Loading...
HomeMy WebLinkAboutLtr re expansion � �`'°� Cit of Orono 0 o Y ���=>��. 2750 Kelley Parkway � � �'�� � P.O. Box 66 .��_� �. �K�''� .'� +��, G� Crystal Bay, MN 55323 ��,lr .-��w�� �A�Ho� (952) 249-4600 Fax: (952) 249-4616 Date: August 10, 2010 To: Greg Hatch and Brian Monette From: Evelyn Turner 952-249-4623 eturner@ci.orono.mn.us Subject: 350 Big Island Although the minimum lot size on Big Island is 5 acres the property has a permanent lot area variance so the size of the lot is not an issue. Setbacks are as follows: Lake 75 ' Side 10' Rear(street) 30' Hardcover limitations: 0-75' from lake—no hardcover 75-250'—25% of that area 250-500' -30% of that area Maximum structural coverage: 15% of entire lot(included in structural coverage is any building or structure over six feet high) Maximum building height: two stories plus a defined half-story and 30 feet of defined height. Septic System: Installed in 2009 and designed for seasonal use only for three bedrooms. Layout of system attached. Expansion Issues: Setback—Viewed from the lake the right hand side wall of the cabin has a 1.4 foot setback from the adjacent property line at the back corner and 2.4 feet at the front corner. The steps encroach onto the neighboring property. (Based on an August, 2009 survey by Sathre-Bergquist, Inc. of the adjacent property, partial copy attached.) Any expansion upward or to the front or rear would have to meet the 10 foot setback. Floodplain—The survey includes some spot elevations that suggest the area where the cabin is floodplain (at or below 931.5). A horizontal addition would have to have a minimum first floor elevation of 932.5 with no mechanical equipment or ductwork located below this elevation. If value of the addition exceeded 50 percent of the value of the cabin as it exists now, the whole cabin would have to be elevated. Unless it is possible to enlarge the floodplain elsewhere on the property to compensate for filling to elevate the cabin, it would have to be placed on post footings or a floodable crawlspace. Rebuild as it-While state statutes allow replacement in kind of dwellings that do not comply with local zoning requirements, the replacement must comply with the FEMA floodplain regulations. Every effort has been made to insure the accuracy of the information contained herein;however, if any information is not consistent with provisions of the City Code, the Code provisions will prevail. f 1 � IV ,�y�\ .� �� �- � � � � ..�, �- ' g15 , e'� \ ,�,��, Gk�ea� �\, ^' ►, _ ��i � �10` x25 � Elevation S t�ina� ,, \ ' �� ' a�°� g p�� �, Main Floor � �a���� - Q\� '� Lowest Floar p ��•, "� �a . Enter Tank 98.0' � � �a4� � \� Pump 93.0' r `�Manifold 113.0' Absorption are � ���\g � �� �, � , ,\ r" �a4�e \ .\ Note: � � Upslope is 1:4 � Ofl01 � . Downslope is 1:3 �� � � � , A retainin wall instailed below fhe� bso tio ����� oo�l '• � � � area would shorten the downslope.