Loading...
HomeMy WebLinkAbout1370 French Creek Dr Orono Inspection24910 Territorial Road, Rogers, Minnesota 55374 • 763-428-4489 info@endeseptic.com • www.endeseptic.com Project: 137o French Creek Dr Orono, MN 55391 A septic compliance inspection was completed on the system, and the system is Compliant according to the MPCA codes for Chapter 708o and local codes for the City of Orono in Hennepin County. The system the following attributes: Date Building Built: 1987 Bedrooms: 5 Date Septic Built: 1987 Septic Tanks: 2 -1000 -gallon septic tanks, manhole cover to grade. Inlet and outlet baffles in place. Pump Tank: l000 -gallon tank, manhole cover to grade. High-level alarm working during inspection. Soil Treatment: Pump fed elevated trench system. 3 trenches around 6o feet in length. Comments: Ende Septic Service, LLC, has been hired to perform a compliance inspection of your ISTS for compliance with local ordinances pursuant to Minn. State. Sec. 155.55 (2010). The compliance inspection covers only the criteria required by Minn. Stat. Sec. 155.55, Subd. 5a (2010 and Minn. R. 7080.1500 (2011). A Compliance inspection is a snapshot in time of your septic system and does not warrant the condition or longevity of your septic system. Ende Septic Service, LLC, disclaims any use of the compliance inspection beyond determining SSTS compliance pursuant to Minn. Stat. Sec. 155.55 (2010). M MINNESOTA POLLUTION Compliance inspection report form CONTROL AGENCY 520 Lafayette Road North Existing Subsurface Sewage Treatment System (SSTS) St. Paul, MN 55155-4194 Doc Type: Compliance and Enforcement Instructions: Inspector must submit completed form to Local Governmental Unit (LGU) and system owner within 15 days of final determination of compliance or noncompliance. Instructions for filling out this form are located on the Minnesota Pollution Control Agency (MPCA) website at https://www.pca.state.mn.us/sites/default/files/wq-wwists4-31a.pdf. Property information Local tracking number: Parcel ID# or Sec/Twp/Range: 1011723320010 Reason for Inspection Transfer of Property Local regulatory authority info: Hennepin County/City of Wayz� Property address: 1370 French Creek Dr. Wayzata, MN 55391 Owner/representative: Andy Berg Owner's phone: 763-258-7133 Brief system description: 2-1000 gallon tanks & 1000 gallon pump tank. Effluent pumped a to an elevated trench system. System status System status on date (mm/dd/yyyy): 4/27/2023 ® Compliant — Certificate of compliance* (Valid for 3 years from report date unless evidence of an imminent threat to public health or safety requiring removal and abatement under section 145A.04, subdivision 8 is discovered or a shorter time frame exists in Local Ordinance.) *Note: Compliance indicates conformance with Minn. R. 7080.1500 as of system status date above and does not guarantee future performance. ❑ Noncompliant — Notice of noncompliance Systems failing to protect ground water must be upgraded, replaced, or use discontinued within the time required by local ordinance. An imminent threat to public health and safety (ITPHS) must be upgraded, replaced, or its use discontinued within ten months of receipt of this notice or within a shorter period if required by local ordinance or under section 145A.04 subdivision 8. Reason(s) for noncompliance (check all applicable) ❑ Impact on public health (Compliance component #1) — Imminent threat to public health and safety ❑ Tank integrity (Compliance component #2) — Failing to protect groundwater ❑ Other Compliance Conditions (Compliance component #3) — Imminent threat to public health and safety ❑ Other Compliance Conditions (Compliance component #3) — Failing to protect groundwater ❑ System not abandoned according to Minn. R. 7080.2500 (Compliance component #3) — Failing to protect groundwater ❑ Soil separation (Compliance component #5) — Failing to protect groundwater ❑ Operating permit/monitoring plan requirements (Compliance component #4) — Noncompliant - local ordinance applies Comments or recommendations Certification I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of future system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate maintenance, or future water usage. By typing my name below, I certify the above statements to be true