09-29-1986 Septic System Design Memo
Orono
>
Property Files
>
Street Address
>
A
>
Abingdon Way
>
2355 Abingdon Way - 03-117-23-23-0006
>
Septic
>
09-29-1986 Septic System Design Memo
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:34:54 PM
Creation date
2/1/2023 1:49:18 PM
Metadata
Fields
Template:
x Address Old
House Number
2355
Street Name
Abingdon
Street Type
Way
Address
2355 Abingdon Way
Document Type
Septic
PIN
0311723230006
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
Page 1 of 1
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SYSTEM DESIGN <br />FOR LANDMARK CONSTRUCTION <br />OF LOT 1. BLOCK 1, ABINGDON GLEN <br />9-29-86 <br />1. Percolation Rate, Type of System. <br />22.0 minutes per inch, Shallow Trench System with interceptor drain. <br />2. Proposed Flow Rate. <br />5 possible bedrooms 0 150 6.P.D. = 750 6.P.D. <br />3. Soil Treatment Area Required. <br />1.67 percolation factor x 750 G.P.D. = 1250 Sq. Ft. <br />4. Size and Humber of Trenches. <br />5 trenches 3 feet wide and 83.3 feet long = 1250 Sq^,«EU* Ili?5U_yan|hes <br />would be spaced a minimum of 7.5 feet apart and bg^O.5 feet deep in^e <br />natural soil. . . .... <br />5. Drainfield Rock Needed. <br />46.3 cubic yds. of rock is needed to have 6 inches under and 2 inches over <br />a 4 inch distribution pipe. Black loam fill will be’needed over the top of <br />the trenches. <br />6. Septic Tanks. <br />Two septic tanks, of at least 1000 and 750 gallons are needed. In addition, <br />a third pumping tank and pump will be needed to reach the higher drainfield <br />ares. /OO O <5^ i-a I . <br />7. Additional Information. ' <br />All construction and materials must adhere to the provisions of the City of <br />Orono. Both the primary and alternate sites must be kept free from construe-- <br />tion traffic and grading since the alternate site may be needed.at some <br />r future time. An interceptor draintile should be used to divert runoff water <br />from the drainfield site. <br />If any other information is needed, please contact me. <br />Sincerely, <br />PERCOR, INC. <br />Hark S. Gronberg <br />PCA certified