSSES @ 19.2" O.C.NEW WINDOW HDR. PER MFG. SPEC.NEW WINDOW HDR. PER MFG. SPEC.GIRDER TRUSS PER MFG. SPEC.ROOF TRUSSES @ 24" O.C.DRAWN BY DESCRIPTION PROJECT # PROJECT ISSUE RE-ISSUE BUILDER a18476 KENRICK AVE. SUITE #202 LAKEVILLE, MN 55044 TEL: 952.428.8200 EM: Dave@DavidCharlezDesigns.com D A V I D C H A R L E Z D E S I G N SD A V I D C H A R L E Z D E S I G N S Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2023. Do not replicate with out permission (952)-428-8200. David Charlez Design retains rights to all plans and detail shown. 2/16/2023 3:37:26 PM 08Main Level Structural MISC - Beduhn - CD Beduhn Remodel BUILDER BY HOMEOWNER1.12.2022GM 1340 Vine Place Orono, MN 1/4" = 1'-0" 1Main Level Structural NOT AN OFFICAL STRUCTURAL PLAN. ALL BEAMS, HEADERS, AND GIRDER TRUSSES SHOWN MUST BE SPECIFIED AND DETERMINED BY A LICENSED STRUCTURAL ENGINEER. REFER TO STRUCTURAL DOCUMENTS PROVIDED BY ENGINEER FOR FINAL LOCATIONS, SIZES, AND SPECS. ROOF/FLOOR GIRDER TRUSSES SHOWN ARE APPROXIMATE LOCATIONS. NOT ALL NECESSARY GIRDERS MAY BE SHOWN. TRUSS MANUFACTURER TO DETERMINE FINAL LOCATIONS OF GIRDER TRUSSES. SIZE BEAMS/HEADERS TO ALLOW FOR HVAC RUNS THROUGHOUT ENTIRETY OF HOME. GRAYED OUT FRAMED WALLS ARE 2X6 BEARING WALLS UNLESS NOTED FLOOR TRUSSES ARE CALLED OUT AT 19.2” O.C. FLOOR SYSTEM DESIGNER TO VERIFY SPACING AND ADJUST AS ALLOWED BY SPANS CEILING HEIGHT @ 8'-4 1/2" UNLESS NOTED T.O. WINDOW FRAMES SET @ HEIGHT NOTED ON WINDOW SCHEDULE structural notes:IMPORTANT REMODEL NOTE: VERIFY ALL HEIGHTS AND SIZES OF EXISTING WINDOWS, DOORS, AND ROOF. VERIFY FLOOR AND WALL HEIGHTS IN THE EFFECTED AREA PRIOR TO ORDERING MATERIALS OR STARTING CONSTRUCTION ALL DIMENSIONS LINES TO BE TO CENTERLINE OF STUDS TO FACE OF SHEATHING ALL OVERALL DIMENSION LINES TO BE FACE OF STUD TO FACE OF SHEATHING VERIFY ALL HEIGHTS AND SIZES OF EXISTING CONSTRUCTION MATERIALS: WALL STUDS, FLOOR JOISTS, SUB FLOOR, AND ROOF TRUSSES PRIOR TO ORDERING MATERIALS OR STARTING CONSTRUCTION FIELD VERIFY OVERHANGS AND ROOF PITCH PRIOR TO ORDERING ROOF TRUSSES OR STARTING CONSTRUCTION ALL MODIFICATIONS AND NEW LOADS APPLIED TO THE EXISTING ROOF STRUCTURE WILL BE VERIFIED BY AN ENGINEER WHO WILL PROVIDED DRAWING AND SPECIFICS STRUCTURAL ENGINEERS SIGNATURE IS NEEDED BEFORE PLANS CAN BE SUBMITTED TO CITY OF ORONO FOR APPROVAL. ENGINEER WILL VERIFY THAT ALL MODIFICATIONS TO THE PROJECT MEET STATE AND LOCAL GOVERNMENT REQUIREMENTS REVISION SCHEDULE Number Date Issued by CDRev1 1.18.2023 GM CDRev2 1.24.2023 JCB CDRev3 2.2.2023 GM EXISTING BALCONY AREA DECREASE WIDTH AS SHOWN REMOVE EXISTING ROOF TRUSSES OVER MAIN LEVEL. REPLACE WITH NEW UPPER LEVEL AS SHOWN DRAWN BY DESCRIPTION PROJECT # PROJECT ISSUE RE-ISSUE BUILDER a18476 KENRICK AVE. SUITE #202 LAKEVILLE, MN 55044 TEL: 952.428.8200 EM: Dave@DavidCharlezDesigns.com D A V I D C H A R L E Z D E S I G N SD A V I D C H A R L E Z D E S I G N S Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2023. Do not replicate with out permission (952)-428-8200. David Charlez Design retains rights to all plans and detail shown. 2/16/2023 3:37:30 PM 09Upper Level Demo Plan MISC - Beduhn - CD Beduhn Remodel BUILDER BY HOMEOWNER1.12.2022GM 1340 Vine Place Orono, MN 1/4" = 1'-0" 1 Upper Level Demo Plan REVISION SCHEDULE Number Date Issued by CDRev1 1.18.2023 GM CDRev2 1.24.2023 JCB CDRev3 2.2.2023 GM 36' - 6 1/2"7' - 5 1/2"8' - 0"22' - 6"34' - 0"11' - 0"29' - 0"4' - 0 1/2"2' - 11 1/2"3' - 0"7' - 6 5/8"9' - 5 3/8"8' - 6"10' - 6"3' - 0"7' - 0"7' - 0"11' - 8 3/4"14' - 11 1/4"17' - 10"6' - 0"5' - 0" 17' - 0"19' - 0"72' - 6" 25' - 6"11' - 0 1/2"3' - 8 3/4"3' - 8 3/4"4' - 0"4' - 0"6' - 6"13' - 9 1/2"2' - 2 1/2"6' - 6"5' - 6"5' - 0"6' - 0"6' - 0"5' - 0" 108' - 6"5' - 6"6"5' - 0"4' - 6"5' - 8 1/2"15' - 7"3' - 2 1/2"9' - 3 1/2"2' - 2 1/2"4' - 6"4' - 6"17' - 0"4' - 6"7' - 0"3' - 0"4' - 0"7' - 6"12' - 0"9' - 6"8' - 1"5' - 10"5' - 6 1/2"8' - 6 1/2"9' - 11 1/2" 9' - 10 1/2"5' - 8" 41 1/2"41 1/2"1' - 0 1/2"4' - 0"7' - 4"12' - 4 1/4"2' - 4 1/2"4' - 4 1/2"2' - 4 1/2"2' - 4 3/4"4' - 4 1/2"2' - 4 1/2"12' - 4 1/4"7' - 0 1/4"6' - 10 1/2"SD/CO SD/CO SMOKE DET. SMOKE DET. SMOKE DET. SMOKE DET. OWNER'S SUITE OPEN TO KITCHEN BELOW OPEN TO DINING BELOW EXST. LOFT BDRM #2 BDRM #3 BDRM #4 BATH BONUS ROOMEXST. BALCONY CARPET FLOORING COMPOSITE DECKING CABLE RAILING CABLE RAILING CABLE RAILING WOOD FLOORING CARPET FLOORING 18" LIN.54" VANITYFAN 36"x60" TILE SHOWER BI-PASS DOOR R&S 4' - 1 3/4" CARPET FLOORING R&S 5' - 8 3/4"4' - 1 3/4" CARPET FLOORING STAIRS WOOD TREADS & RISERSCABLE RAILINGCABLE RAILINGFAN78" VANITY36"x60" TILETUB/SHWRBEV. REF. WET BAR CARPET FLOORING VAULTED CEILINGS2X6 WALL2X6 PLMG WALL2X6 WALL2X6 PLMG WALL2X6 WALLFLOOR OVER GARAGE: -HEAT DUCT & SEWER WRAPPED & FOAMED -HOLD HEAT DUCT & SEWER TIGHT TO SUBFLOOR -BLOWN INSULATION (R-49) 10' - 6 1/2" EXISTING UPPER LEVEL FLOOR ELEVATION 2 13 3 15 1 15 2 15 3 13 1 14 3 14 2 14 EXISTING FLOOR SYSTEMNEW FLOOR SYSTEM1 13 NEW LOFT WOOD FLOORING 1 12 3 1219 3/4"EXISTING BALCONY AREA DECREASE WIDTH AS SHOWN EXISTING EXPOSED BEAM @ MAIN LEVEL CLG. STORAGE SPACE STORAGE SPACE STORAGE SPACE INDICATES NEW WALLS INDICATES EXISTING WALLS (UNDISTURBED OR MODIFIED) TILE FLOOR OPEN BELOW SHELVING LINEN SHELVING4' - 3"2' - 4 1/2"16'-0" DRY BAR LINE OF VAULTLINE OF VAULT 16"16" NEW 8'-6" VANITY NEW 36"x60" FREE STANDING TUBNEW LINEN NEW LINEN NEW 84"x42" TILE SHOWER w/ CORNER BENCH10' - 7 3/4"EXISTING CLOSET 10' - 8"6' - 0 3/4" WALL SHOULD STACK w/ KITCHEN/MECH. WALL BELOW EQEQ 28 29 21830313233 34 35 3637 38 39 40 41 42 43 44 45 464748 495051 52 5354555658 59 606162 63 40' - 0"11' - 6"57x30"80"201x36"80"202x30"80" 203x30"80"204x60"80" 205 x30"80" 208 x48"80" 207x30"80"206x72"80" 210 x30"80"211x72"80" 209 x30"80"212x30"80" 213 x36"80"214x36"80" 215 x36"80" 216 x36"80" 217 BATH TILE 40' - 0"108' - 6" OWNER'S BATH TILE FLOOR 3' - 6"36 1/4" = 1'-0" 1Upper Level DRAWN BY DESCRIPTION PROJECT # PROJECT ISSUE RE-ISSUE BUILDER a18476 KENRICK AVE. SUITE #202 LAKEVILLE, MN 55044 TEL: 952.428.8200 EM: Dave@DavidCharlezDesigns.com D A V I D C H A R L E Z D E S I G N SD A V I D C H A R L E Z D E S I G N S Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2023. Do not replicate with out permission (952)-428-8200. David Charlez Design retains rights to all plans and detail shown. 