HomeMy WebLinkAboutM18-000213 - mechanicalFrom: oronoinspector@ci.orono.mn.us
Sent: 01/22/2019 - 11:44 AM
To: PHIL@TITANSHVAC.COM
CC:
Subject: Inspection Report Individual
CITY OF ORONO
2750 KELLEY PARKWAY
ORONO, MN 55356
PH: (952) 249-4600
FAX: (952)249-4616
Inspection Report
539 KEENE AVE
Permit Number: M18-000213
Site Address: 539 KEENE AVE, WAYZATA, MN 55391
Property Owner: LANE M BROOKS
Description: 600 CFM EHXUST HOOD WITH MAKE UPAIR --- SEE WORK SHEET
Inspection Date: 01/22/2019
Inspection Type: Mechanical - Final
Inspection Results: Permit Finaled
Inspection Status: General Comment
1. Kitchen hood with makeup air OK. Work complete for kitchen remodel. Permit finaled. Jim H.
Sincerely,
Roger Peitso
Building Official
952-249-4625
To schedule your inspections please call: (952) 249-4600
To schedule your inspection online Click Here
CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY!
*000
40�
1102
A Use this column if there are other than fan -assisted or atmospherically vented gas or oil appliances or it there are no combustion
appliances.
B Use this column if there is one fan -assisted appliance per venting system, Other than atmospherically vented appliances may also be
included.
c Use this column if there is one atmospherically vented (other than fan -assisted) gas or oil appliance per venting system or one solid fuel
appliance.
D Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically
vented gas or oil appliances and solid fuel appliances.
;0V
400/
A0
404
Table 501.3.1
Procedure
to Determine Makeup Air Quantity for Exhaust Equipment in Dwellings
Use the A ro "ate Column to Estimate House Infiltration
One or multiple power vent
One or multiple fan-
One atmospherically
Multiple atmospherically
or direct vent appliances or
assisted appliances and
vented gas or oil
vented gas or oil
no combustion appliances^
power vent or direct vent
appliance or one solid
appliances or solid fuel
a liancesB
fuel a liancec J_
a liances°
1 a
ressure factor cfmis
0,15
0.09
0,06
0,03
b)
conditioned floor area
(sfl (including
unfinished basements)
Estimated House
Infiltration (cfm):
�—�
1ax1b
2.
Exhaust Capacity
a)
continuous exhaust-
onlyventilation systems
(cfm): (not applicable
to balanced ventilation
systems such as HRV)
b)
clothes dryer WON"
135
135
135
135
c)
80% of largest exhaust
rating (cfm): (not
applicable if
� j��
recirculating system or
�✓
if powered makeup air
is electrically
interlocked and
matched to exhaust)
d)
80% of next largest
exhaust rating (cfm):
(��
(not applicable if
recirculating system or
if powered makeup air
is electrically
interlocked and
matched to exhaust)
not applicable
Total Exhaust Capacity
(cfm): 2a+2b+2c+2d
��
I
Makeup Asir
Requirement
a)
Total Exhaust Capacity
��'✓"
from abovel,
b)
Estimated House
Infiltration_ from above)
Makeup Air Quantity
(if value is negative, no
makeup air is needed)
4,
WONNOWN-066""
For Makeup Air
Opening Sizing, refer to
Table 501.3.2
A Use this column if there are other than fan -assisted or atmospherically vented gas or oil appliances or it there are no combustion
appliances.
B Use this column if there is one fan -assisted appliance per venting system, Other than atmospherically vented appliances may also be
included.
c Use this column if there is one atmospherically vented (other than fan -assisted) gas or oil appliance per venting system or one solid fuel
appliance.
D Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically
vented gas or oil appliances and solid fuel appliances.
;0V
400/
A0
404