My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1978 Subdivision Soil Test Data
Orono
>
Property Files
>
Street Address
>
B
>
Bayside Road - (AKA: Co. Rd. 84)
>
3211 Bayside Road - 05-117-23-41-0018
>
Septic
>
1978 Subdivision Soil Test Data
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:21:35 PM
Creation date
2/3/2023 1:47:59 PM
Metadata
Fields
Template:
x Address Old
House Number
3211
Street Name
Bayside
Street Type
Road
Address
3211 Bayside Rd
Document Type
Septic
PIN
0511723410018
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
8*) <br />ipll <br />TO: File <br />FROM: Mike Gaffron, Septic System Inspector <br />DATE: June 15, 1978 <br />RE: Additional Soils & Septic System Location Data for <br />Stielow Subdivision - 565 Leaf Street <br />A nunber of lots in this subdivision were retested to find more <br />suitable locations and soils for on-site sewage treatment systems. <br />Lot 1 - The problem on this lot is a very high water table. <br />Hr. Stielow*s engineering firm has proposed an innovative mound/ <br />fill type system utilizing draintile to lower the water table. <br />Slopes on the drainfield site are greater than allowable and <br />would be remedied by terracing. This system must have approval <br />of the city engineer prior to issuance of a building permit. <br />Lot 4 - Revised percolation rate 22 min./inch; 34 min./inch at <br />secondary site. Seasonal water table at 4 to 5 feet. A system <br />of very shallow trenches or a mound would be required for this <br />lot. <br />Lot 9 - Revised percolation rate 15 min./inch; 78 min./inch at <br />secondary site. Water table at 3 to 5 feet. Very shallow trenches <br />would be allowable on the primary site. The secondary site would <br />a mound. _ _ _ _ _ _ <br />Lot 11 - Revised percolation rate 15 min./inch; 44 min./inch at <br />secondary site. Seasonal water table at 2% ft. A mound system <br />would be required for both sites because of high water table. <br />"SUAiitaLy: With the exception of Lot 1, all lots in the proposed <br />subdivision appear to have suitable soils and locations for on-site <br />sewage treatment. Lot 1 will require some landscaping and de <br />watering for the proposed mound/fill system to work effectively. <br />This should be carefully reviewed by the city engineer.