2/16/2023 3:37:36 PM 10Upper Level MISC - Beduhn - CD Beduhn Remodel BUILDER BY HOMEOWNER1.12.2022GM 1340 Vine Place Orono, MN DIMENSIONS ARE FROM FACE OF SHEATHING TO CENTER OF STUD ROOF TRUSSES ARE CALLED OUT @ 24” O.C. ROOF SYSTEM DESIGNER TO VERIFY SPACING AND ADJUST AS ALLOWED BY SPANS TRUSS MANUFACTURER TO VERIFY ALL ENERGY HEELS SHOWN TO ENSURE FINAL EAVE FRAMING DOES NOT CONFLICT WITH FINISHED EXTERIOR WINDOW TRIM AS SHOWN ON ELEVATIONS. CEILING HEIGHT @ 8'-1 1/8" UNLESS NOTED (VERIFY EXISTING) T.O. WINDOW FRAMES SET @ HEIGHT NOTED ON WINDOW SCHEDULE upper LEVEL NOTES: IMPORTANT REMODEL NOTE: VERIFY ALL HEIGHTS AND SIZES OF EXISTING WINDOWS, DOORS, AND ROOF. VERIFY FLOOR AND WALL HEIGHTS IN THE EFFECTED AREA PRIOR TO ORDERING MATERIALS OR STARTING CONSTRUCTION ALL DIMENSIONS LINES TO BE TO CENTERLINE OF STUDS TO FACE OF SHEATHING ALL OVERALL DIMENSION LINES TO BE FACE OF STUD TO FACE OF SHEATHING VERIFY ALL HEIGHTS AND SIZES OF EXISTING CONSTRUCTION MATERIALS: WALL STUDS, FLOOR JOISTS, SUB FLOOR, AND ROOF TRUSSES PRIOR TO ORDERING MATERIALS OR STARTING CONSTRUCTION FIELD VERIFY OVERHANGS AND ROOF PITCH PRIOR TO ORDERING ROOF TRUSSES OR STARTING CONSTRUCTION ALL MODIFICATIONS AND NEW LOADS APPLIED TO THE EXISTING ROOF STRUCTURE WILL BE VERIFIED BY AN ENGINEER WHO WILL PROVIDED DRAWING AND SPECIFICS STRUCTURAL ENGINEERS SIGNATURE IS NEEDED BEFORE PLANS CAN BE SUBMITTED TO CITY OF ORONO FOR APPROVAL. ENGINEER WILL VERIFY THAT ALL MODIFICATIONS TO THE PROJECT MEET STATE AND LOCAL GOVERNMENT REQUIREMENTS REVISION SCHEDULE Number Date Issued by CDRev1 1.18.2023 GM CDRev2 1.24.2023 JCB CDRev3 2.2.2023 GM OWNER'S SUITE OPEN TO KITCHEN BELOW OPEN TO DINING BELOW EXST. CLOSET OWNER'S BATH LOFT BDRM #2 BDRM #3 BDRM #4 BATH BONUS ROOM BALCONY ROOF TRUSSES @ 24" O.C.ROOF TRUSSES @ 24" O.C. ROOF TRUSSES @ 24" O.C.ROOF TRUSSES @ 24" O.C.ROOF TRUSSES @ 24" O.C.ROOF TRUSSES @ 24" O.C.DOOR HDR. PER MFG. SPEC. WINDOW HDR. PER MFG. SPEC.WINDOW HDR. PER MFG. SPEC.WINDOW HDR. PER MFG. SPEC. WINDOW HDR. PER MFG. SPEC. WINDOW HDR. PER MFG. SPEC. WINDOW HDR. PER MFG. SPEC. WINDOW HDR. PER MFG. SPEC. WINDOW HDR. PER MFG. SPEC. WINDOW HDR. PER MFG. SPEC. WINDOW HDR. PER MFG. SPEC.WINDOW HDR. PER MFG. SPEC.WINDOW HDR. PER MFG. SPEC. WINDOW HDR. PER MFG. SPEC. WINDOW HDR. PER MFG. SPEC. WINDOW HDR. PER MFG. SPEC.WINDOW HDR. PER MFG. SPEC.WINDOW HDR. PER MFG. SPEC.2 13 3 15 1 15 2 15 3 13 1 14 3 14 2 14 1 13 1 12 3 12 ATTIC ACCESS ROOF TRUSSES @ 24" O.C.ROOF TRUSSES @ 24" O.C.PROPOSED GIRDER TRUSS PER MFG. SPEC.PROPOSED GIRDER TRUSS PER MFG. SPEC.PROPOSED GIRDER TRUSS PER MFG. SPEC.PROPOSED GIRDER TRUSS PER MFG. SPEC. BATH W.I.C. VAULT LINE VAULT LINEWINDOW HDR. PER MFG. SPEC.WINDOW HDR. PER MFG. SPEC. DRAWN BY DESCRIPTION PROJECT # PROJECT ISSUE RE-ISSUE BUILDER a18476 KENRICK AVE. SUITE #202 LAKEVILLE, MN 55044 TEL: 952.428.8200 EM: Dave@DavidCharlezDesigns.com D A V I D C H A R L E Z D E S I G N SD A V I D C H A R L E Z D E S I G N S Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2023. Do not replicate with out permission (952)-428-8200. David Charlez Design retains rights to all plans and detail shown. 2/16/2023 3:37:40 PM 11Upper Level Structural MISC - Beduhn - CD Beduhn Remodel BUILDER BY HOMEOWNER1.12.2022GM 1340 Vine Place Orono, MN 1/4" = 1'-0" 1Upper Level Structural NOT AN OFFICAL STRUCTURAL PLAN. ALL BEAMS, HEADERS, AND GIRDER TRUSSES SHOWN MUST BE SPECIFIED AND DETERMINED BY A LICENSED STRUCTURAL ENGINEER. REFER TO STRUCTURAL DOCUMENTS PROVIDED BY ENGINEER FOR FINAL LOCATIONS, SIZES, AND SPECS. ROOF/FLOOR GIRDER TRUSSES SHOWN ARE APPROXIMATE LOCATIONS. NOT ALL NECESSARY GIRDERS MAY BE SHOWN. TRUSS MANUFACTURER TO DETERMINE FINAL LOCATIONS OF GIRDER TRUSSES. SIZE BEAMS/HEADERS TO ALLOW FOR HVAC RUNS THROUGHOUT ENTIRETY OF HOME. GRAYED OUT FRAMED WALLS ARE 2X6 BEARING WALLS UNLESS NOTED ROOF TRUSSES ARE CALLED OUT @ 24” O.C. ROOF SYSTEM DESIGNER TO VERIFY SPACING AND ADJUST AS ALLOWED BY SPANS TRUSS MANUFACTURER TO VERIFY ALL ENERGY HEELS SHOWN TO ENSURE FINAL EAVE FRAMING DOES NOT CONFLICT WITH FINISHED EXTERIOR WINDOW TRIM AS SHOWN ON ELEVATIONS. CEILING HEIGHT @ 8'-1 1/8" UNLESS NOTED (VERIFY EXISTING) T.O. WINDOW FRAMES SET @ HEIGHT NOTED ON WINDOW SCHEDULE structural notes: IMPORTANT REMODEL NOTE: VERIFY ALL HEIGHTS AND SIZES OF EXISTING WINDOWS, DOORS, AND ROOF. VERIFY FLOOR AND WALL HEIGHTS IN THE EFFECTED AREA PRIOR TO ORDERING MATERIALS OR STARTING CONSTRUCTION ALL DIMENSIONS LINES TO BE TO CENTERLINE OF STUDS TO FACE OF SHEATHING ALL OVERALL DIMENSION LINES TO BE FACE OF STUD TO FACE OF SHEATHING VERIFY ALL HEIGHTS AND SIZES OF EXISTING CONSTRUCTION MATERIALS: WALL STUDS, FLOOR JOISTS, SUB FLOOR, AND ROOF TRUSSES PRIOR TO ORDERING MATERIALS OR STARTING CONSTRUCTION FIELD VERIFY OVERHANGS AND ROOF PITCH PRIOR TO ORDERING ROOF TRUSSES OR STARTING CONSTRUCTION ALL MODIFICATIONS AND NEW LOADS APPLIED TO THE EXISTING ROOF STRUCTURE WILL BE VERIFIED BY AN ENGINEER WHO WILL PROVIDED DRAWING AND SPECIFICS STRUCTURAL ENGINEERS SIGNATURE IS NEEDED BEFORE PLANS CAN BE SUBMITTED TO CITY OF ORONO FOR APPROVAL. ENGINEER WILL VERIFY THAT ALL MODIFICATIONS TO THE PROJECT MEET STATE AND LOCAL GOVERNMENT REQUIREMENTS REVISION SCHEDULE Number Date Issued by CDRev1 1.18.2023 GM CDRev2 1.24.2023 JCB CDRev3 2.2.2023 GM Existing Upper Level Clg. Hgt.8' - 1 1/8"8"Existing Main Level Clg. Hgt.8' - 4 1/2"8"EXST. 2X8 FLOOR SYSTEM EXST. 2X8 FLOOR SYSTEMEXST. BALCONYNew Energy Heel26 1/4"8" 12" 3' - 0" NEW ROOF TRUSSES PER MFG. SPEC. EXISTING DECK EXISTING CRAWL SPACE Exst. 12 2 New Overhang 3' - 0" 8" 12"New Energy Heel26 1/4"2X 6 T R U S S T A I L S 2X 4 L O O K O U T S Sub Fascia17 1/2"EXST. WALLMETAL DRIP EDGE 4/4" x 8" TRIM 3/4" BACKING 4/4" x 12" FASICA 17-1/2" x 1-1/4" SUB FASICA CO M P O S I T E V E N T E D S O F F I T S TYPICAL EAVE CONSTRUCTION: ARCHITECTURAL GRADE ASPHALT SHINGLES #15FELT & ICE & WATER SHIELD (6'-0") 1/2" OSB SHEATHING w/STEEL CLIPS TRUSSES @ 24" O.C. (PER MFG. SPEC.) BAFFLES w/1" AIR SPACE 2X4 LOOKOUTS 17-1/2" x 1-1/4" RIM BOARD SUB FASCIA 