Loading...
HomeMy WebLinkAboutM19-000084 - HVACFrom: oronoinspector@ci.orono.mn.us Sent: 03/20/2019 - 08:30 AM To: lindal@heatcool2.com CC: Subject: Inspection Report Individual Inspection Report 699 MINNETONKA HGLD LA Permit M19-000084 Number: Site Address: 699 MINNETONKA HGLD LA, LONG LAKE, MN 55356 Property DOUGLAS P GIELOW Owner: Description: HVAC MECHANICAL 2 FURN, 2 AC, 1 BLR INFL HEAT GAR 3 BATHS, 6 GAS LINES, 6 BATH FANS, 2 AIR EX, PASSIVE MUA, 2 DRYER VENTS Inspection Date: 03/20/2019 Inspection Type: Mechanical -Air Test Inspection Results: Work Satisfactory: Proceed CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952)249-4616 Inspection Status: General Comment 1. LL in -floor heat. Pex tubing on 2 in. rigid styrofoam insul. over poly on rock bed. Air test holding at 50 psi since 3/15/19. Radon to vented out of two separate sump baskets. OK to continue. Jim H. Sincerely, Roger Peitso Building Official 952-249-4625 To schedule your inspections please call: (952) 249-4600 To schedule your inspection online Click Here CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY! From: oronoinspector@ci.orono.mn.us Sent: 04/01/2019 - 09:00 AM To: lindal@heatcool2.com CC: Subject: Inspection Report Individual Inspection Report 699 MINNETONKA HGLD LA Permit M19-000084 Number: Site Address: 699 MINNETONKA HGLD LA, LONG LAKE, MN 55356 Property DOUGLAS P GIELOW Owner: Description: HVAC MECHANICAL 2 FURN, 2 AC, 1 BLR INFL HEAT GAR 3 BATHS, 6 GAS LINES, 6 BATH FANS, 2 AIR EX, PASSIVE MUA, 2 DRYER VENTS Inspection Date: 04/01/2019 Inspection Type: Mechanical - Rough In Inspection Results: Work Satisfactory: Proceed Inspection Status: General Comment 1. Supplies, returns-ok Jason R. 2. Supplies, returns-ok Jason R. 3. Bath fans/ insul.-ok 4. Bath fans/ insul.-ok 5. Kit. Hood-ok 6. Kit. Hood-ok Sincerely, oyL Roger Peitso Building Official 952-249-4625 To schedule your inspections please call: (952) 249-4600 To schedule your inspection online Click Here CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952)249-4616 CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY! From: oronoinspector@ci.orono.mn.us Sent: 04/15/2019 - 02:37 PM To: lindal@heatcool2.com CC: Subject: Inspection Report Individual Inspection Report 699 MINNETONKA HGLD LA Permit M19-000084 Number: Site Address: 699 MINNETONKA HGLD LA, LONG LAKE, MN 55356 Property DOUGLAS P GIELOW Owner: Description: HVAC MECHANICAL 2 FURN, 2 AC, 1 BLR INFL HEAT GAR 3 BATHS, 6 GAS LINES, 6 BATH FANS, 2 AIR EX, PASSIVE MUA, 2 DRYER VENTS Inspection Date: 04/15/2019 Inspection Type: Mechanical -Air Test Inspection Results: Work Satisfactory: Proceed Inspection Status: General Comment CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952)249-4616 1. LL in -floor heat. Pex tubing on 2 in. rigid styrofoam insul. over poly on rock bed. Air test holding at 50 psi since 3/15/19. Radon to vented out of two separate sump baskets. OK to continue. Jim H. 2. UL bathrooms. Pex tubing. Air test is holding. OK to continue. Jim H. Sincerely, Roger Peitso Building Official 952-249-4625 To schedule your inspections please call: (952) 249-4600 To schedule your inspection online Click Here CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY! From: oronoinspector@ci.orono.mn.us Sent: 06/03/2019 - 01:39 PM To: lindal@heatcool2.com CC: Subject: Inspection Report Individual Inspection Report 699 MINNETONKA HGLD LA Permit M19-000084 Number: Site Address: 699 MINNETONKA HGLD LA, LONG LAKE, MN 55356 Property DOUGLAS P GIELOW Owner: Description: HVAC MECHANICAL 2 FURN, 2 AC, 1 BLR INFL HEAT GAR 3 BATHS, 6 GAS LINES, 6 BATH FANS, 2 AIR EX, PASSIVE MUA, 2 DRYER VENTS Inspection Date: 06/03/2019 Inspection Type: Mechanical - Rough In Inspection Results: Correct Work & Proceed CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952)249-4616 Inspection Status: General Comment 1. L. L. supplies and returns ok. Copper gas lines with air test holding. All ductwork to be areosealed. 