�'� Q`��� ,�a���� ��001 �'� 't�t' ,��� � \ � GJ�'Q G'�a '�p � �P�Q�` O� �`\ , �0 \ \ • ----=, -Wa��p�-- ---�i-- --- '�� � . - � � � e � .\ �0�.5 � _ Desi,gn� � Jim Spieker � � 94226 Ash Circle N.E. � Prior Lake, M�V 55372 '� tel. 952-445-8569 MPCA lic.# 501 � � ,\ / / � �� / / / / — — — — � — — — — — NOtIIOaV ONZ N�lVd ONY'1SI 3SMpY1 '£10'I d0 3N�1,l'Rl3L53MHLf10S- / �� - - - - - - - - - - - -,.�-- - - - � , i��� i ► , �b��°��' / i i � � ��o�� J, �� � i � ' . , / �,� ^�� J� � , �, e9,� ��j� r-�° � q g !i I �6 Y / '�� � `���' / � b'�1 I �� I � . ,� ��3' C'. � ' , 9/, 6 ''�'� �63�''� �,�� (`j� . � , 1�l'J �' � �� aNz Nava armsi 3saow 'r io��o i�000s I ' �6 �'/ y � / AWj1S3A1HLllOS 3H1�0 3NIl.11L31SY3H1MON� � WL � �0�6 8� ��- o8'oC 46 ��_ �lt'S8L .�4 0oS6 � ���i 3.pp,90o£5S \ � _ ' I'��e � � ` tie � 5l"9► ,6 y- L8�£4 * - � � �Y'e� I ��..$�e� .e 4�9� � y, ,L4 .01, /�� J��'` vo�f,d�Y�6 ��t 6ot6 o`4`�b 00'OS �'�N4'6�- £9'OL / 6 tie y ^� �,`��6 6� (,�✓ !'..'� �'i ��e. ��ti6/�,��'�Cf' f�J �i�.° (�� C'J�� � ' � /i po�6x�� ����1 �, / �� � (��J�f� �^ �'�'6'' .c�� .�6 :') V �/ � � u �eo` `� �'o� �� �� — ` � � V � � ` N � �1 �� �/ ^` ti ♦ � f, � /'�� �� � ��i ��6 `^?ae � \�l \ / �C`46 1p�-�O <�b ��J r� .��4 a \ _ _ g�° '�Nh,�� S � $ �, � � � -- �Sr � � b I S�y��'6 oe �+ ��ON � � u O� `�,6 . ss�° zs ,,� p �`46 �` 040 � �`�6 �O �60�6 I � � �1� qops � �C,� 6 d qp. `^Pa �^ � e� .�'�t �I� ��`e�b ` � 8 /� SOZ � I.d' �I / �I�i� N ` 0��`6 � R �e �Z �ir.1�T �o��,������Z � � � ��� w � ' C I� � � � d.,Q,.� ,N�O �s / a � I r� a �` `46 � q�0 M`� �i/�l,* 1�3r,�J FCFFN � �a �' � �u � �Ois�oFf'N O,J �e _ cp` �"� ' � �1 � / � �� ��`9 �Os + � I /����i �� \ � �� � ! �i c�r��'N�NlNlyl3y=m$��� ���� 6� �,�/ ♦ n�\ \` 1 IY��6 Q� ��v'�� . / � ��S� �6 �p�4�6 � F��Lp��M NNfb13b s��g 4� � \ dbp�, �� .��60C a� � I O,� 6b6 �x� 00(��"5' `a .� �6 � SF � � � ti \ ` �6�05 ��� �� 8'.,°�',56 / 4�' �e �j ���`�y 1 1 \y 6��E�_6 Lq ��6+�� 9� ��J/ \ \ e . ^ � � 5py q�6�4S �t^ /^�/ ���- ��6�6 / / /\ \ p o�6 `�o`\ q 4� �6 9 �S � � / `�/ 094 ` \\ \ \ ,J s �y6 �° ��6 �,�,,Jf.� .�. `' / / / ���\ / � \ e`�r�s a 11�rt�.��. I 11 p .� 3?�� �'�.[1 � \ � \ Evelyn M. Turner From: Evelyn M. Turner Sent: Tuesday, August 10, 2010 12:35 PM To: 'greg@hatchgroup.com'; 'brian.monette@results.net' Subject: 350 Big Island Attachments: 350 big island what can I do with it.pdf; admin ci orono_mn_us_20100810 130907.pdf; admin ci orono_mn_us_20100810_131043.pdf; admin_ci_orono_mn_us_20100810_ 131017.pdf If the attached information doesn't answer your questions feel free to contact me. The 350 Big Island pdf contains setback, hardcover and rebuild information. The second is a portion of the survey of 340 Big Island that includes some information about 350. The third is information from an 1983 inventory of Big Island properties and the fourth is the sketch of the septic system. Evelyn Turner City Planner City of Orono 952-249-4623 952-249-4616 (fax) i