4/4" x 8" FASCIA ON 4/4" x 12" COMPOSITE FASCIA COMPOSITE VENTED SOFFITS NEW CRAWL SPACE TO MATCH EXISITNGNew Energy Heel30 1/4"3' - 0" 8" 12" ROOF, CEILING & EAVE CONSTRUCTION: WALL CONSTRUCTION: FOUNDATION WALL & BASEMENT SLAB CONSTRUCTION: MAIN LEVEL CONSTRUCTION: UPPER LEVEL CONSTRUCTION: ARCHITECTURAL GRADE ASPHALT SHINGLES #15FELT & ICE & WATER SHIELD (6'-0") 1/2" OSB SHEATHING w/STEEL CLIPS TRUSSES @ 24" O.C. (PER MFG. SPEC.) BAFFLES w/1" AIR SPACE 2X4 LOOKOUTS 17-1/2" x 1-1/4" RIM BOARD SUB FASCIA 4/4" x 8" FASCIA ON 4/4" x 12" COMPOSITE FASCIA COMPOSITE VENTED SOFFITS R-50 BLOWN INSULATION POLY VAPOR BARRIER 5/8" GYP. BRD. CEILING 3/4" T&G PLYWOOD SUBFLOOR GLUED & SCREWED 18" FLOOR TRUSSES @ 19.2" O.C. (FLOOR SYSTEM DESIGNER TO VERIFY SIZE & SPACING BASED ON SPANS) 5/8" GYP. BRD. ON CEILING SPRAY INSULATE RIMS (R-21) SIDING PER ELEVATION HOUSE WRAP (WRAP WINDOWS PER MFG. SPEC.) 1/2" OSB SHEATHING 2X6 STUDS @16" O.C. DBL. TOP PLATE R-21 WALL INSULATION 4 MIL POLY VAPOR BARRIER 1/2" GYP. BRD. 2X6 SOLE PLATE ALL DETAILS TO CONFORM W/ ENERGY CODE AS EXISTING AS EXISTING8' - 1 1/8"1' - 6 3/4"8' - 11 3/4"NEW 2x10 JOISTS TO MATCH EXISTING New 3' - 0" 2' - 9 1/4"2 3/4" METAL DRIP EDGE 5/4" x 8" COMP. FASCIA 3/4" BACKING 15-1/8" x 1-1/4" RIM BOARD SUB FASCIA 15 1/8"4/4" x 10" COMP. FASCIA 2X4 BLOCKING CANOPY HANGERS PER ENG. SPEC.BEAM PERMFG. SPEC.2X4 LOOKOUTS 2X4 LOOKOUTS EPDM RUBBER MEMBRANE 3/4" PLYWOOD (PITCHED @ 1/4" SLOPE MIN.) WEDGE BLOCK COMPOSITE VENTED SOFFIT TYPICAL FLAT EAVE w/ CABLES: EPDM RUBBER MEMBRANE (EXTEND MEMBRANE 12"-18" UP/DN ABUDDING WALLS/ROOFS) 3/4" PLYWOOD SHEATHING w/ WEDGE BLOCK 2X4 LOOKOUTS @ 24" O.C. BEAM FLUSHED PER MFG. SPEC. 5/4" x 8" COMPOSITE FASICA w/ METAL DRIP EDGE 3/4" BACKING 4/4" x 10" COMPOSITE FASCIA 15-1/8" x 1-1/4" RIM BOARD SUB FASCIA 2X4 BLOCKING COMPOSITE VENTED SOFFITS FLOOR TRUSSES PER PLAN 1' - 6 3/4"12" 2X4 LOOKOUTS 2X4 LOOKOUTS 16 7/8"METAL DRIP EDGE 5/4" x 8" COMP. FASCIA 3/4" BACKING 4/4" x 12" COMP. FASCIA 16-7/8" x 1-1/4" RIM BOARD SUB FASCIA EPDM RUBBER MEMBRANE3/4" PLYWOOD SHEATHING @ 1/4" SLOPE MIN.Energy Heel11 3/8"COMPOSITE VENTED SOFFITS FLAT EAVE @ BONUS ROOM: EPDM RUBBER MEMBRANE (EXTEND MEMBRANE 12"-18" UP/DN ABUDDING WALLS/ROOFS) 3/4" PLYWOOD SHEATHING w/ WEDGE BLOCK 2X4 LOOKOUTS @ 24" O.C. 5/4" x 8" COMPOSITE FASICA w/ METAL DRIP EDGE 3/4" BACKING 4/4" x 12" COMPOSITE FASCIA 16-7/8" x 1-1/4" RIM BOARD SUB FASCIA COMPOSITE VENTED SOFFITS DRAWN BY DESCRIPTION PROJECT # PROJECT ISSUE RE-ISSUE BUILDER a18476 KENRICK AVE. SUITE #202 LAKEVILLE, MN 55044 TEL: 952.428.8200 EM: Dave@DavidCharlezDesigns.com D A V I D C H A R L E Z D E S I G N SD A V I D C H A R L E Z D E S I G N S Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2023. Do not replicate with out permission (952)-428-8200. David Charlez Design retains rights to all plans and detail shown. 2/16/2023 3:37:45 PM 12Cross Sections MISC - Beduhn - CD Beduhn Remodel BUILDER BY HOMEOWNER1.12.2022GM 1340 Vine Place Orono, MN 1/2" = 1'-0" 1Typical Wall Section 1 1" = 1'-0" 2Detail - Typical Eave 1/2" = 1'-0" 3Typical Wall Section 2 1 1/2" = 1'-0" 5 Detail - Typical Eave w/ Hangers 1 1/2" = 1'-0" 6 Detail - Flat Eave @ Bonus Rm IMPORTANT REMODEL NOTE: VERIFY ALL HEIGHTS AND SIZES OF EXISTING WINDOWS, DOORS, AND ROOF. VERIFY FLOOR AND WALL HEIGHTS IN THE EFFECTED AREA PRIOR TO ORDERING MATERIALS OR STARTING CONSTRUCTION ALL DIMENSIONS LINES TO BE TO CENTERLINE OF STUDS TO FACE OF SHEATHING ALL OVERALL DIMENSION LINES TO BE FACE OF STUD TO FACE OF SHEATHING VERIFY ALL HEIGHTS AND SIZES OF EXISTING CONSTRUCTION MATERIALS: WALL STUDS, FLOOR JOISTS, SUB FLOOR, AND ROOF TRUSSES PRIOR TO ORDERING MATERIALS OR STARTING CONSTRUCTION FIELD VERIFY OVERHANGS AND ROOF PITCH PRIOR TO ORDERING ROOF TRUSSES OR STARTING CONSTRUCTION ALL MODIFICATIONS AND NEW LOADS APPLIED TO THE EXISTING ROOF STRUCTURE WILL BE VERIFIED BY AN ENGINEER WHO WILL PROVIDED DRAWING AND SPECIFICS STRUCTURAL ENGINEERS SIGNATURE IS NEEDED BEFORE PLANS CAN BE SUBMITTED TO CITY OF ORONO FOR APPROVAL. ENGINEER WILL VERIFY THAT ALL MODIFICATIONS TO THE PROJECT MEET STATE AND LOCAL GOVERNMENT REQUIREMENTS REVISION SCHEDULE Number Date Issued by CDRev1 1.18.2023 GM CDRev2 1.24.2023 JCB CDRev3 2.2.2023 GM CDRev4 2.16.2023 LMC Existing First Floor0' - 0" Existing Second Floor 10' - 6 1/2" Roof 18' - 7 5/8"8' - 1 1/8"1' - 6 3/4"8' - 11 3/4"8' - 1 1/8"1' - 6 3/4"8' - 11 3/4"10"3' - 6"12 5Heel18 1/4"3/4" SUBFLOOR 18" FLOOR TRUSSES @ 19.2" O.C.3/4" SUBFLOOR 24" FLOOR TRUSSES @ 19.2" O.C. EXISTING 2X10 FLOOR SYSTEM EXISTING CRAWL SPACE Exst.NewNew New 3/4" SUBFLOOR 2X6 TRD. JOISTS @ 16" O.C. NEW ROOF TRUSSES PER MFG. SPEC.2' - 0" 8" 12" 8" 12"4' - 0 1/2"Ceiling Height Varies w/ Vault2' - 0 3/4"T.O. Foundation to B.O. Trusses8' - 11 1/4"ZERO ENTRY GARAGE SLAB INTO HOUSE T.O. GARAGE FOUNDATION TO MATCH EXISTING GARAGE Heel18 5/16"NEW ROOF TRUSSES PER MFG. SPEC. BATHLAUNDRYFAMILY ROOM GARAGE NEW 2x10 JOIST FLOOR SYSTEM TO MATCH EXISTING BDRM #2 BDRM #3 BONUS ROOM NOTE: NEW EXISTING CRAWL SPACE & FOUNDATION AREA TO BE SEALED WITH VAPOR BARRIER. MATCH EXISTING HEIGHT GRADE MUST BE MINIMUM OF 6" BELOW TOP OF FOUNDATION WALL B.O. FOOTING @ MIN. 42" BELOW GRADE TYPICAL SLAB CONSTRUCTION: 4" CONCRETE SLAB PITCHED TOWARDS OVERHEAD DOOR OVER POLY/VAPOR BARRIER OVER SAND BED GRANULAR FILL GARAGE WALLS: INSULATE WALLS & CEILINGS 5/8" TYPE-X GYP. BD. & FINISH TAPE ON ALL INTERIOR GARAGE WALLS & CEILINGS FLOOR OVER GARAGE: -HEAT DUCT & SEWER WRAPPED & FOAMED -HOLD HEAT DUCT & SEWER TIGHT TO SUBFLOOR -BLOWN INSULATION (R-49) NEW ROOF TRUSSES PER MFG. SPEC. GIRDER TRUSS PER MFG. SPEC. 18" PARALLEL CHORD TRUSSES PER MFG. SPEC. 10' - 11 1/2"51' - 6"9' - 11 1/2"Upper Level to Apex of Vault11' - 0 13/16"New First Floor Clg.8' - 11 3/4" 3' - 0"6"NEW CRAWL SPACE6 1/4"BEAM DROPPED PER MFG. SPEC. Existing First Floor 0' - 0" Existing Second Floor10' - 6 1/2" Roof 18' - 7 5/8" Exst. Raised First Floor1' - 6" Exst. Raised First Floor Clg.9' - 10 1/2"8' - 1 1/8"1' - 6 3/4"8' - 11 3/4"10"6 1/4"1' - 6"8' - 1 1/8"8"8' - 4 1/2"8"7' - 5 3/4"3/4" SUBFLOOR 18" FLOOR TRUSSES @ 19.2" O.C. EXISTING 2X8 FLOOR SYSTEM EXISTING 2X8 FLOOR