and correct, to the best of my knowledge, and that this information can be used for the purpose of processing this form. Business name: Ende Septic Service Certification number: L2654 Inspector signature: Tristan Ende �� �_ License number: C9206 (This document has been electronically signed) Phone: 763-428-4489 Necessary or locally required supporting documentation (must be attached) ® Soil observation logs ® System/As-Built ❑ Locally required forms ❑ Tank Integrity Assessment ❑ Operating Permit ❑ Other information (list): https://www.pca.state.mn.us 651-296-6300 800-657-3864 Use your preferred relay service Available in alternative formats wq-wwists4-31b • 4/28/2021 Page 1 of 4 Property Address: 1370 French Creek Dr. Wayzata, MN 55391 Business Name: Ende Septic Service 1. Impact on public health — Compliance component #1 of 5 Compliance criteria: System discharges sewage to the [:]Yes* ® No ground surface System discharges sewage to drain ❑ Yes" ® No tile or surface waters. System causes sewage backup into ❑ Yes" ® No dwelling or establishment. Any "yes" answer above indicates the system is an imminent threat to public health and safety. Describe verification methods and results: searched for seeping near trenches. Nothing found Date: 4/27/2023 Attached supporting documentation: ❑ Other: ❑ Not applicable 2. Tank integrity — Compliance component #2 of 5 Compliance criteria: System consists of a seepage pit, cesspool, drywell, leaching pit, or other pit? Sewage tank(s) leak below their designed operating depth? Attached supporting documentation: [:]Yes* ® No ❑ Empty tank(s) viewed by inspector [-]Yes* ® No If yes, which sewage tank(s) leaks: Any "yes" answer above indicates the system is failing to protect groundwater. Describe verification methods and results: See attached tank integrity from Duane's Septic Service Name of maintenance business: License number of maintenance business: Date of maintenance: ® Existing tank integrity assessment (Attach) Date of maintenance 5/1/2023 (mm/dd/yyyy): (must be within three years) (See form instructions to ensure assessment complies with Minn. R. 7082.0700 subp. 4 8 (1)) ❑ Tank is Noncompliant (pumping not necessary — explain below) ❑ Other: https://www.pca.state.mn.us 651-296-6300 800-657-3864 Use your preferred relay service Available in alternative formats wq-wwists4-31b • 4/28/2021 Page 2 of 4 Property Address: 1370 French Creek Dr. Wayzata, MN 55391 Business Name: Ende Septic Service Date: 4/27/2023 3. Other compliance conditions — Compliance component #3 of 5 3a. Maintenance hole covers appear to be structurally unsound (damaged, cracked, etc.), or unsecured? ❑ Yes* E No ❑ Unknown 3b. Other issues (electrical hazards, etc.) to immediately and adversely impact public health or safety? ❑ Yes* ® No ❑ Unknown "Yes to 3a or 3b - System is an imminent threat to public health and safety. 3c. System is non -protective of ground water for other conditions as determined by inspector? ❑ Yes* ® No 3d. System not abandoned in accordance with Minn. R. 7080.2500? ❑ Yes* ® No *Yes to 3c or 3d - System is failing to protect groundwater. Describe verification methods and results: Attached supporting documentation: ❑ Not applicable ❑ 4. Operating permit and nitrogen BMP* — Compliance component #4 of 5 ® Not applicable Is the system operated under an Operating Permit? ❑ Yes ❑ No If "yes", A below is required Is the system required to employ a Nitrogen BMP specified in the system design? ❑ Yes ❑ No If "yes", B below is required BMP = Best Management Practice(s) specified in the system design If the answer to both questions is "no", this section does not need to be completed. Compliance criteria: a. Have the operating permit requirements been met? ❑ Yes ❑ No b. Is the required nitrogen BMP in place and properly functioning? ❑ Yes ❑ No Any "no" answer indicates noncompliance. Describe verification methods and results: Attached supporting documentation: ❑ Operating permit (Attach) ❑ https://www.pca.state.mn.us 651-296-6300 800-657-3864 Use your preferred relay service Available in alternative formats wq-wwists4-31b • 4/28/2021 Page 3 of 4 Property Address: 1370 French Creek Dr. Wayzata, MN 55391 Business Name: Ende Septic Service 5. Soil separation — Compliance component #5 of 5 Date of installation 8/5/1987 ❑ Unknown (mm/dd/yyyy) Shoreland/Wellhead protection/Food beverage lodging? Hance criteria (select one): 5a. For systems built prior to April 1, 1996, and not located in Shoreland or Wellhead Protection Area or not serving a food, beverage or lodging establishment: Drainfield has at least a two -foot vertical separation distance from periodically saturated soil or bedrock. 