Loading...
HomeMy WebLinkAbout03-15-2023 Septic Compliance inspection reportM MINNESOTA POLLUTION re Compliance inspection ort form CONTROL AGENCY p p p 520 Lafayette Road North Existing Subsurface Sewage Treatment System (SSTS) St. Paul, MN 55155-4194 Doc Type: Compliance and Enforcement Instructions: Inspector must submit completed form to Local Governmental Unit (LGU) and system owner within 15 days of final determination of compliance or noncompliance. Instructions for filling out this form are located on the Minnesota Pollution Control Agency (MPCA) website at https://www.i)ca.state.mn.us/sites/defaulttfiles/wq-wwists4-31a odf. Property information Local tracking number: Parcel IQ# or Sec/Twp/Range: 0511723120017 Reason for Inspection Propery Transfer Local regulatory authority info: _City of Orono Property address: _3415 High Lane Owner/representative: Garth Johnson (Realto Owner's phone: 612-670-0159 Brief system description: Approximately 2 -1000 -gallon septic tanks with a filter in the second tank, 1 -1000 -gallon lift station and 400 square feet of mound rock bed. System status System status on date (mm/dd/yyyy): 03/15/2023 ® Compliant —Certificate of compliance* (Valid for 3 years from report date unless evidence of an imminent threat to public health or safety requiring removal and abatement under section 145A.04, subdivision 8 is discovered or a shorter time frame exists in Local Ordinance.) *Note. Compliance indicates conformance with Minn. R. 7080.1500 as of system status date above and does not guarantee future performance. ❑ Noncompliant— Notice of noncompliance Systems failing to protect ground water must be upgraded, replaced, or use discontinued within the time required by local ordinance. An imminent threat to public health and safety (ITPHS) must be upgraded, replaced, or its use discontinued within ten months of receipt of this notice or within a shorter period if required by local ordinance or under section 145A.04 subdivision 8. Reason(s) for noncompliance (check all applicable) ❑ Impact on public health (Compliance component #1) - Imminent threat to public health and safety ❑ Tank integrity (Compliance component #2) — Failing to protect groundwater ❑ Other Compliance Conditions (Compliance component #3) — Imminent threat to public health and safety ❑ Other Compliance Conditions (Compliance component #3) — Failing to protect groundwater ❑ System not abandoned according to Minn. R. 7080.2500 (Compliance component 93) — Failing to protect groundwater ❑ Soil separation (Compliance component #5) — Failing to protect groundwater ❑ Operating permit/monitoring plan requirements (Compliance component #4) — Noncompliant - local ordinance applies Comments or recommendations There is 1.0 feet of sand under the rock bed. TBM: Bottom of the rock bed. ELV.-100.0 The system was designed for an at -grade. The installer opted for a three bedroom mound system with 1.0 feet of sand. The soils were verified by the city to have redox at 38-40 inches. There is a filter in the second tank. This will need cleanino oeriodicaliv. Certification 1 hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of future system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate maintenance, or future water usage. By typing my name below, 1 certify the above statements to be true and correct to the best of my knowledge, and that this information can be used for the purpose of processing this form. Business name: Rusty Olson Soil & percolation Testing Certification number: C1255 Inspector signature: Joseph J. Olson _ License number: L810 (This document has been electronically signed) Phone: 763-498-8779 Necessary or locally required supporting documentation (must be attached) ❑ Soil observation logs ® System/As-Built ❑ Locally required forms ® Tank Integrity Assessment ❑ Operating Permit ❑ Other information (list): https://www.pca.state.mn,us 651-295-6300 800-657-3864 Use your preferred relay service Available in alternative formats wq-wwists4-31b • 4/28/2021 Page 1 of 5 Property Address: 3415 High Lane Business Name: Rusty Olson Soil &percolation Testing Date: 03/15/2023 1. Impact on public health — Compliance component #1 of 5 Com liance criteria: System discharges sewage to the ❑ Yes* ®No ground surface System discharges sewage to drain ❑ Yes* ® No tile or surface waters. System causes sewage backup into []Yes* ® No dwellingor establishment. Any "yes" answer above indicates the system is an imminent threat to public health and safet . Describe verification methods and results: Visual. Nothing was found