Loading...
HomeMy WebLinkAboutP19-000193 - plumbingPERMIT PROJECT FILE #: 19-001221 1400 BRACKETTS POINT RD WAYZATA MN 55391 NEW HOME  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Rough In   Assign To Permit #: P19-000193 New Home  Created On 10/09/2019 by Anna Carlson Notes Partial Underground Inspection DATES Date 10/10/2019    From 9: 00  AM To 9: 30  AM Completion Date 10/10/2019 Status Inspection Passed: Proceed #STATUS COMMENTS   INSPECTION COMMENTS  0 Deep sewer for North end of house and garage. Contrasting cleaner used PVC Sch 40. Clean outs okay, provide 5psi on entire system. Okay to backll  PERMIT PROJECT FILE #: 19-001221 1400 BRACKETTS POINT RD WAYZATA MN 55391 NEW HOME  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Rough In   Assign To Permit #: P19-000193 New Home  Created On 10/16/2019 by Anne Hentges Notes Partial UG DATES Date 10/17/2019    From 11: 30  AM To 12: 00  PM Completion Date 10/17/2019 Status Inspection Passed: Proceed #STATUS COMMENTS   INSPECTION COMMENTS  0 Partial inspection of underground plumbing for south end of house. Visual inspection. SCH 40 PVC DWV provide ve psi air test for complete underground. Jason R.  PERMIT PROJECT FILE #: 19-001221 1400 BRACKETTS POINT RD WAYZATA MN 55391 NEW HOME  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Rough In   Assign To Permit #: P19-000193 New Home  Created On 02/12/2020 by Anne Hentges Notes DATES Date 02/17/2020    From 9: 30  AM To 10: 00  AM Completion Date 02/17/2020 Status Inspection Passed: Proceed #STATUS COMMENTS   INSPECTION COMMENTS  0 Center portion of UG DWV PVC schl 40 with 5lb air test holding. Backwater valves provided. All drain tile to one sump basket with radon venting out of it. OK to continue. Jim H.  PERMIT PROJECT FILE #: 19-001221 1400 BRACKETTS POINT RD WAYZATA MN 55391 NEW HOME  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Rough In   Assign To Permit #: P19-000193 New Home  Created On 12/01/2020 by Anne Hentges Notes UG DATES Date 12/02/2020    From 10: 30  AM To 11: 00  AM Completion Date 12/02/2020 Status Inspection Passed: Proceed #STATUS COMMENTS    INSPECTION COMMENTS  100 DWV PVC Schedule #40 102 5# air test holding  PERMIT PROJECT FILE #: 19-001221 1400 BRACKETTS POINT RD WAYZATA MN 55391 NEW HOME  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Rough In   Assign To Permit #: P19-000193 New Home  Created On 01/25/2021 by Alicia Johnson Notes DATES Date 01/28/2021    From 10: 30  AM To 11: 00  AM Completion Date 01/28/2021 Status Inspection Passed: Proceed #STATUS COMMENTS    INSPECTION COMMENTS  0 Inspection for area A2 schedule 40 PVC and cast DWV per waterlines insulated. 102 5# air test holding  PERMIT PROJECT FILE #: 19-001221 1400 BRACKETTS POINT RD WAYZATA MN 55391 NEW HOME  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Rough In   Assign To Permit #: P19-000193 New Home  Created On 03/31/2021 by MnSpect Admin Notes Partial Rough In/ 1/2 house DATES Date 04/01/2021    From 9: 00  AM To 10: 00  AM Completion Date 04/01/2021 Status Inspection Passed: Proceed #STATUS COMMENTS     INSPECTION COMMENTS  0 Re-inspection Required More Nailing plates (DE) 100 Complete DWV PVC Schedule #40/ UG & AG Cast DWV & Schedule 40 PVC DWV (test passed) (DE) 102 Complete 5# air test holding/Section B (DE)  PERMIT PROJECT FILE #: 19-001221 1400 BRACKETTS POINT RD WAYZATA MN 55391 NEW HOME  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Final   Assign To Nicole Egan Permit #: P19-000193 New Home  Created On 06/30/2022 by Nicole Egan Notes DATES Date 07/01/2022    From 9: 15  AM To 10: 00  AM Completion Date 07/01/2022 Status Not ready: Reinspect  Erosion Control Checked, Found Compliant Is Vegetation Established #STATUS COMMENTS    INSPECTION COMMENTS  1 Re-inspection Required Menometer on upper two levels holding. Compliant. 2 Re-inspection Required All xtures not in. Most xtures not sealed . Will see at nal inspection.  PERMIT PROJECT FILE #: 19-001221 1400 BRACKETTS POINT RD WAYZATA MN 55391 NEW HOME  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Final   Assign To Nicole Egan Permit #: P19-000193 New Home  Created On 07/07/2022 by Nicole Egan Notes DATES Date 07/07/2022    From 3: 00  PM To 4: 30  PM Completion Date 07/07/2022 Status Partial Pass  Erosion Control Checked, Found Compliant Is Vegetation Established #STATUS COMMENTS        INSPECTION COMMENTS  1 Re-inspection Required The showers in the Master bedroom and the girls room to the right were not done. 2 Re-inspection Required The ice maker and the dishwasher/drain at main oor bar must be hooked up. 3 Re-inspection Required Dap the toilet in outside pool bath. 4 Re-inspection Required Hot water will be required to ow through all xtures - Hot water not calibrated 5 Review Comment The main level hall powder room is not nished. This bath will be put on new permit for basement 6 Review Comment All cleanouts will be inspected on the basement permit  PERMIT PROJECT FILE #: 19-001221 1400 BRACKETTS POINT RD WAYZATA MN 55391 NEW HOME  INSPECTION INFORMATION Department Community Development Inspection Type Plumbing - Final   Assign To Nicole Egan Permit #: P19-000193 New Home  Created On 08/16/2022 by Nicole Egan Notes DATES Date 08/18/2022    From 2: 00  PM To 2: 30  PM Completion Date 08/18/2022 Status Permit Finaled  Erosion Control Checked, Found Compliant Is Vegetation Established #STATUS COMMENTS        INSPECTION COMMENTS  1 Complete The showers in the Master bedroom and the girls room to the right were not done. 2 Complete The ice maker and the dishwasher/drain at main oor bar must be hooked up and hammer arrester added. 3 Complete Dap the toilet in outside pool bath. 4 Complete Hot water will be required to ow through all xtures - Hot water not calibrated 5 Complete The main level hall powder room is not nished. This bath will be put on new permit for basement 6 Complete All cleanouts will be inspected on the basement permit - We will look at these on the basement plumbing permit All cleanouts will be looked at on the basement plumbing permit 