1. Seal gas line penetration in fireplace chase. Correct and OK to continue. Jim H. Sincerely, Roger Peitso Building Official 952-249-4625 To schedule your inspections please call: (952) 249-4600 To schedule your inspection online Click Here CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY! From: oronoinspector@ci.orono.mn.us Sent: 07/08/2019 - 09:23 AM To: lindal@heatcool2.com CC: Subject: Inspection Report Individual Inspection Report 699 MINNETONKA HGLD LA Permit M19-000084 Number: Site Address: 699 MINNETONKA HGLD LA, LONG LAKE, MN 55356 Property DOUGLAS P GIELOW Owner: Description: HVAC MECHANICAL 2 FURN, 2 AC, 1 BLR INFL HEAT GAR 3 BATHS, 6 GAS LINES, 6 BATH FANS, 2 AIR EX, PASSIVE MUA, 2 DRYER VENTS Inspection Date: 07/08/2019 Inspection Type: Mechanical -Air Test Inspection Results: Correct Work & Proceed Inspection Status: General Comment CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952)249-4616 1. LL in -floor heat. Pex tubing on 2 in. rigid styrofoam insul. over poly on rock bed. Air test holding at 50 psi since 3/15/19. Radon to vented out of two separate sump baskets. OK to continue. Jim H. 2. UL bathrooms. Pex tubing. Air test is holding. OK to continue. Jim H. 3. Pex tubing on 2�?41 rigid styrofoam insulation for garage slab in floor heat. Air test at 93 psi. Set at 100 psi on 7/3/19. Check pressure prior to pouring. Correct and ok to continue. Jim H. Sincerely, Roger Peitso Building Official 952-249-4625 To schedule your inspections please call: (952) 249-4600 To schedule your inspection online Click Here CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY! From: oronoinspector@ci.orono.mn.us Sent: 11/07/2019 - 11:17 AM To: lindal@heatcool2.com CC: Subject: Inspection Report Individual Inspection Report 699 MINNETONKA HGLD LA Permit M19-000084 Number: Site Address: 699 MINNETONKA HGLD LA, LONG LAKE, MN 55356 Property DOUGLAS P GIELOW Owner: Description: HVAC MECHANICAL 2 FURN, 2 AC, 1 BLR INFL HEAT GAR 3 BATHS, 6 GAS LINES, 6 BATH FANS, 2 AIR EX, PASSIVE MUA, 2 DRYER VENTS Inspection Date: 11/07/2019 Inspection Type: Mechanical - Final Inspection Results: Correct Work. Call for Reinspection Inspection Status: General Comment CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952)249-4616 1. Range hood venting not installed. Jason R. 2. Provide level stable base for A/C 3. Future exterior gas lines protruding from wall far enough to present a safety concern. Contractor plans to cut back and add shut off. 4. Paint or replace black pipe fittings used at gas meter. 5. Gas manometer test is holding. There is no need to retest the system at reinspection.The remainder of the building is OK. Jason R Sincerely, Roger Peitso Building Official 952-249-4625 To schedule your inspections please call: (952) 249-4600 To schedule your inspection online Click Here CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY! From: oronoinspector@ci.orono.mn.us Sent: 11/20/2019 - 11:41 AM To: lindal@heatcool2.com CC: Subject: Inspection Report Individual Inspection Report 699 MINNETONKA HGLD LA Permit M19-000084 Number: Site Address: 699 MINNETONKA HGLD LA, LONG LAKE, MN 55356 Property DOUGLAS P GIELOW Owner: Description: HVAC MECHANICAL 2 FURN, 2 AC, 1 BLR INFL HEAT GAR 3 BATHS, 6 GAS LINES, 6 BATH FANS, 2 AIR EX, PASSIVE MUA, 2 DRYER VENTS Inspection Date: 11/20/2019 Inspection Type: Mechanical - Final Inspection Results: Permit Finaled CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952)249-4616 Inspection Status: General Comment 1. Corrections provided per previous inspection. Seal exterior mech penetrations. Contractor and permit finaled. Jim H. 2. Range hood venting not installed. Jason R. 3. Provide level stable base for A/C 4. Future exterior gas lines protruding from wall far enough to present a safety concern. Contractor plans to cut back and add shut off. 5. Paint or replace black pipe fittings used at gas meter. 6. Gas manometer test is holding. There is no need to retest the system at reinspection.The remainder of the building is OK. Jason R Sincerely, oyL Roger Peitso Building Official 952-249-4625 To schedule your inspections please call: (952) 249-4600 To schedule your inspection online Click Here CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY!