HomeMy WebLinkAboutM19-000023 - mechanicalFrom: oronoinspector@ci.orono.mn.us
Sent: 05/23/2019 - 09:12 AM
To: michellerl@gwestoffice.net
CC:
Subject: Inspection Report Individual
CITY OF ORONO
2750 KELLEY PARKWAY
ORONO, MN 55356
PH: (952) 249-4600
FAX: (952)249-4616
Inspection Report
1130 HUNTER DR
Permit Number: M19-000023
Site Address: 1130 HUNTER DR, WAYZATA, MN 55391
Property Owner: WOODDALE BUILDERS INC
Description: new home mechanical: 2 Turn, 2 A/C, 2 Air Ex, Hums, Unit heater, Gas to Main, Vent., Duct
Inspection Date: 05/23/2019
Inspection Type: Mechanical -Air Test
Inspection Results: Work Satisfactory: Proceed
Inspection Status: General Comment
1. Air test ok Jason R.
Sincerely,
Roger Peitso
Building Official
952-249-4625
To schedule your inspections please call: (952) 249-4600
To schedule your inspection online Click Here
CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY!
From: oronoinspector@ci.orono.mn.us
Sent: 06/25/2019 - 09:29 AM
To: michellerl@gwestoffice.net
CC:
Subject: Inspection Report Individual
Inspection Report
1130 HUNTER DR
Permit Number: M19-000023
Site Address: 1130 HUNTER DR, WAYZATA, MN 55391
Property Owner: WOODDALE BUILDERS INC
Description: new home mechanical: 2 Turn, 2 A/C, 2 Air Ex, Hums, Unit heater, Gas to Main, Vent., Duct
Inspection Date: 06/25/2019
Inspection Type: Mechanical - Rough In
Inspection Results: Correct Work & Proceed
Inspection Status: General Comment
CITY OF ORONO
2750 KELLEY PARKWAY
ORONO, MN 55356
PH: (952) 249-4600
FAX: (952)249-4616
1. Flashshield has main and garage heater only. Air test holding at 30 psi since 6/18/19. Other gas lines by plumber and have been tested. Supplies and returns
OK. Bath fans OK. Range hood hard piped to exterior. 1. Provide min 3 ft of insulation with vapor barrier in from exterior wall on range hood vent. Rest appears
ok, correct and ok to continue. Jim H.
Sincerely,
Roger Peitso
Building Official
952-249-4625
To schedule your inspections please call: (952) 249-4600
To schedule your inspection online Click Here
CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY!
From: oronoinspector@ci.orono.mn.us
Sent: 12/04/2019 - 03:42 PM
To: michelle@riccarhvac.com
CC:
Subject: Inspection Report Individual
Inspection Report
1130 HUNTER DR
Permit Number: M19-000023
Site Address: 1130 HUNTER DR, WAYZATA, MN 55391
Property Owner: WOODDALE BUILDERS INC
Description: new home mechanical: 2 Turn, 2 A/C, 2 Air Ex, Hums, Unit heater, Gas to Main, Vent., Duct
Inspection Date: 12/04/2019
Inspection Type: Mechanical - Final
Inspection Results: Permit Finaled
CITY OF ORONO
2750 KELLEY PARKWAY
ORONO, MN 55356
PH: (952) 249-4600
FAX: (952)249-4616
Inspection Status: General Comment
1. Gas line manometer is holding. 2 air exchangers are balanced. Kitchen hood ok. Bath fans ok. Boiler is closed system. 1. Label exterior hoods. 2. Low voltage
contractor must maintain code complying clearances from furnaces and boiler. Permit finaled.
Sincerely,
Roger Peitso
Building Official
952-249-4625
To schedule your inspections please call: (952) 249-4600
To schedule your inspection online Click Here
CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY!