Loading...
HomeMy WebLinkAbout06-29-2021 Septic Maintenance Report Septic Check ► 6074 Keystone Rd p t D'• 35 l l Q p 1343 O03 4 320-983.2447 Milaca,MN 56353 Fax:320-983-2151 e-PROPERTY INFORMATION Brian Palmer Location:1190 Lyman Ave Orono Tax ID:35-118-23-43-0 Mail re: Brian Palmer 1190 Lyman Ave Use:Residential,Single Family Orono,MN System Design Flow:600 55391 GENERAL SYSTEM TYPE:STAND Res 1 NO TEST Fold , ON-SITE WASTEWATER TREATMENT SYSTEM INSPECTION REPORT Fold Here Here Inspected:06/29/2021 - Inspection Type:ROUTINE - Correction Status:No corrections needed Company: Work Performed By: Submitted 07/01/2021 by: Septic Check Michael Pederson Heather Johnson COMMENTS&GENERAL INSPECTION NOTES No Deficiencies Noted Everything looks great and is working properly. Have a great day! GENERAL SITE&SYSTEM CONDITIONS The General Site and System Conditions were: Fully Inspected Components accessible for service: YES All required service performed(if no-specify omitted inspection items in notes): YES Surfacing effluent from any component(including mound seepage): NO Components appear to be watertight-no visual leaks: YES Improper encroachment(structures/impervious surfaces);cover,or settling problems observed: NO ONSITE SEWAGE SYSTEM INSPECTION DETAIL TANK:Septic Tank-1 Compartment,Manufacturer= Local Manufacturer-Concrete Septic Tank#1-1,500 Gallon Manufacturer: Local Manufacturer Model:Concrete This component was: Fully Inspected Effluent level within operational limits(if NO explain in comments): YES All required baffles in place(N/A=No baffles required): YES Compartment 1 Scum accumulation(Inches,if other specify): 1 Compartment 1 Sludge accumulation(Inches,if other specify): 4 Pumping recommended: NO Ift Wt; tatrI IEN •ri••l fl'f M117101471l'1=1111:1"1111rr!�- 110741= 't11• tfO :frke!"iNdelrlef I•► Manufacturer: Local Manufacturer Model:Concrete This component was: Fully Inspected Effluent level within operational limits(if NO explain in comments): YES All required baffles in place(N/A=No baffles required): YES Compartment 1 Scum accumulation(Inches,if other specify): 0 Compartment 1 Sludge accumulation(Inches,if other specify): 0 Pumping recommended: NO TANK:Pump Tank,Manufacturer= Local Manufacturer-Concrete Pump Tank-1000 Gallons Manufacturer: Local Manufacturer Model:Concrete 'This component was: Fully Inspected Compartment 1 Scum accumulation(Inches,if other specify): fl Compartment 1 Sludge accumulation(Inches,if other specify): 2 Pumping recommended: NO Pump:Effluent Pump Biotube Pump Vault Manufacturer:Orenco This component was: Fully Inspected Controls functioning: YES Tested gallons per minute flow: NA ReportlD:975869 View inspection reports online at www.onlinerme.com Page 1 of 2 •ane1:Control-1 Pump Control Panel This component was: Fully Inspected Panel functioning(including alarm): YES Pump 1:on minutes(override in parentheses-if present): 2.3 Pump 1:off hours(override in parentheses-if present): 4 Pump 1:gallons per dose(override in parentheses-if present): NA Pump 1:ETM hours(override in parentheses-if present): 156.0 Pump 1:Cycle Count(override in parentheses-if present): 5233 rain field(disposal):Pressure Mound-10'x 50'Rockbed This component was: Fully Inspected Lateral lines flushed: NO Average squirt height(if performed)(feet,if other specify): NA Ponding present?If YES explain in comments: NO • This report indicates certain characteristics of the onsite sewage system at the time of visit.In no way is this report a guarantee of operation or future performance. ReportlD:975869 View inspection reports online at www.onlinerme.com Page 2 of 2 SAMPLING REPORT Location:1190 Lyman Ave Service Company: Orono Septic Check 35-118-23-43-0034 6074 Keystone Rd Owner:Brian Palmer Milaca,MN 56353 use:Single Family 320-983-2447 Sample Date:06/29/2021 Sample entered by: Heather Johnson Report submitted:07/02/2021 Notes: ONS1TE SEWAGE SYSTEM SAMPLING DETAIL COMPONENT TYPE SAMPLE LIMIT RESULT Control-1 Pump Control Panel Effluent FLOW 600 GPD 90.6 This report indicates certain characteristics of the sample taken at the time of visit.In no way is this report a guarantee of operation or future performance. Report ID:9878 View sample reports online at www.onlinerme.com Page 1 of 1