Loading...
HomeMy WebLinkAboutM18-000284 - mechanicalFrom: oronoinspector@ci.orono.mn.us Sent: 03/06/2019 - 03:01 PM To: KLarson@LarsonPlumbing.com CC: Subject: Inspection Report Individual Inspection Report 780 LAKEVIEW PKWY Permit Number: M18-000284 Site Address: 780 LAKEVIEW PKWY, MOUND, MN 55364 Property Owner: CHRISTOPHER T EVENSON Description: New Construction Inspection Date: 03/06/2019 Inspection Type: Mechanical - Rough In Inspection Results: Correct Work & Proceed Inspection Status: General Comment CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952)249-4616 1. Supplies and returns OK. Bath fans ok. Kitchen hood hard piped to exterior and insulated. Ward flex gas lines with air test holding at 30 psi. 1. Provide structural straps on top plates of LL mid bearing wall in bedroom. 2. Provide permit card on site. Rest OK , correct and ok to continue. Jim H. Sincerely, ,--5 - Roger Peitso Building Official 952-249-4625 To schedule your inspections please call: (952) 249-4600 To schedule your inspection online Click Here CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY! From: oronoinspector@ci.orono.mn.us Sent: 07/08/2019 - 03:15 PM To: KLarson@LarsonPlumbing.com CC: Subject: Inspection Report Individual Inspection Report 780 LAKEVIEW PKWY Permit Number: M18-000284 Site Address: 780 LAKEVIEW PKWY, MOUND, MN 55364 Property Owner: CHRISTOPHER T EVENSON Description: New Construction Inspection Date: 07/08/2019 Inspection Type: Mechanical - Final Inspection Results: Correct Work. Call for Reinspection Inspection Status: General Comment CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952)249-4616 1. Gas line manometer is holding. Exterior hoods are labeled. Gas lines are labeled. 1. Garage heater not installed at this time. 2. Balance and label air handler. 3. Provide range hood. 4. No power to bath fans. 5. Bond gas tight gas line. 6. Finish installing registers. Correct and contractor will schedule reinspection with plumbing final inspection. Jim H. Sincerely, Roger Peitso Building Official 952-249-4625 To schedule your inspections please call: (952) 249-4600 To schedule your inspection online Click Here CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY! From: oronoinspector@ci.orono.mn.us Sent: 07/17/2019 - 03:28 PM To: KLarson@LarsonPlumbing.com CC: Subject: Inspection Report Individual Inspection Report 780 LAKEVIEW PKWY Permit Number: M18-000284 Site Address: 780 LAKEVIEW PKWY, MOUND, MN 55364 Property Owner: CHRISTOPHER T EVENSON Description: New Construction Inspection Date: 07/17/2019 Inspection Type: Mechanical - Final Inspection Results: Permit Finaled Inspection Status: General Comment CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952)249-4616 1. Gas line manometer tested at prior inspection. Gas line is bonded. Air handler is balanced. Bath fans ok. Range hood installed - no power at time of inspection. Garage heater ok. 1. Seal gas line penetration for garage heater. Rest of work complete, correct and permit finaled. Jim H. Sincerely, ,--5 - Roger Peitso Building Official 952-249-4625 To schedule your inspections please call: (952) 249-4600 To schedule your inspection online Click Here CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY!