HomeMy WebLinkAboutM18-000111 - mechanicalFrom: oronoinspector@ci.orono.mn.us Sent: 08/08/2018 - 12:09 PM To: ejheating@yahoo.com CC: Subject: Inspection Report Individual Inspection Report 2340 Oliver Hill Rd Permit Number: M18-000111 Site Address: 2340 Oliver Hill Rd, Orono, MN 55323 Property Owner: Description: New Construction Inspection Date: 08/08/2018 Inspection Type: Mechanical - Rough In Inspection Results: Correct Work & Proceed Inspection Status: General Comment CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952)249-4616 1. Supplies and returns are OK for upper level and main level. Range hood vent is OK. Bath fans are OK. All joints are sealed. Contractor says all ductwork to be spray foam insulated. Copper gas lines with air test holding at 55 psi since August 6, 2018. Provide duct air test and finish lower level HVAC, correct and OK to continue upper level and main level. Jim H. Sincerely, Roger Peitso Building Official 952-249-4625 To schedule your inspections please call: (952) 249-4600 To schedule your inspection online Click Here CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY! Air Seal Tech Building Test Results for 2340 Ole® er Hill Rd Long Lake MN Duct Leakage Test Results Square footage 3959 sq. ft. Tested at -25Pa Total leakage 82 CFM Test results 2.10 CFM/100 Date 8-17-2018 Tested by Brian Larson BN #50;1223 Air Seal Tech 952-738-1462 info('a airseal.tech www.airseal.tech From: oronoinspector@ci.orono.mn.us Sent: 11/06/2018 - 04:08 PM To: ejheating@yahoo.com CC: Subject: Inspection Report Individual Inspection Report 2340 OLIVER HILL Permit Number: M18-000111 Site Address: 2340 OLIVER HILL, LONG LAKE, MN 55356 Property Owner: ROBERT C ERSTAD Description: New Construction Inspection Date: 11/06/2018 Inspection Type: Mechanical - Final Inspection Results: Correct Work & Proceed Inspection Status: General Comment CITY OF ORONO 2750 KELLEY PARKWAY ORONO, MN 55356 PH: (952) 249-4600 FAX: (952)249-4616 1. Gas line manometer is holding. Duct air test results viewed online, contractor will post in mechanical room. No power to bath fans or range hood at this time. HRV is balanced. 1. Paint black iron fittings on gas meter. 2. Finish installing them covers and bath fan covers. Rest of work for mechanical on this permit is OK, will check corrections at building final and will final mech. permit at that time. 3. Homeowner will provide permit and manufactures specs for garage heater/AC unit which is not on this permit. Jim H. Sincerely, Roger Peitso Building Official 952-249-4625 To schedule your inspections please call: (952) 249-4600 To schedule your inspection online Click Here CODE REQUIREMENTS ARE FOR YOUR PERSONAL HEALTH AND SAFETY!