HomeMy WebLinkAbout1993-07-19 On Site Sewage Treatment Inspection ReportCITY OF ORONO
Municipal Offices
Post Office Box 66
Crystal Bay, MN 55323.0066
ON—SITE SEWAGE TREATMENT
INSPECTION REPORT
Owner:
Address:_� S// -
Permit Pa: M \l?- Patent
Contractors: /iY1KJ' 0a ,—
City ordinance nnnixer 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is Oil( an existing system ( I new construction)
CONFORMITY (1-3):
"CODE SYSTEM11-A system which sleets all the location, design, and censtruction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into grovel or surface waters.
"CONFORMING STSTEMii-A system which does not meet all the location, design, and construction standards of the
current City Codes but was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants Into ground or surface waters.
"NON -CONFORMING SYSTEM" -A prohibited system; o system located within a designated 100 -year floodplain; any
system which may or may not meet all the location, design, and construction standards of the current City
L
and which is failing for any reason; and
/between the distribution device and th i son r rist us.
(The limiting soil characteristic has or I I has not been identified at this time. If the limiting soil
characteristic has not been identi sed, this classification may be subject to revision.)
TANK CONDITION (5-10): 1
Tank inspection indicates:
5 Pumpout not needed at this time.
6 Solids acctmit ation in tr,..xs indicates they should be pupped out this year to help prevent future problems.
7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible.
System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge.
/9 1 Inspection risers missing -tanks could not be inspected. Inspection risers (4" die. pipe) must be installed in each
L / tank at next putpout. If tanks have not been pupped out within the last three years, they should
out now. —
10 InspecttW17-PIM is located directly over tank baffle (does not give accurate measurement of solids accumulation).
umped o
If tanks have rv,t been put within the last three years, they should be pumped out now.
GRAINFIELD CONDITION (11-14): IL
Dr,�f I field inspection indicates:
/ly Drainfield is dry, no surfacing evident.
`T2 Some evidence of surfacing, not critical yet.
13 Orainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
immediately. Repairs must be completed within 90 days.
14 Drainfield extent and condition unknown.
POTENTIAL FOR SYSTEM FAILURE (depends on soils.water table.etc,):
im
to of Inspection Seltic Syst
Note: In the event that this inspecti„n report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarantee or certify that an existing system will continue to function
properly, but is merely an opinion of the adequacy of the system under current conditions based on the available
information.
This report must be kept on the pre.nises with the system location and pumping records.
WHITE COPY Inspectors Fit* YELLOW COPY Homeowner