SYSTEM EXISTING 2X10 FLOOR SYSTEM 3/4" SUBFLOOR 24" FLOOR TRUSSES @ 19.2" O.C. EXISTING BEAMS Exst.Exst. New New 4' - 0 1/2"NEW CRAWL SPACE TO MATCH EXISTING BEAM OR GIRDER TRUSS PER MFG. SPEC.8' - 1 1/8"8"8' - 4 1/2"ZERO ENTRY GARAGE SLAB INTO HOUSE T.O. GARAGE FOUNDATION TO MATCH EXISTING GARAGE BEAM FLUSHED PER MFG. SPEC.3' - 6"New Heel13 5/8"MUD ROOM FAMILY ROOM DININGGREAT ROOM GARAGE 3/4" SUBFLOOR 2X6 TRD. JOISTS @ 16" O.C. NEW ROOF TRUSSES PER MFG. SPEC.NEW ROOF TRUSSES PER MFG. SPEC. 8" 12" 8" 12"Heel18 5/16"NEW ROOF TRUSSES PER MFG. SPEC. OWNER'S SUITEBDRM #2 BDRM #3 BONUS ROOM EXISTING CRAWL SPACEEXISTING CRAWL SPACE NEW GIRDER TRUSS PER MFG. SPEC. 1 8 "18"18" PARALLEL CHORD TRUSSES PER MFG. SPEC. 36" 24" 12" 12" FLOOR OVER GARAGE: -HEAT DUCT & SEWER WRAPPED & FOAMED -HOLD HEAT DUCT & SEWER TIGHT TO SUBFLOOR -BLOWN INSULATION (R-49) NOTE: PROVIDE EXISTING CRAWL SPACE & FOUNDATION AREA TO BE SEALED WITH VAPOR BARRIER GRADE MUST BE MINIMUM OF 6" BELOW TOP OF FOUNDATION WALL B.O. FOOTING @ MIN. 42" BELOW GRADE TYPICAL SLAB CONSTRUCTION: 4" CONCRETE SLAB PITCHED TOWARDS OVERHEAD DOOR OVER POLY/VAPOR BARRIER OVER SAND BED GRANULAR FILL GARAGE WALLS: INSULATE WALLS & CEILINGS 5/8" TYPE-X GYP. BD. & FINISH TAPE ON ALL INTERIOR GARAGE WALLS & CEILINGS 10' - 11 1/2"23' - 0 1/2"28' - 5 1/2"45' - 11 1/2" BDRM #3 CLOSET New First Floor Clg. 8' - 11 3/4"Ceiling Height Varies w/ Vault2' - 0 3/4"T.O. Foundation to B.O. Trusses8' - 11 1/4"Upper Level to Apex of Vault8" 12"6"NEW 2x10 JOISTS TO MATCH EXISTING NOTE: PROVIDE NEW CRAWL SPACE & FOUNDATION AREA W/ SEALED WITH VAPOR BARRIER BEAM DROPPED PER MFG. SPEC. Existing Second Floor 10' - 6 1/2" Roof 18' - 7 5/8" Lowered First Floor-0' - 6 1/4"8' - 1 1/8"11' - 0 3/4"12 6 Heel11 3/8"Heel11 3/8"Heel40 3/4"NEW SCISSOR TRUSSES PER MFG. SPEC. 2' - 0" 3 1/2" 12" BEAM FLUSHED PER MFG. SPEC. 3/4" SUBFLOOR 24" FLOOR TRUSSES @ 19.2" O.C. ZERO ENTRY GARAGE SLAB INTO HOUSE T.O. GARAGE FOUNDATION TO MATCH EXISTING GARAGE 3' - 6"3' - 6"BONUS ROOM GARAGE 8" 12" 3' - 0" GRADE MUST BE MINIMUM OF 6" BELOW TOP OF FOUNDATION WALL B.O. FOOTING @ MIN. 42" BELOW GRADE TYPICAL SLAB CONSTRUCTION: 4" CONCRETE SLAB PITCHED TOWARDS OVERHEADR DOOR OVER POLY/VAPOR BARRIER OVER SAND BED GRANULAR FILL GARAGE WALLS: INSULATE WALLS & CEILINGS 5/8" TYPE-X GYP. BD. & FINISH TAPE ON ALL INTERIOR GARAGE WALLS & CEILINGS FLOOR OVER GARAGE: -HEAT DUCT & SEWER WRAPPED & FOAMED -HOLD HEAT DUCT & SEWER TIGHT TO SUBFLOOR -BLOWN INSULATION (R-49) 10' - 8 1/2"10' - 8 1/2" 2" 12"Upper Level to Apex of Vault9' - 9 9/16"DRAWN BY DESCRIPTION PROJECT # PROJECT ISSUE RE-ISSUE BUILDER a18476 KENRICK AVE. SUITE #202 LAKEVILLE, MN 55044 TEL: 952.428.8200 EM: Dave@DavidCharlezDesigns.com D A V I D C H A R L E Z D E S I G N SD A V I D C H A R L E Z D E S I G N S Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2023. Do not replicate with out permission (952)-428-8200. David Charlez Design retains rights to all plans and detail shown. 2/16/2023 3:37:50 PM 13Cross Sections MISC - Beduhn - CD Beduhn Remodel BUILDER BY HOMEOWNER1.12.2022GM 1340 Vine Place Orono, MN 1/4" = 1'-0" 1Section - Family Rm/Garage 1/4" = 1'-0" 2Section - Great Room/Garage 1/4" = 1'-0" 3 Section - Garage REVISION SCHEDULE Number Date Issued by CDRev1 1.18.2023 GM CDRev2 1.24.2023 JCB CDRev3 2.2.2023 GM CDRev4 2.16.2023 LMC Existing First Floor0' - 0" Existing Second Floor 10' - 6 1/2" Roof18' - 7 5/8"8' - 1 1/8"1' - 6 3/4"8' - 11 3/4"10"EXISTING 2X10 FLOOR SYSTEM EXISTING CRAWL SPACE Exst.New 3/4" SUBFLOOR 18" FLOOR TRUSSES @ 19.2" O.C.8' - 1 1/8"1' - 6 3/4"8' - 11 3/4"Heel30 1/4"3' - 0" 14 4 3' - 6"2' - 0 3/4"8' - 7 3/4"6 1/4"7' - 0"2' - 6" BEAM FLUSHED PER MFG. SPEC. NEW ROOF TRUSSES PER MFG. SPEC. NEW ROOF TRUSSES PER MFG. SPEC. 8" 12" FRONT PORCH PORCH FLAT ROOF: EPDM RUBBER MEMBRANE RIGID INSULATION @ 1/4" SLOPE 3/4" SHEATHING 24" ROOF TRUSSES @ 24" O.C. OPT. PINE T&G CLG. FAMILY ROOM FOYER BDRM #2NEW LOFT New BEAM FLUSHED PER MFG. SPEC. NOTE: PROVIDE EXISTING CRAWL SPACE & FOUNDATION AREA TO BE SEALED WITH VAPOR BARRIER 22' - 2 1/2"10' - 8 1/2" GIRDER TRUSS PER MFG. SPEC. New First Floor Clg.8' - 11 3/4" EXST. DECK4"Existing Second Floor 10' - 6 1/2" Roof18' - 7 5/8" Lowered First Floor-0' - 6 1/4"8' - 1 1/8"1' - 6 3/4"9' - 6"Heel11 3/8"Heel30 1/4"3 1/2" 12" 8" 12"8' - 1 1/8"1' - 6 3/4"9' - 6"3/4" SUBFLOOR 18" FLOOR TRUSSES @ 19.2" O.C. BEAM FLUSHED PER MFG. SPEC.3' - 6"2' - 0 3/4"9' - 2"NEW ROOF TRUSSES PER MFG. SPEC. New BEAM FLUSHED PER MFG. SPEC. FRONT PORCH PORCH FLAT ROOF: EPDM RUBBER MEMBRANE RIGID INSULATION @ 1/4" SLOPE 3/4" SHEATHING 24" ROOF TRUSSES @ 24" O.C. OPT. PINE T&G CLG. 9' - 6" GUEST RMLAKE BATH BDRM #3 BDRM #4 2' - 0" 3' - 0" 14 4 Sim NOTE: PROVIDE NEW CRAWL SPACE & FOUNDATION AREA TO BE SEALED WITH VAPOR BARRIER. MATCH EXISTING 22' - 2 1/2"10' - 8 1/2" New First Floor Clg.8' - 11 3/4"4"NEW 2x10 JOISTS TO MATCH EXISITNG FLOOR SYSTEM NEW CRAWL SPACE NEW DROPPED BEAM PER MFG. SPEC. Existing First Floor 0' - 0" Existing Second Floor10' - 6 1/2" Roof 18' - 7 5/8" Exst. Raised First Floor1' - 6" Exst. Raised First Floor Clg.9' - 10 1/2"8' - 1 1/8"8"8' - 4 1/2"29' - 0"8' - 1 1/8"8"8' - 4 1/2"8"EXISTING 2X8 FLOOR SYSTEM EXISTING CRAWL SPACE EXISTING 2X8 FLOOR SYSTEM2' - 0 3/4"8' - 7 3/4"6 1/4"PORCH FLAT ROOF: EPDM RUBBER MEMBRANE RIGID INSULATION @ 1/4" SLOPE 3/4" SHEATHING 24" ROOF TRUSSES @ 24" O.C. OPT. PINE T&G CLG.3' - 6"12"12" NEW ROOF TRUSSES PER MFG. SPEC. Exst.Exst.New EXST. MECH KITCHENPOCKET OFFICE FRONT PORCH OPEN TO KITCHEN BELOWOWNER'S BATH 28' - 10"36' - 5 1/2" NOTE: PROVIDE EXISTING CRAWL SPACE & FOUNDATION AREA TO BE SEALED WITH VAPOR BARRIER 3' - 0"11 11/16"2X4 LOOKOUTS 2X 4 T R U S S T A I L S Energy Heel30 1/4"METAL DRIP EDGE 5/4" x 8" COMP. FASCIA 3/4" BACKING 4/4" x 12" COMP. FASCIA 17-1/2" x 1-1/4" RIM BOARD SUB FASCIA COMPOSITE VENTED SOFFITS 8" 12" DRAWN BY DESCRIPTION PROJECT # PROJECT ISSUE RE-ISSUE BUILDER a18476 KENRICK AVE. SUITE #202 LAKEVILLE, MN 55044 TEL: 952.428.8200 EM: Dave@DavidCharlezDesigns.com D A V I D C H A R L E Z D E S I G N SD A V I D C H A R L E Z D E S I G N S Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2023. Do not replicate with out permission (952)-428-8200. David Charlez Design retains rights to all plans and detail shown. 