Loading...
HomeMy WebLinkAbout1977-08-16 Letter, Engineering Approval of Septic SystemWE COMBS-KNUTSON ASSOCIATES, INC CONSULTING FN61`11HNS a LANG SUPWO11S 6 SIT[ PLAhVf"S August 16, 1977 ,_� (1 1 Al Olson City of Orono n P.O. Box 66 _j 1, Crystal Bay, Minnesota 55323 Suhject: Septic System Application Vil:..`,;Z OF ORONO John Burger Residence Dear A1: We recommend approval of the subject septic system application. On August 9, 1977, we commented on the unsuttability of the soils because the percolation rates averaged less than 60 UPI. Since that time we have again reviewed the application and have noticed that the proposal includes a four feet trench with 6 -inches of Foamy sand beincr placed between the filter material and the original soil. This practice is recommended in WPC -40 for sites having percolation rates between 60-19() 11PI. Therefore, we recommend approval.• We further recommend that you inspect the site during construction to insure that the loamy sand is placed in accordance with the application. Very truly yours, I Mc(MMBS-RNUTSON ASSOCIATES, INC. XF o Frank. P.F. GF:ts 12WS OLSON MEMORIAL HIGHWAY, MINNEAPOLIS. MINNESOTA 55"1 TELEPW)NE 16171 550.3700 22 NOgTH MAIN STREET, HUTUdNSON, MINNESOTA 56,760 TELEPHONE #117) 679-6079 SOUTHWEST ENGINEERING DIVISION, MARSHALL, MINNESOTA 56258 TELEPHONE 15071 532 SM