HomeMy WebLinkAbout05-30-1983 Soil Site Evaluation ReportSITE EVALUATION REPORT FOR WILLOW PROPERTIES ( GARY PETERSON ) ORONC, MINNESOTA 5-30-83 On May 4“30, 1963 six percolation holes were tested on each of 10 lots and 3 soil borings taken on each lot as well in accordance with the provisions of Individual Sewage Sys- ten Treatment Standards(V/PC-40) adopted in 1978 by the Minn­ esota Pollution Control Agency. In addition, other soil bor­ ings were taken in lower areas to determine the possibility of obtaining more than 10 lots but water tables were found to be very high and the soils were found to be very slov;ly permeable. According to the soils maps and the information we found in the field, the higher areas had very good soils for drainfields while the lower areas and swales had extremely poor soils for drainfields. Thus, we tended to stick to the higher areas while still leaving room for ample building sites. However, once houses are proposed to be constructed it .might; be desired to shift some of the drainfield areas. The.n r v; testing would be required and it would be advise- able to keep as high up on the knobs as was previously tes­ ted. SiCh site tested would be acceptable for either a stan­ dard or shallow trench drainfield system and is noted on the attached drawing. It also might be necessary to use inter­ ceptor drains to divert runoff water but this would be men-' tioned in the system design for the individual houses once they are ready for construction. If any additional informa­ tion is needed, please contact mo. Sincerely, PERCOR, INC. ^Mark S. Gronberg, tTe.