HomeMy WebLinkAbout4/27/23 Septic Compliance Inspection - Non Compliant1 MINNESOTA POLLUTION Compliance ins ection report form
CONTROL AGENCY p
520 Lafayette Road North Existing Subsurface Sewage Treatment System (SSTS)
5t. Paul, MN 55155-4194 Doc Type: Compliance and Enforcement
Instructions: Inspector must submit completed form to Local Governmental Unit (LGU) and system owner within 15 days of
final determination of compliance or noncompliance. Instructions for filling out this form are located on the Minnesota Pollution
Control Agency (MPCA) website at httos://www.pca.state.mn.us/sites/default/files/wa-wwists4-31a.pdf.
Property Information Local tracking number:
Parcel ID# or Sec/Twp/Range: 0311723230022 Reason for Inspection Property Transfer
Local regulatory authority info: _City Of Orono, (952) 249-4600
Property address: 2325 Willow Hill Drive, Orono
Owner/representative: GreggLarsen Owner's phone: 612-810-5345
Brief system description: 2-1300-gallon septic tanks, 1-1300-gallon lift station and 630 Square feet Rock bed
System status
System status on date (mm/dd/yyyy): 4/27/2023
❑ Compliant — Certificate of compliance*
(Valid for 3 years from report date unless evidence of an
imminent threat to public health or safety requiring removal and
abatement under section 145A. 04, subdivision 8 is discovered or
a shorter time frame exists in Local Ordinance.)
*Note: Compliance indicates conformance with Minn.
R. 7080.1500 as of system status date above and does not
guarantee future performance.
® Noncompliant — Notice of noncompliance
Systems failing to protect ground water must be upgraded, replaced, or
use discontinued within the time required by local ordinance.
An imminent threat to public health and safety (ITPHS) must be
upgraded, replaced, or its use discontinued within ten months of receipt
of this notice or within a shorter period if required by local ordinance or
under section 145A.04 subdivision 8.
Reason(s) for noncompliance (check all applicable)
❑ Impact on public health (Compliance component #1) — Imminent threat to public health and safety
❑ Tank integrity (Compliance component #2) — Failing to protect groundwater
❑ Other Compliance Conditions (Compliance component #3) — Imminent threat to public health and safety
❑ Other Compliance Conditions (Compliance component #f3) — Failing to protect groundwater
❑ System not abandoned according to Minn. R. 7080.2500 (Compliance component #3) — Failing to protect groundwater
® Soil separation (Compliance component #5) — Failing to protect groundwater
❑ Operating permit/monitoring plan requirements (Compliance component #4) — Noncompliant - local ordinance applies
Comments or recommendations
The system is designed for a five bedroom house.
There is 1.0 feet of sand under the rock bed.
The system is not an Imminent threat to public health. The rock bed would need to be raised with sand approximately 12 inches
to be compliant..
Certification
1 hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of
future system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system,
inadequate maintenance, or future water usage.
By typing my name below, 1 certify the above statements to be true and correct, to the best of my knowledge, and that this information can be
used for the purpose of processing this form.
Business name: Rusty Olson Soil & percolation Testing_ Certification number: C1255
Inspector signature: Joseph J. Olson License number: L810
(This document has been electronically signed) Phone: 763-498-8779
Necessary or locally required supporting documentation (must be attached)
® Soil observation logs ® System/As-Built ❑ Locally required forms ® Tank Integrity Assessment ❑ Operating Permit
❑ Other information (list):
https://www.pca.state.mn.us 651-296-6300 800-657-3864 Use your preferred relay service Available in alternative formats
wq-wwists4-31b • 4/28/2021 Page 1 of 4
Property Address: 2325 Willow Hill Drive, Orono
Business Name: Rusty Olson Soil & percolation Testing Date: 4/27/2023
1. Impact on public health -- Compliance component #1 of 5
Compliance criteria:
System discharges sewage to the ❑ Yes" ® No
ground surface
System discharges sewage to drain i ❑ Yes* ®No
tile or surface waters.
System causes sewage backup into ❑ Yes* ® No
dwelling or establishment.
Any "yes" answer above indicates the system is an
imminent threat to public health and safety.
Describe verification methods and results:
Visual. Nothing was found
Attached supporting documentation:
❑ Other:
® Not applicable
2. Tank integrity — Compliance component #2 of 5
Comlian
System consists of a seepage pit, [:]Yes* ® No
cesspool, drywell, leaching pit,
or other pit?
