HomeMy WebLinkAbout1991-06-26 On Site Sewage Treatment Inspection ReportOrr the \'urfh Shore n1
l.akr Slimicrnrr4a
ON-SITE SEWAGE TREATMENT
INSPECTION REPORT POST OFFICE BOX 66
1335 S. Brown Rd.
Crystal Bay, MN 55323
473-7357
OWNER /[imp -s- 0/:27Y' !� _ ADDRESS �I5 91 —
PERMIT NO.'S. !SP 904 DADS 7 CONTRACTORS
City Ordrnana No. 210 raqutres tet each gr -Site WWW vestment tystem in Orono W inspected on a (egu- n port. The onsite sty"
veatrMnt system at the above addreo Ila peen Inspected and ppetes to fall into the category chocked below.
IThs is 0 an auttrng system ❑ new comsvunion)
O1 Man or exceed current City standards in all respect. relst- p to blas gr , conHruCtion, and local on. Appea s Io ba oparatn.g
proysrly.
2 Dao not meat all current City standards for new comtruciion 11978 Cods) but in most repaces appears to be designed,
located, and constructed generally in accot I w'th pieviout codes. System, appears to be funct—mil properly. no maim
p
upading of the system is required at this tome.
QJ n Does not mesal current City standards in maty respects relating to design, conttructron, or focalion. Appears to be paiat,nq
adauuataiv at inn tome, but has a rdsvY.ty high potential for future problems. No maim upgrading of system is recluned at
�./ this I—
f.� 4 Sr Hem may m may not meat current C,tv standards for design, comvucnon m location, but ., ruling to Property treat and
V9' drapose of the current input, and n endanganng a water supply. or n a souva of pollution to surface or groundwatws, m n
creating a safety hatted. m is othsevnte creating a Pudic nuisance. Pleats contact the City Inspector to dfncutt system repent
repacmvnt procedures. 11 drainfrold replscoment is necessary, fait telling mll usually be required, and a design and tate pan
mwt be wlsrrimld for rmrraw. Your contractor mint obtain a permit balms work rf started
SYSTEM CONOI TI ON I (Z CMcked -tams may requue your action)
Tani a ctfon -nd-cates.
►_,= not needed at this toms.
❑ Solids accumulation In tanks Indicates they should be pump.
ed out this year to help prevent future modems.
❑ Solids accumulation in tanks is at a urvW Inial. Tanks
should be pumped out o soon a pouibla.
❑ System is discharging to surface. Tanks must W pumped
ve-thim 48 heart to elimmete surface discharge.
❑ Inspection riven m-ping–tank, could hot be impacted.
InpKtoon lifers N" des. pipe) must W -stalled in each tank
of Met pumgp 1. If tanks hal rot been pumped out within
the last three vesre, they should br pumped wt now.
❑ Inspection pipeit located drrKtly over tank Wille. Il.oes not
go" a[curale maouremant of solids accumulat-on.l 11 tanks
hal not been pumped out within to left three Votes, they
shwld W pumped out now.
Drainlleld inspection indicates
❑--th Walmtleld is dry. no suit King awsm
d.
0 Some frindmhce at surfac-ng, not critical Vet.
IA Dlarnliold if saturated and •mbf, durstea.rha ,routaud .
M_ftuenl- to !hq_jv IM, Thu contht on mea invyir. re{Nacr_
mint m mWitbm to 6ainNtld. Contact the CHy Inwmuu
im lalnmlrt _Fa^P�i.diniodar,.
C, Oranfald eate-Tind tond ran imkiiw'r71- `__ •
SITE CHARACTERISTICS
-
Lwmvng Sire Facto,,
Potential Im SyHern Failure
Site Capefltbllae for
❑ Slop
Idepends on toe tvp.. water
Fur u EapanAon
1] s-
High
table Md, Mem, cond,toonl
C1trie
AdeqWte
y ..to,b
❑ Lot ore
low
❑ Mad—
Fur
0 Paw
❑ Lake, wetland, m Kean
O, High
❑ Inadequate
O Drurisge
645v11em n causing visible
tu,lete irrKharge.
COMMENTS
-----
Dateof Inpecvon-----
NoteIn he event that this ugpK l ran ,e m1 1f used to camso an
t qty the tlu it einem It Id mm tgnge Or tel her Itflef of or Opm ty. be advrled hot
this ,spoil dost not guaranlee m urufv that an arntrng ,vftem .,If Conomre to function property. bol if —.IV an opinion of the adequacy
of the ivtlmn under, current conditions based on the ays-labe rte/wmation
Thr, r"—t mull Ila keel un in, I—— with sysl-mh lci duon and Pumtvrp vicar 111
WIIITE COPY I Inspecicm's Fit. COt 0 COPY I Ilnmeownet