HomeMy WebLinkAboutP19-000210 - plumbingPERMIT PROJECT
FILE #: 19-001383
500 SANDHILL DR LONG LAKE MN 55356
PLUMBING NEW CONSTRUCTION
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Rough In
Assign To
Permit #:
P19-000210 plumbing new construction
Created On
10/08/2019 by Anne Hentges
Notes
Under-ground
DATES
Date
10/09/2019
From
3: 30 PM
To
4: 00 PM
Completion Date
10/09/2019
Status
Inspection Passed: Proceed
#STATUS COMMENTS
INSPECTION COMMENTS
0 UG DWV PVC sch 40 with 5 lb air test holding. Backwater valves provided. Radon vented out of length of
PVC draintile pipe. OK to continue. Jim H.
PERMIT PROJECT
FILE #: 19-001383
500 SANDHILL DR LONG LAKE MN 55356
PLUMBING NEW CONSTRUCTION
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Rough In
Assign To
Permit #:
P19-000210 plumbing new construction
Created On
11/14/2019 by Anne Hentges
Notes
DATES
Date
11/15/2019
From
3: 00 PM
To
3: 30 PM
Completion Date
11/15/2019
Status
Inspection Passed: Proceed
#STATUS COMMENTS
INSPECTION COMMENTS
100 DWV PVC Schedule #40
101 Water lines insulted
102 5# air test holding
Jason R.
PERMIT PROJECT
FILE #: 19-001383
500 SANDHILL DR LONG LAKE MN 55356
PLUMBING NEW CONSTRUCTION
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Plumbing - Final
Assign To
Permit #:
P19-000210 plumbing new construction
Created On
01/10/2020 by Nola Dickhausen
Notes
DATES
Date
01/14/2020
From
3: 30 PM
To
4: 00 PM
Completion Date
01/14/2020
Status
Permit Finaled
Erosion Control Checked, Found Compliant
Is Vegetation Established
#STATUS COMMENTS
INSPECTION COMMENTS
0 Plumbing manometer is holding. Fixtures set and sealed. WH TPR valve ok. Sump basket sealed. Work
complete, permit naled. Jim H.
PERMIT PROJECT
FILE #: 19-001383
500 SANDHILL DR LONG LAKE MN 55356
PLUMBING NEW CONSTRUCTION
INSPECTION INFORMATION
Department
Community Development
Inspection Type
Set & Seal
Assign To
Nola Dickhausen
Permit #:
P19-000210 plumbing new construction
Created On
02/12/2020 by Anne Hentges
Notes
DATES
Date
02/13/2020
From
10: 00 AM
To
10: 30 AM
Completion Date
02/13/2020
Status
Inspection Passed: Proceed
Erosion Control Checked, Found Compliant
#STATUS COMMENTS
INSPECTION COMMENTS
0 ert 1563613224
serial 54632266
Rdg 0000624.59 3/4"