5b. Non-performance systems built April 1, 1996, or later or for non- performance systems located in Shoreland or Wellhead Protection Areas or serving a food, beverage, or lodging establishment: Drainfield has a three-foot vertical separation distance from periodically saturated soil or bedrock.* 5c. `Experimental, "Other", or "Performance" systems built under pre -2008 Rules; Type IV or V systems built under 2008 Rules 7080. 2350 or 7080.2400 (Intermediate Inspector License required <_ 2,500 gallons per day; Advanced Inspector License required > 2,500 gallons per day) Drainfield meets the designed vertical separation distance from periodically saturated soil or bedrock. Date: 4/27/2023 ❑ Yes ® No Attached supporting documentation: ❑ Soil observation logs completed for the report ❑ Two previous verifications of required vertical separation ® Yes ❑No* ❑Not applicable (No soil treatment area) ❑ Yes ❑ No* Indicate depths or elevations A. Bottom of distribution media 30" B. Periodically saturated soil/bedrock 60" C. System separation 30" D. Required compliance separation* 24" *May be reduced up to 15 percent if allowed by Local Ordinance. ❑ Yes ❑ No* *Any "no" answer above indicates the system is failing to protect groundwater. Describe verification methods and results: boring taken west of trenches Upgrade requirements: (Minn. Stat. § 115.55) An imminent threat to public health and safety (ITPHS) must be upgraded, replaced, or its use discontinued within ten months of receipt of this notice or within a shorter period if required by local ordinance. If the system is failing to protect ground water, the system must be upgraded, replaced, or its use discontinued within the time required by local ordinance. If an existing system is not failing as defined in law, and has at least two feet of design soil separation, then the system need not be upgraded, repaired, replaced, or its use discontinued, notwithstanding any local ordinance that is more strict. This provision does not apply to systems in shoreland areas, Wellhead Protection Areas, or those used in connection with food, beverage, and lodging establishments as defined in law. https://www.pca.state.mn.us 651-296-6300 800-657-3864 Use your preferred relay service Available in alternative formats wq-wwists4-31b • 4/28/2021 Page 4 of 4 MINNESOTA. POI LUTION CONTROL AGENCY 520 Lafayette Road North St. Paul, MN 55155-4194 Property address: l'-- F—i Sewage tank integrity assessment form C r db rr1 City: 0 r- V -t. G State: Subsurface Sewage Treatment Systems (SSTS) Program Parcel ID: Zip code: Purpose: This form may be used to certify the compliance status of the sewage tank components of the SSTS. This form is not a complete SSTS inspection report, only a tank integrity assessment, and may only certify sewage tank compliance status when entirely completed and signed by a qualified professional. SSTS compliance inspection report forms can be found at: ii?ti�S://lywVd. ca. state,mn_i.,shrvatel/iiispectio s. Instructions: This form may be completed, and signed, by a Designated Certified Individual (DCI) of a licensed SSTS inspection, maintenance, installation, or service provider business who personally conducts the necessary procedures to assess the compliance status of each sewage tank in the system. A copy of this information should be submitted to the system owner and be maintained by the licensed SSTS business for a period of five (5) years from the assessment date. When this form is signed by a qualified certified professional, it becomes necessary supporting documentation to an Existing System Compliance Inspection Report: Cp;r,#a saf;ce n pec ior? COMD— xi;t'L-Cu sYst—ers (,,;q_,;:.+;,; s? .