Subject: Inspection Report Individual
Inspection Report
2697 CASCO POINT RD
Permit Number:
M18-000219
Site Address:
2697 CASCO POINT RD, WAYZATA, MN 55391
Property Owner:
MARY C ENGER & MARK M ENGER
Description:
New Home HVAC
Inspection Date: 10/24/2018
Inspection Type: Mechanical - Rough In
Inspection Results: Correct Work & Proceed
Inspection Status: General Comment
CITY OF ORONO
2750 KELLEY PARKWAY
ORONO, MN 55356
PH: (952) 249-4600
FAX: (952)249-4616
1. Supplies and returns are OK. All ductwork to be areosealed. Bath fans are OK. Range hood is OK. Copper gas lines with air test holding at 50 PSI. Trunklines in
garage ceiling for bonus room above and in chase in garage will all be spray foam insulated. 1. Provide structural straps on top plate of the garage wall and
isolated all copper lines from other metals. Correct and OK to continue. Jim H.
Sincerely,
Roger Peitso
Building Official
952-249-4625
To schedule your inspections please call: (952) 249-4600
To schedule your inspection online Click Here
CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY!
From: oronoinspector@ci.orono.mn.us
Sent: 05/17/2019 - 10:03 AM
To: rick@djsonline.com
CC:
Subject: Inspection Report Individual
CITY OF ORONO
2750 KELLEY PARKWAY
ORONO, MN 55356
PH: (952) 249-4600
FAX: (952)249-4616
Inspection Report
2697 CASCO POINT RD
Permit Number:
M18-000219
Site Address:
2697 CASCO POINT RD, WAYZATA, MN 55391
Property Owner:
MARY C ENGER & MARK M ENGER
Description:
New Home HVAC
Inspection Date: 05/17/2019
Inspection Type: Mechanical - Final
Inspection Results: Permit Finaled
Inspection Status: Complete
1. Manometer holding, combustion air, gas line shut offs/ labeled, ERV, ext vents labeled
Sincerely,
Roger Peitso
Building Official
952-249-4625
To schedule your inspections please call: (952) 249-4600
To schedule your inspection online Click Here
CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY!
Directions - In order to determine the makeup air, Table 501.3.1 must be filled out (see below). For most new installations, column A
will be appropriate, however, if atmospherically vented appliances or solid fuel appliances are installed, use the appropriate column.
For existing dwellings, see IMC 501.3.3. Please note, if the makeup air quantity is negative, no additional makeup air will be re-
quired for ventilation, if the value is positive refer to Table 501.3.2 and size the opening. Transfer the cfm, size of opening and type
(round, rectangular, flex or rigid) to the last line of section D. The make-up air supply must be installed per IMC 501.3.2.3.
Table 501.3.1
PROCEDURE TO DETERMINE MAKEUP AIR QUANITY FOR EXHAUST EQUIPMENT IN DWELLINGS
(Additional combustion air will be required for combustion appliances, see KAIR method for calculations)
One or multiple power
One or multiple fan-
One atmospherically vent
Multiple atmospherical -
vent or direct vent ap-
assisted appliances and
gas or oil appliance or
ly vented gas or oil
pliances or no combus-
power vent or direct vent
one solid fuel appliance
appliances or solid fuel
tion appliances
appliances
appliances
Column C
Column D
Column A
Column B
0.15
0.09
0.06
0.03
a) pressure factor
(cfm/sf)
b) conditioned floor area,(sf) (including
5960
unfinished basements)
Estimated House Infiltration (cfm): [la�
x lb]
2. Exhaust Capacity
a) continuous exhaust -only ventilation
system (cfm); (not applicable to ba-
PIJ
lanced ventilation systems such as
HRV)
b) clothes dryer (cfm)
135
135
135
135
c) 80% of largest exhaust rating (cfm);
Kitchen hood typically
(not applicable if recirculating system
or if powered makeup air is electrically
interlocked and match to exhaust)
d) 80% of next largest exhaust rating
(cfm); bath fan typically
Not
(not applicable if recirculating system
Applicable
or if powered makeup air is electrically
interlocked and matched to exhaust)
Total Exhaust Capacity (cfm);
[2a + 2b +2c + 2d]
3.Makeup Air Quantity (cfm)
a) total exhaust capacity (from above)
a)
b) estimated house infiltration (from
above)
Makeup Air Quantity (cfm);
(if value is negative, no makeup air is
needed)
4. For makeup Air Opening Sizing, refer
to Table 501.4.2
A. Use this column if there are other than fan -assisted or atmospherically vented gas or oil appliance or if there are no combustion appliances. (Power vent
and direct vent appliances may be used.)
B. Use this column if there is one fan -assisted appliance per venting system. (Appliances other than atmospherically vented appliances may also be in-
cluded.)
C. Use this column if there is one atmospherically vented (other than fan -assisted) gas or oil appliance per venting system or one solid fuel appliance.
D. Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented gas or oil
appliances and solid fuel appliances.
Page 3 of 6