Loading...
HomeMy WebLinkAboutM18-000213 - mechanicalFrom: oronoinspector@ci.orono.mn.us Sent: 01/22/2019 - 11:44 AM To: PHIL@TITANSHVAC.COM CC: Subject: Inspection Report Individual CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952)249-4616 Inspection Report 539 KEENE AVE Permit Number: M18-000213 Site Address: 539 KEENE AVE, WAYZATA, MN 55391 Property Owner: LANE M BROOKS Description: 600 CFM EHXUST HOOD WITH MAKE UPAIR --- SEE WORK SHEET Inspection Date: 01/22/2019 Inspection Type: Mechanical - Final Inspection Results: Permit Finaled Inspection Status: General Comment 1. Kitchen hood with makeup air OK. Work complete for kitchen remodel. Permit finaled. Jim H. Sincerely, Roger Peitso Building Official 952-249-4625 To schedule your inspections please call: (952) 249-4600 To schedule your inspection online Click Here CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY! *000 40� 1102 A Use this column if there are other than fan -assisted or atmospherically vented gas or oil appliances or it there are no combustion appliances. B Use this column if there is one fan -assisted appliance per venting system, Other than atmospherically vented appliances may also be included. c Use this column if there is one atmospherically vented (other than fan -assisted) gas or oil appliance per venting system or one solid fuel appliance. D Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented gas or oil appliances and solid fuel appliances. ;0V 400/ A0 404 Table 501.3.1 Procedure to Determine Makeup Air Quantity for Exhaust Equipment in Dwellings Use the A ro "ate Column to Estimate House Infiltration One or multiple power vent One or multiple fan- One atmospherically Multiple atmospherically or direct vent appliances or assisted appliances and vented gas or oil vented gas or oil no combustion appliances^ power vent or direct vent appliance or one solid appliances or solid fuel a liancesB fuel a liancec J_ a liances° 1 a ressure factor cfmis 0,15 0.09 0,06 0,03 b) conditioned floor area (sfl (including unfinished basements) Estimated House Infiltration (cfm): �—� 1ax1b 2. Exhaust Capacity a) continuous exhaust- onlyventilation systems (cfm): (not applicable to balanced ventilation systems such as HRV) b) clothes dryer WON" 135 135 135 135 c) 80% of largest exhaust rating (cfm): (not applicable if � j�� recirculating system or �✓ if powered makeup air is electrically interlocked and matched to exhaust) d) 80% of next largest exhaust rating (cfm): (�� (not applicable if recirculating system or if powered makeup air is electrically interlocked and matched to exhaust) not applicable Total Exhaust Capacity (cfm): 2a+2b+2c+2d �� I Makeup Asir Requirement a) Total Exhaust Capacity ��'✓" from abovel, b) Estimated House Infiltration_ from above) Makeup Air Quantity (if value is negative, no makeup air is needed) 4, WONNOWN-066"" For Makeup Air Opening Sizing, refer to Table 501.3.2 A Use this column if there are other than fan -assisted or atmospherically vented gas or oil appliances or it there are no combustion appliances. B Use this column if there is one fan -assisted appliance per venting system, Other than atmospherically vented appliances may also be included. c Use this column if there is one atmospherically vented (other than fan -assisted) gas or oil appliance per venting system or one solid fuel appliance. D Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented gas or oil appliances and solid fuel appliances. ;0V 400/ A0 404