Attached supporting documentation: ❑ Other: ® Not applicable 2. Tank integrity — Compliance component #2 of 5 Compliance criteria: System consists of a seepage pit, ❑ Yes* ® No cesspool, drywell, leaching pit, or other it? Sewage tank(s) leak below their ❑ Yes" ® No designed operating depth? If yes, which sewage tanks leaks: Any "yes" answer above indicates the system is failing to protect groundwater. Describe verification methods and results: Elmer J. Peterson Company pumped the tanks. Attached supporting documentation: ❑ Empty tank(s) viewed by inspector Name of maintenance business: License number of maintenance business: Date of maintenance: ® Existing tank integrity assessment (Attach) Date of maintenance 3/8/2023 _ (mmlddlyyyy): (must be within three years) (See form instructions to ensure assessment complies with Minn. R. 7082.0700 subp. 4 B (1)) ❑ Tank is Noncompliant (pumping not necessary - explain below) ❑ Other: https://www.pca.state,mn.us 651-296-6300 800-657-3864 • Use your preferred relay service Available in alternative formats wg-wwists4-31b • 4/28/2021 Page 2 of 5 Property Address: 3415 High Lane Business Name: Rusty Olson Soil & percolation Testing Date: 03/15/2023 3. Other compliance conditions — Compliance component #3 of 5 3a. Maintenance hole covers appear to be structurally unsound (damaged, cracked, etc.), or unsecured? ❑ Yes' ® No ❑ Unknown 3b. Other issues (electrical hazards, etc.) to immediately and adversely impact public health or safety? ❑ Yes* ® No ❑ Unknown *Yes to 3a or 3b - System is an imminent threat to public health and safety. 3c. System is non -protective of ground water for other conditions as determined by inspector? ❑ Yes* ® No 3d. System not abandoned in accordance with Minn. R. 7080.2500? ❑ Yes* ® No *Yes to 3c or 3d - System is failing to protect groundwater. Describe verification methods and results: Visual. Nothing was found Attached supporting documentation: ® Not applicable ❑ 4. Operating permit and nitrogen BMP* — Compliance component #4 of 5 ❑ Not applicable Is the system operated under an Operating Permit? ❑ Yes ❑ No If "yes", A below is required Is the system required to employ a Nitrogen BMP specified in the system design? ❑ Yes ❑ No If "yes", B below is required ,BMP = Best Management Practice (s) specified in the system design If the answer to both questions is "no", this section does not need to be completed. Compliance criteria: a. Have the operating permit requirements been met? ❑ Yes ❑ No b. Is the required nitrogen BMP in place and properly functioning? ❑ Yes ❑ No Any "no" answer indicates noncompliance. Describe verification methods and results: Attached supporting documentation: ❑ Operating permit (Attach) ❑ https://www.pca.state.mn.us 651-296-6300 800-657-3864 Use your preferred relay service Available in alternative formats wq-wwists4-31b • 4/28/2021 Page 3 of 5 Property Address: 3415 High Lane Business Name: Rusly Olson Soil & percolation Testing S. Soil separation — Compliance component #5 of 5 Date of installation 9/16/2009 ❑ Unknown (mmlddlyyyy ShorelandlWelihead protection/Food ❑ Yes ❑ No beverage lodging? Compliance criteria (select one): 5a. For systems built prior to April 1, 1996, and ❑ Yes ❑ No* not located in Shoreland or Wellhead Protection Area or not serving a food, beverage or lodging establishment. Drainfield has at least a two -foot vertical separation distance from periodically saturated soil or bedrock. 5b. Non-performance systems built April 1, 1996, or later or for non- performance systems located in Shoreland or Wellhead Protection Areas or serving a food, beverage, or lodging establishment: Drainfield has a three-foot vertical separation distance from periodically saturated soil or bedrock.* 5c. "Experimental", "Other", or Performance" systems built under pre -2008 Rules; Type IV or V systems built under 2008 Rules 7080. 2350 or 7080.2400 (intermediate Inspector License required :5 2,500 gallons per day; Advanced Inspector License required > 2,500 gallons per day) Drainfield meets the designed vertical separation distance from periodically saturated soil or bedrock. Date: 03/15/2023 Attached supporting documentation: ❑ Soil observation logs completed for the report ❑ Two previous verifications of required vertical separation ❑ Not applicable (No soil treatment area) ® Soils verified by the city- ® Yes ❑ No* Indicate depths or elevations ❑ Yes [:]No* *Any "no" answer above indicates the system is failing to protect groundwater. Describe verification methods and results: A. Bottom of distribution media 100.0 B. Periodically