Loading...
HomeMy WebLinkAboutM18-000219 - HVACFrom: oronoinspector@ci.orono.mn.us Sent: 10/24/2018 - 01:31 PM To: rick@djsonline.com CC: Subject: Inspection Report Individual Inspection Report 2697 CASCO POINT RD Permit Number: M18-000219 Site Address: 2697 CASCO POINT RD, WAYZATA, MN 55391 Property Owner: MARY C ENGER & MARK M ENGER Description: New Home HVAC Inspection Date: 10/24/2018 Inspection Type: Mechanical - Rough In Inspection Results: Correct Work & Proceed Inspection Status: General Comment CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952)249-4616 1. Supplies and returns are OK. All ductwork to be areosealed. Bath fans are OK. Range hood is OK. Copper gas lines with air test holding at 50 PSI. Trunklines in garage ceiling for bonus room above and in chase in garage will all be spray foam insulated. 1. Provide structural straps on top plate of the garage wall and isolated all copper lines from other metals. Correct and OK to continue. Jim H. Sincerely, Roger Peitso Building Official 952-249-4625 To schedule your inspections please call: (952) 249-4600 To schedule your inspection online Click Here CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY! From: oronoinspector@ci.orono.mn.us Sent: 05/17/2019 - 10:03 AM To: rick@djsonline.com CC: Subject: Inspection Report Individual CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952)249-4616 Inspection Report 2697 CASCO POINT RD Permit Number: M18-000219 Site Address: 2697 CASCO POINT RD, WAYZATA, MN 55391 Property Owner: MARY C ENGER & MARK M ENGER Description: New Home HVAC Inspection Date: 05/17/2019 Inspection Type: Mechanical - Final Inspection Results: Permit Finaled Inspection Status: Complete 1. Manometer holding, combustion air, gas line shut offs/ labeled, ERV, ext vents labeled Sincerely, Roger Peitso Building Official 952-249-4625 To schedule your inspections please call: (952) 249-4600 To schedule your inspection online Click Here CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY! Directions - In order to determine the makeup air, Table 501.3.1 must be filled out (see below). For most new installations, column A will be appropriate, however, if atmospherically vented appliances or solid fuel appliances are installed, use the appropriate column. For existing dwellings, see IMC 501.3.3. Please note, if the makeup air quantity is negative, no additional makeup air will be re- quired for ventilation, if the value is positive refer to Table 501.3.2 and size the opening. Transfer the cfm, size of opening and type (round, rectangular, flex or rigid) to the last line of section D. The make-up air supply must be installed per IMC 501.3.2.3. Table 501.3.1 PROCEDURE TO DETERMINE MAKEUP AIR QUANITY FOR EXHAUST EQUIPMENT IN DWELLINGS (Additional combustion air will be required for combustion appliances, see KAIR method for calculations) One or multiple power One or multiple fan- One atmospherically vent Multiple atmospherical - vent or direct vent ap- assisted appliances and gas or oil appliance or ly vented gas or oil pliances or no combus- power vent or direct vent one solid fuel appliance appliances or solid fuel tion appliances appliances appliances Column C Column D Column A Column B 0.15 0.09 0.06 0.03 a) pressure factor (cfm/sf) b) conditioned floor area,(sf) (including 5960 unfinished basements) Estimated House Infiltration (cfm): [la� x lb] 2. Exhaust Capacity a) continuous exhaust -only ventilation system (cfm); (not applicable to ba- PIJ lanced ventilation systems such as HRV) b) clothes dryer (cfm) 135 135 135 135 c) 80% of largest exhaust rating (cfm); Kitchen hood typically (not applicable if recirculating system or if powered makeup air is electrically interlocked and match to exhaust) d) 80% of next largest exhaust rating (cfm); bath fan typically Not (not applicable if recirculating system Applicable or if powered makeup air is electrically interlocked and matched to exhaust) Total Exhaust Capacity (cfm); [2a + 2b +2c + 2d] 3.Makeup Air Quantity (cfm) a) total exhaust capacity (from above) a) b) estimated house infiltration (from above) Makeup Air Quantity (cfm); (if value is negative, no makeup air is needed) 4. For makeup Air Opening Sizing, refer to Table 501.4.2 A. Use this column if there are other than fan -assisted or atmospherically vented gas or oil appliance or if there are no combustion appliances. (Power vent and direct vent appliances may be used.) B. Use this column if there is one fan -assisted appliance per venting system. (Appliances other than atmospherically vented appliances may also be in- cluded.) C. Use this column if there is one atmospherically vented (other than fan -assisted) gas or oil appliance per venting system or one solid fuel appliance. D. Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented gas or oil appliances and solid fuel appliances. Page 3 of 6