HomeMy WebLinkAbout1986-07-31 On Site Waste Treatment Inspection ReportOil flit' Alutli Shon' u1. ON-SITE SEWAGE TREATMENT Lake tlinni-tonka INSPECTION REPORT POST OFFICE BOX 66 1335 S. Brown Rd. Crystal Bay, MN 55323 473-7357 OWNER---- r�//' ADDRESS � `' "-/� � 41cl– PERMIT NO.'S. 2 pLF— DATES s�sr 7/ -- CON TR ACTORS City Ordinance No. 210 requires that each ondrte sewaue treatment system in Orono he mspected on a regular basis. The on-site sewage treatment system at the Fen address has been inspected and appears to ;all into the category checked below IThis is existing system C1newconstruct onlEl1 Meetsor excceeds current City standards in all respects relating to design, construction, and location. Appears to tie. operating properly. �Z Does not meet all current City standards for new construction 11978 Code) but in most iestiects appcais to Ix, tlrsigr , totaled, and constructed generally in accordance with previous codes. System appears to be lunctioning p(operly; no orator upgrading of the system is required at this time. E13 Does not meet current City standards in many respects relating to design, construction, or location. Appears to be operating adequatety at this time, but has a relatively high potential lot future problems. No major upgrading of system is required at this time. 4 Syslem may or may not meal current City standards for dMign, construction or location, but is fading it ,,A"nly .:_rand dispose of the current input, and is endangering a water supply, or is a source of pollution to surface 1. of sr. is creating a safety harard, or is otherwise creating a public nuisance. Please contact the City Inspector to div :y . �Yatem tapairl replacement procedures. If drainheld replacement is necessary, soil testing will usually be required, and a desq, 4 yr • plan must be submitted for review. Your contractor must obtain a permit before work is started. SYSTEM CONDITION 1 10 Checked items may require your actionl TOXspeclion indicates umpout not needed at this time. olids accumulation in tanks indicates they should be pump• ed out thisyear to help prevent future problems. CJSolids accumulation in tanks is at a critical level. Tanks should be pumped out as so On as possible. Ll System is discharging to surface. Tanks must be pumped within 48 hours to eliminate surface discharge. ❑ Inspection risers missing—tanks could not be inspected. Inspection resets 14•• die, pipe) must be installed in each tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped out now. SITE CHARACTERISTICS Lnnitrnq Site Factors ❑ Slope ❑ So l ❑ High water table Lot sire Lake, wetland, or stream Orarnage ❑ Inspection pipe is located directly over tank baffle. (Does not give accurate measurement of solids accumulatron.l If tanks have not been pumped out within the last three years, they should be pumped out now. Orld instion indicates ainfegraipecnfield is dry, no wrfi ng evrdfent. C3 Some evidence o1 surfacing, not critical yet. ❑ Grainfield is saturated and v sibiy discharging untreated effluent to the surface. This condition may require replace- ment or additions to diainheld. Conir.t the City Inspector _ immediately. Repairs must be completed within 90 days. i l Dramfiefd extent and condition unknown. Potential for System Failure (depitnds on soil types, water table, and sysu•m , ondiltonl U Low ecjairn High ❑ System is causing visible surface dischimije. onto of Inspection Septic System Site Capabilities for Future Expansion 1-1 Adequate aro Poor f 1 Inadequate Lg v� % ilii a Note. In the event that this inspection reporl is used to satisfy the requirements lot a mortgage or other transfer of property, lir advised that this report does not guarantee or certify that an existing system will continue to function properly, but is mrrely an opinion of the a11t•quafy of the system under current conditions based on the available information. This report must be kept on the premises WAh system localton .Ind Punynnq recoups WHITE COPY t Inspector's File Got D COPY / Humdnrwnw