HomeMy WebLinkAbout1995-08-09 On Site Sewage Treatment Inspection ReportCITY OF 0RONO
Muni cipal Offices
lost Office box 66
Crystal Bay, !M $5323-0066
���kEeHv¢�G
Owner: TQ -s �sor� Address: 4-
/:ZL62
Permit 0'6: 4Y32 Dates: 6 ori' b,l Contractors:
ON-SITE SEWAGE TREATNiff!
INSPECTION REPORT
City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.
TMOn-site sewage treatment system at the above aduress has been inspected and appears to fell into the category
checked below.
(This is L,4 an existing system I I new construct,x )
"CME SYSTEM --A system which rets all the location, design, and constructiw.. standards of the current City
Codes, and which Is operating satisfactorily by treating and disposing of the entire current sewage Input
without discharging any pollutants into ground or surface waters.
"CONFORMING SYSTEM" -A system which does not meet all the location, design, and construction stardords of the
current City Codes but was Installed according to the code in effect at the time of installation, and which
is operating satisiactorfly by treating and disposir; of the entire current sews" input without discharging
Or pollutantsinto ground or surface waters.
"NOM-COMiORN ING SYSTEM --A prohibited system; a system located within a designated 100 -year floodplain; any
sstandards ystem which may or my riot meet all the location, design, and construction staards of the current City
Codes and which 1■ fainnp for any reason; and and system with less than 3 feet of unsaturated soil or sand
batween the dlstributfen dwica and the limiting soil characteristics.
(The limiting soil characteristic E4 has or I I has not been identified at this tiara. If the limiting soil
characteristic has not been identified, this classification may be subject to revislon.)
TANK CONDITION (5.10):
TWt Inspection indicates:
(3S� puspout not needed at this time.
Solids accusul at ion in tanks indicates they should be pt out this year to help prevent future orobleme.
7 Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible.
S System Is discharging to the surface. Tanks must be pumped out within iS hours to eliminate surface discharge
g Inspection risers missing -tanks could not be inspected. Inspection risers (i" die. pipe) oust be installed in'each
tank at next pumpout. If tarns have not been pumped out within the last three years, they should be pumped
out now.
10 Inspectionpipe Is located directly over tank baffle (does not ive accurate measurement of solids accumulation).
If tanks have not been =Out within the last three yews, they should be pumped out now.
DRAINFIELD COMDITION (11.11): LL
Dr�)ltf laid l,xcitlon indicates:
`IIKV Onfnf Feld fs dry, no surfacing evident.
Some evidence of surfacing, not critical yct.
13 Grainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
Im w is (y. Repel rs must be completed within t)0 days.
to Drainfleld extent andCondit ionunknown.
POTENTIAL FOR SYSTEM FAILURE (depends on soils.water table.etc.):
COMMENTS:
Date of Inspection Sepitic Sy tem Inspector
Note: In the event that this inspection report is used to satisfy the requirementsfor a acirtgsppe or other transfer of
property, be advised that this report does not guarantee or certify that an existing system will continue to function
properly, but is rarely an opinion of the adequacy of the system under current conditions based on the available
information.
This report must be kept on the prcAises with the system locstton and pumping records.
WMfTE COPY Anspeeiots File YELLOW COPY Non isaimi s,