Sewage tank(s) leak below their ❑ Yes* ® No
designed operating depth?
If ves, which sewaae to
Any "yes" answer above indicates the system
is failing to protect groundwater.
Describe verification methods and results:
Elmer J Peterson Company pumped the tanks.
Attached supporting documentation:
❑ Empty tank(s) viewed by inspector
Name of maintenance business:
License number of maintenance business:
Date of maintenance:
® Existing tank integrity assessment (Attach)
Date of maintenance 2/8/2023
(mmlddlyyyy): (must be within three years)
(See form instructions to ensure assessment complies with
Minn. R. 7082.0700 subp. 4 B (1))
❑ Tank is Noncompliant (pumping not necessary -explain below)
❑ Other:
https://www.pca.state.mn.us 651-296-6300 800-657-3864 use your preferred relay service • Available in alternative formats
wq-wwists4.31b • 412812021 Page 2 of 4
Property Address: 2325 Willow Hill Drive, Orono
Business Name: Rusty Olson Soil & percolation Testing Date: 4/27/2023
3. Other compliance conditions — Compliance component #3 of 5
3a. Maintenance hole covers appear to be structurally unsound (damaged, cracked, etc.), or unsecured?
[:]Yes* ® No ❑ Unknown
3b. Other issues (electrical hazards, etc.) to immediately and adversely impact public health or safety? ❑ Yes" ® No ❑ Unknown
*Yes to 3a or 3b - System is an imminent threat to public health and safety.
3c. System is non -protective of ground water for other conditions as determined by inspector? ❑ Yes* ® No
3d. System not abandoned in accordance with Minn. R. 7080.2500? ❑ Yes` ® No
*Yes to 3c or 3d - System is failing to protect groundwater.
Describe verification methods and results:
Visual. Nothing was found
Attached supporting documentation: ® Not applicable ❑
4. Operating permit and nitrogen BMP* — Compliance component #4 of 5 ® Not applicable
Is the system operated under an Operating Permit? ❑ Yes ❑ No If "yes", A below is required
Is the system required to employ a Nitrogen BMP specified in the system design? ❑ Yes ❑ No If "yes", B below is required
BMP = Best Management Practices) specified in the system design
If the answer to both questions is "no'; this section does not need to be completed.
Compliance criteria:
a. Have the operating permit requirements been met? ❑ Yes ❑ No
b. is the required nitrogen BMP in place and properly functioning? ❑ Yes ❑ No
Any "no" answer indicates noncompliance.
Describe verification methods and results:
Attached supporting documentation: ❑ Operating permit (Attach) ❑
https:Ilwww.pca.state, mn.us 651-296-6300 800-657-3864 • Use your preferred relay service Available in alternative formats
wq-wwists4-316 • 412812021
Page 3 of 4
Property Address: 2325 Willow Hill Drive, Orono
Business Name: Rusty Olson Soil & percolation Testing
Date: 4/27/2023
5. Soil separation — Compliance component #5 of 5
Date of installation
(mm/dd/yyyy)
Shoreland/Wellhead protection/Food
beverage lodging?
criteria (select one):
5a. For systems built prior to April 1, 1996, and
not located in Shoreland or Wellhead
Protection Area or not serving a food,
beverage or lodging establishment:
Drainfield has at least a two -foot vertical
separation distance from periodically
saturated soil or bedrock.
5b. Non-perfonnance systems built
April 1, 1996, or later or for non-
performance systems located in Shoreland
or Wellhead Protection Areas or serving a
food, beverage, or lodging establishment:
Drainfield has a three-foot vertical
separation distance from periodically
saturated soil or bedrock.*
5c. "Experimental", "Other", or "Performance"
systems built under pre-2008 Rules;
Type IV or V systems built under 2008
Rules 7080. 2350 or 7080,2400
(intermediate Inspector License required 5
2,500 gallons per day; Advanced Inspector
License required > 2,500 gallons per day)
Drainfield meets the designed vertical
separation distance from periodically
saturated soil or bedrock.
® Unknown
❑ Yes ® No
❑ Yes [:]No*
❑ Yes ® No*
❑ Yes ❑ No*
*Any "no" answer above indicates the system is
failing to protect groundwater.
