Loading...
HomeMy WebLinkAbout1984-04-17 Memo, Subdivision Soil Testing ReviewTO: Jeanne A. Mabusth, Zoning Administrator FROM: Michael P. Gaffron, Septic Systems Inspector DATE: April 17, 1984 SUBJECT: #804 - Painters Creek (Ski -Tonka) Bayside Road - Subdivision - Soil Testing Review The additional testing required on Lot 9 has been completed and a report has been submitted for City review. The lots which required additional work have been reevaluated and this information i3 now on file. I met with the site evaluator in early March and I am comfortable with his interpretations of the soil borings, which I had earlier questioned. I would like to make the following comments: Lot 1 (Sites 9A 6 9B) - Slope at tested sites averages 16-188 - Topographic location acceptable - Site drainage looks qood - HOUSE SITING CAPABILITY - I RECOMMEND WE ALLOW LESS THAN A 100' HOUSE SETBACK TO BAYSIDE ROAD, IN ORDER TO MINIMIZE POSSIBLE HOUSE ENCROACHMENT ON DRAINFIELD AREAS - Reported perc rates averagely MPI in top foot of soil, both sites - Depth to seasonal saturation zone 4-5' - Soil survey indicates Kilkenny Loam - BECAUSE OF THE STEEP SLOPES, I WOULD RECOMMEND THE TRENCHES BE NO WIDER THAN 2' - Based on depths to seasonal saturation indicated, the primary site should have a maximum trench depth of 1', and the alternate site trenches no deeper than 2' - As for the site evaluator':, notes, a curtain drain might have some benefit here, although its effect might be minimal due to the fine soil textures present Lot 2 ( Sites 10A 6 10B) - Slope at tested sites averages 128 - "opographic location - OK, but this is a slightly concive slope which will tend to hold water, s additional site drainage wcrk may be beneficial during construction - House siting capability - I recommend that specific house site "envelopes" be established to protect drainfield sites 4804 - Patiners Creek April 17, 1984 Page 4 ILot 10 - (Sites 17A, 17B, 10A (4/11/84) and 10B (4/11/84)) - This lot was retested since the original sites were located in a low drainage area - --� - The new sites are located on slopes of out 109 - Perc rates averaged 11 MPI primary s e, 13 MPI alternate site Seasonal saturation zones at 44-50" a rima;y_site would allow shallow trenches if a curtain drain is used to lower the seasonal water table. The alternate site should support a standard trench system. The propose house location near the southeast lot corner may not be feasible and a lift pump might ultimately be required for this site SUMMARY All ten proposed lots have sites which appear suitable for septic systems. On Lots 1-7, the drainfield site locations place some limitations on usable house sites. I recommend that house site "envelopes" be incorporated into the plat to help preserve the tested drainfield sites. Curtain drains may be of some benefit to certain sites and allow the use of shallow trench drainfields rather than mound systems. Based on the information submitted, I recommend approval of this PRD. The developers should be notified it is their responsibility to keep all traffic, qrading, fill, etc. away from the tested sites.