2/16/2023 3:37:56 PM 14Cross Sections MISC - Beduhn - CD Beduhn Remodel BUILDER BY HOMEOWNER1.12.2022GM 1340 Vine Place Orono, MN 1/4" = 1'-0" 1Section - Family Rm/Front Porch 1/4" = 1'-0" 2 Section - Lake Bath/Front Porch 1/4" = 1'-0" 3Section - Pocket Office/Front Porch 1" = 1'-0" 4 Detail - Eave @ New Loft IMPORTANT REMODEL NOTE: VERIFY ALL HEIGHTS AND SIZES OF EXISTING WINDOWS, DOORS, AND ROOF. VERIFY FLOOR AND WALL HEIGHTS IN THE EFFECTED AREA PRIOR TO ORDERING MATERIALS OR STARTING CONSTRUCTION ALL DIMENSIONS LINES TO BE TO CENTERLINE OF STUDS TO FACE OF SHEATHING ALL OVERALL DIMENSION LINES TO BE FACE OF STUD TO FACE OF SHEATHING VERIFY ALL HEIGHTS AND SIZES OF EXISTING CONSTRUCTION MATERIALS: WALL STUDS, FLOOR JOISTS, SUB FLOOR, AND ROOF TRUSSES PRIOR TO ORDERING MATERIALS OR STARTING CONSTRUCTION FIELD VERIFY OVERHANGS AND ROOF PITCH PRIOR TO ORDERING ROOF TRUSSES OR STARTING CONSTRUCTION ALL MODIFICATIONS AND NEW LOADS APPLIED TO THE EXISTING ROOF STRUCTURE WILL BE VERIFIED BY AN ENGINEER WHO WILL PROVIDED DRAWING AND SPECIFICS STRUCTURAL ENGINEERS SIGNATURE IS NEEDED BEFORE PLANS CAN BE SUBMITTED TO CITY OF ORONO FOR APPROVAL. ENGINEER WILL VERIFY THAT ALL MODIFICATIONS TO THE PROJECT MEET STATE AND LOCAL GOVERNMENT REQUIREMENTS REVISION SCHEDULE Number Date Issued by CDRev1 1.18.2023 GM CDRev2 1.24.2023 JCB CDRev3 2.2.2023 GM CDRev4 2.16.2023 LMC Existing Second Floor10' - 6 1/2" Roof18' - 7 5/8" Exst. Raised First Floor 1' - 6" Exst. Raised First Floor Clg. 9' - 10 1/2"8' - 1 1/8"8"8' - 4 1/2"3' - 0"3' - 0"Heel26 1/4"Heel26 1/4"New Window Hgt.16' - 0 1/2"New Window Hgt.16' - 0 1/2"8' - 1 1/8"8"8' - 4 1/2"8"6' - 10 1/2"EXST. BEAMS EXST. BEAM EXISTING 2X8 FLOOR SYSTEM EXISTING 2X8 FLOOR SYSTEM 8" 12" NEW ROOF TRUSSES PER MFG. SPEC. EXISTING CRAWL SPACE Exst.Exst. DININGKITCHEN loft NOTE: PROVIDE EXISTING CRAWL SPACE & FOUNDATION AREA TO BE SEALED WITH VAPOR BARRIER 14' - 5 1/2"14' - 5 1/2" Existing First Floor0' - 0" Existing Second Floor10' - 6 1/2"Existing Second Floor10' - 6 1/2" Roof 18' - 7 5/8" Exst. Raised First Floor1' - 6" Exst. Raised First Floor Clg.9' - 10 1/2"8' - 1 1/8"8"8' - 4 1/2"4' - 0 1/2"4' - 0 1/2"3/4" SUBFLOOR 24" FLOOR TRUSSES @ 19.2" O.C. BEAM FLUSHED PER MFG. SPEC.8' - 1 1/8"8"8' - 4 1/2"8"EXISTING BEAMS EXISTING 2X8 FLOOR SYSTEM EXISTING 2X8 FLOOR SYSTEM10 3/4"7' - 5 3/4"8' - 1 1/8"1' - 6 3/4"8' - 11 3/4"10"EXISTING 2X10 FLOOR SYSTEM 3/4" SUBFLOOR 18" FLOOR TRUSSES @ 19.2" O.C.6 1/4"1' - 6"Heel18 5/16"Heel18 5/16"18"1 8 "3' - 6"NewNew Exst.Exst. ROOF TRUSSES PER MFG. SPEC. NEW ROOF TRUSSES PER MFG. SPEC. EXISTING CRAWL SPACE EXISTING CRAWL SPACE 18" PARALLEL CHORD TRUSSES PER MFG. SPEC. 8" 12" 3' - 0"3' - 0" 1' - 0" 1' - 0"1' - 0"8' - 11 3/4"New GUEST RM MUD ROOMFOYER DININGGREAT ROOM GARAGE OWNER'S SUITEEXST. LOFT BDRM #4 BATH BONUS ROOMNEW LOFT 7' - 4 13/16"10' - 11 1/2"10' - 11 1/2"Upper Level to Apex of Vault11' - 0 13/16"New First Floor Clg. 8' - 11 3/4"2' - 0 3/4"T.O. Foundation to B.O. Trusses8' - 11 1/4"GRADE MUST BE MINIMUM OF 6" BELOW TOP OF FOUNDATION WALL B.O. FOOTING @ MIN. 42" BELOW GRADE TYPICAL SLAB CONSTRUCTION: 4" CONCRETE SLAB PITCHED TOWARDS FLOOR DRAINS SAND BED GRANULAR FILL6"ZERO ENTRY GARAGE SLAB INTO HOUSE NEW CRAWL SPACE TO MATCH EXISTING NEW 2x10 JOISTS TO MATCH EXISTING NOTE: PROVIDE NEW CRAWL SPACE & FOUNDATION AREA W/ SEALED WITH VAPOR BARRIER BEAM DROPPED PER MFG. SPEC. Existing First Floor0' - 0" Existing Second Floor10' - 6 1/2" Roof18' - 7 5/8"Heel6 1/4"8' - 1 1/8"1' - 6 3/4"8' - 11 3/4"10"PROPOSED GIRDER TRUSS PER MFG. SPEC.NEW ROOF TRUSSES PER MFG. SPEC.NEW ROOF TRUSSES PER MFG. SPEC. BEAM FLUSHED PER MFG. SPEC. 8" 12" EXISTING 2X10 FLOOR SYSTEM EXISTING 2X10 FLOOR SYSTEM 3/4" SUBFLOOR 18" FLOOR TRUSSES @ 19.2" O.C. BEAM FLUSHED PER MFG. SPEC. EXISTING CRAWL SPACE 11"7 7/16"5' - 7"4' - 11 1/2"TYPICAL STAIRCASE CONSTRUCTION: 6'-10" MINIMUM HEADROOM (4) 11- 7/8" STAIR STRINGER w/1-1/8" x 11-1/4" PARTICLE BOARD TREADS PROVIDE 34"-36" HGT HANDRAILS & GUARDS RAILS PER CODE TYPICAL STAIRCASE LANDING CONSTRUCTION: 2-2x8 HEADER 3/4" PLYWOOD BACKING 2x8 JOISTS @ 16" O.C. 3/4" PLYWOOD FAMILY ROOM STAIRS BDRM #2NEW LOFT 3' - 6"8' - 7 3/4"6 1/4"6' - 6" BEAM FLUSHED PER MFG. SPEC. New New Exst. NOTE: PROVIDE EXISTING CRAWL SPACE & FOUNDATION AREA TO BE SEALED WITH VAPOR BARRIER 13' - 8 1/2"22' - 2 1/2" LANDING BEAMS PER MFG. 6" New First Floor Clg.8' - 11 3/4" EXST. DECK 8' - 1 1/8"1' - 6 3/4"8' - 11 3/4"DRAWN BY DESCRIPTION PROJECT # PROJECT ISSUE RE-ISSUE BUILDER a18476 KENRICK AVE. SUITE #202 LAKEVILLE, MN 55044 TEL: 952.428.8200 EM: Dave@DavidCharlezDesigns.com D A V I D C H A R L E Z D E S I G N SD A V I D C H A R L E Z D E S I G N S Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2023. Do not replicate with out permission (952)-428-8200. David Charlez Design retains rights to all plans and detail shown. 2/16/2023 3:38:01 PM 15Cross Sections MISC - Beduhn - CD Beduhn Remodel BUILDER BY HOMEOWNER1.12.2022GM 1340 Vine Place Orono, MN 1/4" = 1'-0" 1Section - Dining/Kitchen 1/4" = 1'-0" 2Section - Owner's Suite/Bonus Room 1/4" = 1'-0" 3 Section - Stairs/Family Room IMPORTANT REMODEL NOTE: VERIFY ALL HEIGHTS AND SIZES OF EXISTING WINDOWS, DOORS, AND ROOF. VERIFY FLOOR AND WALL HEIGHTS IN THE EFFECTED AREA PRIOR TO ORDERING MATERIALS OR STARTING CONSTRUCTION ALL DIMENSIONS LINES TO BE TO CENTERLINE OF STUDS TO FACE OF SHEATHING ALL OVERALL DIMENSION LINES TO BE FACE OF STUD TO FACE OF SHEATHING VERIFY ALL HEIGHTS AND SIZES OF EXISTING CONSTRUCTION MATERIALS: WALL STUDS, FLOOR JOISTS, SUB FLOOR, AND ROOF TRUSSES PRIOR TO ORDERING MATERIALS OR STARTING CONSTRUCTION FIELD VERIFY OVERHANGS AND ROOF PITCH PRIOR TO ORDERING ROOF TRUSSES OR STARTING CONSTRUCTION ALL MODIFICATIONS AND NEW LOADS APPLIED TO THE EXISTING ROOF STRUCTURE WILL BE VERIFIED BY AN ENGINEER WHO WILL PROVIDED DRAWING AND SPECIFICS STRUCTURAL ENGINEERS SIGNATURE IS NEEDED BEFORE PLANS CAN BE SUBMITTED TO CITY OF ORONO FOR APPROVAL. ENGINEER WILL VERIFY THAT ALL MODIFICATIONS TO THE PROJECT MEET STATE AND LOCAL GOVERNMENT REQUIREMENTS