Describe verification methods and results:
Soil borings
Attached supporting documentation:
® Soil observation logs completed for the report
❑ Two previous verifications of required vertical separation
❑ Not applicable (No soil treatment area)
Indicate depths or elevations
A. Bottom of distribution media
94.9
B. Periodically saturated soil/bedrock
96.6
C. System separation
2.3
D. Required compliance separation*
2.55
*May be reduced up to 15 percent if allowed by Local
Ordinance.
Upgrade requirements: (Minn. Stat. § 115.55) An imminent threat to public health and safety (ITPHS) must be upgraded, replaced,
or its use discontinued within ten months of receipt of this notice or within a shorter period if required by local ordinance. If the
system is failing to protect ground water, the system must be upgraded, replaced, or its use discontinued within the time required by
local ordinance. If an existing system is not failing as defined in law, and has at least two feet of design soil separation, then the
system need not be upgraded, repaired, replaced, or its use discontinued, notwithstanding any local ordinance that is more strict.
This provision does not apply to systems in shoreland areas, Wellhead Protection Areas, or those used in connection with food,
beverage, and lodging establishments as defined in law.
https://www.pca.state.mn.us 651-296-6300 800-657-3864 Use your preferred relay service Available in alternative formats
wq-wwi5t54-31b • 412812021 Page 4 of 4
Tank Report
Elmer J. Peterson Co.
592 1 Dague Ave_
Delano, MN 55328
Phone 763-9 72-2+20
Fax 763-9 7 2- 71l 17
MPCA License# 219
Bill Guidera
2325 Willow Hill Drive
Orono, MN
612-719-4477 Gregg Larsen - Realtor
Baffles: O 1 OFF
Tank Capacity: 3-1300 Gallon Tanks
# of Tanks: 3
Type ofTanks:
Gallons Pumped:
Concrete
3500
Manholes to Grave: DEIS
/ NO
Comments:
Date -,February 8 2023
On February 8, 2023, Elmer J. Peterson Co. pumped septic tanks and cleaned filter in 2"'tank. No cracks or
water leaking in tanks at the time of pumping.
NOTE: This is only a tank report. This is not a compliance inspection for point of'sale nor does it
replace a compliance inspection.
M MINNESOTA POLLUTION Sewage tank inte rit assessment form
CONTROL AGENCY Y
520 Lafayette Road north Subsurface Sewage
5t. Paul, MN 55155-4194 Treatment Systems (SSTS) Program
Doc Type: Compliance and Enforcement
Purpose: This form may be used to certify the compliance status of the sewage tank components of the SSTS. This form is not a
complete SSTS inspection report, only a tank integrity assessment, and may only certify sewage tank compliance status
when entirely completed and signed by a qualified professional. SSTS compliance inspection report forms can be found at:
https://www.gca.state.mn us/waterline ections.
Instructions: This form may be completed, and signed, by a Designated Certified Individual (DCI) of a licensed SSTS inspection,
maintenance, installation, or service provider business who personally conducts the necessary procedures to assess the compliance
status of each sewage tank in the system. Only a licensed maintenance business is authorized to pump the tank for assessment. A
copy of this information should be submitted to the system owner and be maintained by the licensed SSTS business for a period of
five (5) years from the assessment date.
When this form is signed by a qualified certified professional, it becomes necessary supporting documentation to an Existing
System Compliance Inspection Report: Compliance inspection form - Existing system w-wwists4.31 b). This form can be found on
the MPCA website at hftps.,i/www.1)ca.slate.mn.us/water/insgections-
The information and certified statement on this form is required when existing septic tank compliance status is determined by an
individual other than the SSTS Inspector that submits an inspection report. This form represents a third party assessment of SSTS
component compliance and is allowable under Minn. R. 7082.0700, subp. 4(13)(1). This form is valid for a period of three years
beyond the signature dater on this form unless a new evaluation is requested by the owner or owners agent or is required according
to local regulations. Additional Administrative Rule references for this activity can be found at Minn. R, 7082.070e, subp. 4(8),(C),
and (D) and; Minn. R. 7083.0730(C).
