Loading...
HomeMy WebLinkAbout1986-08-05 On Site Sewage Treatment Inspection ReportOn the N" Sbae of Lake Mianirrolrka ON-SITE SEWO.GE TREATMENT INSPECTION REPORT POST OFFICE BOX 66 1335 S. Brown Rd. Crystal Bay, MN 55323 473.7357 OWNER L C C4 ADDRESSq-1 5 'ij'gewA X"U /t — PERMIT NO.'S. DATES CONTRACTORS City Ordinance No. 210 requires that each on-site rwit" treatment system in Orono be inspected on a regular basis. The onsite sawege treatrnent fyftertn at the above tiara been Inspected and aplsemrt to IMI into the category checked below. (Thn iaan *.t%I sg fystmm ❑ new construction) 01 Meets or exceeds current City standards in all respects relating to design, construction, and location. Appear to be operating Property. [1 2 Don not meet all current City standards for new construction (1979 Cods) but in most respects appear to be designed. �u located, and constructed genaraily in accordance with previous codes. System appears to be functioning properly; no major upgrading of the system is required at this time. O3 Doer not meet current City standards ren many respects relating to design, construction, or location. Appears to be operating adequately at this time, but has a rotatively high potential lot future problems. No major upgrading of system is required at this time. 4 System may or may not meet current City standarde lot design, construction or location, but is hili g to Property treat and dispose of the current input, and is endangering a water supply, or is a source of pollution to surface or groundweten, or is crating a safety hara►d, or is otherwise creating a public nuisance. Please contact the City Inspector to drecuse system remit reptarcenrett procedures. If drainfold replacement is necessary, sod testing will usually be requited, and a design and site plan must be submitted for review. Your contractor must obtain a permit before work is started. SYSTEM CONDITION 10 Chocked items may require your action) Tank inspection indicates: �a Pumpout not ehae - at Mn time. ❑ Solids accumulation in tanks indicates they should be pump- ed out this yew to help prerent future problems. ❑ Solids aoevnutation in tanks n at a critical level. Tanks should to pumped out as Loon n possible. ❑ System is discharging to turfaca. Tanks must be pumped within 48 hour to elimlrrM sudece dtecharge. ❑ Inspection riser missing—twks could not be inspected. Inspection rinse 114" dim, pipe) must be installed in each tank at next pumpoul. If tanks haus not been pumped out within the last three yeah, they should bre pumped out now. SITE CHARACTERISTICS. Limiting Site Factors ❑ Slove ❑ Soil —fl High water table ❑ Lot ure ❑ Lake, wetland. or stream ❑ Drainage COMMENTS ❑ Inspection pipe is located directly over tank baffle. (Does not give accurate measurement of solids accwnulation.l If tanks hove not been pumped out within the last three year, they should be pumped out now. Dronfieid inspection indicates. —9 Orainfieid is dry, no surfacing evident. ❑ Some evlde+ce of surfacing, not critical yet. ❑ Orainfield it saturated and visibly desch ung untreated affluent to the suAaa. Thre condition may rputre replace- ment or additions to draintleld. Contact the City Inspector immedistNy. Repairs must be completed within 90 days. ❑ Drarnfleld extent and condition unknown. Potential for System Failure idepends on soil types, water table, and system condition) --Q Low ❑ Medium ❑ High ❑ System is causing insibie surface discharge. Acte u S T S ,9 S(r Date of Inspection Syster Inspector Site CapetsilHin low Future Expansion --e Adequate ❑ Fair ❑ Pop ❑ Inadequate Note In the went that this impaction report is used to satisfy the requirements for a mortgage at other transfer of property, be advised that this report does not guarantee or certify Mat an existing system will continue to function properly, but a merely an opinion of the adequacy of this system under current conditions based on the evadable information. This report must be kept on the Premises with system location and pumping records. WHITE COPY / Intpector's Fite GOLOCOPY / Homeowner