saturated soil/bedrock Greater than 97.0 3.0 D. Required compliance separation* 1 2.55 *May be reduced up to 15 percent if allowed by Local Ordinance. Upgrade requirements: (Minn. Stat. § 115.55) An imminent threat to public health and safety (ITPHS) must be upgraded, replaced, or its use discontinued within ten months of receipt of this notice or within a shorter period if required by local ordinance. If the system is failing to protect ground water, the system must be upgraded, replaced, or its use discontinued within the time required by local ordinance. If an existing system is not failing as derined in law, and has at least two feet of design soil separation, then the system need not be upgraded, repaired, replaced, or its use discontinued, notwithstanding any local ordinance that is more strict. This provision does not apply to systems in shoreland areas, Wellhead Protection Areas, or those used in connection with food, https://www,pca.state.mn,us 651-296-6300 800-657-3864 Use your preferred relay service Available in alternative formats wq-wwists4-31b • 4/2$/2021 Page 4 of 5 beverage, and lodging establishments as defined in law. https://www.pca.state.Mn,US wq-wwists4-31b • 4/28/2021 651-296-6300 800-657.3864 Use your preferred relay service Available in alternative formats Page 5 of 5 Tank Report, Date: March S, 2023 Elmer I Peterson Co, 5921 Dague Ave. Delano, MN 55328 Phone 763-972-2420 Fax 765-972-72 17 MPGA License# 218 3415 High Lane Orono, MN 612-670-0154 Garth Johnson - Realtor Raffles: W1 Tank Capacity: # of Tanks: 3 "Type o#'Tanks: _ Gallons Pumped: OFF 3-1000 Gallon Tanks Per City Records Concrete 2500 Manholes to Grade: ES / NO Comments: On March 8, 2023, Elmer J. Peterson Co. pumped tanks and cleaned filter in 27Ld tank. No cracks or water leaking in tanks at tate time of pumping. NOTE: This is only a tank report. This is not a compliance inspection for point of sale nor does it replace a compliance inspection. MINNESOTA POLLUTION Sewage tank integrity assessment form CONTROL AGENCY g g y 520 Lafayette Road North Subsurface Sewage St, Paul, MN 55155-4194 Treatment Systems (SSTS) Program Doc Type: Compliance and Enforcement Purpose: This form may be used to certify the compliance status of the sewage tank components of the SSTS. This form is not a complete SSTS inspection report, only a tank integrity assessment, and may only certify sewage tank compliance status when entirely completed and signed by a qualified professional. SSTS compliance inspection report forms can be found at. https:flwww,pca.state.mn.us/water/inspections. Instructions: This form may he completed, and signed, by a Designated Certified Individual (DCI) of a licensed SSTS inspection, maintenance, installation, or service provider business who personally conducts the necessary procedures to assess the compliance status of each sewage tank in the system. Only a licensed maintenance business is authorized to pump the tank for assessment. A copy of this information should be submitted to the system owner and be maintained by the licensed SSTS business for a period of five (5) years from the assessment date. When this form is signed by a qualified certified professional, it becomes necessary supporting documentation to an Existing System Compliance Inspection Report: Compliance inspection form - Existing system (wg-wwists4.31 b). This form can be found on the MPCA website at htt s:!lwww oca. state.mn.us/wakefinspections. The information and certified statement on this form is required when existing septic tank compliance status is determined by an individual other than the SSTS Inspector that submits an inspection report. This form represents a third party assessment of SSTS component compliance and is allowable under Minn. R. 7082.0700, subp, 4(B)(1). This form is valid for a period of three years beyond the signature date on this form unless a new evaluation is requested by the owner or owner's agent or is required according to local regulations. Additional Administrative Rule references for this activity can be found at Minn. R. 7082.070C, subp. 4(B),(C), and (D) and; Minn. R. 7083.4730(C). Owner information Owner/Representative Garth Johnson (Realtor) Property address: 3415 High Lane Orono, MIN Local Regulatory Authority: _ Parcel ID: System status System status on date (mm/dd/yyyy): 318/2023 ® Certificate of sewage tank compliance ❑ Notice of sewage tank non-compliance Compliance criteria: The SSTS has a seepage pit, cesspool, drywell, leaching pit, or other pit - "Failure to Protect Groundwater." ❑ Yes" ® No