Owner information
Owner/Representative _Bill Guidera
Property address: 2325 Willow Hit] Drive Orono, MN
Local Regulatory Authority: Parcel ID:
System status
System status on date (mm/dd/yyyy): 2/8/2023
® Certificate of sewage tank compliance ❑ Notice of sewage tank non-compliance
Compliance criteria:
The SSTS has a seepage pit, cesspool, drywell, leaching pit, or other pit - "Failure to Protect
Groundwater." ❑ Yes- H No
The SSTS has a sewage tank that leaks below the designed operating depth - 'Failure to Protect
Groundwater." ❑ Yes` ® No
The SSTS presents a threat to public safety by reason of structurally unsound (damaged, cracked..
or weak) maintenance hole cover(s) or lids or any other unsafe condition - "Imminent Threat to ❑ Yes` ® No
Public Health or Safety."
Any "yes" answer above indicates sewage tank non-compliance.
Company information Designated Certified Individual (DCI) information
Company name: Elmer J. Peterson Co Print name: James L Braegelmann
Business license number: 219 Certification number:
i personally conducted the work described above as a Designated Certified Individual of a Minnesota -licensed SSTS inspection
maintenance, installation, or service provider Business. I personally conducted the necessary procedures to assess the compliance
status of each sewage tank in this SS TS.
By typinglsigning my name below, l certify the above statements to be true and correct, to the best of my knowledge, and that
this information can be used for the purpose of processing this form.
Designated Certified Individual's signature: James L Braegelmann _ _ Date (mm/dd/yyyy): 2/8/2023
(This document has been electronically signed.)
www.pcastate.mn.us • 651-296-63Ro 800-657-3864 • Use your preferred relay service Available in alternative for-nats
wq-wwists4-91 • 5110121
Page I of I
Soil Observation Log
www.SepticResource.com vers 12.4
Owner Information
Owner / project: Date 1 /27/2023
Address I PID: 2325 Willow Hill Drive
Soil Survey Information ❑ refer to attached soil survey
Parent matl's: D Till ❑ Outwash ❑ Lacustrine ❑ Alluvium ❑ Organic ❑ Bedrock
landscape position: 21 Summit ❑ Shoulder ❑ Side slope ❑ Toe slope
soil survey map units: L22C;2 slope % direction -
Soil Log 41
E Boring El Fit Elevation 97.3 Depth to SHWT 58 inches
Depth (in) Texture fragment % matrix color redox color consistence grade shape
0-42
Fill mound sand
<35
42-52
Loam
<35
1Oyr3/l
Friable
Strong
Blocky
52-58
Clay Loam
<35
10yr4/3
Friable
Strong
Blocky
58-66
Clay Loam
<35
10yr5/4
IGy4/8,1-6/l0y
Firm
Strong
Blocky
<35
loose
loose
single grain
35-50
friable
weak
granular blocky
>50
firm
moderate
prismatic platy
rigid
strong
mmive
Comments: TBM: Top of garage slab. EL-100.0
2325 Willow Hill Drive Soil Log 42
0 Boring ❑ Pit Elevation 96.4 Depth to SHWT 42 inches
Depth (in) Texture fragment % matrix color redox color consistence grade shape
0-27
Fill mound sand
<35
27-36
Loarn
<35
10yr3/1
Friable
Strong
Blocky
36-42
Clay Loam
<35
1 Oyr4/3
Friable
Strong
Blocky
42-52
Clay Loam
<35
10yr5/4
IQy4/8,1-6/10y
Firm
Strong
stocky
<'S
loose
loose
single grain
35 50
friable
weak
granular blocky
firth
moderate
Prismatic platy
>50
rigid
strong
massive
2325 Willow Hill Drive Soil Log #3
p Boring ❑ Pit Elevation Depth to SHWT
Depth (in) Texture fragment % matrix color redox color consistence grade shape
<35
loose
loose
single grain
35 - 50
friable
weak
granular blocky
firm
moderate
prismatic platy
>50
rigid
strong
massive
<35
loose
loose
single grain
35 - 50
friable
weak
granular blocky
firm
moderate
prismatic platy
>50
rigid
strong
massive
<35
loose
loose
single grain
35 - 50
friable
weak
granular blocky
>50
fum
moderate
prismatic platy
rigid
strong
massive
<35
loose
loose
single grain
35-50
friable
weak
granular blocky
>50
firm
moderate
prismatic platy
rigid
strong
massive
<35
loose
loose
single grain
35 - 50
friable
weak
granular blocky
>50
firm
moderate
prismatic platy
rigid
I strong
massive
I hereby certi this work was completed in accordance with MN 7080 and any local req's.
i' Rusty Olson's Soil & Perc 810
esigner Signature Company License #
V