--ul ,;. This form can be found on the MPCA website at t;ttps %1;�„��oc;sat. <:,n Lslr.,a.r(ns ctip . The information and certified statement on this form is required when existing septic tank compliance status is determined by an individual other than the SSTS Inspector that submits an inspection report. This form represents a third party assessment of SSTS component compliance and is allowable under Minn. R. 7082.0700, subp. 4 Item (B) subitem (1). This form is valid for a period of three years beyond the signature date on this form unless a new evaluation is requested by the owner or owner's agent or is required according to local regulations. Additional Administrative Rule references for this activity can be found at Minn. R. 7082.0700, subp. 4 Items B, C, and D; 7083.0730 Item C. Z'c:ertificate of sewage tank compliance Affirm allAhree statements: Ef The SSTS does not contain a seepage pit, cesspool, d�Qwell, leaching pit, or other pit. E�Ilt does not contain a sewage tank that was designed to be watertight, but subsequently leaks below the signed operating depth. It does not represent an imminent safety threat by reason of unsecured, damaged, or weak maintenance hole cover(s) or other unsafe condition. Company information :Company name: Duane's Septic Service Business license number: 654 ❑ Notice of sewage tank non-compliance Select all that apply: ❑ The SSTS has a seepage pit, cesspool, drywell, leaching pit, or other pit - "Failure to Protect Groundwater." ❑ It has a sewage tank that was designed to be watertight, but subsequently leaks below the designed operating depth - "Failure to Protect Groundwater." ❑ It presents a threat to public safety by reason of unsecured, damaged, or weak maintenance hole cover(s) or other unsafe condition - w"Imminent Threat to Public Health or Safety." Designated Certified Individual (DCQ information Print name:.�---- Certification number: C 9- t -7 I personally conducted the work described above as a Designated Certified Individual of a Minnesota -licensed SSTS inspection, maintenance, installation, or service provider Business. I personally conducted the necessary procedures to assess the compliance status of each sewage tank in this SSTS. By typing/signing my name below, I certify the above statements to be true and correct, to the best of my knowledge, and that this information can be used fo the purpose of processing this form. Designated Certified Individual's signature: Date (mm/dd/yyyy): 05- 12-,j ;�,3 documen has een electronically signed.) Ir www.pca.state.mn.us 651-296-6300 800-657-3864 Use your preferred relay service • Available in alternative formats wq-wwists4-91 • 1/5/21 Page 1 of 1 Field Copy Soil Profile Description Last updated: 1/8/10 Date Completed : 5/3/2023 Completed By: Ende Septic Service Client / Project : 1370 French Creek Dr Orono, NIN LOT# Mapped soil type: Outwash Observation # : sb 1 and sb2 Equipment: bucket auger Limiting Layer: 6011+ Vegetation : grassy Weather : Sunny Observation # 1 Elevation: Horizon Depth Soil Texture Matrix Color Redox features Shape Grade Consistence 0-12 loamy sand 10YR3/3 single grain loose loose 12 to 24 sandy loam 10YR3/6 granular weak friable 24-38 loamy sand 10YR3/6 single grain loose loose 38-60 med-fine sand 10YR4/6 single grain loose loose Observation # 2 Elevation: Horizon Depth Soil Texture Matrix Color Redox features Shape Grade Consistence Ende Septic Service, LLC, 24910 Territorial Road, Rogers, NIN 55374 j2Ga �nc�� Phone: (763) 428-4489 info@endeseptic.com www.endeseptic.com Hennepin County Property Map Date: 5/3/2023 sbl 1 inch = 50 feet W!"1W_ PARCEL ID: 1011723320010 OWNER NAME: Andrew B Berg/Julia M Berg PARCEL ADDRESS: 1370 French Creek Dr,Orono MN 55391 PARCEL AREA: 1.49 acres, 65,110 sq ft A -T -B: Torrens SALE PRICE: $1,125,000 SALE DATE: 06/2020 SALE CODE: Warranty Deed ASSESSED 2022, PAYABLE 2023 PROPERTY TYPE: Residential HOMESTEAD: Homestead MARKET VALUE: $1,376,000 TAX TOTAL: $15,039.88 ASSESSED 2023, PAYABLE 2024 PROPERTY TYPE: Residential HOMESTEAD: Homestead MARKET VALUE: $1,535,200 Comments: �2L6tCc+L �'N�2 This data (i) is furnished 'AS IS' with no representation as to completeness or accuracy; (ii) is furnished with no warranty of any kind; and (iii) is not suitable for legal, engineering or surveying purposes. Hennepin County shall not be liable for any damage, injury or loss resulting from this data COPYRIGHT © HENNEPIN COUNTY 2023