REVISION SCHEDULE Number Date Issued by CDRev1 1.18.2023 GM CDRev2 1.24.2023 JCB CDRev3 2.2.2023 GM CDRev4 2.16.2023 LMC ABBREVIATIONS LIST = AIR CONDITIONING = ABOVE FINISHED FLOOR = ALUMINIUM = BOTTOM CHORD BEARING = BOARD = BEDROOM = BUILT IN = BEAM = BOTTOM OF = BEARING = BASEMENT = CABINETS = CANTLIEVER = CEILING = CENTER LINE = CASED OPENING = CONCRETE = CONTINUOUS = CARPET = CERAMIC TILE = CASEMENT = DOUBLE = DEMOLISH OR DEMOLITION = DOUBLE HUNG = DIAMETER = DIMENSION(S) = DOWN = DRYWALL OPENING = DOOR = DISHWASHER = DRAWING = EACH = ENERGY HEEL = ELECTRIC = ELEVATIONS OR ELEVATOR = ENGINEER = ETHYLENE PROPYLENE DIENE M-CLASS = EQUAL = EXTERIOR = EXISTING = FLOOR DRAIN = FINISHED = FLOOR = FOUNDATION = FIREPLACE = FRAMING = FREEZER = FOOTING = FURNITURE = FUTURE = FIXED = GLIDER = GIRDER TRUSS = GYPSUM = GYPSUM BOARD = HEADER = HEIGHT = HEATING VENTILATION AIR CONDITIONING = IN FLOOR HEAT = INSULATION = INTERIOR = LANDING = LINEN = LOCKERS = LOWER LEVEL = LOOKOUT = LUXURY VINYL TILE = LUXURY VINYL PLANK = MAXIMUM = MECHANICAL = MANUFACTURE(R) = MINIMUM = MAIN LEVEL = MASONRY OPENING = NUMBER = NOMINAL = ON CENTER = OFFICE = OPENING = OPTION(AL) = POLISHED CONCRETE = PERIMETER = POCKET = PLUMBING = PLYWOOD = POWDER = POLYVINYL CHLORIDE = REFRIGERATOR = REQUIRED = ROOM = ROD & SHELF = SIMULATED DIVIDED LITE = SMOKE DETECTOR = SMOKE / CARBON MONOXIDE DETECTOR = SINGLE HUNG = SHELVING = SHELVES = SIMILAR OR SIMULATOR = SLIDER = SINK = SPECIFICATION(S) OR SPECIFIED = STEEL = STORAGE = STRUCTURAL = SQUARE FOOTAGE = TO BE DETERMINED = TOP CHORD BEARING = TONGUE AND GROOVE = TOP OF = TREATED = TRANSOM = TYPICAL = UPPER LEVEL = UNFINISHED = VANITY = WOOD = WINDOW = WALK IN CLOSET = WITH = WALKOUT = WASHER A.C. A.F.F. ALUM. B.C.B. BD. BDRM. B.I. B'M B.O. BRG. BSMT. CABS. CANT. CLG. C.L. C.O. CONC. CONT. CPT. C.T. CSMT DBL. DEMO D.H. DIA. DIM(S) DN. D.O. DR. D.W. DWG. EA. E.H. ELEC. ELEV. ENG. EPDM EQ. EXT. EXST. F.D. FIN. FLR. FND. F/P FRMG. FRZ. FTG. FURN. FUT. FX. GLD. G.T. GYP. GYP. BD. HDR. HGT. HVAC I.F.H. INSUL. INT. LDG. LIN. LKRS. L.L. L.O. L.V.T. L.V.P. MAX. MECH. MFG. MIN. M.L. M.O. NO. NOM. O.C. OFF. OP'NG OPT. P. CONC. PERM. PKT. PLMG. PLWD. PWDR PVC REF. REQD RM. R&S S.D.L. SD. SD/CO S.H. SHLVG. SHLVS. SIM. SLD. SNK SPEC. ST'L ST'RG STRUC. SQ. FTG. TBD. T.C.B. T&G T.O. TRD. TRSM. TYP. U.L. UNFIN. VTY. W'D WDW W.I.C. W/ W.O. WSHR. DRAWN BY DESCRIPTION PROJECT # PROJECT ISSUE RE-ISSUE BUILDER a18476 KENRICK AVE. SUITE #202 LAKEVILLE, MN 55044 TEL: 952.428.8200 EM: Dave@DavidCharlezDesigns.com D A V I D C H A R L E Z D E S I G N SD A V I D C H A R L E Z D E S I G N S Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2023. Do not replicate with out permission (952)-428-8200. David Charlez Design retains rights to all plans and detail shown. 2/16/2023 3:38:06 PM 16Schedules & Notes MISC - Beduhn - CD Beduhn Remodel BUILDER BY HOMEOWNER1.12.2022GM 1340 Vine Place Orono, MN GENERAL NOTES 1. ALL EXTERIOR WALLS TO BE CONSTRUCTED OF 2x6 STUDS @ 16" O.C. 2. ALL INTERIOR WALLS TO BE CONSTRUCTED OF 2x4 STUDS @ 16" O.C. (UNLESS OTHERWISE NOTED) 3. WALLS ADJACENT TO GARAGE SPACE SHALL BE 2x6 WITH A 1 HR. FIRE RATING 4. STRUCTURAL WALLS TO HAVE A FIRE RATING OF 1 HR. 5. ALL DIMENSIONS LINES TO BE TO CENTERLINE OF STUDS TO FACE OF STUD 6. PROVIDE ROOF VENTILATION 1 SQ.FT. PER 300 SQ.FT. OF ROOF AREA. 50% AT RIDGE AND 50% AT SOFFIT-MIN 7.ALL INTERIOR DOOR HEAD HEIGHT TO BE VERIFIED BY BUILDER UNLESS OTHERWISE NOTED. UNDERCUT MIN 1" 8. ALL STRUCTURAL MEMBERS TO BE VERIFIED BY MANF. AND A STRUCTURAL ENGINEER. 9. ALL WINDOW UNITS ABOVE TUB DECK AND/OR WITHIN 18" OF THE FLOOR AND/OR 24" OF A DOORWAY SHALL BE TEMPERED GLASS 10. PROVIDE AN APPROVED ICE AND WATER ROOFING STARTER EDGE PER CODE OR EQUIVALENT 11. WRAP ALL CANTILEVERS WITH AN APPROVED POLY AND SPRAY FOAM FLOOR 12. SLOPE FINISHED GRADE AWAY FROM THE HOUSE ON ALL SIDES 13. 1/2" AIR SPACE ON EACH SIDE OF MICRO-LAM BEAM & MIN 3" BEARING ON CONCRETE 14. EXTERIOR RAILING TO BE MIN OF 36" HIGH AND BUILT AS TO NOT ALLOW A 4" SPHERE TO PASS THROUGH 15. ALL COMPONENTS TO BE INSTALLED TO MANF. SPEC OR LOCAL CODE 16. ALL WOOD IN DIRECT CONTACT WITH CONCRETE OR MASONRY IS TO BE PRESSURE TREATED OR WOOD SPECIES THAT HAS A NATURAL RESISTANCE TO DECAY 17. PROVIDE A WATER RESISTIVE GYP BOARD AROUND ALL SHOWERS AND TUBS 18. LIGHT OR FAN HOUSING SYSTEM RECESSED THROUGH AN EXTERIOR VAPOR BARRIER SHALL BE OF THE AIR SEALED TYPE OR BE BOXED AND SEALED PER CODE 19. PROVIDE DRAFT STOPS PER UBC 708.3 20. FIRE BLOCK ALL CHASES AT EACH FLOOR-CEILING ASSEMBLY OR AT 10' MAX INTERVALS 21. ALL SMOKE DETECTORS TO BE HARD WIRED WITH BATTERY BACKUP PER CODE 22. MAINTAIN A 6" SEPARATION BETWEEN GRADE AND WOOD 23. CAULK AND FLASH AROUND ALL EXTERIOR OPENINGS 24. PLUMBING PENETRATIONS IN WALL ASSEMBLY SHALL BE FIRE CAULKED WITH LISTED MATERIALS 25. BLOCK PATIO DOORS WITHOUT A DECK 26. SMOKE DETECTORS SHALL BE MIN 16" AWAY FROM WALL AND INSTALL TO MANF. SPEC 27. NO OPENING IN ROOF WITHIN 5' OF PROPERTY LINES 28. 10% OF THE FLOOR AREA IS REQUIRED FOR LIGHT AND VENTILATION IN ALL HABITABLE ROOMS 29. ON EXTERIOR, GRIPPABLE HANDRAILS 34" TO 36" IN HEIGHT FROM THE NOSE OF THE STAIRS 30. COMBUSTION AIR DUCTS 12" OFF THE FLOOR OR RETURN AIR PLENUM WHEN REQUIRED (IMC703) 31. PROVIDE PLUMBING ACCESS AT ALL TUBS EXCEPT WHEN TRAPS & OVERFLOW GLUED 32. PROVIDE 50 cfm OR 20 cfm CONTINUOUS VENTILATION OR OPERABLE WINDOW (ASHRAE 62-2001 6.1) 33. DRYER VENT TO THE EXTERIOR- INSULATE LAST 3 FEET MIN 36" CLEARANCE TO OTHER OPENINGS: (IMC504.4, 401.52 AND 604.1) 34. CERAMIC TILE TO BE APPLIED OVER GREEN BOARD, CEMENT BOARD, WONDER BOARD OR OTHER APPROVED MATERIAL TO A HEIGHT OF 70" ABOVE DRAIN INLET IN SHOWERS. CEMENT BOARD MUST BE USED ON EXTERIOR WALLS UNDERNEATH TILE AND OVER THE VAPOR BARRIER (R307) 35. TRUSS PLANS STAMPED AND APPROVED BY MANF. SHALL BE ON THE JOB SITE. ALTERATIONS TO TRUSSES REQUIRE AN ENGINEER'S APPROVAL 36. RAFTERS SHALL BE FRAMED TO MIN 1" THICK RIDGE BOARD NOT LESS THAN THE DEPTH OF THE CUT END OF THE RAFTERS OR NAILED TO EACH OTHER WITH A GUSSET PLATE A TIE. THE RIDGE BOARD MUST BE SUPPORTED ON END WALL OR MIN 2x4 COLLAR TIES ARE REQUIRED AT MIN 4" O.C. 37. 