HomeMy WebLinkAboutM18-000128 - HVACFrom: oronoinspector@ci.orono.mn.us
Sent: 10/10/2018 - 01:43 PM
To: sandy@sabreheating.com
CC:
Subject: Inspection Report Individual
Inspection Report
2835 GOLDENROD WAY
Permit Number: M18-000128
Site Address: 2835 GOLDENROD WAY, LONG LAKE, MN 55356
Property Owner: OP5 ORONO LLC
Description: New Hvac
Inspection Date: 10/10/2018
Inspection Type: Mechanical - Rough In
Inspection Results: Correct Work & Proceed
Inspection Status: General Comment
CITY OF ORONO
2750 KELLEY PARKWAY
ORONO, MN 55356
PH: (952) 249-4600
FAX: (952)249-4616
1. Supplies and returns are OK. Main level bath fans not vented through the roof at this time. Range hood vent is OK. Copper gas lines/maintain clearances from
dissimilar metals. No gas line air test at this time, provide gas line manometer at final mechanical inspection. Correct and OK to continue. Jim H.
Sincerely,
,--5 -
Roger Peitso
Building Official
952-249-4625
To schedule your inspections please call: (952) 249-4600
To schedule your inspection online Click Here
CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY!
From: oronoinspector@ci.orono.mn.us
Sent: 01/15/2019 - 09:20 AM
To: sandy@sabreheating.com
CC:
Subject: Inspection Report Individual
Inspection Report
2835 GOLDENROD WAY
Permit Number: M18-000128
Site Address: 2835 GOLDENROD WAY, LONG LAKE, MN 55356
Property Owner: OP5 ORONO LLC
Description: New Hvac
Inspection Date: 01/15/2019
Inspection Type: Mechanical - Final
Inspection Results: Permit Finaled
Inspection Status: General Comment
CITY OF ORONO
2750 KELLEY PARKWAY
ORONO, MN 55356
PH: (952) 249-4600
FAX: (952)249-4616
1. Gas line manometer is holding. ERV is self balancing. Aeroseal test results are on furnace. Gas lines are labeled. Bath fans are OK. Range hood OK. 1. Finish
installing floor register covers, rest of work completed, correct and permit final day. Jim H.
Sincerely,
,--5 -
Roger Peitso
Building Official
952-249-4625
To schedule your inspections please call: (952) 249-4600
To schedule your inspection online Click Here
CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY!