HomeMy WebLinkAbout1992-07-28 On Site Sewage Treatment Inspection ReportCITY OF ORONO O� O
municipal Offices
Post Office pox 66
C".' ryscaI say, Me 55." -0066 .4 G / ON -RITE REXAOE TRE1111QIIT
IIEEPECTION REPORT
1
wnert_ ✓17PS 4r,<Dt-. Address: L/sw &V<Jee
Permit Uet '-#/-312 Dates: Contractors: P -4r -ay, %rt.
City ordinanicr number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis.
The on-site sewage treatment system at the above address has been Inspected and appears to fall into the category
checked below.
(This is A en existing system E I new construction)
-CODE SYSTEM" -A system which seats all the location, design, and construction standards of the current City
Codes, and which Is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into proud or surfer• waters.
nCOMFORMING SYSTEM -A system which does not met all the location, design, and construction standards of the
current City Codes but was installed according to .he code in effect at the time of installation, and which
Is operating satialactorlly by treating and disposing of the entire current sewage Input without discharging
any pollutants into proud or surface waters.
-4 M•COMFOMMIRG SYSTEM --A prohibited system; ■ system located within a designated 100 -year floodplain;
system which any or may not Beet all the location, design, and construction standards of the current City
Codes and which Is failing for any reason; and any system with less than 3 feet of unsaturated soft or said
between the distribution device and_ the limiting soil characteristics.
(TM limiting soil characteristic pr has or ( ) has not been identified at this time. If the limiting soil
characteristic has not been Identified, this classification my be subject to revision.)
TAW COMP 1719M (5.10): Ei
TywE inspection indicates:
[S"
Fits �(�t rot needed at this time.
6 Solids accumulation In tanks indicates they should be pumped out this year to help prevent future oroblems.
I Solids accumulation In tanks is at a critical level. Tanks should be pulped out as soon as possible.
O System is discharging to the surface. Tanks ant be pumped out within 6E hours to eliminate surface discharge.
9 Inspection risers missing -tanks could not be inspected. Inspection risers Wdie. pipe) must be installed in each
tank at next pupout. If tanks have not been pumped out within the last three years, they should be pumped
out now.
10 Inspection pipe is located di rsctly over tank baffle (does not give accurate mmssurement of solids accumulation).
If tenka have not been pongee scat within the last three years, they should be pumped out now. i
DRAINFIELD CONDITION (1116):
01field Inspection indicates-L:L-
�1T2y, bralnf laid is dry, ro surfacing evident.
Some evidence of surfacing, not critical yet.
13 Orafnfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector
f aimed) ate ly. Repairs must be completed within 90 days.
16 Drainfield extent and conditior unknown.
LIMITING SITE FACTORS (el Ope.fetbacka.etC,): 111 T
POTENTIAL FOR SYSTEM FAILURE (depends on solls.water toble.etc.):
COMMENTS:
_ t
Date of Inspection S ptic System Inspector
Mote: In the event that this inspection report Is used to satisfy the requirements far o mortgage or other transfer of
property, ie advised the this report does not guarantee or certify that an exist irg system rill continue to function
properly, but is merely an opinion of the adequacy of the system under current conditions based on the available
InlormaUon.
this report must be kept on the prc.nitrs with the system lccetirn mid pulping reco'ds.
WHITE COPY Inspecione Flie YELLOW COPY I/oneonMn