4-MIL VAPOR BARRIER ON WARM IN WINTER SIDE OF EXTERIOR WALLS AND CEILING. FIRE RETARDANT VAPOR BARRIER MAY BE LEFT UNCOVERED 38. WIND-WASH AT AL EAVES, CORNERS, OVERHANGS, AND BY WINDOWS. SHEATHING INSULATION DAM @ CEILING CHANGES 39. WEATHER-RESISTIVE BARRIER-i.e. BUILDING WRAP TABLE R703.4 40. HOT WATER PIPING LOCATED OUTSIDE OF CONDITIONED SPACE WILL BE INSULATED TO AT LEAST R-3 41. ATTIC ACCESS DOORS FROM CONDITIONED TO UNCONDITIONED SPACES SHALL BE WEATHERED- STRIPPED AND INSULATED. 42. NEW WOOD-BURNING FIREPLACES WILL HAVE TIGHT-FITTING FLUE DAMPERS AND OUTDOOR COMBUSTION AIR. 43. FOR WINDOWS WHERE THE LOWEST PART OF THE WINDOW OPENING IS MORE THAN 6' ABOVE THE GROUND, THE LOWEST PART OF OPENING SHALL BE MIN. OF 36" ABOVE THE FINISHED FLOOR. EXCEPTIONS INCLUDE WINDOWS THAT DO NOT OPEN MORE THAN 4", WINDOWS WITH FALL PROTECTION, AND WINDOWS THAT HAVE OPENING CONTROL DEVICES. 44. DWELLINGS WITH ATTACHED GARAGES OR FUEL FIRED EQUIPMENT MUST BE EQUIPPED WITH CARBON MONOXIDE ALARMS OUTSIDE OF, BUT NO FURTHER THAN 10' FROM , EACH SLEEPING AREA OR BEDROOM. 45. FOOTINGS SHALL HAVE A MIN. COMPRESSIVE STRENGTH OF 5,000 psi. 46. A MIN. 1/2" GYPSUM BOARD MEMBRANE, OR 5/8" WOOD STRUCTURAL PANEL MEMBRANE, SHALL BE PROVIDED ON THE UNDERSIDE OF FLOOR ASSEMBLIES. EXCEPTIONS A.DWELLINGS EQUIPPED WITH SPRINKLER SYSTEM. B.CRAWLSPACES C.PORTIONS OF FLOOR ASSEMBLIES WITH PROPORTIONALLY SMALL AREA. D. FLOOR ASSEMBLIES CONSTRUCTED OF SOLID SAWN LUMBER OR STRUCTURAL COMPOSITE LUMBER WITH MIN. NOMINAL DIMENSIONS OF 2"x10". 47. DECKS SUPPORTED BY ATTACHMENT TO AN EXTERIOR WALL SHALL BE POSITIVELY ANCHORED TO THE PRIMARY STRUCTURE AND DESIGNED FOR BOTH VERTICAL AND LATERAL LOADS. 48. FLASHING WITH A MIN. 3 1/2" VERTICAL ATTACHMENT FLANGE IS REQUIRED AT THE INTERSECTION OF THE FOUNDATION AND RIM JOIST FRAMING WHEN THE EXTERIOR WALL COVERING DOES NOT LAP THE FOUNDATION INSULATION. THE FLASHING MUST EXTEND A MIN. OF 1" BELOW THE FOUNDATION PLATE LINE, AND THE REQUIRED WATER-RESISTIVE BARRIER MUST LAP OVER THE ATTACHMENT FLANGE. 49. BUILDING FRAMING CAVITIES SHALL NOT BE USED AS DUCTS OR PLENUMS D O O R S C H E D U L E Tag Door Size Door Type Quantity Head Height Level 101 ELSFD12070 Marvin Elevate Sliding French 4-Panel 1 7' - 2"Exst. Raised First Floor 102 UBFLD9080-3P Marvin Ultimate Bi-Fold 1 7' - 11 1/2"Existing First Floor 103 ELIFD3080 Marvin Elevate Inswing French 1-Panel 1 7' - 11 1/2"Lowered First Floor 104 ELIFD3080 Marvin Elevate Inswing French 1-Panel 1 7' - 11 1/2"Lowered First Floor 105 9'-0" x 8'-0"Single Overhead Garage Door 1 8' - 0"Grade 106 18'-0" x 8'-0"Double Overhead Garage Door 1 8' - 0"Grade 107 9'-0" x 8'-0"Single Overhead Garage Door 1 8' - 0"Grade 108 ELIFD3080 Marvin Elevate Inswing French 1-Panel 1 7' - 11 1/2"Existing First Floor 109 32" x 80"Single Swing (Interior)1 6' - 8"Exst. Raised First Floor 110 32" x 80"Single Swing (Interior)1 6' - 8"Exst. Raised First Floor 111 60" x 80"Double Swing (Interior)1 6' - 8"Lowered First Floor 112 36" x 80"Single Swing (Interior)1 6' - 8"Lowered First Floor 113 36" x 80"Single Pocket (Interior)1 6' - 8"Lowered First Floor 114 36" x 80"Single Swing (Interior)1 6' - 8"Lowered First Floor 115 36" x 80"Single Swing (Interior)1 6' - 8"Existing First Floor 116 36" x 80"Single Pocket (Interior)1 6' - 8"Lowered First Floor 117 36" x 80"Fire Door - 20min. Rated 1 6' - 8"Lowered First Floor 118 36" x 80"Single Pocket (Interior)1 6' - 8"Lowered First Floor 201 30" x 80"Single Swing (Interior)1 6' - 8"Existing Second Floor 202 36" x 80"Single Swing (Interior)1 6' - 8"Existing Second Floor 203 30" x 80"Single Swing (Interior)1 6' - 8"Existing Second Floor 204 30" x 80"Single Swing (Interior)1 6' - 8"Existing Second Floor 205 60" x 80"Double Swing (Interior)1 6' - 8"Existing Second Floor 206 30" x 80"Single Pocket (Interior)1 6' - 8"Existing Second Floor 207 48" x 80"Double Swing (Interior)1 6' - 8"Existing Second Floor 208 30" x 80"Single Swing (Interior)1 6' - 8"Existing Second Floor 209 72" x 80"Double Bi-Pass Door (Interior)1 6' - 8"Existing Second Floor 210 72" x 80"Double Bi-Pass Door (Interior)1 6' - 8"Existing Second Floor 211 30" x 80"Single Swing (Interior)1 6' - 8"Existing Second Floor 212 30" x 80"Single Swing (Interior)1 6' - 8"Existing Second Floor 213 30" x 80"Single Swing (Interior)1 6' - 8"Existing Second Floor 214 36" x 80"Single Pocket (Interior)1 6' - 8"Existing Second Floor 215 36" x 80"Single Swing (Interior)1 6' - 8"Existing Second Floor 216 36" x 80"Single Swing (Interior)1 6' - 8"Existing Second Floor 217 36" x 80"Single Swing (Interior)1 6' - 8"Existing Second Floor 218 USPD12070 Marvin Ultimate Sliding Patio 3-Panel 1 7' - 2"Existing Second Floor Grand total: 36 M A R V I N W I N D O W S C H E D U L E TagWindow CodeWindow TypeQuantity Head Height Level Room Location 01ELCAP5763Marvin Elevate Casement Picture 1 7' - 0"Exst. Raised First Floor 02ELAWN5763Marvin Elevate Awning 1 1' - 8 7/8"Exst. Raised First Floor 03ELCAP7363Marvin Elevate Casement Picture 1 7' - 0"Exst. Raised First Floor 04ELCAP7319Marvin Elevate Casement Picture 1 1' - 8 7/8"Exst. Raised First Floor 05ELCAP4963Marvin Elevate Casement Picture 1 7' - 0"Exst. Raised First Floor 06ELCAP4963Marvin Elevate Casement Picture 1 7' - 0"Exst. Raised First Floor 07ELCAP4963Marvin Elevate Casement Picture 1 7' - 0"Exst. Raised First Floor 08ELAWN4919Marvin Elevate Awning 1 1' - 8 7/8"Exst. Raised First Floor 09ELAWN4919Marvin Elevate Awning 1 1' - 8 7/8"Exst. Raised First Floor 10ELAWN4919Marvin Elevate Awning 1 1' - 8 7/8"Exst. Raised First Floor 11ELCA3771Marvin Elevate Casement 1 8' - 0"Existing First Floor 12ELAWN3719Marvin Elevate Awning 1 2' - 0 7/8"Existing First Floor 13ELCA3771Marvin Elevate Casement 1 8' - 0"Existing First Floor 14ELAWN3719Marvin Elevate Awning 1 2' - 0 7/8"Existing First Floor 15ELCA3355Marvin Elevate Casement 1 8' - 0"Lowered First Floor 16ELCA3355Marvin Elevate Casement 1 8' - 0"Lowered First Floor 17ELCAP3371Marvin Elevate Casement Picture 1 8' - 0"Grade 18ELCAP3371Marvin Elevate Casement Picture 1 8' - 0"Grade 19ELCAP3371Marvin Elevate Casement Picture 1 8' - 0"Grade 20ELAWN3323Marvin Elevate Awning 