HomeMy WebLinkAbout1984-12-28 On Site Sewage Treatment Inspection Report,TE SEWAGE TREATMENT INSPECTION REPORT On the ,Vorth Shore of lake ,$finnetonka POST OFFICE BOX 66 1335 S. Brown Rd. Crystal Bay, MN 55323 473.7357 OWNER 7J&t•Sti�1� �%. ---.-ADDRESS__�� C� C'f:1�(Kcrrs rPT- 404n --- PHONE PERMII NO'S. - (7d7 t! • OATES _ �� / G`- City Ordinance No. 210 requires that each onsite sewage treatment system in Orono be inspected on a regular basis. The on-site sewage treatment system at the above address has been inspected and appears to fall into the category checked below: Meets or exceeds current city standards in all respects r.:,ting to design, construction, and location. Appears to be operating properly. 02 Does not meet current city standards in some respects relating to design, construction, or location. Appears to be operating properly. Does not meet current city standards in many respects relating to design, construction, or location. Appears 03 to be operating adequately. a Does not meet current city standards of design, construction or location, is being overused, or is failing !c properly treat and dispose of the current input and is therefore endangering a water supply, is a source of pollution to surface or groundwaters, is creating a safety hazard, or is otherwise creating a public nuisance. Please contact the inspector to discuss requirements for repairs to your system. Soil testing may be re- quired. In all cases a design and site plan must be submitted for review. Your contractor must obtain a permit before work is started. WORK REQUIRED: Septic tanks must be pumped within 48 hours. Drainfield must be repaired or eplaced within 90 days. ❑ Inspection riser (4" diani. p.pe) must be installed in each tank. Tank inspection indicates maintenance pumpout is needed as soon as possible. tanks be pumped outvery three year . -----) SITE CHARACTERISTICS: Limiting Site Factors ❑ Slope Soil High water table ❑ Lot size Lake, wetland, or stream ❑Drainage Potential for Systerr, . allure (depends on soil types, water table, and system condition) Low Medium (] High ❑ System is causing visible surface discharge. City ordinance requires that Site Capabilities for Future Expans,on Adequate ❑ Fair ❑ Poor ❑ Inadequate COMMENTS: r-, 5nmy-%S �,/Poc, /SC) -,ONKS E -,A r r�c4S %t :•�'*f 111�s�tiF�e_z1� Jroje— GC /•}ret'_ Snf rZ AJ & f'_ , 5 P77t . r CF.a OU F1 E'L G s A f 4,C ZA.)Af '7Z� TA, -&V 9• <T r L -,/L 1;L � C,4,LD , — - - Date of Inspection Septic Syst This report must be kept on the premises with system location and pumping records. WHITE COPY / Inspector's File GOLD COPY / Ilomeowner