The SSTS has a sewage tank that leaks below the designed operating depth - "Failure to Protect Groundwater." ❑ Yes' ® No The SSTS presents a threat to public safety by reason of structurally unsound (damaged, cracked, or weak) maintenance hole covers) or lids or any other unsafe condition - "Imminent Threat to ❑ Yes- ® No Public Health or Safety." Any "yes" answer above indicates sewage tank non-compliance. Company information Designated Certified Individual (DCI) information Company name: Elmer J. Peterson Co Print name. James L Brae2elmann__ Business license number: 219 - Certification number: I personally conducted the work described above as a Designated Certified Individual of a Minnesota -licensed SSTS inspection, maintenance, installation, or service provider Business. I personally conducted the necessary procedures to assess the compliance status of each sewage tank in this SSTS. By typingisigning my name below, i certify the above statements to be true and correct, to the best of my knowledge, and that this information can be used for the purpose of processing this form. Designated Certified Individual's signature: James L Brae elmann Date (mmiddiyyyy); 3/8/2023 (This document has been electronically signed.) www.pca.state.mn.us 651-296-63170 ■ 800-657-3864 Use your preferred relayservice Available in alternative formats wq-wwists4-91 • 3/10/21 Page I of 2 Logs of Soil Borings License #810 Location or Project: 3415 High Lane Borings made by: Rusty Olson's Soil and Perc testing 816/2009 Classification System: AASHO USDS- USDS-SCS X Unified ; Other_ Auger used (check two): Hand _X_, or Power , Flight, Bucket or Probe —X— 'Boring Number _1_ Surface elevation _66.6 0"-18" Dark brown loam 10yr3/2 18"-24" Brown loam IOyr4/4 24"-38" Brown loam 10yr5/4 -44" Rusty brown loam 10yr5/4 Boring Number _2_ Surface elevation 63.5 0"-18" Dark brown loam 10yr3/2 18"-32" Brown loam 10yr4/4 32"-44" Brown loam 10yr5/4 -50" Rusty brown loam 10yr5/4 Boring Number —3— Surface Elevation —66.6— W-1 8" 66.50"-18" Dark brown loam 10yr312 18"-24" Brown loam 10yr4/4 24"-38" Brown loam 10yr5/4 38"44" Rusty brown loam 10yr5/4 Mottled Soil at -3. 1feet H2O present at _X_ Mottled Soil at 3.7 feet H2O present at _X_ Mottled Soil at 3.1 feet H2O present at _X_ O Z v Q W Z J Z O W CA - cc j O cc O W cc Q W z W cc O d W QQ W O CJ CITY OF ORONO INSPECTION NOTICE PERMIT NO..... ADDRESS OWNER TELEPHONE NO. DESCRIPTION CALLED IN SCHEDULED COMPLETED ~� 1-4 �,- (, DATE TIME CONTR. ❑ FOOTING ❑ MECHANICAL RI ❑ FRAMING ❑ MECHANICAL FINAL ❑ INSULATION ❑ WOOD BURNER!FIREPLACE El WALL BD. ❑ WATER HOOK-UP ❑ FINAL ❑ SEWER HOOK-UP ❑ DEMO - SITE ❑ SEPTIC MAINT. ❑ DEMO - FINAL ❑ SEPTIC INSTALL. ❑ PLUMBING R# ❑ SEPTIC FINAL ❑ PLUMBING FINAL FOUNDATION/REMOVAL OWNER/CONTRACTOR TO MEET YOU: — YES _ NO COMMENTS: ❑ EXCAV/GRADING,'FILLING ❑ LAKESHORE/WETLANDS ❑ TREE REMOVAL ❑ STE INSPECTION ❑ PROGRESS ❑ COMPLAINT ❑ FOLLOW-UP ❑ HARD COVER REMOVAL ❑ FOUNDATION/REMOVAL For WORK SATISFACTORY: PROCEED it CORRECT WORK & PROCEED CORRECT WORK, CALL FOR REINSPECTION BEFORE COVERING U CORRECT UNSAFE CONDITION WITHIN HOURS. INSPECTOR WILL RETURN 0 STOP ORDER POSTED_ CALL INSPECTOR El INSPECTION REQUIRED. CALL TO ARRANGE ACCESS. E PROJECT COMPLETE ISSUE CERTIFICATE OF OCCUPANCY TEMPORARY PERMANENT PHOTO TAKEN CITATION ISSUED Call for the next inspection 24 hours in advance. (952) 249-4600 Owner/Contractor on site: Inspector. White Copytnspeor_ s File b Canary Copy/Site Notice V SEPTIC SYSTEM INVENTORY Site Address: 3415 High La Owner Name: Richard Marklund Owner Address: 3415 High La Long Lake MN 55356 - PID 05-117-23-12-0017 BuildingTvpe: residence Installer: Burns Excavating Date of Permit: 09/15/09 Svstem Tvpe: mound BR's Designed for 3 In Musa?: No Shoreland?: No SEPTIC TANKS: Material: concrete precast Capacity: 1000, 1000,1000 Tank Filter: DRAINFIELD: Treatment Area: 760 Soil Boring: yes OF Ht above Wt: 3 WELL DATA Setbacks - Well Tanks: 50+ Well DF: 75+ Report In File: Depth: 182 INSPECTION RECORDS Date Notes 11/1/2009 New mound System 6/1/2006 Non-compliant, replace by 12/31/2010 8/14/2002 non-compliant,replace by 12/31/2010 6/6/2000 non-compliant, repair by 12/31/2010 7/23/1997 non -compliant -repair by 12/31/2007 6/10/1993 no surfacing -pump tanks 5/21/1991 no surfacing 7/8/1987 no surfacing 7/14/1986 no surfacing 8/27/1982 no surfacing 8/27/1982 no surfacing PUMPOUT RECORDS_ Date GailonsOfLiquid 8/31/2017 2500 11/1/2009 0 4/28/2009 1000 7/13/2005 1000 7/1/2002 1000 8/4/1998 1000 10/19/1990 800 7/1/1987 1500 4/1/1983- 500 4/1/1983 ------- --- 500 5,