1 8' - 0"Lowered First Floor 21ELAWN3323Marvin Elevate Awning 1 8' - 0"Lowered First Floor 22ELCA3371Marvin Elevate Casement 1 8' - 0"Lowered First Floor 23ELCAP4971Marvin Elevate Casement Picture 1 8' - 0"Lowered First Floor 24ELCA3371Marvin Elevate Casement 1 8' - 0"Lowered First Floor 25ELCAP5771Marvin Elevate Casement Picture 1 8' - 0"Existing First Floor 26ELCA3343Marvin Elevate Casement 1 7' - 0"Exst. Raised First Floor 27ELCAP5747Marvin Elevate Casement Picture 1 7' - 0"Exst. Raised First Floor 28ELCAP5763Marvin Elevate Casement Picture 1 7' - 0"Existing Second Floor 29ELCAP7363Marvin Elevate Casement Picture 1 7' - 0"Existing Second Floor 30ELCAP3763Marvin Elevate Casement Picture 1 7' - 0"Existing Second Floor 31ELCAP3763Marvin Elevate Casement Picture 1 7' - 0"Existing Second Floor 32ELCAP3763Marvin Elevate Casement Picture 1 7' - 0"Existing Second Floor 33ELCAP3763Marvin Elevate Casement Picture 1 7' - 0"Existing Second Floor 34ELCA3363Marvin Elevate Casement 1 7' - 0"Existing Second Floor 35ELCA3363Marvin Elevate Casement 1 7' - 0"Existing Second Floor 36ELAWN3719Marvin Elevate Awning 2 7' - 0"Existing Second Floor 37ELAWN3719Marvin Elevate Awning 1 7' - 0"Existing Second Floor 38ELCA3763Marvin Elevate Casement 1 7' - 0"Existing Second Floor 39ELCA3763Marvin Elevate Casement 1 7' - 0"Existing Second Floor 40ELCA3763Marvin Elevate Casement 1 7' - 0"Existing Second Floor 41ELCA3363Marvin Elevate Casement 1 7' - 0"Existing Second Floor 42ELCA3363Marvin Elevate Casement 1 7' - 0"Existing Second Floor 43ELCA3363Marvin Elevate Casement 1 7' - 0"Existing Second Floor 44ELCA3363Marvin Elevate Casement 1 7' - 0"Existing Second Floor 45ELCA3363Marvin Elevate Casement 1 7' - 0"Existing Second Floor 46ELCA3363Marvin Elevate Casement 1 7' - 0"Existing Second Floor 47ELCA3363Marvin Elevate Casement 1 7' - 0"Existing Second Floor 48ELCA3363Marvin Elevate Casement 1 7' - 0"Existing Second Floor 49ELAWN3719Marvin Elevate Awning 1 7' - 0"Existing Second Floor 50ELAWN3719Marvin Elevate Awning 1 7' - 0"Existing Second Floor 51ELAWN3719Marvin Elevate Awning 1 7' - 0"Existing Second Floor 52ELAWN3323Marvin Elevate Awning 1 7' - 0"Existing Second Floor 53ELAWN3323Marvin Elevate Awning 1 7' - 0"Existing Second Floor 54ELCA3363Marvin Elevate Casement 1 7' - 0"Existing Second Floor 55ELCAP4963Marvin Elevate Casement Picture 1 7' - 0"Existing Second Floor 56ELCA3363Marvin Elevate Casement 1 7' - 0"Existing Second Floor 57ELCAP5771Marvin Elevate Casement Picture 1 7' - 0"Existing Second Floor 58ELCA3763Marvin Elevate Casement 1 7' - 0"Existing Second Floor 59ELCAP3771Marvin Elevate Casement Picture 1 7' - 0"Existing Second Floor 60ELCAP4971Marvin Elevate Casement Picture 1 7' - 0"Existing Second Floor 61ELCAP7371Marvin Elevate Casement Picture 1 7' - 0"Existing Second Floor 62ELCAP4971Marvin Elevate Casement Picture 1 7' - 0"Existing Second Floor 63ELCAP5763Marvin Elevate Casement Picture 1 7' - 0"Existing Second Floor Total Windows: 64 REVISION SCHEDULE Number Date Issued by CDRev1 1.18.2023 GM CDRev2 1.24.2023 JCB CDRev3 2.2.2023 GM 1155 SF EXISTING DECK 2318 SF EXISTING MAIN LEVEL 899 SF NEW GARAGE 172 SF FRONT PORCH ADDITION 24 SF STAIR ADDITION 1060 SF EXISTING UPPER LEVEL 2090 SF UPPER LEVEL ADDITION 85 SF EXISTING BALCONY 1/8" = 1'-0" 1Main Level 1/8" = 1'-0" 2Upper Level DRAWN BY DESCRIPTION PROJECT # PROJECT ISSUE RE-ISSUE BUILDER a18476 KENRICK AVE. SUITE #202 LAKEVILLE, MN 55044 TEL: 952.428.8200 EM: Dave@DavidCharlezDesigns.com D A V I D C H A R L E Z D E S I G N SD A V I D C H A R L E Z D E S I G N S Notes: Dimensions, details and conformation to all local codes are to be verified by owner and contractor prior to the start of construction. The designer of the home is not a licensed structural engineer or architect and will assume no responsibility for items including, but not limited to : construction technique, quality of material, workmanship, code adherence, safety, water proofing, insulation, radon, mold/mildew or other designs, specification or construction issues. It is recommended that a licensed engineer review all plans for structural integrity and verify that the home meets code for extraordinary wind or other natural stresses such as flooding, snowfall or substandard bearing soil. All structural members on the plans should be verified by the manufacturer and their licensed engineering staff. Is is also recommended that a licensed contractor be commissioned to construct the home. All door and window size are approximate rough openings. Specific manufacturer sizes vary and egress openings should be confirmed prior to construction. The home should be flashed and enclosed to meet local code. Sizes of material and products reflect accepted industry standards and in no way indicate a specific manufacturer. All building components to be installed and constructed to selected manufacturer specified installation techniques and in accordance with local building codes. Optional items may be shown on the home, within the landscaping/site plan or in the rendering for illustrative purpose only. Consult builder for standard or included features. c David Charlez Designs 2023. Do not replicate with out permission (952)-428-8200. David Charlez Design retains rights to all plans and detail shown. 2/16/2023 3:38:11 PM 17Square Footage Calculations MISC - Beduhn - CD Beduhn Remodel BUILDER BY HOMEOWNER1.12.2022GM 1340 Vine Place Orono, MN S Q. F T G. C A L C S. Name Sq. Ftg.Level Area Type EXISTING MAIN LEVEL 2318 SF Existing First Floor FINISHED SQ. FTG. STAIR ADDITION 24 SF Existing First Floor FINISHED SQ. FTG. EXISTING UPPER LEVEL 1060 SF Existing Second Floor FINISHED SQ. FTG. UPPER LEVEL ADDITION 2090 SF Existing Second Floor FINISHED SQ. FTG. FINISHED SQ. FTG.5492 SF EXISTING DECK 1155 SF Existing First Floor OUTDOOR SQ. FTG. FRONT PORCH ADDITION 172 SF Existing First Floor OUTDOOR SQ. FTG. EXISTING BALCONY 85 SF Existing Second Floor OUTDOOR SQ. FTG. OUTDOOR SQ. FTG.1411 SF NEW GARAGE 899 SF Existing First Floor UNCONDITIONED SQ. FTG. UNCONDITIONED SQ. FTG.899 SF REVISION SCHEDULE Number Date Issued by CDRev1 1.18.2023 GM CDRev2 1.24.2023 JCB CDRev3 2.2.2023 GM