My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1983-05-30 Site Evaluation Report
Orono
>
Property Files
>
Street Address
>
A
>
Abingdon Way
>
2340 Abingdon Way - 03-117-23-23-0015
>
Septic
>
1983-05-30 Site Evaluation Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:35:25 PM
Creation date
2/1/2023 11:55:40 AM
Metadata
Fields
Template:
x Address Old
House Number
2340
Street Name
Abingdon
Street Type
Way
Address
2340 Abingdon Way
Document Type
Septic
PIN
0311723230015
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
.a <br />SITE EVALUATION REPORT <br />FOR WILLOW PROPERTIES <br />( GARY PETERSON ) <br />OROSC, MINNESOTA <br />5-30-63 <br />On Kay 4-30, 1963 six percolation holes were tested on <br />each of 10 lots and 3 soil borings taken on each lot as well <br />in accordance with the provisions of Individual Sewage Sys <br />tem Treatment Standards (WPC-40) adopted in 1976 by the Minn <br />esota Pollution Control Agency. In addition, other soil bor <br />ings were taken in lower areas to determine the possibility <br />of obtaining more than 10 loti but water tables were found <br />to be very high and ^;£he soils were found to be very slowly <br />permeable. <br />According to the soils maps and the information we <br />found in'the field, the higher areas had very good soils for <br />dralnfields while the lower areas and swales had extremely <br />poor soils for dralnfields. Thus, we tended to stick to the <br />higher areas while still leaving room for ample building <br />sites. However, once houses are proposed to be constructed <br />it mighc be desired to shift some of the drainfield areas. <br />Then n w testing would be required and it would be advise- <br />able to keep i;s high u? o:i the knCbr as was previously tes <br />ted.-. <br />Each site testeu w.nuld be ucoeptable for either a stan <br />dard or shallow trench drainfield system and is noted on the <br />attached drawing. It also night be necessary to use inter <br />ceptor drains to divert runoff water but this would be men-’ <br />tioned in the system design for the Individual houses once <br />they are ready for construction. If any additional infoxTia- <br />tion is needed, please contact me. <br />Sincerely, <br />PERCOR, IKC. <br />'^Mark S. Gronberg, T.E <br />■ -j
The URL can be used to link to this page
Your browser does not support the video tag.